Measurement and Analysis for Switchmode Power Design

Similar documents
Switched Mode Power Supply Measurements

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

Today most of engineers use oscilloscope as the preferred measurement tool of choice when it comes to debugging and analyzing switching power

Power Measurements for Switch-Mode Power Supplies SAVE Verona 2011

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

Probe Considerations for Low Voltage Measurements such as Ripple

Memo. 1 Summary. 1.1 Introduction. 1.2 Experiments. 1.3 Conclusion

CONNECTING THE PROBE TO THE TEST INSTRUMENT

LeCroy PowerMeasure System. Get the Complete Picture

IsoVu Optically Isolated DC - 1 GHz Measurement System Offers >120 db CMRR with 2kV Common Mode Range

Techniques to reduce electromagnetic noise produced by wired electronic devices

Practical Measurements considerations for GaN and SiC technologies ANDREA VINCI EMEA MARKET DEVELOPMENT MANAGER POWER ELECTRONICS

Power Measurements and Analysis: Challenges and Solutions

9 Specifications. Specifications NOMINAL CHARACTERISTICS

Understanding and Optimizing Electromagnetic Compatibility in Switchmode Power Supplies

Experiment 1: Instrument Familiarization (8/28/06)

Experiment 1: Instrument Familiarization

Superior Measurements with a PXI Differential Amplifier

Measuring Power Line Impedance

TT-SI MHz Active Differential Probe

Isolation Addresses Common Sources of Differential Measurement Error

200 ma Output Current High-Speed Amplifier AD8010

Trees, vegetation, buildings etc.

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

Conventional Single-Switch Forward Converter Design

TT-SI 9001 / TT-SI MHz Active Differential Probes

1. High Frequency Performance

Device Interconnection

Analogue circuit design for RF immunity

TAKE THE MYSTERY OUT OF PROBING. 7 Common Oscilloscope Probing Pitfalls to Avoid


PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

Saturation of Active Loop Antennas

OVP 2:1. Wide Range. Protection

Specify Gain and Phase Margins on All Your Loops

Testing Power Factor Correction Circuits For Stability

Measuring Power Supply Switching Loss with an Oscilloscope

High Speed BUFFER AMPLIFIER

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

Probing for oscilloscope

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

Sophisticated Power Loss Analysis Using A Digital Phosphor Oscilloscope

Op-Amp Simulation Part II

TT-SI MHz DIFFERENTIAL PROBE

Electromagnetic Compatibility

CS101. Conducted Susceptibility CS101. CS101 Maximum Current. CS101 Limits. Basis For CS101 Limits. Comparison To MIL-STD Vdc or Less

Appendix A: Specifications

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

External Drive Hardware

Vishay Siliconix AN724 Designing A High-Frequency, Self-Resonant Reset Forward DC/DC For Telecom Using Si9118/9 PWM/PSM Controller.

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

ECE3204 D2015 Lab 1. See suggested breadboard configuration on following page!

CHAPTER 4 MEASUREMENT OF NOISE SOURCE IMPEDANCE

Reduce Load Capacitance in Noise-Sensitive, High-Transient Applications, through Implementation of Active Filtering

Impact of the Output Capacitor Selection on Switching DCDC Noise Performance

results at the output, disrupting safe, precise measurements.

ELC224 Final Review (12/10/2009) Name:

Differential Amplifiers

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

MIC2296. General Description. Features. Applications. High Power Density 1.2A Boost Regulator

Application Note 5121

FEATURES TYPICAL APPLICATIO. LT1194 Video Difference Amplifier DESCRIPTIO APPLICATIO S

Using X-Y Displays APPLICATION BRIEF LAB WM312. May 29, Introduction. Summary

TT-SI MHz Active Differential Probe

Power Supply Measurement and Analysis Primer

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

LM6118/LM6218 Fast Settling Dual Operational Amplifiers

KM4110/KM mA, Low Cost, +2.7V & +5V, 75MHz Rail-to-Rail Amplifiers

MD 200A High voltage differential probe

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

HA MHz, High Slew Rate, High Output Current Buffer. Description. Features. Applications. Ordering Information. Pinouts.

Guide Version Five techniques for fast, accurate power integrity measurements

CONTENTS. Chapter 1. Introduction to Power Conversion 1. Basso_FM.qxd 11/20/07 8:39 PM Page v. Foreword xiii Preface xv Nomenclature

Model Operating Manual

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

Single Supply, Low Power Triple Video Amplifier AD813

EMI Filters Demystified. By William R. Bill Limburg February 21, 2018 Phoenix Chapter, IEEE EMC Society

OPERATIONAL AMPLIFIER PREPARED BY, PROF. CHIRAG H. RAVAL ASSISTANT PROFESSOR NIRMA UNIVRSITY

ECEN 474/704 Lab 6: Differential Pairs

MIW3000 Series EMI. 5-6W, Wide Input Range DIP, Single & Dual Output DC/DC Converters MINMAX. Block Diagram. Key Features

DECLARATION OF CONFORMITY

Keysight Technologies How to Make the Best Switch Mode Power Supply Measurements. Application Note

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

University of New Hampshire InterOperability Laboratory Gigabit Ethernet Consortium

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

University of Pittsburgh

Investigation of a Voltage Probe in Microstrip Technology

Transformer Waveforms

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

EMC Pulse Measurements

Operator s Manual. DA1855A Differential Amplifier

Fluke 192/196/199. ScopeMeter. Users Manual

Testing and Verification Waveforms of a Small DRSSTC. Part 1. Steven Ward. 6/24/2009

Quick Start RSDPB5000/RSDPB4000. High Voltage Differential Probe Series

New Technique Accurately Measures Low-Frequency Distortion To <-130 dbc Levels by Xavier Ramus, Applications Engineer, Texas Instruments Incorporated

INVESTIGATION AND DESIGN OF HIGH CURRENT SOURCES FOR B-H LOOP MEASUREMENTS

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Transcription:

Measurement and Analysis for Switchmode Power Design

Switched Mode Power Supply Measurements AC Input Power measurements Safe operating area Harmonics and compliance Efficiency Switching Transistor Losses Measurement challenges Transformer B-H curve Dynamic Control Loop Step load and start up behavior Output Ripple

AC Input Line Power and Harmonics AC In + + DC Out PWM Controller Feedback

Line Voltage Line Current Line Power RMS line voltage, RMS line current, real power, apparent power, power factor and crest factor

A

Line Harmonic Analysis Line harmonics can be measured against compliance standards like EN 61000-3-2

Power supply efficiency measurement

Safe Operating Area Mask Testing

Switched-Mode Power Supply AC In + + DC Out DC AC PWM Controller Feedback The measurements we will talk about here are useful for any inverter based power conversion device

Energy Loss Loss displayed in Joules

Power Loss Loss displayed in Watts Power = Energy / Time

Conduction Loss Measurement Challenge Although the peak to peak waveform may be hundreds of volts, during the conduction stage the voltage is close to zero. Measuring the conduction loss or dynamic on resistance is a challenge due to the limited dynamic range of the oscilloscope

Current Saturation Voltage Conduction Region Conduction Region Parameter Gate ParameterGate Power Conduction Conduction Generally it is not possible to measure total cycle loss in the same waveform capture. Measurement challenge: Why will this setup produce an incorrect switching loss measurement for the complete switching cycle?

The Challenge of Power Measurement Upper V GS measurement required between point A and B +175 Volts A B Output? - 175 Volts

A Minus B Method Both A & B must be on screen. This determines the maximum sensitivity the oscilloscope can be set at. Limited channel accuracy matching severely limits the ability to Reject (Subtract) the signal that is Common to both A & B. Line Voltage 1 W Shunt Load Circuit Scope remains safely grounded Channel A - Channel B is not adequate when: The Common Mode Voltage >> Voltage Being Measured Because oscilloscope amplifiers and passive probes are not precisely matched for higher frequency gain (or attenuation), CMRR above a few khz will be very low.

Ground Referenced Need for Differential Ground referenced measurements upset by alternate ground path low amplitude signals Currents in the ground distribution system result in Ground is not ground syndrome Common problem when using coaxial shunts Noise in the system can be >> signal of interest Moving the ground ground closer to the device will result in an alternate ground path and large circulating currents in the probe ground lead V+ V+ + I I v - I

Floating the Scope Floating the scope can result in a shock hazard, damage to the DUT, damage to the scope and poor measurement accuracy. If the reference voltage connected to the probe ground lead is high enough, conductive surfaces of the scope, including the ground leads of other probes can become shock hazards If an insulation fault were to occur in the primary wiring of the scope, it could raise the front panel of the scope to line potential. If the reference voltage is large, there is a possibility of damaging components in the scope power supply or power line filter from the dielectric breakdown. This type of damage may not show up immediately, but appear later even after the scope is returned to grounded operation. The capacitance between the scope case and earth ground can result in damage to the device under test when the probe ground lead loads the circuit with the full capacitance between the scope case and ground. The scope ground is a discharge path for radiated EMI, and with the scope ground severed, radiated EMI from the scope may intefere with the measurement. Measurement corruption can occur when the ground lead inductance acts on the capacitance to ground to create a series LC resonant circuit which resonates with the common mode signal. Because this capacitance is much larger than the scope input C, the resonant frequency is much lower. Thus, when measured with a floating scope, the waveform of a typical upper gate drive signal often has a significant ring which is really not present in the true signal. This measurement distortion is large enough to make many routine measurements, such as upper gate drive, virtually impossible.

Using Differential Amplifiers CMRR 100,000:1 Overdrive recovery <100 ns Differential Amplifier Line voltage at 400 V full scale (with 8-bit resolution) Line voltage waveform crest at 2 V/div (with 8-bit resolution) Differential Amplifier connected to oscilloscope

Transition Losses and Conduction Loss Due to the wide dynamic range of voltage, different vertical sensitivities are needed to accurately resolve conduction loss and turn-on/turn-off loss Voltage waveform at 50 V/Div Voltage waveform at 200 mv/div To measure a device s saturation voltage to 100 mv accuracy when the off voltage is 400 V requires 250 ppm measurement capability The signal conditioning must have linear performance far better than required by an 8 bit digital oscilloscope

Solution 1: Overdriving the Signal Differential probe response is very slow to stabilize, and never reaches the correct saturation voltage level Differential amplifier response rapidly stabilizes and reaches the correct saturation voltage level Differential Amplifier Differential Probe

Using Differential Amplifier for Saturation Measurements CMRR 100,000:1 Overdrive recovery 400 V to 100 mv <100 ns Precision Offset Generator 0.5% DA1855A Differential Amplifier Differential Amplifier connected to oscilloscope

Using High Definition Oscilloscopes 12-Bit Capture 8-Bit Capture

Using High Definition Scope with High Accuracy Probes 12-Bit Capture, 1% accuracy Probe 12-Bit Capture, Standard Probe

Example Hardware Configuration Voltage and current probes to match the accuracy of HDO scopes High voltage differential probes with high accuracy and high CMRR. Current probes offer high accuracy and low noise. CP030A and CP031A HVD3102 and HVD3106

Rds On Resistance Measurement Overdrive recovery of differential amplifier and high resolution oscilloscope combination

Eliminating Sources of Error DC Offsets, Deskew Before making detailed device loss measurements, fine adjust to eliminate DC offset errors and scope probe propagation delay differences

Two Ways to Fine Adjust Current Probe DC Offset During Off-state, utilize Math integral function and adjust for zero slope Utilize Power Analyzer s automatic calculation of Off-State Losses and fine adjust to zero

Deskewing Voltage and Current Probes Use a deskew calibration source, with V and I coincident edges, to remove propagation delay differences between voltage and current probes Line up the knee of the curve to deskew for power measurement

Sources of Error Skew Between Voltage and Current Probes Timing skew between voltage and current probes results in measurement error Device turn-off transition loss, V x I, is properly measured at 7.88 uj of energy versus 13.43 uj without proper deskew

Switched-Mode Power Supply AC In + + DC Out PWM Controller Feedback The transformer provides isolation between the power supply input and output

Power Analyzer BH Curve

Power Analyzer BH Curve

BH Curve Definition

Voltage Current B= V(t)dt H = ni l B-H Curve shows the hysteresis loop for the magnetic material in inductors and transformers Coil Characteristics Input: # of windings Cross sectional area Magnetic path length Cursor are used to measure magnetic field strength, H, and magnetic flux density, B H is calculated from the current, # windings and magnetic path length B is calculated as the integral of the voltage across the coil Parameter math is utilized for calculation of the magnetic permeability of the material B and H constants are individually entered and the resulting parameter is calculated as B/H

Control Loop Measurements AC In + + DC Out PWM Controller Isolated Feedback

Cycle 1 Period Cycle 2 Period Cycle 3 Period Cycle 4 Period Cycle 5 Period Cycle 6 Period Cycle 7 Period Cycle 8 Period Cycle 9 Period Voltage 2.001 ns 2.004 ns 1.991 ns 2.001 ns 1.999 ns 1.995 ns 2.008 ns 1.986 ns 2.001 ns Time Period 2.001 ns 2.004 ns 1.991 ns 2.001 ns 1.999 ns 1.995 ns 2.008 ns 1.986 ns 2.001 ns Time Parameter Track can be used to determine power supply modulation

Pulse width begins to decrease Load disconnected Track function plots changing pulse width Settling time

Control Loop Measurements AC In + + DC Out PWM Controller Isolated Feedback

Power supply ripple measurement

Radiated Immunity Testing

Radiated Immunity Testing - Real Time Functional Performance Evaluation Deviation detection of a device under test (DUT) during exposure to a disturbance Functional state of the DUT is output through non-conductive fiber optic cables Mechanical mode tuner Devices under test are exposed to electric fields high enough to effect operation of nonshielded equipment. Transmit and receive antennas generate a controlled electric field RF-hardened fiber optic transmitters

Outside the reverberant chamber, oscilloscope masks test for acceptance criteria Optical receiver and O/E converter 16 channels performing mask test criteria such as signal high level, signal low level, frequency, duty cycle, and other criteria fit within tolerance limits described in the test plan

High Voltage Fiber Optically-isolated Probe? Amplifier/Modulating Transmitter A frequency modulating optical transmitter is used for signal and data transmission across a fiber optic cable. Attenuating Tip Accessories Available in a variety of voltage ranges, e.g., +/-1V, +/-5V, +/-20V and +/-40V with a simplified pin socket termination Fiber Optic Cable A standard 1m length cable is provided, but longer ones may be purchased for use. De-modulating Receiver The optical signal is received and de-modulated to an electrical output to the oscilloscope with correct voltage scaling.

High Voltage Active Single-ended (Fiber Optic) Probes Parameter Bandwidth Voltage Range (SE) Voltage Range (CM) Loading Attenuation CMRR Value 60 MHz 2 to 80V Virtually Unlimited 1-10MΩ 34-22pF Z IN =50kΩ@100 khz 2x to 80x >140 db A new topology specifically for measuring small signals floating on a HV DC bus