Regal Series Recessed Flatwalls

Similar documents
SECTION PANELBOARDS

B. Manufacturers: Square-D, G.E. or Westinghosue.

Skyline Series. Overbed LED Light. Multiple Directional Light Configurations. 1 Amico Lights Corporation

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

PCS. Patient Security Service Console. Installation Instructions.

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Installation Instructions

SECTION LIGHTING PART 1- GENERAL

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION EQUIPMENT WIRING

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

SECTION CABLE TRAYS

St. Monica Food Pantry

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Infinity. Surface Mounted Headwall. Installation Instructions. The.

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

The V2100 Series Steel Raceway provides wiring

B. Division-16 Basic Materials and Methods section apply to work specified in this section.

WIREMOLD AL7450 Series Isoduct Aluminum Raceway

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Michigan State University Construction Standards WIRING DEVICES PAGE

SECTION DISTRIBUTION SWITCHBOARDS

Subject: P0052 Bed Locator Installation Instructions

FSK1VDRA 1G Al DPLX RCPT CVR

UFGS-16553N (Septermber 1999) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION DISTRIBUTION SWITCHBOARDS

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

A. Deviation from this standard must be approved by the Project Architect.

Piping & Equipment Identification

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

SECTION SWINGING AUTOMATIC ENTRANCES

Power Matrix Price List

Ground Clamps Cable Tray

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Ductwork Controls and Instrumentation Outlets (HVAC) HVAC Control System.

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

SECTION TRANSFORMERS

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Architectural Door Accessories. Markar Continuous Hinges

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

SPECIAL SPECIFICATION LIGHTNING PROTECTION SYSTEM

SECTION INTERCOMMUNICATIONS SYSTEMS. A. Section Includes: Manually switched intercommunications systems with the following components:

Die Cast Screw-In Connector

Moveable Workstations. Enterprise KEWAUNEE. encouraging new discovery...worldwide

PSOL. Remove mounting screws. Remove ears. Add 6" leads PSOL = #12 AWG solid PSTR = #12 AWG stranded

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Wiring of the Main Distribution Panelboard

1. Field measurements must be taken to verify existing conditions prior to installation.

THHN12STGN500 THHN 12 STR Green 500

THHN2BK2500 THHN 2 STR Black 2500

January 2011 POWER & DATA OPTIONS PLANNING GUIDE

Guide Specification Section Interior Suspended Sliding Glass Doors

Installation Instructions. Monitor Roll Stand

Compass Patient Headwall. Installation Guidelines. Prior to installation, please carefully read and familiarize yourself with all of the Guidelines

Chapter 25. Lighting Plans

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

CITY OF NEW ROCHELLE RENOVATIONS TO FIRE STATION NO WEBSTER AVENUE, NEW ROCHELLE, NEW YORK

Wiring Information. Blinds & Shades

SECTION ELECTRICAL IDENTIFICATION

Lightplane 3.5 Recessed

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site

Page Electric Utility Service Specifications

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

UNIFIED FACILITIES GUIDE SPECIFICATIONS

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray.

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

Spec Section: , Complete Elec, Comm, and Fire Alarm , Complete Elec, Comm, and Fire Alarm Data Sheets RAN/GCAN

CONTINUING EDUC ATION

SECTION CHAIN LINK FENCING AND GATES

SECTION MEDICAL AND SURGICAL LIGHTING FIXTURES

DOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

Rectangular Industrial Connectors: Technical Data Overview EPIC HBE SERIES

Hilti, Inc. November Dallas Parkway, Suite 1000 Plano, Texas Toll Free Website Guide Specification

Examination, Reading and Ambient lighting

Workstation Outlets GigaFlex PS6+ Modules Category 6

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT

CP /240-MC4 User Manual

Article 250 Grounding & Bonding

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

Transcription:

Regal Series Recessed Flatwalls General Specifications The Amico Regal Series Recessed Flatwall shall be manufactured by Amico Corporation, in accordance with job specific shop drawings and documents. The complete Flatwall assembly shall be culus listed. The following is a general specification, and components listed may not be present or required in final product. The Regal Series Flatwall System is listed by Underwriters Laboratories Inc.(UL) in Canada and the United States of America. This product also complies with the seismic requirements of, and is approved by the State of California s Office of Statewide Health Planning and Development (OSPHD). Amico Corporation manufactures all products in accordance with the National Fire Protection Association (NFPA), NFPA-99c (current edition) and National Electric Code (NEC). The installation contractor is responsible for compliance with all local, state, and federal codes applicable to the installation of medical gas and electrical systems. Submittals and Verifications Job specific shop drawings shall be produced for each project. These shop drawings will clearly indicate the area of Medical Gas termination, and electrical connection points outside the Flatwall System. As Built drawings will be produced, and emailed at the time of shipment. Amico Corporation will manufacture equipment as per signed approval drawings and verifications documents, which are provided in the job specific submittal package. C US LISTED Figure 1. Regal Series 14" (356 mm) Recessed Flatwall

Regal Series Recessed Flatwalls Materials and Construction Enclosure shall be constructed of one piece galvanized steel back box to provide a modular unit with accessory rails for equipment management. Standard widths of the Regal Series Recessed Flatwall are 14" (356 mm) and 19" (483 mm). Standard heights are 55" (1397 mm) and 72" (1829 mm) heights. The Regal Recessed Flatwalls can be single sided or back to back and come equipped with a stud assembly. Each headwall system has shall contain electrical conduit to enclose electrical wiring for each type of power (critical, normal and low voltage/communication). All med gas piping shall be hard-piped and brazed to a single point of connection. Med gas pipes will terminate above the ceiling line. Accessory Rails The Recessed Flatwall System has two (2) accessory channels. The accessory channels are clear etched anodized or powder coated aluminum. Fascia Single piece of laminated or powder coated aluminum. Medical Gas Outlets Amico Corporation manufactures several compatible connection types for Medical Gas and Vacuum Outlets. The outlet connection type shall be as called for on the signed approval documents. Medical Gas Manifold Medical gas distribution shall be supplied by pipe drops to the single point connection above the unit as indicated on the drawing. All Medical Gas Outlets and piping shall be brazed and tested in accordance with NFPA 99c. All Medical Gas piping shall be Type L copper pipe. Each outlet, piping and manifold shall pass a 24 hour standing pressure test. Electrical Wiring Wire for standard and critical branch power circuits shall be #10 or #12 (as specified) type THHN stranded copper wire, 600 volt, with heat resistant thermoplastic insulation for hot (black) and neutral (white). Grounds shall be #10 type R THHN stranded copper wire (green). All ground conductors shall be installed in conduit. Grounding and Bonding All ground conductors shall be installed in conduit. Each power receptacle shall have a ground conductor connected to a grounding screw. A grounding bus will be installed in each device barrier box, and shall be installed as to insure grounding for the complete power system. Electrical Receptacles Shall be HUBBELL Hospital Grade 15 or 20 amp, 120 or 277 volt, UL listed and marked Hospital Grade. Quantity and type as shown on drawings. Amico shall furnish and install receptacles with wiring required, as shown on submittal shop drawings. All receptacles shall be HUBBELL hospital grade receptacles. Electrical contractor shall insure compatibility of plug on accessory equipment to be used with these devices: Duplex Receptacles shall be NEMA style 5-15R or 5-20R, color Ivory for use on normal power circuits, and color Red for Simplex Receptacles shall be NEMA style 5-15R or 5-20R, color Ivory for use on normal power circuits, and color Red for Safety Receptacles (if required) shall be duplex type, be NEMA style 5-15R or 5-20R, color Ivory for use on normal power circuits, and color Red for use on critical branch power circuits. Receptacles shall limit proper access to energized contracts and shall accept both 2 wire and 3 wire plugs. Locking Receptacles (if required) shall be simplex type, 20 amp, 120 or 277 volt, color black, and be HUBBELL lock 23000 HG style. Low Voltage Data Provisions Shall be connected to device junction box via conduit. Amico Corporation shall include pull cord extending from service provision to electrical termination point. Telephone jack, Blank faceplates, Data port or other Low Voltage device shall be furnished, installed and wired by Low Voltage contractor. Switching Shall be HUBBELL Industrial Grade 120 or 277 volt, 15 or 20 amps. Switch type options include SPST, 3-Way or Momentary, as shown on submittal shop drawings. Low Voltage Switching will be 0-12 volts, 15 amps unless otherwise noted. Amico Corporation shall furnish, pre-install and wire all switches.

Regal Series Recessed Flatwalls Lighting (Optional) Direct, Indirect and night light lighting can be provided by the Amico 3' or 4' overbed or ceiling lighting system. These fixtures provide lighting on and above the patient bed. Each fixture shall accommodate three (3) fluorescent bulbs (supplied by others) and one (1) LED bulb (supplied by Amico). Installation Mounting and final connections are the responsibility of the installing contractor. This includes receiving, storage, erection, overhead bracing, clean up, touch up, and carton disposal. The contractor shall supply all necessary installation materials, including such items as tools, fasteners, calking and electrical lamps. The electrical contractor shall be responsible for the final electrical hook-up at service connection locations, as well as interconnection wiring on multi-sectional units. Once the installation is complete, the electrical contractor shall test equipment function and high voltage services / grounding in accordance with local electrical code requirements. It is the responsibility of the hospital and/or the approval authority to notify Amico if Local electrical code varies or differs from that of NEC. Amico manufactures all products in accordance with NEC (current edition). Optional Equipment Amico Accessories Shall be provided in the quantities and types as ordered. Accessories shall be installed by others, in the locations determined by the end user. Please see the Amico Accessories catalog for additional product and mounting information. Product Code Definition FWXXXX-RC-CAR-P XXXX = Variable Width/Height (e.g. 1907) CAR = Care Level (GEN, ICU, etc) P = Private or Semi-Private (P, S) The medical gas contractor shall be responsible for piping and final connection of all medical gas services. Amico Corporation will manifold medical gas pluming internal to the Headwall System, and provide single point of connection as per the submittal documents. The medical gas contractor shall be responsible for purging, pressure testing, gas identification and system certification in accordance with NFPA 99c (current edition) or CSA-Z7396.01-06. Please refer to the Regal Series Recessed Flatwall installation instructions for further detail. Distributed By: Amico Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada 71 East Industry Court, Deer Park, NY 11729, USA Toll Free Tel: 1.877.264.2697 Tel: 905.764.0800 Fax: 905.764.0862 www.amico.com AC-RSRFW- PRINTED FEB12

Regal Series Surface Mount Flatwalls General Specifications The Amico Regal Series Surface Mounted Flatwall shall be manufactured by Amico Corporation, in accordance with job specific shop drawings and documents. The complete Flatwall assembly shall be culus listed. The following is a general specification, and components listed may not be present or required in final product. The Regal Series Flatwall System is listed by Underwriters Laboratories Inc.(UL) in Canada and the United States of America. This product also complies with the seismic requirements of, and is approved by the State of California s Office of Statewide Health Planning and Development (OSPHD). Amico Corporation manufactures all products in accordance with the National Fire Protection Association (NFPA), NFPA-99c (current edition) and National Electric Code (NEC). The installation contractor is responsible for compliance with all local, state, and federal codes applicable to the installation of medical gas and electrical systems. Submittals and Verifications Job specific shop drawings shall be produced for each project. These shop drawings will clearly indicate the area of Medical Gas termination, and electrical connection points inside or outside the Flatwall System. As Built drawings will be produced, and emailed at the time of shipment. Amico Corporation will manufacture equipment as per signed approval drawings and verifications documents, which are provided in the job specific submittal package. C US LISTED Figure 1. Regal Series 19" (483 mm) Surface Mounted Flatwall

Regal Series Surface Mount Flatwalls Materials and Construction Enclosure shall be constructed of extruded, anodized aluminum alloy sections to provide a modular surface mounted unit with integrated accessory rails for equipment management. Standard sizes of the Regal Series Surface Mounted Flatwall are 19" (483 mm), 28" (711 mm), and 38" (965 mm) widths and can be made to any custom height. Each headwall system shall contain electrical conduit to enclose electrical wiring for each type of power (critical, normal and low voltage/communication). Electrical termination shall be located as indicated in the drawing. All med gas piping shall be hard-piped and brazed to a single point of connection. Med gas pipes will terminate above the ceiling line. All Fascia panels (aluminum and laminated) shall be removable for access for easy installation and maintenance of headwall services. Integrated Accessory Rails The Regal Series Surface Mounted Flatwall has four (4) accessory channels, which are integrated into the aluminum extrusion assembly. The accessory channels are clear etched anodized. Fascia Standard anodized aluminum finish where devices are located. Medium-Density-Fiberboard with High pressure laminate (HPL) elsewhere. Color and pattern to be selected by customer. Medical Gas Outlets Amico Corporation manufactures several compatible connection types for Medical Gas and Vacuum Outlets. The outlet connection type shall be as called for on the signed approval documents. Medical Gas Manifold Medical gas distribution shall be supplied by pipe drops to the single point connection above the unit as indicated on the drawing. All Medical Gas Outlets and piping shall be brazed and tested in accordance with NFPA 99c. All Medical Gas piping shall be Type L copper pipe. Each outlet, piping and manifold shall pass a 24 hour standing pressure test. Electrical Wiring Wire for standard and critical branch power circuits shall be #10 or #12 (as specified) type THHN stranded copper wire, 600 volt, with heat resistant thermoplastic insulation for hot (black) and neutral (white). Grounds shall be #10 type R THHN stranded copper wire (green). All ground conductors shall be installed in conduit. Grounding and Bonding All ground conductors shall be installed in conduit. Each power receptacle shall have a ground conductor connected to a grounding screw. Where electrical terminations are located inside the flatwall, a grounding bus will be installed for each type of power, and shall be installed as to insure grounding for the complete power system. Electrical Receptacles Shall be HUBBELL Hospital Grade 15 or 20 amp, 120 or 277 volt, UL listed and marked Hospital Grade. Quantity and type as shown on drawings. Amico shall furnish and install receptacles with wiring required, as shown on submittal shop drawings. All receptacles shall be HUBBELL hospital grade receptacles. Electrical contractor shall insure compatibility of plug on accessory equipment to be used with these devices: Duplex Receptacles shall be NEMA style 5-15R or 5-20R, color ivory for use on normal power circuits, and color Red for Simplex Receptacles shall be NEMA style 5-15R or 5-20R, color Ivory for use on normal power circuits, and color Red for Safety Receptacles (if required) shall be duplex type, be NEMA style 5-15R or 5-20R, color Ivory for use on normal power circuits, and color Red for use on critical branch power circuits. Receptacles shall limit proper access to energized contracts and shall accept both 2 wire and 3 wire plugs. Locking Receptacles (if required) shall be simplex type, 20 amp, 120 or 277 volt, color black, and be HUBBELL lock 23000 HG style. Low Voltage Data Provisions Shall be connected to device junction box via conduit. Amico Corporation shall include pull cord extending from service provision to electrical termination point. Telephone jack, Blank faceplates, Data port or other Low Voltage device shall be furnished, installed and wired by Low Voltage contractor.

Regal Series Surface Mount Flatwalls Switching Shall be HUBBELL Industrial Grade 120 or 277 volt, 15 or 20 amps. Switch type options include SPST, 3-Way or Momentary, as shown on submittal shop drawings. Low Voltage Switching will be 0-12 volts, 15 amps unless otherwise noted. Amico Corporation shall furnish, preinstall and wire all switches. Lighting (Optional) Direct, Indirect and night light lighting can be provided by the Amico 3' or 4' overbed or ceiling lighting system. These fixtures provide lighting on and above the patient bed. Each fixture shall accommodate three (3) fluorescent bulbs (supplied by others) and one (1) LED bulb (supplied by Amico). Wood Valance (Optional) A decorative wood valance can be added on and between two flatwall units to compliment the room. The wood valance is constructed of particle board with laminate finish, colored to match the flat wall. The integrated light is a 3' fluorescent light with 2 bulbs provide by Amico and will provide reading light above the bed. Installation Mounting and final connections are the responsibility of the installing contractor. This includes receiving, storage, erection, overhead bracing, clean up, touch up, and carton disposal. The contractor shall supply all necessary installation materials, including such items as tools, fasteners, calking and electrical lamps. The electrical contractor shall be responsible for the final electrical hook-up at service connection locations, as well as interconnection wiring on multi-sectional units. Once the installation is complete, the electrical contractor shall test equipment function and high voltage services/ grounding in accordance with local electrical code requirements. It is the responsibility of the hospital and/or the approval authority to notify Amico if Local electrical code varies or differs from that of NEC. Amico manufactures all products in accordance with NEC (current edition). The medical gas contractor shall be responsible for piping and final connection of all medical gas services. Amico Corporation will manifold medical gas pluming internal to the Headwall System, and provide single point of connection as per the submittal documents. The medical gas contractor shall be responsible for purging, pressure testing, gas identification and system certification in accordance with NFPA 99c (current edition) or CSA-Z7396.01-06. Please refer to the Regal Series Surface Mounted Flatwall installation instructions for further detail. Optional Equipment Amico Accessories Shall be provided in the quantities and types as ordered. Accessories shall be installed by others, in the locations determined by the end user. Please see the Amico Accessories catalog for additional product and mounting information. Product Code Definition FWXXXX-SM-CAR-P XXXX = Variable Width/Height (e.g. 1907) CAR= Care Level (GEN, ICU, etc) P = Private or Semi-Private (P, S) Distributed By: Amico Corporation 85 Fulton Way, Richmond Hill, ON L4B 2N4, Canada 71 East Industry Court, Deer Park, NY 11729, USA Toll Free Tel: 1.877.264.2697 Tel: 905.764.0800 Fax: 905.764.0862 www.amico.com AC-RSSMFW- PRINTED FEB12