Synchrometrology and PMU Testing at NIST

Similar documents
Test Suite Specification

Lessons learned from the NIST assessment of PMUs

Traceable Synchrophasors

New Standards for Test and Calibration of Phasor Measurement Units

Phasor Measurement Unit (PMU) Performance Test Report for TESLA 4000

6135A/PMUCAL Phasor Measurement Unit Calibration System

PMU Implementation Issues

CONVERT ERLPhase TESLA DMEs TO PHASOR MEASUREMENT UNITS (PMUs)

Jean-Pierre Braun obtained the B.E. degree from the Ecole d'ingénieurs de Genève, Switzerland, in 1980; the M.E.M. degree from the University of

Phasor Measurement Unit and Phasor Data Concentrator test with Real Time Digital Simulator

Testing and Calibration of Phasor Measurement Units

Phasor Measurement: A Short History of the Technology and the Standards. Harold Kirkham Pacific Northwest National Laboratory

New Standards for Test and Calibration of Phasor Measurement Units

Evaluation of Steady-State and Dynamic Performance of a Synchronized Phasor Measurement Unit

The Virginia Tech Calibration System

New Standards for Test and Calibration of Phasor Measurement Units

Characterizing dynamic behavior of PMUs using step signals z

Automated Testing Of PMU Compliance

Measurement tools at heart of Smart Grid need calibration to ensure reliability

PMU (algorithm) Testing to C (a) in software. Dr. Andrew Roscoe

Critical analysis of PMU testing procedures for step response evaluation

A P + M Phasor Measurement Unit

Algorithms for the synchrophasor measurement in steady-state and dynamic conditions

PMU (algorithm) Testing to C (a) in software

Fault Location using PMU Measurements and Wide-area Infrastructure

Experiences with Steady-State PMU Compliance Testing using Standard Relay Testing Equipment. In:

Steady State Testing and Analysis of a Phasor Measurement Unit

THE ROLE OF SYNCHROPHASORS IN THE INTEGRATION OF DISTRIBUTED ENERGY RESOURCES

Phasor Measurement Unit Testing

THE CHALLENGES OF TESTING PHASOR MEASUREMENT UNIT (PMU) WITH A DISTURBANCE FAULT RECORDER (DFR) Krish Narendra, Zhiying Zhang, John Lane

Implementation of Smart DFT-based PMU Model in the Real-Time Digital Simulator

Testing and Validation of Synchrophasor Devices and Applications

Comparative Testing of Synchronized Phasor Measurement Units

Verifying Interoperability and Application Performance of PMUs and PMU-Enabled IEDs at the Device and System Level

Dynamic PMU Compliance Test under C aTM-2014

Steady-State PMU Compliance Test under C a-2014

Enabling Tomorrow s Technology Today

Adaptive-window PMU algorithms using cascaded boxcar filters to meet and exceed C (a) requirements. Dr. Andrew Roscoe

NMI's Role and Expertise in Synchronization Applications

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Synchrophasors for Distribution Applications

SYNCHROPHASOR TECHNOLOGY GLOSSARY Revision Date: April 24, 2011

Power Quality Measurements the Importance of Traceable Calibration

Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DOBLE F6150SV TECHNICAL SPECIFICATIONS

F6052 Universal Time Synchronizer

Peter Dack, Vice President Sales & Marketing Radian Research, Inc.

Synchrophasors: Definition, Measurement, and Application

Wide Area Monitoring with Phasor Measurement Data

PRC Compliance Using Bitronics 70 Series Recorders

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

CAPRICA: A Testbed Demonstrating a Cyber-Secure Synchronous Power Island. Dr Kieran McLaughlin, Dr David Laverty, Prof Sakir Sezer

State Estimation Advancements Enabled by Synchrophasor Technology

RT- HIL Implementation of Hybrid Synchrophasor and GOOSE- based Passive Islanding Schemes

THE core component of a phasor measurement unit (PMU)

19th Meeting of the Directors of NMIs and Member State Representatives with BIPM

DESIGN AND SIMULATION OF WIDE AREA MONITORING WITH SMART GRIDS USING PHASOR MEASUREMENT UNIT WITH DISTRIBUTED GENERATION

Meeting PMU Data Quality Requirements for Mission Critical Applications Anurag K. Srivastava Washington State University

Task Force on Synchrophasor Protection Applications NASPI Engineering Analysis Task Team Matthew Rhodes 3/22/16

Wind Power Facility Technical Requirements CHANGE HISTORY

Specification for a Fully Automatic Meter Test Equipment for testing Three-phase/Single/Transformer operated/ reference Standard energy meters.

Embedded Generation Information Package

TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY

PQube 3 Specifications

Under-Frequency Load Shedding based on PMU Estimates of Frequency and ROCOF

CMC 256plus - protection relay test set and universal calibrator

Enhanced DFT Algorithm for Estimation of Phasor by PMU under Power Quality Events

Issue No : 2 Dt of Revision :

Performance Evaluation of Phasor Measurement Systems

DOBLE F6150e TECHNICAL SPECIFICATIONS

ENG52: SmartGrids2 Measurement Tools For Grid Stability and Quality Management. M18 Workshop, 3rd February Paul Wright, Project Coordinator.

Bi-lateral comparison of pistonphone calibration between INMETRO and INTI

Experiences of Using Synchrophasors at Duke Energy

Certificate of Calibration

Moving Test - MT3000

Model 1133A Power Sentinel. with. Digital Signal Analysis SYNCHRONIZED POWER QUALITY/REVENUE STANDARDS

Voltage Sag Immunity Compliance Certificate PULS QS10.241, QS A1, QS C1

/ Maximum flexibility for the applications of tomorrow. / Open data communication. / Smart Grid Ready

C300 3-Phase Power Calibrator and Tester. 3 x 0 560V, 3 x 0 120A, Hz. Accuracy: 0.02% or 0.05%

Events Captured and Findings To Date. John Ballance and Abhijeet Agarwal EPG John Adams and Jian Chen ERCOT

Smart Transmission Grids Operation and Control

The dynamic behavior of PMU and the latest development in China

Business Opportunity. The wave is coming. The Opportunity. Time Synchronization as a first-order concept You take care of it, or you will pay for it!

Algorithms to Improve Performance of Wide Area Measurement Systems of Electric Power Systems

SMB/5835/SBP. TC13 Scope

CT Analyzer. Revolution in current transformer testing and calibration

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Challenges in Evaluating Smart Grid Solutions: Metric, Testing, Certification, Modeling and Simulation, Testbeds

PERFECT TIMING CRAIG PREUSS, P.E. HOW IEEE STANDARD PC IMPACTS SUBSTATION AUTOMATION

Synchrophasors and the Smarter Grid

Reliability Guideline

Interconnection-Wide Oscillation Analysis: Baselining Oscillation Modes in the North American Power System Objective Purpose

IEEE sion/1547revision_index.html

PROGRAMMABLE AC POWER SOURCE

High Stability Voltage Source

TECHNICAL DATA FRONIUS SYMO ( M, M, M, M, M)

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

Accurate Synchrophasor Estimation to Support the Islanding Maneuver of Active Distribution Networks

Transcription:

Synchrometrology and PMU Testing at NIST Jerry FitzPatrick and Tom Nelson National Institute of Standards and Technology i-pcgrid Workshop 2013 March 27, 2013

2 Topics for Today NIST Mission SGIP NIST Synchrometrology Testbed PMU Testing

Physical Measurement Laboratory Mission Promote U.S. innovation and industrial competitiveness by advancing the frontiers of measurement science and by realizing, disseminating, and internationally coordinating the physical standards of measurement We carry out this mission by: Providing measurement, calibration, and data services Developing new standards and measurement methods Conducting an aggressive dissemination program Pursuing long-term fundamental research that anticipates future needs Partnering with universities, industry, and government agencies 3 3

4 PML is Responsible for the International System of Units (SI) How it is Scientifically based Defined by consensus Realized in practice Disseminated for routine uses Disseminated for new and novel uses Maintained and Improved SI underpins all measurements, whether expressed in metric units, traditional British units, or other units 4

The NIST Role Energy Independence and Security Act (EISA) of 2007 Title XIII, Section 1305. Smart Grid Interoperability Framework In cooperation with the DoE, NEMA, IEEE, GWAC, and other stakeholders, NIST has primary responsibility to coordinate development of a framework that includes protocols and model standards for information management to achieve interoperability of smart grid devices and systems 5

Smart Grid Interoperability Standards Coordination NIST Smart Grid Framework document Release 2 (Feb 2012) and Release 1 (Jan 2010) Smart Grid vision & architectural reference model Identifies 100+ key standards; cybersecurity guidelines, testing and certification framework Provided a foundation for IEC, IEEE, ITU, and other national and regional standardization efforts 6 NIST Smart Grid Interoperability Panel (SGIP) Over 800 organizations, 1900 participants, many international members Governing Board and committees, priority action plans Coordination of standards development by SDOs New SGIP 2.0, Inc. legal entity established

7 NIST SynchroMetrology Laboratory Tom Nelson Jerry Stenbakken Allen Goldstein Yi-hua Tang

8 Overall Purpose and Objective NIST SynchroMetrology Laboratory established to provide state-of-the-art standards and performance testing facility for time synchronized power grid instrumentation focus on PMUs Created in 2006 DoC/DoE funding Static Calibration System 2008 Dynamic Calibration System 2009

NIST SynchroMetrology Laboratory We are the only NMI to offer calibrations for PMUs Combine NIST Capabilities in Time Metrology and in Waveform Metrology Developed Laboratory to Perform Calibrations of Phasor Measurement Units (PMUs) Provide Assistance to Manufacturers and Utilities on Design and Use of PMUs Developing capability to calibrate PMU calibrators

10 Improved PMU Performance Before After Interharmonic Test Total Vector Error % - Voltage channels VA TVE % VB TVE % VC TVE % V1 TVE % 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 2.5 5 0 0 25 50 75 100 125 150 Interharmonic Frequency Hz Figure IH1A. Total Vector Error (TVE) for the voltage channels VA (top), VB, VC, and V1 (bottom) versus interharmonic frequency (10 % of fundamental magnitude). IH12_4_16_09cut Mean Min Max Std Dev VA TVE % VB TVE % VC TVE % V1 TVE % 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 2.5 5 0 15 12.5 10 7.5 Interharmonic Test Total Vector Error % - Voltage channels 2.5 5 0 0 25 50 75 100 125 150 Interharmonic Frequency Hz Mean Min Max Std Dev Figure IH1A. Total Vector Error (TVE) for the voltage channels VA (top), VB, VC, and V1 (bottom) versus interharmonic frequency (10 % of fundamental magnitude). IH12_6_22_09cut

11 Standards used by PMUs IEEE Std. C37.118.1-2011 Synchrophasor measurement IEEE Std. C37.118.2-2011 Synchrophasor communications IEEE Std. 754-1985 Standard for Binary Floating Point Arithmetic IEC 61850-90-5 Use of IEC 61850 to transmit synchrophasor information according to IEEE C37.118 Various communications standards (Ethernet, TCP, UDP, etc.) Various timing standards (GPS, IRIG Std. 200-04, Universal Time Coordinated (UTC), IEEE Std. 1588, etc.) (future) IEEE PC37.240 Standard for cyber Security Requirements for Substation Automation, Protection and Control Systems.

12 Conformance is necessary: PMUs must be interoperable in a very large system! 21 or more PMU manufacturers More than 50 different models of PMU PMU functions included in multifunction devices : protective relays digital fault recorders power quality meters PMUs will be used in almost every power transmission system worldwide. Each PMU has 18 or more configurations of nominal frequency (F0), reporting rate (Fs), and class (M or P)

13 Measuring PMU electrical conformance IEEE Std. C37.118.1-2011 Section 5: Synchrophasor measurement requirements and compliance verification 5.5.5 Steady state compliance: Signal frequency range tests (up to 100 tests per configuration) Signal magnitude tests (up to 20 tests/configuration) Harmonic distortion tests (50 tests /configuration) Out of band interfering signals (50 to 100 tests/configuration) 5.5.6 Dynamic measurement bandwidth (modulation tests) (up to 100 tests/configuration) 5.5.7 Dynamic ramp tests (2 tests/configuration) 5.5.8 Dynamic step tests (40 tests/configuration*) 5.5.9 Measurement reporting latency (1 test) * 4 tests of 10 iterations each

TVE (%) 1.5 1.0 0.5 frequency error (Hz) Jerry Stenbakken and the first NIST PMU steady state calibration system voltage TVE 0.0 55.0 57.0 59.0 61.0 63.0 Input Frequency (Hz) 65.0 ROCOF Error (Hz/s) 14 frequency error 0.006 0.004 0.002 0.000-0.002-0.004-0.006 55.0 60.0 65.0 input frequency (Hz) 0.2 0 ROCOF error -0.2 55.0 60.0 65.0 Input Frequency (Hz) TVE_Limit MaxTVE_VC MaxTVE_VB MaxTVE_VA MaxTVE_V+ Min_FE Max_FE FE_Limit (pos) FE_Limit (neg) RFE_Limit (pos) RFE_Limit (neg) Far left: Jerry Stenbakken, middle: NIST s first PMU dynamic test system, far right: commercially available, fully automated PMU calibration system.

15 Requirements for a PMU calibration system Signal source magnitude and absolute phase shall be traceable to first principles as represented by national standards absolute phase is phase relative to time. True (reference) value uncertainty shall be verified. True values are the values of the signal source which are compared to the PMU Under Test s output to determine TVE, Fe, and RFe. Result calculations shall be verified to be compliant with IEEE C37.118.1:2011. Result calculations include TVE, Fe, RFe, Step Response Time, Step Delay Time, and Step Overshoot.

16 Future Changes Expected for NIST Test Systems PMUs with IEEE 1588 Synchronization Capability New NIST Developed Amplifiers to the Dynamic test system for Increased Stability and Reduced Noise

17 2013 Plans and Expectations Implement New C37.118.1-2011 Tests 61850-90-5 Message Transmission Develop Tests for PMU Calibrators Calibrate PMU Calibrators Conduct a PMU test lab round robin Make recommendations to PSRC WG H11 on frequency error and ROCOF limits

18 Thank you!