Continuous Monitoring on the SSE Networks Transmission System

Similar documents
INTEGRATED TRANSMISSION PLAN Glossary

NETS SQSS Modification Proposal

Transmission Innovation Strategy

EI HIGH VOLTAGE INSULATION TESTING POLICY

EPS AUSTRALIA SERVICES HV TESTING & COMMISSIONING CAPABILITY

6 th December South West Scotland Forum

Transmission Innovation Strategy

Trans Bay Cable A Breakthrough of VSC Multilevel Converters in HVDC Transmission

ECP HV INSULATION TESTING

Fundamental Concepts of Dynamic Reactive Compensation. Outline

Condition Assessment of High Voltage Insulation in Power System Equipment. R.E. James and Q. Su. The Institution of Engineering and Technology

ECP HV INSULATION TESTING

Presentation Overview. HVDC Transmission - Opportunities and Challenges. Characteristics of HVDC. Characteristics of HVDC

Introduction to HVDC in GB. Ian Cowan Simulation Engineer 12 March 2018

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Publishing date: 23/07/2015 Document title: We appreciate your feedback. Share this document

CIGRE General Session, Paris 2014 Group Meeting SC B1 Insulated Cables, 27th August, 2014 Results of CAG Questionnaire

Orkney Electricity Network Reinforcement Stakeholder Consultation Response. August 2014

PD Solutions. On-Line PD Measurement Devices

NETWORK INNOVATION COMPETITION ANGLE-DC PROJECT HOLISTIC CIRCUIT CONDITION MONITORING SYSTEM REPORT

ORKNEY CAITHNESS CONNECTION

Experience with Connecting Offshore Wind Farms to the Grid

SPTS 1 - Ratings and General Requirements for Plant, Equipment and Apparatus for The ScottishPower System and Connection Points to it.

Jason Harchick, P.E. Sr. Manager, System Planning and Protection Ryan Young Manager, Substation Engineering

Power transformers. Shunt reactors Proven history for future success

Dynamic Series Compensation for the Reinforcement of Network Connections with High Wind Penetration

ESB National Grid Transmission Planning Criteria

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Shetland HVDC Link Project. Consultation, August 2016

A New Approach for Transformer Bushing Monitoring. Emilio Morales Technical Application Specialist Qualitrol

Enabling Array Cable Cost Reduction

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Onsite Mobile AC High Voltage Test System

Emerging Subsea Networks

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

ABB AG - EPDS. I S -limiter The worldʼs fastest limiting and switching device

Grid integration of offshore wind farms using HVDC links: HVDC-VSC technology overview

Subsea Electric Power Grid

RELEVANT ELECTRICAL STANDARDS

BAY OF SKAILL SUBSTATION - ORKNEY CAITHNESS CONNECTION

IRIS POWER PDTracII. Continuous On-line Partial Discharge Monitoring for Motors, Generators, Dry Type Transformers, and Air-Insulated Switchgear.

A COMPARISON OF AC AND DC PARTIAL DISCHARGE ACTIVITY IN POLYMERIC CABLE INSULATION *

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section SCADA Technical and Operating Requirements

Specialists in HV and MV test and diagnostics. Testing in Substations

OMICRON Seminar on Partial Discharge Diagnostics on HV Assets. January 30, 2018 Beirut, Lebanon

Requirements for Generators European Network Code High Level Implementation Issues

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

RELEVANT ELECTRICAL STANDARDS

POWER SYSTEM SOLUTION PROVIDED BY FACTS AND HVDC

Presentation of CIGRE activities on Power Transformers. C. Rajotte (CA) Chairman SC A2 "Transformers"

Testing of 400 kv GIS

Integration of Wind Generation into Weak Grids

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Scottish Hydro Electric Transmission Limited Keeping the lights on and supporting growth Our strategy for a smarter network

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Offshore Renewable Energy Catapult

Operation of a Three-Phase PWM Rectifier/Inverter

Caithness Moray HVDC Link Offshore Installation Public Engagement Event

SSE Offices, Glasgow and Teleconference

AORC Technical meeting 2014

Utility Interconnection and System Protection

ETSU V/06/00187//REP; DTI Pub/URN 01/799 (for Ove Arup reference:

ADDENDUM. (1) Ref. Regulation 33.4 (Page 643): (2) Ref. Regulation 71.2 (Page 676): Annexed as Appendix II to these Regulations at page 697.

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Long Distance Subsea Power Transmission and Distribution

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

DE-PRIME GLOBAL SERVICES LTD DE-PRIME GLOBAL SERVICES LTD. ADDRESS: 1 Echendu Chinwo Close, Chukwuodara Rumoudara, Port Harcourt, Rivers State.

Test systems made by SebaKMT. Don t stress over tests! SebaKMT has the right answers: reliability, speed, economy.

East-South HVDC Interconnector II, India : in commercial operation since 2003

Distribution Fault Location

Subsea Power Grid Control System

Western Isles HVDC Link Consultation

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Digital Fault Recorder Deployment at HVDC Converter Stations

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

INSTRUMENT TRANSFORMERS. Product Spectrum

ATC s Mackinac Back to Back. Summary

System grounding of wind farm medium voltage cable grids

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

A comparison of AC and HVDC options for the connection of offshore wind generation in Great Britain

Scottish Hydro Electric Transmission Plc

Oscillatory Stability: Extended Range & Enhanced Source Location

NSRI/ORE Subsea Technological Challenges in Offshore Wind

Offshore wind. A new journey, a proven track record

IRIS POWER TGA-B. Periodic Online Partial Discharge Monitoring Instrument for Turbine Generators and Motors

Subsea infrastructure in MRE ICOE November 6, By Don Bryan, BSc, MBA General Manager Pacific Northwest Operations

Monitoring Solutions For Power Transformers, Reactors, Bushings and Instrument Transformers

Single Line Diagram of Substations

PTTS series. Power Transformer Test System. Scope of Work:

Guidance for UK Fire and Rescue Services. Dealing with incidents on or near National Grid high voltage overhead lines

PAPER. Dry-type transformer innovation: HiDry 72 for subtransmission lines

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

ATTACHMENT - AESO FUNCTIONAL SPECIFICATION

Offshore Wind Risks - Issues and Mitigations

Transcription:

10 th Universities High Voltage Network Colloquium 18 th - 19 th January 2017, GCU, Glasgow, Scotland Continuous Monitoring on the SSE Networks Transmission System The Need for Standards, Specifications & Innovation Dr. Gerry Cleary, Scottish & Southern Electricity Networks 1

Continuous Monitoring on the SSE Networks Transmission System The Need for Standards, Specifications & Innovation Dr. Gerry Cleary, January 2017

Career History Dates Experience Description 2000-2003 R&D University of Strathclyde Partial Discharge Detection in Power Transformers using UHF Monitoring 2003-2004 ScottishPower Secondment - Plant Monitoring on the ScottishPower Transmission Network 2004-2015 Power Systems Project & Consultancy Services (PCS), Hyder & Arcadis Fast Transient Analysis & Insulation Co-ordination Studies, Harmonic Studies and Earthing Measurement & Design 2015-Present SSE Networks Technical Standards Engineer - Standards, Specifications & Innovations 3

Agenda Safety- Priority - if it is not safe we don t do it Role of Standards, Specifications and Innovations Team Why Innovate? Advanced Technologies on the SSE Transmission Network Overview of Caithness Moray HVDC Scheme Continuous Monitoring on the SSE Networks - Transmission System Case Study: Keith Substation Partial Discharge Monitoring Project Next Steps Q&A 4

Need for Standards, Specifications & Innovations Safety Standards Specifications Stakeholder Engagement Clear Definition Level of Detail Innovations Source: IE&T, November 2016 Why Innovate? Responsibility to Deliver Power and Manage Transmission System Provide Value for the customer Regulated Industry Encourages Innovation (RIIO: Revenue = Incentives + Innovation + Outputs) 5

Site Practicalities Specification & Discussion are Key Network Reinforcement: System Planning Optioneering Site Selection: Substn. A & B Route Selection: Subsea Surveys & Third Parties Safety, Environment & Legal Specification (Cable) Installation & Mechanical Protection Port Glasgow Greenock Dry Dock: Pipe Laying Ship Commissioning, On-Line Monitoring & Repair 6

Some Examples of Advanced Technologies on the SSE Network HVDC: Caithness - Moray SVC (Static VAr Compensator) MSCDN (Mechanically Switched Capacitor Damping Network) Composite Poles for Overhead Lines Gas Insulated Switchgear Gas Insulated Busbar Subsea Cable Circuits 7

Subsea Cable Transmission Circuits System Design System Planning Accurate Specification is Critical Safety, Logistics, Cost, Performance Stakeholders: Electrical, Civil, Environmental, Operational, Consultants, Contractors & Other Suite of Specifications: from Subsea Cable Surveys, Cable System Design, Installation, Testing & Maintenance Operation & Repair of Emerging Technologies References [1] SSE Press Release, Keeping the Lights On. [2] Nexans, O Angoulevant, Offshore Cables 8

Overview of HVDC (Caithness-Moray ) Potential Advantages Some Challenges [1] Reduced Visual Impact [1] Rapidly Changing Technology [2] Control (Frequency, Power Flow & Stability) [2] Difficult to Standardise [3] Reduced Short Circuit Currents on AC System [3] Cost of Converter Stations [4] Connection of Asynchronous Grids [4] Operation & Maintenance Indicative distances - to be confirmed on a per project basis References [1] Electrical Engineering Portal, Costs of HVDC Transmission [2] ABB, HVDC Technical Brochure 9

Overview of Blackhillock Substation ~ 1.1B Investment, ~100 miles of cable 400kV (GIS), 132kV (GIS), 275kV (AIS), BOWL (Offshore Wind) HVDC Converter Station References [1] Blackhillock Substation Early Construction Stage 10

Partial Discharge (PD) Testing & Continuous Monitoring PD Testing at Commissioning PD Testing: Initial Site Investigation PD Monitoring: Milton of Craigie, Keith & Tealing Substations Potential for Further PD Monitoring? Gas Monitoring Distributed Temperature Sensing (DTS): Kintyre Hunterston Subsea Cable Fault Recorders Harmonic Recorders 11

Case Study: Keith Substation Partial Discharge Monitoring Project Site Selection Substation Wide Monitoring HFDE, Elimpus & HVPD Acquisition of PD Signals Asset Management 12

Next Steps: Gather Lessons Learned Specification Refinement Interaction of AC & DC Systems Impact of Long Subsea Cable Circuits Operation & Repair of Emerging Technologies Condition Monitoring Telecommunications Infrastructure 13

Any Additional Questions & Answers? 14