Fiber displacement sensor

Similar documents
ZW Series Confocal Fiber Displacement Sensor

The Easy Way to Get Your 2D Profile

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

Confocal Fiber Displacement Sensor ZW Series

Most Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

Distance-setting Photoelectric Sensor

Confocal Fiber Displacement Sensor ZW Series

Distance-setting Photoelectric Sensor

Confocal fiber displacement sensor

Confocal Fiber Displacement Sensor

LED Displacement Sensor

High-precision Optical Switch

E3S-CR62/67. Ideal for detecting transparent glass and plastic containers. Transparent bottle sensor. Features

E3Z-LS. Distance-settable Photoelectric Sensor. Ordering Information. Sensors. Accessories (Order Separately)

Label Sensor. Ordering Information. Application Example E3S-CD68/CD63. Ideal for Detecting Labels on Bottles. E3S-CD68/CD63 Label Sensor

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Confocal Fiber Displacement Sensor ZW-7000/5000 Series

Z4D-F. LED-type Micro Displacement Sensor with Many Features in a Compact Body. Micro Displacement Sensor. Ordering Information.

2D Profile Measuring Sensors Ultra Wide Laser Beam & Super High-speed Measurement

Product Discontinuation Notices

Stable, Easy & Affordable

E2F. Cylindrical Proximity Sensor in Plastic Housing. Applications. Ordering Information. Sensors. Accessories (Order Separately)

E3S-CL. Distance setting photoelectric sensor in metal housing. Features

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Remote Sensor Amplifier Terminal

Connections Appearance Sensing method Sensing distance Operating mode Model Plug-in connector Horizontal Through-beam 30 m Light-ON

Remote Sensor Amplifier Terminal

Absolute Rotary Encoder

HPJSeries HPJ. Ultraminiature Photoelectric Sensors with Self-contained Amplifier

Built-in Amplifier Photoelectric Sensor

Supply voltage Output configuration Resolution (P/R) Model 12 to 24 VDC Complementary output 100, 200, 360, 500, or 600 E6F-CWZ5G 1,000

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Silicon Wafer Mapping Sensor F3M-S. Ordering Information. Application Examples. Allows Simultaneous Mapping of up to 25 Silicon Wafers

Confocal Fiber Displacement Sensor ZW-8000/7000 Series

E3NC-L/E3NC-S. Smart Laser Sensors. Best fit for challenging sensing applications. Laser Sensors for highest precision detection

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Solid-state Timer H3DS

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Operating mode. distance. 7 m Light ON Dark ON (selectable) 2 m [100 mm] (See note 1.) 100 mm (wide view)

Parallel Beam Linear Sensor

Inductive Proximity Sensor

E3X-NL. Employs OMRON's Unique Free Angle Optics Technology for Detecting Minute Differences in Glossiness. Optical Fiber Glossy Object Sensor

Built-in Amplifier Photoelectric Sensor

Output configuration. Dark-ON. Light-ON. Dark-ON. Light-ON. Dark-ON. Light-ON

Correction Reissue. Product Discontinuation Notices

Integrated servo motor

Compact Photoelectric Sensor

ZS CSM_ZS_DS_E_5_3. Sensors Controllers Peripheral Devices. Data Storage Units. Multi-Controllers

Reliable measurements for any material

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

High Speed, Multi-point Laser Displacement Sensor HL-D3 SERIES. panasonic.net/id/pidsx/global

10 to 30 VDC (10% max. permissable ripple peak-to-peak)

Laser Displacement Sensor Z4M. Ordering Information

40 mm Beam Pitch General Purpose Area Sensor NA40 SERIES

LED Collimated Beam Sensor LA-300 SERIES. LED collimated beam type which is as accurate as a laser sensor, but much safer.

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

ZX1 & ZX2 SERIES. Compact displacement sensing.»» All-in-one housing»» Highly stable any surface»» Plug & play simple operation

Product Discontinuation Notices

Safety Relay Unit. OFF-delay time

Long Range Metal Body Sensor

Sensing method Appearance Sensing distance Operation mode Model. Emitter E3S-2LE4 Through-beam *1. 2 m. 0.1 to 2 m. 300 mm. 2 m

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

NPN PNP NPN PNP NPN PNP

EE-SPY311/411/312/412

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Fuzzy Temperature Controllers E5AF

Type Sealing Poles Contacts Rated voltage Model 5PST-NO, SPST-NC 24 VDC *1

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

CZ-K Series. RGB Digital Fiberoptic Sensors. Description MAIN MENU PRODUCTS APPLICATIONS INDEX SELECTION GUIDE

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Digital Fiber-Optic Switches

Line beam for fast, accurate measuring of height and width

CD4 Series with linear image sensor and electronic shutter provides accurate measurement.

2 m ZX1-LD50A61 2M ZX1-LD50A81 2M Pre-wired. 50 ± 10 mm

FA Wireless SS Terminals

EE-SPY311/411/312/412

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Ordering Information. Application Example. New General-purpose Incremental. Rotary Encoder

onlinecomponents.com

Color Detection Fiber Sensor FZ-10 SERIES. Reliable and precise color discrimination. Red, green and blue LEDs. Easy set up

Non-Ferrous-Metal-Detecting Proximity Sensor (Separate Amplifier Type)

Photoelectric Sensor

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Inductive Proximity Sensor

Ultra-slim Body Picking Sensor NA1-PK5 SERIES NA1-5 SERIES. Even a slim hand is detectable by the 25 mm in pitch beam area sensor

Sensing method Appearance Sensing distance Operation mode Model Convergent-reflective (narrow vision field) 30 to 100 mm (variable)

Smart Sensor. Phone: Fax: Web:

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

High Speed Response Type With Built-in Output Protection Circuit

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

E3NC. Smart Laser Sensors. Ideal for Applications That Cannot Be Handled with Fiber Sensors or Photoelectric Sensors. Features

Transcription:

ZW-CE@, ZW-S@@ Fiber displacement sensor The benefits of OMRON s white light confocal principle Small size and ultra-lightweight fiber displacement sensor Stable measurements for any material with same mounting position Robust sensor head structure Synchronous measurement with EtherCAT System configuration Sysmac Studio Ethernet/USB connection NJ-Series Machine automation controller Confocal fiber displacement sensor Fiber displacement sensor

Specifications specifications ZW-S7 ZW-S ZW-S ZW-S Measuring center distance 7 mm mm mm mm Measuring range ±. mm ± mm ± mm ± mm Static resolution *. m. m. m. m Linearity * ±. m ±. m ±. m ±7. m Spot diameter * Near m dia. m dia. 7 m dia. 9 m dia. Center m dia. m dia. m dia. m dia. Far m dia. m dia. 7 m dia. 9 m dia. Measuring cycle s to ms Operating ambient illumination Illumination on object surface. lx or less: incandescent light Ambient temperature range Operating: to ºC, Storage: to ºC (with no icing or condensation) Ambient humidity range Operating and storage: % to % (with no condensation) Degree of protection IP (IEC9) Vibration resistance (destructive) to Hz,. mm single amplitude, min each in X, Y and Z directions Shock resistance (destructive) m/s times each in six directions (up/down, left/right, forward/backward) Temperature characteristic *. m/ºc. m/ºc. m/ºc. m/ºc Materials Case: aluminium die-cast/fiber cable sheat: PVC/Calibration ROM: PC Fiber cable length. m, m (flex-resistant cable) Fiber cable minimum bending radius mm Insulation resistance (calibration ROM) Between case and all terminals: M (by V megger) Dielectric strength (calibration ROM) Between case and all terminals: VAC, / Hz, min Weight Approx. g (chassis, fiber cable total) Accessories Instruction sheet, fixing screw (M) for calibration ROM, precautions for correct use * Capacity value when OMRON standard mirror surface target is measured at the measurement centre distance as the average of,9 times. * Material setting for the OMRON standard mirror surface target: error from an ideal straight line when measuring on mirror surface. The reference values for linearity when targets to measure other than the above are as in the below table: ZW-S7 ZW-S ZW-S ZW-S Grass ±. m ±. m ±. m ±7. m ±. m ±. m ±. m ±. m ±. m ±.7 m ±. m ±9. m * Capacity value defined by /e (.%) of the center optical intensity in the measured area. * Temperature characteristic at the measurement center distance when fastened with an aluminium jig between the sensor head and the target and the sensor head and the controller are set in the same temperature environment. specifications ZW-CE@ ZW-CE@ Input/output type NPN PNP Number of connected sensor heads per controller compatibility Available Light source for measurement White LED Segment Main display -segment red display, digits display Sub display -segment green display, digits LED display Status indicators HIGH (orange), PASS (green), LOW (orange), STABILITY (green), ZERO (green), ENABLE (green), THRESHOLD-H (orange), THRESHOLD-L (orange), RUN (green) EtherCAT indicators L/A IN (Link Activity IN) (green), L/A OUT (Link Activity OUT) (green), ECAT RUN (green), ECAT ERR (red) External Ethernet BASE-TX, BASE-T, no-protocol communications (TCP/UDP). EtherNet/IP TM interface EtherCAT EtherCAT specific protocol BASE-TX RS-C Up to. bps Analog output Analog voltage output (OUTV) to V, output impedance: terminal Analog current output block (OUTA) to ma, max. load resistance: -pole extension Judgment output (HIGH/PASS/LOW) connector BUSY output (BUSY) ALARM output (ALARM) ENABLE output (ENABLE) LED OFF input (LED OFF) DC input system ZERO RESET input (ZERO) TIMING output (TIMING) RESET output (RESET) Bank Selected bank output (BANK_OUT to ) Selected bank input (BANK_SEL to ) Transistor output system Output voltage:. to VDC Load current: ma max. Residual voltage when turning ON:. V max. Leakage voltage when turning OFF:. ma max. Input voltage: VDC ±% (. to. VDC) Input current: 7 ma Typ. ( VDC) Voltage/current when turning ON: 9 V/ ma min. Voltage/current when turning OFF: V/ ma max. Transistor output system Output voltage:. to VDC Load current: ma max. Residual voltage when turning ON:. V max. Leakage voltage when turning OFF:. ma max. DC input system Input voltage:. to VDC Input current: 7 ma Typ. ( VDC) Voltage/current when turning ON: 9 V/ ma min. Voltage/current when turning OFF: V/ ma max. Sensing

ZW-CE@ ZW-CE@ Main functions Exposure time Auto/Manual Measurement cycle s to ms Material setting Standard//Diffusion surfaces Measurement item Height/Thickness/Calculation Filtering Median/Average/Differentiation/High-pass/Low-pass/Band-pass Outputs Scaling/Different holds/zero reset/logging for a measured value Display Measured value/threshold value/analog output voltage or current value/judgment result/resolution/ Exposure time Number of configurable banks Up to banks Task process Multi-task (up to tasks per bank) System Save/Initialization/Display measurement information/communication settings/ calibration/ Key-lock/Trigger key input Ratings Power supply voltage. to. VDC (including ripple) Current consumption ma max. Insulation resistance Across all lead wires and controller case: M ( VDC megger) Dielectric strength Across all lead wires and controller case: VAC, / Hz, min Environmental Degree of protection IP (IEC9) Vibration resistance (destructive) to Hz,. mm single amplitude, min each in X, Y and Z directions Shock resistance (destructive) m/s, times each in six directions (up/down, left/right, forward/backward) Ambient temperature Operating: to ºC Storage: to ºC (with no icing or condensation) Ambient humidity Operating and storage: % to % (with no condensation) Grounding D-type grounding (Grounding resistance of max.) Note: For conventional Class D grounding Materials Case: PC Weight Approx. 7 g (main unit only), approx. g (parallel cable) Accessories Instruction sheet, member registration sheet, parallel cable (ZW-XCPE) Note: s with binary outputs are also available (ZW-CET/CET). Please contact your OMRON sales representative for details. Sysmac Studio software specifications Conditions Operating system (OS) ** Windows XP (Service Pack or more, -bit version), Vista (-bit version), 7 ( or -bit version) CPU Windows PC with a Celeron (. GHz) or faster CPU Equivalent or higher recommended Core i M (. GHz) Memory GB or more Using the D motion trace Video memory: MB min. One of the following video card: NVIDIAR GeForceR series or ATI RaedonHD series Free hard disk space. GB or more Display XGA 7 million colors WXGA or higher recommended Disk device DVD-ROM drive Communication port USB port supports USB. or Ethernet port * Supported languages Japanese, English, German, French, Italian, Spanish, simplified Chinese, traditional Chinese, Korean * Sysmac Studio operating system precaution: System requirements and hard disk space may vary with the system environment. * The following restrictions apply when Sysmac Studio is used with Microsoft Windows Vista / 7: - Some help files cannot be accessed. - The help files can be accessed if the help program distributed by Microsoft for Windows (WinHlp.exe) is installed. Refer to the Microsoft homepage listed below or contact Microsoft for details on installing the file. (The download page is automatically displayed if the help files are opened while the user is connected to the Internet.) - http://support.microsoft.com/kb/977/en-us * Refer to the hardware manual for your controller for hardware connection methods and cables to connect the computer and controller. EtherCAT communication specifications Specifications Communication standards IEC Type Physical layer BASE-TX (IEEE.) Connector RJ, EtherCAT IN: EtherCAT input, EtherCAT OUT: EtherCAT output Communication system Category or higher (cable with double, aluminium type and braided shielding) is recommended Max. communication distance value Distance between nodes: within m Process data Variable PDO mapping Mailbox (CoE) Emergency messages, SDO requests, SDO responses, SDO information Distributed clock Synchronization in DC mode LED display L/A IN (Link Activity IN), L/A OUT (Link Activity OUT), AECAT RUN, AECAT ERR Fiber displacement sensor

Dimensions ZW-S7/S/S/S Standard surface Four, M ±. Standard surface Four,. dia. (Mounting holes) ±. ±. ±. Standard surface Mounting hole dimensions Measurement center M (see note) M (see note) Standard fiber cable (. dia.) Connector Note: Model L M X ZW-S7 7. ZW-S. ZW-S.7 ZW-S.7 X (see note) Measurement end FAR Measurement CENTER Measurement end NEAR L (see note) Lighting and receiving axis () Caution label () () ( dia.) ZW-CE@/CE@.9. (.) 7 (.) 7. DIN track attachment hook Four,. dia. 7 7±. ±.. Installation holes Four, depth. MAX. Mounting hole dimensions Extension fiber cable ZW-XFR/XFR/XFR/XFR/XFR FC connector Fiber cable (. dia) FC connector * The following table lists cable lengths per models. Model Cable length L ( dia.) ZW-XFR ZW-XFR m m ± ± () L* () () ZW-XFR ZW-XFR ZW-XFR m m m ± ± ± Sensing

Characteristic data Linearity characteristic by materials + Measurement center distance ZW-S7 Material setting: Normal Material setting: surface Material setting: Diffusion surface.................. ZW-S Material setting: Normal Material setting: surface Material setting: Diffusion surface........................ ZW-S Material setting: Normal Material setting: surface Material setting: Diffusion surface........................ ZW-S Material setting: Normal Material setting: surface Material setting: Diffusion surface Fiber displacement sensor

Angle characteristic* direction direction Model nameplate + + ZW-S7 direction direction +.... +.... direction direction + +........ ZW-S direction direction direction direction + + + +........ ZW-S direction direction direction direction + + + + ZW-S direction direction direction direction + + + + * The above show the results after executing scaling. Sensing

Ordering information Ethernet/USB connection Sysmac Studio NJ-Series Machine automation controller Confocal fiber displacement sensor B C Extension fiber cable A Symbol Measuring range Spot diameter Static resolution Model A 7 ±. mm m dia.. m * /. m ZW-S7 ± mm m dia.. m * /. m ZW-S ± mm m dia.. m * /. m ZW-S ± mm m dia.. m * /. m ZW-S * The high resolution types are subject to the export control restrictions. Note: When ordering, specify the cable length (. m,. m). Symbol Power supply voltage Output type Model Appearance B VDC NPN ZW-CE * * The high resolution types are subject to the export control restrictions. Note: with binary outputs are also available (ZW-CET/CET). Cables ZW-CET PNP ZW-CE * ZW-CET Symbol Cable length Model Appearance C to m ZW-XFR Extension fiber cable (flexible cable) m ZW-XFR (fiber adapter ZW-XFC provided) m ZW-XFR m ZW-XFR m ZW-XFR Fiber adapter (between sensor head pre-wired cable and extension fiber cable) ZW-XFC Parallel cable for ZW-CE@T -pole * (included with controller ZW-CE@T) m ZW-XCPE RS-C cable for personal computer m ZW-XRS RS-C cable for PLC/programmable terminal m ZW-XPT * A parallel cable for controllers with binary outputs is also available (ZW-XCPE). Please contact your OMRON sales representative for details. Fiber displacement sensor 7

Accessories Fiber connector cleaner Note: Place orders in units of boxes (contacting units). Setting software Smart monitor ZW Computer software Sysmac Studio version. or higher Model ZW-XCL Model ZW-SW Model SYSMAC-SE@@@ ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.97. To convert grams into ounces, multiply by.7. Cat.No. SysCat_E-E- In the interest of product improvement, specifications are subject to change without notice. Sensing