LINEAR AIR GRILLE LF - 202/LF 212 / LF / LF ACCESSORIES

Similar documents
Door Hinges Drill-in Hinges

Organisational Kitchen Fittings Kitchen Cabinet Accessories


Hardware Fitting Accessories Bolts

LINEAR GRILLES AND REGISTERS

GRILLE AND REGISTER OPTIONS AND ACCESSORIES

NOTES: Dimensions in parentheses are mm. For 1600 grille length and width dimensional information, see table on page K1-25.

THE PLACEMENT OF ALUMINIUM PROFILES IN THE FRAME VIEW FROM THE FRONT SIDE 2

Interior Equipment/Shop Fittings

Simple, practical and economical. Largest range on the market. SlowMotion Zeta optional

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

Hahn AT-G. The simple hinge for light aluminium doors. Quick secure Wide variety of uses

LINEAR DIFFUSERS AND BAR GRILLES

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

3. Barrier elements. Barrier posts. Stainles steel

COLIBRI Ceiling. Square ceiling diffuser with discs for supply air QUICK FACTS

Model 30/L/0. Model 30/S/0. Shortl Blades, 0 Deflection 3/4" Spacing. Model 35/S/0 Short Blades, 0 Deflection 1/2" Spacing

Factory Assistance: Phone: Fax: Page 1

Architectural Aluminum Frames

C13.11 HANDLES AND CONNECTION PIECES C13 SIDE HUNG WINDOWS

TABLE OF CONTENTS. Impregnated... 1 NORDIC FENCE Fynbo FSC Certified... 1

ATTRACTION drawer. Twin-walled seel drawer. Complete. 50 Kilos resistance. indamatic. Range of concealed runners up to. self closing and soft closing.

S.NO Description Quantity Rate Amount

COLIBRITM. Ceiling. Square ceiling diffuser with discs for supply air. Quick guide

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

Accessories and workbenches

Awning and Casement Window

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

METALWORKS TARTAN PANELS General Installation Instructions

Hahn KT-R. Butt hinge for plastic doors

Concentra/Conversa. 544/600 range. Digital-brochure-544/600-Concentra/Conversa-02-SR

Table and Furniture Base Fittings Plinth Adjusting Fittings

metalworks Vector Assembly and Installation Instructions

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E

salto safe 4028 A12 Turn-tilt windows

METALWORKS Linear (Interior & Exterior Applications)

K15.12 ROLLENBAND K15 DOORS

INSTALLATION & OPERATION MANUAL ML-37 / ML-38 / ML-39 MLR-37 / MLR-38 / MLR-39. Redefine your comfort zone.

metalworks Plank Assembly and Installation Instructions 2.1 Read this entire document before proceeding with installation.

INTERIOR LIGHTING FLOREN.

L11.12 B-SLIDE L11 SLIDING DOORS

6625 WEST WILSHIRE BLVD. OKLAHOMA CITY, OK (405) FAX (405)

FEET, WHEELS, FLOOR FASTENINGS, SUPPORTS

Lift-off hinge. Rising hinge. Standard hinge. Heavy duty hinge. Parliament hinge. Spring hinge. Double action spring hinge. Concealed mortise hinge

Hardware Fitting Accessories Accessories

Kitchen Fittings Hanging Cabinets and Accessories

Smooth Operators. CS TrackSystems range offers a track system for every surface sliding doorway situation.

Kentaur Turnstiles Kentaur Full-Height Gates

POP PLUS / SPIDER SET-UP INSTRUCTIONS

Cabonyx Installation Manual

EMAC 001 ACCESS PANEL

77 cm. 5243/3-GA (3 pcs.) 5243/3-BO (3 pcs.)

RACK 19 AND NETWORKING SOLUTIONS FEATURES

INSTALLATION GUIDE MICROWAVE OVEN UPMC3084ST. MFL _00

Silent Aluflex 80 Sliding door system: A wealth of options for peoples who want the best

datasheet TCS-40 TCS SERIES ENGINEERING INFORMATION FEATURES APPLICATIONS Dual 8 LF drivers Wide dispersion High power rating Down-fill enclosure

UNIVERSAL PANEL AND GATE

MANUAL INSTALLATION. Linear Bar Grille - Heavy Duty LBPH/LBMH. v000 Issue Date: 09/17/ Price Industries Limited. All rights reserved.

Oxford Stalls Installation Instructions

SCW Series Product Assembly Manual 2008 SCW CURTAIN WALL

Products for fixing to Steelwork and Decking

Joiner Kit For Models N388, C450, E402B, E411T, E415H, E440T, E442B, E521T and E522B

Ziptrak. Overview. Ziptrak system considerations. Ziptrak Vertical screening ideal for outdoor restaurants, patios, verandas, corporate signage.

TRUE TECHNICAL SERVICE MANUAL - ALL MODELS. DOORS/DRAWERS/LIDS

Handleless Uni t Specification

ALDoor DOUBLE DOOR INSTALLATION

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

INTRODUCTION. EqunioxRoof.com. Pro Tip

Ceiling Installation

K15.13 FACE FIXED DOOR HINGES K15 DOORS

Carousels - Overlapping Slat

METALWORKS Concealed. Installation Instructions

series SMLD Smoke Evacuation Damper

Adjustable Feet Castors Accessories for Floor Elements

Series 525 LouvreMASTER Adjustable Louvre Window

North East Toilet Cubicles Ltd.

Safe and secure Dero

Bike Locker Model DBL1 & DBL2

METALWORKS Linear (Interior & Exterior Applications)

INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds

INTERNAL LININGS INSTALLATION GUIDE

TerraLink. Twisted Wire Mesh Gabions & Mattresses Welded Wire Mesh Gabions. Data Sheet s Index. TerraLink Products

1.) Type: VL-F Single compartment rectangular smoke extraction ducts and fittings

Jabiru Installation instructions

Proudly Manufactured in Australia by CTCI Pty Ltd

Installation Instructions with 90 Degree Return Panel -- Model E-DP9. Model Semi-Frameless Door & Panel

Leveling Feet, Base Plates and Casters

CYCL E STAT IO N. High Capacity

P I T A G O R A. v1.1 TECHNICAL REPORT

Air-supply elements. Air-supply elements MGE Flanged plate (p. 5-3) M12-1/4" (p. 5-4) Longitudinal end connector (p.

SLIDING SYSTEMS. Product catalog 2017

Control Panel Trunking IBOCO Wiring Systems

NewTechWood Screening Installation Guide. v au

SPG+S27 PATENT GLAZING. SPG+S27 Series Product Assembly Manual 1999

ENCLOSURES ENCLOSURES

DU50BS Code no

STATE WHEN ORDERING HI =...

Fashion series Phone:Sunny

Office Installation Guidelines

E11.15 HANDLES AND LOCKCASES E11 BOTTOM HUNG OPEN IN WINDOWS

Transcription:

TYPE LF - 202/LF 212 / LF 202-2 / LF 212-2 LINEAR AIR GRILLE ACCESSORIES DESCRIPTION The linear air grilles of LF-202, LF-212 series are suitable for installation on walls, ducts and false ceilings. The grilles can be used for both supply and extraction air applications. Their main characteristics are: The LF-202 grilles have a 12 mm blade pitch, while the LF-212 grilles have a 16 mm blade pitch. Blades constructed from extruded aluminium with braced triangular end, inclined by 15 ο. The types LF-202-2 and LF-212-2 are constructed with inclined blades at opposite direction, so that the air stream is distributed in two way pattern, at any desired ratio. Air-tight seal around the rear side perimeter in contact, to prevent air leakage and blackening of the false ceiling. Available for the 32 mm width frame. The grilles can be ordered with no frame for enhanced embodiment on the mounting surface. NOMINAL SIZES The LF grilles are available in any combination of dimensions to meet the needs of the project. We highlight that: The order dimensions are the dimensions of the opening. The blades are placed parallel to the first dimension of the grille. Opposed blades volume damper, adjustable by an easily accessible key. (-D) Dust or grease filter. The dust filters are available in white VILEDON or net black FCU type. Grease filters are metallic. (See relevant brochure). (-F) The grilles can be accessible (-A), with or without filter and filter case. (See relevant brochure). Equalizing grid. (-Ε) Mesh 6 mm x 6 mm for the constraint of foreign objects, etc. (-M) The grilles are available with 32 mm or 19 mm or 8 mm width frame. All types are available without frame. (C type). The grilles are available with hinged access door for FCU controllers (Types T and TT) INSTALLATION FIXING Each grille frame has counter punched holes and is delivered with flat-head, self-drilling screws, powder coated in the same RAL colour as the grille. For concealed installation, the frame has no holes. For type C, a border can be placed on the grilles perimeter. AIR FLOW CONTROL The volume damper is easily regulated by a key or a regulating screw. In the LF-202, LF-212 grilles the air pattern can be adjusted from +15 0 to -15 0 by rotating the grille by 180 0.

MATERIALS Frame and blades: Extruded aluminium anodized in matt silver or powder coated in RAL colour. Support tubes: Aluminium tubes, Φ 8 mm, placed transverse every 200 to 300 mm. Frame seal: «Ω» type PVC. (Only available for 32 mm width frame). Volume damper: Aluminium. Screws: Galvanized steel (DIN 7504). SPECIFICATION TEXT Supply or extract linear air grille of rectangular shape, consisting of fixed horizontal blades with braced triangular end, inclined by 15 0, from anodized aluminium. With optional volume damper and/or equalizing grid.

FOR ORDER PURPOSE, THE FIRST GIVEN DIMENSION REFERS TO THE DIMENSION PARALLEL TO THE BLADES LF-202/212 VIEW (L x H) LF-202/212-C VIEW (L x H) LF-202/212 VIEW (H x L) LF-202/212-C VIEW (H x L)

LF-202/212-2 VIEW (L x H) LF-202/212-2-C VIEW (H x L) LF-202/212-2 VIEW (H x L) LF-202/212-2-C VIEW (H x L)

LF-202/212 SECTION LF-202/212-2 SECTION LF-202/212-D SECTION WITH DAMPER LF-202/212-2-D SECTION WITH DAMPER LF-202/212-E SECTION WITH GRID LF-202/212-2-Ε SECTION WITH GRID LF-202/212 ANGLE, TOP VIEW

LF-202/212 ANGLE, VIEW (FRONTAL INSTALLATION) LF-202/212 ANGLE, SIDE VIEW (FRONTAL INSTALLATION) LF-202/212-ΤΤ VIEW LF-202/212-ΤΤ VIEW

LF-202/212-C-ΤΤ VIEW LF-202/212-ΤΤ SECTION L : Η : L 1 : H 1 : L 2 : H 2 : Β : d : S : Nominal length horizontal opening Nominal height vertical opening Length L 1 = L 10mm for Β = 32mm or 19mm. For Β = 8mm, L 1 = L 5mm Height Η 1 = Η 10mm for Β = 32mm or 19mm. For Β = 8mm, H 1 = H 5mm Overall length L 2 = L 1 + 2B Overall height Η 2 = Η 1 + 2B Frame width. Typical 32 mm. Optional 19 mm or 8 mm. Distance between support tubes. d = 200 to 300 mm depending on the grilles dimensions. Blade pitch. Typical 12 mm. Optional 16 mm. NOTES 1. When ordering, refer first to the dimension parallel to the blades, i.e. for horizontal blades length is specified first and for vertical blades height is specified first. 2. Volume damper is available for all types. 3. The grille comes with counter punched holes and self-drilling screws in the same RAL colour. 4. The number of holes are two (one on the right and one on the left) for grilles up to 250 mm, and four (two on the top and two on the bottom) for grilles over 300 mm. 5. The 8 mm width frame has no holes.