Weather Resistant Wireless Receiver AY-L23 Installation & Operating Guide

Similar documents
AY-U9xxBT Long-Range UHF-RFID Reader with Bluetooth BLE-ID Installation and User Manual

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

Wireless 900 MHz Receiver

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

WLS-5500 Receiver (KSF & W26)

Wireless Rain and Wireless Rain/Freeze Sensor

P700WLS IoProx Receiver

PIM400-TD2. User guide for Panel Interface Module PIM400-TD2

Installation Instructions RF8010/RF8310 RF8010/RF8310: EXTERNAL ANTENNA

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

2006 MFJ ENTERPRISES, INC.

+GF+ SIGNET Temperature Transmitter Instructions

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

LMLR-710 (Plug-in type door chime receiver) LMLT-711 (push unit door chime transmitter)

STI REPEATER. BEFORE YOU START Refer to this drawing to become familiar with all the parts. Installation and Operation Manual.

MLR-1105 (DC battery type door chime receiver) LMLT-711 (push unit door chime transmitter)

STI REPEATER HOW THE PRODUCT WORKS BEFORE YOU START. Installation and Operation Manual. Model: STI-34109

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Wireless Data Gathering Panel MODEL TS0825

Installation Instructions RF5910

ETC Installation Guide

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

Mounting Instruction. Compact Mini EGC Amplifier and Application

STC Test Report. Date : Page 1 of 13 No. : HM161169

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

ImproX Multi-discipline Readers INSTALLATION MANUAL

Qpets Rechargeable Remote Training System User Manual

SF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

GE Interlogix Fiber Options S714D & S7714D. Instruction Manual FIBER-OPTIC NETWORK TRANSMISSION SYSTEM

IB6 Series Solid-State Isolation Relay

WSA 8 BOX RELE Installation Manual

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Delta6.4 contactless smartcard reader and keypad

OEM KEYFOB TRANSMITTER DATA GUIDE

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

Universal End of Period (EOP) Segment Installation Manual

ETC Installation Guide

S ENSORLINK INSTALLATION MANUAL

JR12 Jam Nut Mount Optical Encoder

LH0070 Series Precision BCD Buffered Reference LH0071 Series Precision Binary Buffered Reference

Mass and Volume Flow Transmitter

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

Wireless Temp/Setpoint & Override Room Transmitter

SER8300 Series Terminal Equipment Controller with Optional PIR sensor Installation Guide

Mounting Kit for HP N-class Servers AR8014A

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

CD42-STS Operating Manual Diver/ROV Pipeline Pig Location & Tracking System

WS-7136U Wireless 433 MHz Temperature Station. Instruction Manual

HP 8921A Cell Site Test Set. Product Note AMPS Base Station Testing

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

Wireless Room Thermostat Installation and Operation Y6630D1007

USER GUIDE WS Weather station with wireless outdoor sensor. 433MHz

C99-20LL System Cable P/N 40935G-06 INSTALLATION SHEET

DU3 Ultrasonic Vehicle Detector

WIRELESS Energy Monitor - Smart Meter

AMB-1200C Deactivator Controller and AMB-1200A Countertop Antenna

Commercial Micro-D Subminiature I/O Products

Operating Instructions

ELECTRONIC THERMOSTAT: T920

QR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW

SV613 USB Interface Wireless Module SV613

Literature Number: JAJA390

PSM 900 Personal Monitor System. Personal Monitoring. Redefined.

QRP to 30-35W HF Packer Amp minihfpa Edition. Beat the downturn in HF conditions! Make your SOTA/NPOTA/WWF activations a success every time!

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

Quick Start Guide. ELPRO 905U-L-T Wireless I/O Transmitter Unit. man_905u-l-t_quickstart_v1.9.doc

Quik Bridge Two- Channel Receiver Document Number: Rev. C September 1999

QR12 (1.22 ) Diameter Optical Encoder

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

BRU-100 Physical Installation

Sarasota CM200 Sarasota HME900 Density Converter Electronics

2.4GHZ WIRELESS SYSTEM FOR POLICE VIDEO RECORDING

WS-7212NU Wireless 433 MHz Weather Station. Instruction Manual

Model 1791 VHF Radio User's Manual


Flatbed Printing. Application Note Rev. A. November Prepared by the Application Department

USER MANUAL Digital Wireless Gateway U9120-W4 (P/N: 44002G-01)

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O PRODUCT INFORMATION B&B ELECTRONICS

Current Loop Interface Module M 2025D

200, 201 Series Radio Telemetry Transmitters

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

500mW WIRELESS PHOTOCELL HL3-5x User s Manual Version 11/2017

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND)

RF3405E. Installation Instructions Wireless (RF) Inertia Transmitter

Installation & Weatherproofing Guide for ENCOM Broadband Radios

V~ DIMMER WITH BUILT-IN RADIO RECEIVER AND DALI OUTPUT FOR CONTROL BALLASTS AND LAMPS. Push-button input for manual controls.

USER MANUAL Universal Gateway U9921-GUV (P/N: 40994G-01)

Model RFT9709 Transmitter Instruction Manual

IMMS-CI-HW. Communications Controller Interface. Installation Instructions IMMS. Controller. Interface. AC From Transformer 24 VAC REM 24 VAC SEN

Point Six Wireless Unique, High Value Wireless Solutions. 418 MHz Transmitter

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GLX-D Wireless Systems

X80 Activator. User's Manual. Version 1.1.

Installation and Operating Manual. (version 4.05) AAS Access Control Station. Your Partner in Access Control

Lewmar 3 & 5 Button Wireless Remote Control Issue 1

RF1212 Catalog

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Transcription:

Weather Resistant Wireless Receiver AY-L23 Installation & Operating Guide June 2006

Table of Contents Table of Contents 1. Introduction...3 2. Mounting Instruction...4 3. Wiring Instruction...5 4. Operation Instruction...7 5. Compatible Transmitters...8 6. Specifications...9 Appendix A. Technical Support...10 AY-L23C Installation Manual Page 2

1. Introduction Introduction The AY-L23 is a weather resistant wireless receiver, compatible with all of Rosslare s wireless remote control transmitters. When receiving an ID from a wireless transmitter, the AY-L23 will output the ID in 26-Bit Wiegand format to an attached 26-Bit Wiegand controller. See Page 8 for a list of compatible transmitters. Page 3 AY-L23C Installation Manual

Mounting Instruction 2. Mounting Instruction To mount the receiver, perform the following: 1) Determine an appropriate mounting position for the receiver. Do not mount the receiver near any source of wireless interference or on any metal surface. 2) Peel off the back of the self-stick mounting label template included with the unit and place at the desired mounting position. 3) Using the template as a guide, drill two holes (hole size is indicated on mounting template) for mounting the receiver to the surface. 4) Drill a 7/16 (10mm) hole for the cable. 5) Remove the front case from the receiver. 6) Attach the receiver to the controller. (See wiring instructions) 7) Screw the receivers rear case on to its mounting location see and return the front case onto the mounted rear case. The receiver is to be used with control panels whose power supply is UL Listed Class 2 or equivalent. AY-L23C Installation Manual Page 4

3. Wiring Instruction Wiring Instruction The receiver is supplied with an 18-inch pigtail, having a 6-wire cable. To connect the receiver to the Controller, perform the following steps: 1) Prepare the receiver cable by cutting the cable jacket back 11/4 inches and strip the wires ½ inch. 2) Prepare the Controller cable by cutting the cable jacket back 11/4 inches and strip the wires ½ inch. 3) Splice the receiver s pigtail wires to the corresponding Controller wires and cover each connection (see the table on Page 2). 4) If the tamper output is being utilized, connect the purple wire to the correct input on the Controller. 5) Trim and cover all conductors that are not used. The table below shows how you should wire the receiver to the Controller. Color Wiegand Output Red DC + Input Black Ground White Data 1 Green Data 0 Brown LED Control Purple Tamper Page 5 AY-L23C Installation Manual

Wiring Instruction Note: The individual wires coming out of the receiver are color coded according to the recommended Wiegand standard. When using a separate power supply for the receiver, this supply and the Controller s power supply must have a common ground. The cable shield wire on the receiver should be attached to an Earth ground (best) or signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the receiver cable from external interference. AY-L23C Installation Manual Page 6

4. Operation Instruction Operation Instruction The receiver should be tested after wiring it to a power supply and the Controller. Do this by performing the following steps: 1) Power up the receiver. 2) Transmit using a Rosslare wireless remote control to the receiver. The LED will momentarily flash green and a short beep will be emitted. This indicates that the transmission has been received properly by the receiver. 3) After the data is processed by the Controller, the Controller can then turn the LED green. Refer to the Controller description of the LED operation if the receiver LED is controlled by the Controller. Page 7 AY-L23C Installation Manual

Compatible Transmitters 5. Compatible Transmitters SA-03 Three-Button Remote Control SA-26 One Button Remote Control SA-27 Two-Button Remote Control SA-28 Four-Button Remote Control AY-L23C Installation Manual Page 8

Specifications 6. Specifications Power Supply Type Operating Voltage Range Maximum Input Current Tamper Output Maximum Cable Distance to Controller Output Modulation: frequencies Read Range: Operating Temp. Range: Operating Humidity: Dimensions (LxWxD): Linear type recommended 5-16 VDC Standby : 25 ma Receive : 55 ma Open collector, active low, max. sink current is 16 ma 150 meters (500 ft.) 26-Bit Wiegand C: 433 MHz E: 868 MHz 165ft (50m) -31oC to 63oC (-25oF to 145oF) 0 to 95% (non condensing) 5.7 x 1.7 x 0.8 inches 145 x 43 x 20 mm Page 9 AY-L23C Installation Manual

Technical Support Appendix A. Technical Support Asia Pacific, Middle East, Africa Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com United States and Canada 1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com Europe Global Technical Support & Training Center HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com South America Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228 E-mail: support.la@rosslaresecurity.com Web Site: www.rosslaresecurity.com AY-L23C Installation Manual Page 10

www.rosslaresecurity.com 0706-0960174+00