Circuit Analyzers SureTest Circuit Analyzers Measures voltage drop under load* Hot and neutral conductor impedances Estimates Load on Line (ELL) up to 15A Tests GFCIs and EPDs for proper operation Super-bright display High accuracies True RMS Line voltage Peak voltage Frequency Ground to neutral voltage Ground impedance Identifies proper wiring in 3-wire receptacles Identifies false (bootleg) grounds Conducts testing without disturbing sensitive loads Verifies isolated grounds (with 61-176 adapter) 2-year warranty *12A, 15A, 20A load tests 300V 61-175 61-183 SureTest Circuit Analyzer - Tests AFCIs wiring, tests for shared neutrals SureTest Circuit Analyzer 61-164 Includes Carrying Case 61-179 1 Extension Cord 61-182 Ground Continuity Adapter 61-175 Isolated Ground Adapter 61-176 Alligator Clip Adapter 61-183 Range & Accuracy Resolution AC Voltage 85.0-265.0 VAC 1.0% Frequency 45.0-65.0 Hz 1.0% Impedance 0.00-1.99 Ω 5.0% Ground-Neutral Voltage 0.0-24.0 VAC 2.0% % Voltage Drop 12A, 15A, 20A load tests 0.1% - 50.0% 5.0% GFCI Test Current/Time 6.0-9.0 ma 0.0-6500 ms 2.0% SureTest Circuit Analyzer Functions Voltage Drop NEC recommends no more than 5% voltage drop Higher voltage drop leads to heat buildup and performance issues <108V is a poor level for voltage load Line Voltage Specification is 120VAC +/-10% 61-176 Troubleshoots branch circuit problems with a variety of tests at the receptacle. 61-182 AFCI testing with alligator clips on an installed device. (108 to 132 VAC) True RMS ensures accuracy in harmonic environments Ground-to-neutral Voltage Good circuit has 2VAC or less Higher reading indicates loaded circuit, harmonic distortion or shared neutral Ground Impedance Ground impedance should be 1 Ω or less (0.25 Ω or less for sensitive equipment to run properly) GFCI Applies a 6-9mA fault current and measures the trip time Applies a 30mA fault current to check for equipment protection D-12 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance
AFCI/GFCI Tester Tests AFCIs circuit wiring Tests GFCIs for proper operation Tests for shared neutrals Verifies wiring configuration Compact size fits comfortably in pocket 1-year warranty AFCI/GFCI Circuit Tester 61-059 C-50 w/belt clip 1 Cord Adapter 61-177 Alligator Clip Adapter (3-wire) 61-184 Alligator Clip Adapter (2-wire) TL-532A Carrying Case with Belt Clip C-50 Voltage Performance Monitor Real-time TRMS voltage, frequency and harmonics monitoring Logs voltage, sags, swells and impulses Measures %THD and logs periods over 3% (line to neutral) Selectable thresholds based on the most accepted international standards, defaults to ITIC* Custom programmable event thresholds Invertible display, when it is necessary to plug in upside down 2-year warranty * Captures events that would affect equipment on branch circuit Voltage Performance Monitor 61-830 Applications Monitor voltage near sensitive equipment Installation and Technicians Monitor voltage at point of equipment connection Electricians Eliminate guesswork on service calls Building Maintenance Technicians Identify voltage caused equipment failures Equipment Manufacturers Eliminate unnecessary warranty costs Hospital/IT Maintenance N12966 300V Engineers Monitor voltage quality to critical equipment See voltage through the eyes of your equipment Poor voltage quality increases facility expenses, warranty costs and downtime plus shortens the life of equipment. The IDEAL VPM identifies only those voltage conditions that can damage equipment or cause equipment failure. Analyzers 61-179 Includes Adapters (set of 4) PA-830 Carrying Case 61-179 Alligator Clip Adapters (2-wire) TL-532A 1 ft. US Extension Cord 61-177 Kit with (1) SureTest 61-164, (2) VPM 61-830, Soft Case C-2004 61-2003 Kit with (1) SureTest 61-164, (4) VPM 61-830, Soft Case C-2004 61-2004 61-830 Operating Range 15-265V Memory 513 Events Sampling Method Continuous (128 samples per cycle) Voltage Accuracy 1% Impulse Detection 6µs, 4kV Harmonic Distortion 2%, FFT to 51st PA-830 1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM D-13
Magnetic Strap Test Leads Frees up hands to help work safely Fits 490/480/340 Series Multimeters TL-100 Magnetic Strap 61-565 TL-104 USB Cable Provides safe, easy measurement of AC current Extends the current measurement capabilities of digital multimeters TLF-252 AC milli-volt output (1mVAC = 1mA) Current Clamp Adapter Optical USB Cable for 490 Series s & Software 61-902 Premium Test Leads w/alligator clips Silicone Test Leads Test Leads w/large alligator clip Fused Test Leads w/alligator clips, 10A/600V, CAT III - 1000V TL-100 TL-102 TL-104 TLF-252 600A AC/DC Clamp Adapter - 2 ft. lead length 61-334 AC Current DC Current Output Signal Max Conductor Size 61-334 1 600 A 1 600 A 1mV/A 1.125 (28.5cm) N12966 D-20 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance
Thermocouple Measures up to 1500 F (816 C) K-type thermocouple plugs into digital multimeter voltage jacks with 61-465 adapter 61-461 Beaded K-type Thermocouple 61-461 Thermocouple Adapter 61-465 61-465 Carrying Cases 61-010 C-90 C-290 61-445 Leather Carrying Case - for use with 61-065, 61-076, 61-085, 61-086 61-010 Small Nylon Carrying Case w/four pockets 61-445 Nylon Carrying Case - for use with all Vol-Con and Vol-Test Voltage Testers C-90 Nylon Carrying Case - for use with Digital Multimeters C-290 Carrying Case Selection Guide VOLTAGE TESTERS 160 310 340 360 480 490 610 700 740 760 770 830 61-059 61-065 61-076 61-085 61-086 61-090 61-092 61-096 61-164 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-610 61-614 61-702 61-704 61-744 61-746 61-763 61-765 61-773 61-775 61-830 61-179 Nylon Carrying Case C-50 Nylon Carrying Case C-90 Nylon Carrying Case C-230 Nylon Carrying Case C-290 Nylon Carrying Case C-700 Nylon Carrying Case C-760 Nylon Carrying Case C-770 Nylon Carrying Case 1-800-435-0705 Customer Assistance WWW.IDEALINDUSTRIES.COM D-21
Replacement Parts Selection Guide METER REPACEMENT PARTS SELECTION GUIDE 090 310 340 360 480 490 600 610 700 740 760 770 790 61-096 61-310 61-312 61-340 61-342 61-361 61-484 61-486 61-497 61-498 61-605 61-610 61-614 61-702 61-704 61-744 61-746 61-763 61-765 61-773 61-775 61-795 61-797 Replacement Parts/Safety FUSES F-1 0.5A (250V) 6.35 x 38mm F-105 1A (600V) 10.3 x 35mm F-310 250mA (250V) 5 x 20mm F-312 500mA (250V) 5 x 20mm F-314 10A (250V) 5 x 20mm F-340 0.5A (500V) 6.35 x 32mm F-341 10A (1000V) 10 x 38mm F-497 440mA (1000V) 10 x 35mm F-498 11A (1000V) 10 x 38mm F-797 315mA (1000V) 5 x 32mm LA-3893 2A (600V) 6.35 x 25.4mm LA-3898 0.25A (500V) 5 x 32mm BATTERIES 61-201 1.5V (LR44) 1.5V (AA) 1.5V (AAA) 9V TEST LEADS TL-34 Leads w/pin connectors TL-56 Test leads TL-95 Test leads TL-100 Test leads w/alligator clips TL-102 Silicone test leads TL-104 Test leads w/large alligator clips TL-310 Test leads TL-795 Test leads TL-797 Test leads Safety in the Field The power demands of today s high-tech world have caused a marked increase in occurrences and levels of transient overvoltages. The International Electrotechnical Commission (IEC) has developed a safety standards model for measurement, control and laboratory use. Category I The signal level for telecommunications, electronic and other low-energy equipment with transient-limiting protection. Peak impulse transient range is 600 4,000 volts with a 30 ohm source. Category II The local level for fixed and non-fixed powered devices including appliances, lighting and portable equipment. Outlets located more than 30 feet from CAT III sources and 60 feet from CAT IV sources. Peak impulse transient range is from 600 6,000 volts with a 12 ohm source. Category III The distribution level for fixed primary feeders or branch circuits. Circuits that are separated from CAT IV sources by at least one level of transformer isolation. Peak impulse transient range is 600 8,000 volts with a 2 ohm source. Category IV (proposed) The primary supply level for the highest levels of transient overvoltage. Includes the utility service both outside and at the service entrance, service drop from the pole to the building, overhead line to remote buildings, and underground line to a well pump. Peak impulse transient range is 600 12,000 volts with less than a 1 ohm source. Visit our website for more technical product details, application support, white papers, videos and software! Safety in the Field CAT I Copiers Electronic equipment Low energy equipment with transient limiting protection CAT II Appliances, PCs, TVs Outlets and long branch equipment All outlets at more than 10m (30 ft) from Category III source All outlets at more than 20m (60 ft) from Category IV source CAT III MC Panels Underground Feeders and short branch circuits Distribution panel devices Heavy appliance outlets with short connections to service entrance Outbuilding Transformer Outbuilding Underground CAT IV Exterior Transformers, s Outside and service entrance drop from pole to building Overhead line to detached building Underground line to well pump D-22 WWW.IDEALINDUSTRIES.COM 1-800-435-0705 Customer Assistance