Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Similar documents
Module 1B RF Test & Measurement

UNIT-3. Electronic Measurements & Instrumentation

Understanding RF and Microwave Analysis Basics

Definitions. Spectrum Analyzer

8 Hints for Better Spectrum Analysis. Application Note

An Introduction to Spectrum Analyzer. An Introduction to Spectrum Analyzer

8 Hints for Better Spectrum Analysis. Application Note

Spectrum Analysis - Elektronikpraktikum

Swept-tuned spectrum analyzer. Gianfranco Miele, Ph.D

Hints. for making. Better. Spectrum Analyzer. Measurements. Application Note

Utilizzo del Time Domain per misure EMI

Interference Analysis and Spectrum Monitor Seminar

MAKING TRANSIENT ANTENNA MEASUREMENTS

OBJECTIVES EQUIPMENT LIST

A year and a half after the first introduction of the PXA, Agilent is now introducing the world s highest performance mmw signal analyzer in April

Agilent Spectrum Analysis Basics. Application Note 150

Lecture 6. Angle Modulation and Demodulation

Signal Detection with EM1 Receivers

A Guide to Calibrating Your Spectrum Analyzer

Radio Receiver Architectures and Analysis

100 Hz to 22. HP 8566B Spectrum Analyzer. Discontinued Product Support Information Only. Outstanding Precision and Capability

Keysight Technologies Spectrum Analysis Basics. Application Note 150

Lab Assignment #3 Analog Modulation (An Introduction to RF Signal, Noise and Distortion Measurements in the Frequency Domain)

ECE 440L. Experiment 1: Signals and Noise (1 week)

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Guide to Spectrum Analysis

HF Receivers, Part 2

Measuring Non-linear Amplifiers

4. Digital Measurement of Electrical Quantities

Technical Notes from Laplace Instruments Ltd. EMC Emissions measurement. Pre selectors... what, why and when?

PULSE CODE MODULATION TELEMETRY Properties of Various Binary Modulation Types

Spectrum. The basic idea of measurement. Instrumentation for spectral measurements Ján Šaliga 2017

RF Fundamentals Part 2 Spectral Analysis

Essential Capabilities of EMI Receivers. Application Note

Advances in RF and Microwave Measurement Technology

note application Measurement of Frequency Stability and Phase Noise by David Owen

Technician License Course Chapter 3 Types of Radios and Radio Circuits. Module 7

Superheterodyne Spectrum Analyzer and Spectrum Analysis. Shimshon Levy&Harel Mualem

Chapter 3. Amplitude Modulation Fundamentals

Measuring ACPR of W-CDMA signals with a spectrum analyzer

Outline. Communications Engineering 1

Spectrum Analyzer. EMI Receiver

SHRI ANGALAMMAN COLLEGE OF ENGINEERING & TECHNOLOGY (An ISO 9001:2008 Certified Institution) SIRUGANOOR,TRICHY

Keysight Technologies PNA-X Series Microwave Network Analyzers

GET10B Radar Measurement Basics- Spectrum Analysis of Pulsed Signals. Copyright 2001 Agilent Technologies, Inc.

Problems from the 3 rd edition

SmartSpice RF Harmonic Balance Based and Shooting Method Based RF Simulation

The Value of Pre-Selection in EMC Testing. Scott Niemiec Application Engineer

EMI Test Receivers: Past, Present and Future

SmartSpice RF Harmonic Balance Based RF Simulator. Advanced RF Circuit Simulation

Advances in RF and Microwave Measurement Technology

Twelve voice signals, each band-limited to 3 khz, are frequency -multiplexed using 1 khz guard bands between channels and between the main carrier

Efficiently simulating a direct-conversion I-Q modulator

Simulating and Testing of Signal Processing Methods for Frequency Stepped Chirp Radar

EE470 Electronic Communication Theory Exam II

6.101 Project Proposal April 9, 2014 Kayla Esquivel and Jason Yang. General Outline

TETRA Tx Test Solution

Rigol DSA705 Spectrum Analyzer Reviewed by Phil Salas AD5X

THE SPECTRUM ANALYZER AND SPECTRAL CONTENT

Definizione. Tipi di analizzatori

Sampling and Reconstruction

Exercise 1: Amplitude Modulation

Radio Receivers. Al Penney VO1NO

Introduction to Receivers

YEDITEPE UNIVERSITY ENGINEERING FACULTY COMMUNICATION SYSTEMS LABORATORY EE 354 COMMUNICATION SYSTEMS

8.5 Modulation of Signals

Digital Receiver Experiment or Reality. Harry Schultz AOC Aardvark Roost Conference Pretoria 13 November 2008

Direct-Conversion I-Q Modulator Simulation by Andy Howard, Applications Engineer Agilent EEsof EDA

Keysight Technologies Spectrum Analysis Basics. Application Note 150

Agilent AN 1275 Automatic Frequency Settling Time Measurement Speeds Time-to-Market for RF Designs

< 15% (< 30% for 3-MHz bandwidth)

Speech, music, images, and video are examples of analog signals. Each of these signals is characterized by its bandwidth, dynamic range, and the

DStar Co-channel and Adjacent Channel Performance

RF/IF Terminology and Specs

Introduction...1. The Electromagnetic Spectrum...9. Frequency Measurement Instrumentation Common Component Tests...39

Millimeter Wave Spectrum Analyzer with Built-in >100 GHz Preselector

Signals & Systems for Speech & Hearing. Week 6. Practical spectral analysis. Bandpass filters & filterbanks. Try this out on an old friend

R&S FSWP Phase Noise Analyzer Specifications

LABORATORY MANUAL COMMUNICATIONS LABORATORY EE 321

Fourier Analysis. Chapter Introduction Distortion Harmonic Distortion

PXA Configuration. Frequency range

LAB Assignment No. 6: TO STUDY GENERATION OF DOUBLE SIDE BAND AMPLITUDE MODULATE (AM) WAVEFORMS, USING DSB/SSB TRANSMITTER

Session 3. CMOS RF IC Design Principles

Introduction to Amplitude Modulation

Measurements 2: Network Analysis

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note

Amplitude Modulated Systems

Spectrum Analyzers R3132/3132N/3162 R3132/3132N/3162. Low cost, high performance. General-Purpose Spectrum Analyzer Adaptable to Various Applications

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Spectrum Analysis

HEWLETT PACKARD. Spectrum Analysis. Application Note 150. Spectrum Analysis Basics

EE 460L University of Nevada, Las Vegas ECE Department

From Digital to RF Debugging in the Time and Frequency Domain. Embedded Systems Conference 2015 May 6-7, 2015

COMPUTER ASSISTED RF PERFORMANCE TESTING. Warner Amex Cable Communications Inc Plainfield, NJ

ELT Receiver Architectures and Signal Processing Exam Requirements and Model Questions 2018

Agilent Vector Signal Analysis Basics. Application Note

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

Signal Processing for Digitizers

GAO-SAU-105 Spectrum Analyzer with Wide Frequency Range

ECE513 RF Design for Wireless

EET 223 RF COMMUNICATIONS LABORATORY EXPERIMENTS

Transcription:

SPECTRUM ANALYZER

Introduction A spectrum analyzer measures the amplitude of an input signal versus frequency within the full frequency range of the instrument The spectrum analyzer is to the frequency domain where as the oscilloscope is to the time domain In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed Spectrum analyzer greatly reduces the amount of noise present in the measurement and also ensure there s no interference from neighbouring frequencies.

SPECTRUM ANALYZERS The problems associated with non-real-time analysis in the frequency domain can be eliminated by using a spectrum analyzer. A spectrum analyzer is a real-time analyzer, which means that it simultaneously displays the amplitude of all the signals in the frequency range of the analyzer. Spectrum analyzers, like wave analyzers, provide information about the voltage or energy of a signal as a function of frequency. Unlike wave analyzers. spectrum analyzers provide a graphical display on a CRT. A block diagram of an audio spectrum analyzer.

SPECTRUM ANALYZERS The real-time, or multichannel. analyzer is basically a set of stagger-tuned bandpass filters connected through an electronic scan switch to a CRT. The composite amplitude of the signal within each filters bandwidth is displayed as a function of the overall frequency range of the filter. Therefore, the frequency range of the instrument is limited by the number of filters and their bandwidth. The electronic switch sequentially connects the filter outputs to the CRT.

SPECTRUM ANALYZERS Horizontal deflection is obtained from the scan generator, which has a saw tooth output that is synchronized with the electronic switch. Fig. 7 Block diagram of an audio spectrum analyzer.

SPECTRUM ANALYZERS Such analyzers are usually restricted to audiofrequency applications and may employ as many as 32 filters. The bandwidth of each filter is generally made very narrow for good resolution. The relationship between a time-domain presentation on the CRT of an oscilloscope and a frequency-domain presentation on the CRT of a spectrum analyzer is shown in the threedimensional drawing in Fig8.

SPECTRUM ANALYZERS Spectrum analyzers are used to obtain a wide variety of information from various kinds of signals, including the following. Spectral purity of continuous-wave (CW) signals. Percentage of modulation of amplitudemodulated (AM) signals. Deviation of frequency-modulated (FM) signals. Noise such as impulse and random noise. Filter frequency response.

DISTORTION OF AN AMPLIFIER Fig. 11 Test setup to measure the total harmonic distortion of an amplifies.

DISTORTION OF AN AMPLIFIER waveform is applied to the amplifier. The output of the amplifier is applied directly to the distortion analyzer which measures the total harmonic distortion. In the field of microwave communications, in which pulsed oscillators are widely used. spectrum analyzers are an important tool. They also find wide application in analyzing the performance of AM and FM transmitters. Spectrum analyzers and Fourier analyzers are widely used in applications requiring very low frequencies in the fields of biomedical electronics, geological surveying. and oceanography. They are also used in analyzing air and water pollution.

SPECTRUM ANALYZER TO MEASURE INTERMODULATION DISTORTION The spectrum analyzer can be used to measure the intermodulation distortion, as shown in the circuit in Fig14. The frequency of the audio oscillator is generally set to 6 khz. Fig.14 Using the spectrum analyzer to measure intermodulation distortion.

SPECTRUM ANALYZER TO MEASURE INTERMODULATION DISTORTION If the nonlinearity of the circuit is significant. the modulation of the higher-frequency signal by the lowerfrequency signal will produce the familiar amplitude modulation waveform as shown in Fig13. The percentage of intermodulation distortion is computed as M IMD m x100% where M m IMD = the intermodulation distortion expressed as a percentage M = the peak-to-peak modulated signal m = the minimum value of the modulated waveform

WAVEFORM PRODUCED BY INTERMODULATION DISTORTION Fig. 13 Amplitude-modulated waveform produced by intermodulation distortion.

Types The most common spectrum analyzer measurements are: modulation, distortion, and noise Spectrum analyzer types are: Swept tuned spectrum analyzer : It sweeps across the frequency range, displaying all the frequency components present. This enables measurements to be made over a large dynamic range and wide frequency range. FFT based spectrum analyzer : The FFT analyzer takes a timedomain signal, digitizes it using digital sampling, and then applies the mathematics required to convert it to the frequency domain. The result is displayed as a spectrum.

Swept tuned spectrum analyzer The major components in a spectrum analyzer are the RF input attenuator, mixer, IF (Intermediate Frequency) gain, IF filter, detector, video filter, local oscillator, sweep generator, and LCD display.

Input attenuator and mixer Its purpose is to adjust the level of the signal entering the mixer to its optimum level. If the signal level is too high, the readings fall outside the display, but also the mixer performance may not be optimum. A mixer is a three-port device that converts a signal from one frequency to another (sometimes called a frequency translation device)

Gain, filter and detector IF stages provide the required level of gain. It has to be used in conjunction with the RF gain control. Too high a level of IF gain will increase the front end noise level which may result in low level signals being masked. The IF filter is a band pass filter which is used as the "window" for detecting signals. It's bandwidth is also called the resolution bandwidth (RBW) of the analyzer and can be changed via the front panel of the analyzer. The analyzer must covert the IF signal to a baseband or video signal so it can be digitized and then viewed on the analyzer display. This is accomplished with an envelope detector whose video output is then digitized with an analog-to digital converter (ADC).

Video filter, LO, SG and ADC The video filter is a low-pass filter that is located after the envelope detector and before the ADC. This filter determines the bandwidth of the video amplifier, and is used to average or smooth the trace seen on the screen. The local oscillator (LO) must be capable of being tuned over a very wide range of frequencies to enable the analyzer to scan over the required range. The sweep generator actually tunes the LO so that its frequency changes in proportion to the ramp voltage. The video signal by the ADC is also synchronized with the sweep generator to create the frequency domain on the x-axis.

The three primary hard keys on any spectrum analyzer are: frequency, amplitude, and span Other important control functions include setting the resolution- bandwidth, sweep time, input attenuator and video bandwidth Most analyzers allow you to enter values by either punching in the value on the number pad, or by "dialing" up or down to the desired value using the front panel knob Front Panel

Advantages and disadvantages Advantages : Able to operate over wide frequency range Wide bandwidth Not as expensive as other spectrum analyzer technologies Disadvantages: Cannot measure phase Cannot measure transient events

Summary Spectrum analyzer measures the signal amplitude v/s frequency. The most common spectrum analyzer measurements are: modulation, distortion, and noise Two types of Spectrum analyzer are Swept tuned spectrum analyzer and FFT based spectrum analyzer The major components in a spectrum analyzer are the RF input attenuator, mixer, IF (Intermediate Frequency) gain, IF filter, detector, video filter, local oscillator, sweep generator, and LCD display. Can operate over wide frequency range and it is not expensive as other spectrum analyzers Cannot measure phase and transient events