C-M TMR Products Index

Similar documents
Pipe Product Catalog Table of Contents

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

Flanged Dowel Box. Load Transfer System INDUSTRIAL SLAB ON GROUND

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Current Standard Plates including Transmittal Letters are available on the web at:

PERFORM WITH PRECISION MAGNETIC PRODUCTS FOR PRECASTING CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

Cooke Precast Concrete

New Product Release: October 2014 Boone Racks

BASEBALL FOUL POLES SURFACE MOUNTED

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

PD 3 Dowel Cradle. Load Transfer System Industrial Slab on Ground

Current Standard Plates including Transmittal Letters are available on the web at:

Diamond Dowel. Load Transfer System INDUSTRIAL SLAB ON GROUND

CONCRETE MANHOLES.

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

INSTALLATION INTRUCTIONS

TIMARU DISTRICT COUNCIL 2 King George Place P.O. Box 522 Timaru 7940 Telephone: Website:

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS

Job no. 5241_Accessories Brochure_Size: 8.2 x 8.2 _ KOHLER Genuine Accessories

STRUCTURES FOR SANITARY AND STORM SEWERS

BEST PRACTICE GUIDE. Socket Bases. Working with Concrete Slabs

civil product range JUNCTION BOXES DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS

STRATUS SHELTER. Take bike parking to new heights

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

SECTION 39 - MANHOLES TABLE OF CONTENTS

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Hyper ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND

Safe and secure Dero

Manholes Table of Contents

Big expertise. Real convenience. Concrete commitment. stem

Z1035, Z1036, & Z1903 FLOOR DRAIN & CLEANOUT INSTALLATION STABILIZER

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

Barrier posts of steel tube Ø 76 mm, Ø 89 mm, 70 x 70 mm

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

SRIS-001 Arista Mounting System Instruction Sheet Solar Rooftop Support Ballasted

Tree protection systems 2.0

Dura-Lock Roof System

Installation Instructions

Highway Care Ltd. Xtension 110 P4 Terminal & Xtension 110 Double Sided P4 Terminal DESIGN, INSTALLATION & MAINTENANCE MANUAL REVISION 1E

Midwest Roadside Safety Facility

SECTION MANHOLES

5. Outdoor equipment. Barrier posts. Stainless steel

B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422

Gable HomeshedsTM INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE LARGE SPAN. Council Approval. Before Starting

KOLO SHELTER Installation Instructions Parts List

Bollards, Column Guards, Corner Guards, Wheel Stops, Speed Humps & Fixings. Lockinex. ea i, ea u i

4200 JSP, KSP, LSP and MSP Cabinets

Plate 60 ArmourMate. Joint Edge Protection INDUSTRIAL SLAB ON GROUND. Plate 60 AmourMate. Joint Edge Protection

Wheeler Rex Ashtabula, Ohio Tel: Fax:

MODEL NO.: MI / 42100

HEAVY DUTY WEIGH FEET KIT. Installation Instructions

MODEL No: GSS3030G. Model No:...GSS3030G Overall Size (W x D X H*) x 3000 x 2100mm Roof Type:...Gable *Minimum Wall Height

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

STEEPLE GATE BARRIER SET INSTRUCTIONS

Leveling Feet, Base Plates and Casters

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

Outdoor equipment. Barrier posts. Stainless steel. Barrier elements. Barrier poles. Outdoor equipment - pages

Connect Transit Shelter

STOPS. TRIMCO# 1207 B 2-1/4 P 3-3/4 EYE 7/8 x 2-1/4 HOOK 2-3/4 BHMA L01351

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER

CITY OF VISTA STANDARD DRAWINGS

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

Not including the type of fabric used (clear pvc or shade mesh), there are three main types of side screen.

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.

One-sided rack, hot-dip galvanized Space between bicycles 350 mm length approx.kg Part-No. Two-sided rack, hot-dip galvanized

Mounting instructions SZ210 Full-frame pedestal with screw-on tube with placement hinge, for type SCHATTELLO

SM-RAZOR-T-M/L/XL. Strong Low Profile Tilt Mount for Ultra-Thin Flat-Panel TVs INSTRUCTION MANUAL

1. CONNOLLY KEYJOINT 1. PRODUCT NAME 2. SUPPLIER 3. PRODUCT DESCRIPTION 4. KEY FEATURES 5. FIXING INSTRUCTIONS 6. SPECIFICATIONS 7.

REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE

Cooke Precast Concrete

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

SM-RAZOR-F-M/L/XL. Strong Low Profile Fixed Mount for Ultra-Thin Flat-Panel TVs INSTALLATION MANUAL

Kwik-Lock. Installation Instructions. Attention Dealers: Please give this owners manual to the customer when the product is delivered.

Installation Instructions

The New Unrivalled SRB Titan Magnet Clamps & Spartan Composite Adjustable Sideforms

3. Barrier elements. Barrier posts. Stainles steel

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications

INSTALLATION, OPERATION & MAINTENANCE. Adjustable Horizontal Water Closet Carrier

GENERAL ELEVATION SECTION A-A

Depending on the size you ordered you will have either 5 Foot sections which will build the 10 Foot frame or 6 Foot sections which will build the 12

A = 4-1/2 B = 1/4 C = 5/16. Pin Dia. Use with C-11, C-12, C-13, C-19 Use with C-10, C-12, C-13, C dia. A = 4-1/3 A = /16 1-5/8

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

Transcription:

C-M TMR Products Index TMR Dwg. No. Grate/Frames 9x6 Dwg. AS3996 Recessed Road Gully Units Dwg. 1443, 1444 Protruded Road Gully Units Dwg. 1443, 1444 1220 Road Gully Units Dwg. 1459 7x4 Road Gully Units Dwg. 1443, 1444 Type 28 Road Gully Units Dwg. 1445 Drainway Units Dwg. 1321, 1322 Field Inlet Type 1 Dwg. 1309, 1310 Manhole Roof Slabs Dwg. 1308 Lintels Dwg. 1313 Batter Chutes Sub Soil Components Dwg. 1116 Sloping Headwalls Q-Seal Headwalls Dwg. 1243 Box Culverts Box Culvert Integrated Headwall Interlocking Kerbs Wheelstops Light Pole Bases Dwg. 1393

Auto Lock Grate & Frame 900x600 Class D Bicycle Safe to AS3996 990mm (Grate) 1080mm (Frame) 75mm 570mm (Grate) 605mm (Frame) Lift this Side to Disengage Lock Auto Lock The grate will not close until the Auto Lock is disengaged.

C-M 'RECESSED TYPE' ROAD GULLY UNIT 24 SERIES RGU (ALIGNMENT USING KERB LIP) 'LIP IN LINE' 2400 RGU MODEL L24R RGU MODEL R24R GRATES BIKESAFE DESIGN TO AS 3996-92 OR TYPE 'A' RGU MODEL C24R 400 Cross Section at rear of grate Model 24R Aust. Reg. Design No. 120789 Patent No. 602076 Side Section Model 24R

C-M 'RECESSED TYPE' ROAD GULLY UNIT 36 SERIES RGU (ALIGNMENT USING KERB LIP) 'LIP IN LINE' RGU MODEL R36R RGU MODEL C36R GRATES BIKESAFE DESIGN TO AS 3996-92 OR TYPE 'A' Cross Section at rear of grate Model 36R Aust. Reg. Design No. 120789 Patent No. 602076 Side Section Model 36R

C-M 'RECESSED TYPE' ROAD GULLY UNIT 48 SERIES RGU (ALIGNMENT USING KERB LIP) 'LIP IN LINE' GRATES BIKESAFE DESIGN TO AS 3996-92 OR TYPE 'A' Cross Section at rear of grate Model 48R Aust. Reg. Design No. 120789 Patent No. 602076 Side Section Model 48R

C-M 'PROTRUDED TYPE' ROAD GULLY UNIT 24 SERIES RGU (ALIGNMENT USING KERB FACE) 'KERB IN LINE' Also available in 3.6m and 4.8m Series RGU Model L24P Grates: Bikesafe Design to AS3996 or Type A RGU Model R24P Side Section Cross Section at rear of grate RGU Model C24P Aust. Reg. Design 120789 Aust. Patent No. 602076

C-M ROAD GULLY INLET UNIT R.G.U. 1220:Anti-Ponding Class D Bikesafe grate 900 x 600 wide to AS 3996-92 R.G.U. 1220mm (9 x 6 Grate) Model M12 R.G.U. M12 is used to upgrade previous 1220 system. Internal Pit Size 835 x 930. 140 Ideal where space is limited for gully inlet unit......driveway...car park...townhouse development

C-M ROAD GULLY INLET UNIT TYPE 24R 74 RGU Type L24 R74 2400 RGU Type C24 R74 RGU Type R24 R74 SECTION A-A Patent Products 74 Class D CONCRETE TO AS 3902 CASTINGS TO AS 1830 REINFORCING TO AS 1302 AUST. PATENT NO. 602076 AUST. REG. DESIGN No. 120789

C-M CONCRETE TYPE 28 ROAD GULLY UNIT Manufactured in accordance with associated product drawings MRD 1443, 1444, 1445 and 1459 Right Hand Left Hand Centre Class D Bikesafe Grate. Design to AS 3996-92 Side Section Notes: 1.3T Swiftlift Anchors to AS4680 Concrete S40 20 to AS3600 Casting Monolithic Reinforcing, Minimum Cover 40mm to AS4691 (Reference Standard Drawing MRD 1445 Type 28)

Model: 0TC0T 1350 Typ Model: 1T0C0T C-M Drainway System (Monolithic) QDMR Standards 1321-1322 IPWEA Standards D0067 Suits 1050-2100 Shafts All Units Fitted with Vaned Grates or as Specified No Convertor Slab Required for 1050 Shaft Model: 1TC0T Convertor Slabs Shaft Off Set 1200 475 1350 550 1500 625 1800 775 2100 925 Model: 1TC1T Model: 0TC1T Model: 0TC1T Chamber and Trough 2700 Typ 700 Typ 4050 Typ Model 0TC0T 1TC0T 0TC1T 2TC0T 0TC2T 3TC0T 0TC3T 1TC1T 1T0C0T Description Chamber Unit Only Left Hand Trough and Chamber Right Hand Trough and Chamber 2 x Left Hand Trough and Chamber 2 x Right Hand Trough and Chamber 3 x Left Hand Trough and Chamber 3 x Right Hand Trough and Chamber Sag Trough and Chamber Trough 576 Typ Patent Pending

Field Inlet Type 1 - TMR Notes: 1. Concrete S40 TMR 2. Reo: F72 Mesh, Y12 Lig 3. Galvanised Grate & Frame as Specified to AS3996 - Class B 4. 50mm Clear Cover 5. Opening Size: 900x600 or 600x600

C-M Precast Manhole Roof Slabs Manufactured to TMR, IMEAQ or Council Standards Available Sizes: 1130mm O.D Private Property 115mm Thick 1350mm O.D (1050 I.D) 175mm Thick 1500mm O.D (1050 I.D) 200mm Thick 1500mm O.D (1200 I.D Sewer) 200mm Thick 1650mm O.D (1200 I.D Stormwater) 200mm Thick 1700mm O.D (1200 I.D) 200mm Thick 1800mm O.D (1350 I.D) 200mm Thick 1950mm O.D (1500 I.D) 200mm Thick 2250mm O.D (1800 I.D) 250mm Thick 2550mm O.D (2100 I.D) 250mm Thick 1950 EXT 300mm (1500 I.D Expanded) 200mm Thick 1950 EXT 600mm (1500 I.D Expanded) 200mm Thick 1950 EXT 900mm (1500 I.D Expanded) 200mm Thick 600 Class D Stormwater Manhole Upstand 150mm Thick Available Openings: 600mm Dia 1050mm Dia 600 x 600 600 x 900 800 x 900 900 x 900 Cast Iron Cover & Frames Or Grates Can Be Cast In Flush. An Extensive Range Of Sizes Are Available Upon Request Custom Sizes Are Made To Order

PRECAST LINTELS MODEL S - M - L MODEL VS ELEVATION DIMENSIONS Lintel A B C D X (Kg) VS 1200 830 650 720 230 250 S 2400 2040 1800 1970 400 500 M 3600 3240 3000 3170 690 700 L 4800 4440 4200 4370 1000 900 PLAN Lintel Description VS Very Small, S Small, M Medium Dimensions (mm) & s (kg) are Approx. Only Manufactured to ISO 9001

C-M Batter Chutes For Use on Embankments Width Internal 440mm External 550mm 50mm Height Internal 160mm External 215mm Height Internal 110mm External 160mm They can be safely handled and easily installed on site using a 1.3t Swiftlift foot anchor. Width Internal 330mm External 425mm

Sub-Soil Components 300 300 75 100mm Plastic Cap Clean Out Cap 110 Dia Outlet Hole 540 80 380 380 * Pest Proof Flap Available Outlet P: (07) 3804 6622 F: (07) 3804 6699

C-M Precast Sloping Headwall Concrete S40 MRD Class Exposure C Reinforcing 12Y/ RF72 Lifting Anchors 1.3 Tonne E B C A Side View D Rear View Nom. Pipe Size Dimensions (Approx. Only) A B C D E MASS KG 300 1220 415 650 650 270 400 375 1220 480 650 650 160 400 450 1500 570 880 800 350 500 525 1500 650 880 800 220 500 600 1500 720 880 800 210 500

Q-SEAL HEADWALL PIPE SIZE - 375-450 - 525 D Void to be filled post pipe installation. F E A B 12mm Reidbar Galv Ferrules for Curtin Wall Nom. Pipe Size Dimensions (Approx. Only) The Q-Seal eliminate dislodgement from headwall during high flow The Q-Seal achieves a sealing and adhesion to the stormwater pipe by pouring premix concrete into the void. TMR Approved in conjunction with standard Drawing 1243. KG A B C D E F G 375 500 1490 1010 790 720 110 410 TBA 450 580 1490 1010 790 720 110 410 TBA 525 660 1490 1010 790 720 110 410 TBA Available in all sizes 375-1050 Subsoil outlets on all headwalls with Q- Seal system. Design life of 100 years. Lifting Anchors - 3 x 1.3 Swiftlifts Subsoil Outlets C Patent Pending G

Q-SEAL HEADWALL PIPE SIZE - 600-675 - 750-825 D Void to be filled post pipe installation. F E A B 12mm Reidbar Galv Ferrules for Curtin Wall Nom. Pipe Size Dimensions (Approx. Only) KG A B C D E F G 600 752 2120 1460 1100 1330 130 960 1730 675 850 2120 1460 1100 1330 130 960 1550 750 930 2120 1460 1100 1330 130 960 1380 825 1020 2120 1460 1100 1330 130 960 1200 The Q-Seal eliminate dislodgement from headwall during high flow The Q-Seal achieves a sealing and adhesion to the stormwater pipe by pouring premix concrete into the void. TMR Approved in conjunction with standard Drawing 1243. Available in all sizes 375-1050 Subsoil Outlets Subsoil outlets on all headwalls with Q- Seal system. Design life of 100 years. Lifting Anchors - 4 x 2.5 Swiftlifts C Patent Pending G

Q-SEAL HEADWALL PIPE SIZE - 900-1050 D Void to be filled post pipe installation. F E A B 12mm Reidbar Galv Ferrules for Curtin Wall Nom. Pipe Size Dimensions (Approx. Only) KG A B C D E F G 900 1100 2670 1790 1400 1570 130 850 3360 1050 1240 2670 1790 1400 1570 130 850 3210 The Q-Seal eliminate dislodgement from headwall during high flow The Q-Seal achieves a sealing and adhesion to the stormwater pipe by pouring premix concrete into the void. TMR Approved in conjunction with standard Drawing 1243. Available in all sizes 375-1050 Subsoil Outlets Subsoil outlets on all headwalls with Q- Seal system. Design life of 100 years. Lifting Anchors - 4 x 2.5 Swiftlifts C Patent Pending G

SMALL BOX CULVERT 450 Series Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved 700 Available Lengths 2400 450 1200 100 Precast Headwalls are available to suit the range. Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Lifting 4 x 1.3 Swiftlift Anchors Range 1.2m Long 2.4m Long 450 x 225 450Kg 900Kg 450 x 300 485Kg 970Kg 450 x 375 520Kg 1040Kg

SMALL BOX CULVERT 600 Series Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved 850 Available Lengths 2400 1200 600 Precast Headwalls are available to suit the range. 100 Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Lifting 4 x 1.3 Swiftlift Anchors Range 1.2m Long 2.4m Long 600 x 225 430Kg 860Kg 600 x 300 480Kg 955Kg 600 x 375 590Kg 1175Kg 600 x 450 620Kg 1235Kg

SMALL BOX CULVERT 750 Series Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved 1000 Available Lengths 2400 1200 750 Precast Headwalls are available to suit the range. 100 Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Lifting 4 x 1.3 Swiftlift Anchors Range 1.2m Long 2.4m Long 750 x 225 590Kg 1180Kg 750 x 300 635Kg 1270Kg 750 x 375 695Kg 1390Kg 750 x 450 735Kg 1465Kg

SMALL BOX CULVERT 900 Series Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved 1150 Available Lengths 2400 1200 900 Precast Headwalls are available to suit the range. 100 Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Lifting 4 x 2.5T Swiftlift Anchors Range 1.2m Long 2.4m Long 900 x 225 670Kg 1340Kg 900 x 300 720Kg 1440Kg 900 x 375 760Kg 1520Kg 900 x 450 810Kg 1620Kg

SMALL BOX CULVERT 1200 Series (300 600) Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved Available Lengths 2400 1200 Integrated Headwall Available in 1200 Range - IHS 100 Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Lifting 4 x 2.5T Swiftlift Anchors Range 1.2m Long 2.4m Long 1200 x 300 840Kg 1680Kg 1200 x 375 960Kg 1915Kg 1200 x 450 1005Kg 2010Kg 1200 x 600 1095Kg 2190Kg

SMALL BOX CULVERT 1200 Series (750-1200) Australian Standards Reinforced Concrete Box Culverts AS1597.1-2010 - TMR Approved 1480 1200 150 Available Lengths 2400 1200 Precast Headwalls are available to suit the range. 100 Load Class Roadway 0-2m Fill Cover Exposure B2 For Placement Refer to Installation Guide Range 1.2m Long 2.4m Long 1200 x 750 1550Kg 3100Kg 1200 x 900 1655Kg 3310Kg 1200 x 1200 1865Kg 3730Kg Lifting 4 x 2.5T Swiftlift Anchors

RCBC Integrated Headwall 1200 Series Australian Standards AS1597.1-2010 2150 1480 600 1200 or 2400 350 125 Varies Multi-Cell Single Cell & Multi-Cell Application Exposure B2 Monolithic Construction Weep Holes over Crown

PRECAST INTERLOCKING KERB Interlocking Kerbs are used on roads for temporary lane diversions / construction sites. Optional fencing can be installed using the loc socket system for barrier mesh or steel mesh fencing. End Cone Rebated 15mm for Connector Plate 2 x 16mm S/S Thread Anchors 1 x 1.3T Swiftlift Anchor Connector Plate: 50x5 Gal Flat Bar w/- 2 x 20mm Holes 480 8TM 300 Mesh 40 200 1000 480

PRECAST 1650mm WHEELSTOP Manufactured to Aust. Std's AS/NZS2890.1:2004 1650 Location Holes 2 x 20 Dia at 260 from ctrs 2 x 1.3 Swift Lift Anchors 200 100 Bitumen surface mounting recommend 200 long x 16 Dia Galv Drive Pins x 2 Concrete surface mounting recommend 16mm sleeve anchor or 12mm Hex Head Screw Bolt Approx 81Kg

C-M Light Pole Base For Cross Falls 1:2 & 1:4 860 560 700 120 1100 Type 2 1260 325 470 Plan View Cross Fall Type 1:2 Type 2 650Kg 1:4 Type 4 540Kg 1100 Type 4 Maximum Pole Height: 10mtr Concrete: N40 TMR Drawing: 1393