Key Physics and Doppler Principles

Similar documents
Principles of Ultrasound Imaging Image Optimization

The Physics of Echo. The Physics of Echo. The Physics of Echo Is there pericardial calcification? 9/30/13

Ultrasound Beamforming and Image Formation. Jeremy J. Dahl

Optimisation of Image Acquisition Bordeaux 16th November J.S. McGhie W.B. Vletter R. Frowijn No disclosures

12/26/2017. Alberto Ardon M.D.

Chapter 4. Pulse Echo Imaging. where: d = distance v = velocity t = time

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Ultrasound Bioinstrumentation. Topic 2 (lecture 3) Beamforming

Lesson 06: Pulse-echo Imaging and Display Modes. These lessons contain 26 slides plus 15 multiple-choice questions.

Ultrasound Physics. History: Ultrasound 2/13/2019. Ultrasound

Artifacts. Artifacts. Causes. Imaging assumptions. Common terms used to describe US images. Common terms used to describe US images

Ultrasound & Artifacts

Photomultiplier Tube

3. Ultrasound Imaging(2)

Architecture of Quality Imaging Mary K. Henne, MS, CNMT, RDMS, RVT Ultrasound Education Specialist GE Healthcare

Physics of Ultrasound Ultrasound Imaging and Artifacts รศ.นพ.เดโช จ กราพาน ชก ล สาขาหท ยว ทยา, ภาคว ชาอาย รศาสตร คณะแพทยศาสตร ศ ร ราชพยาบาล

Ultrasound Imaging Ultr Michael Dadd 2007

Design Your Performance

Doppler in Obstetrics: book by K Nicolaides, G Rizzo, K Hecher. Chapter on Doppler ultrasound: principles and practice by Colin Deane

Lesson 06: Pulse-echo Imaging and Display Modes. This lesson contains 22 slides plus 15 multiple-choice questions.

Medical Imaging (EL582/BE620/GA4426)

Image Optimization: The Sonographer s Responsibility. Prepared by Cathy Daniels, EdD, RTR, RDMS, RDCS, RVT

Introduction to Ultrasound Physics

Nuove tecnologie per ecografia ad ultrasuoni: da 2D a 4D

Beyond Performance and Value

Introduction to Medical Engineering (Medical Imaging) Ultrasound Imaging. Ho Kyung Kim Pusan National University

A COMPACT SYSTEM WITH ADVANCED PERFORMANCE

Optical coherence tomography

ACOUSTIC MICRO IMAGING ANALYSIS METHODS FOR 3D PACKAGES

FREQUENTLY ASKED QUESTIONS

Lesson 02: Sound Wave Production. This lesson contains 24 slides plus 11 multiple-choice questions.

The Script of ZST + Presentation. MIS Upstream Marketing Team [ 日期 ]

4 Working With Scan Modes

Session: 2A NEW ULTRASOUND SYSTEMS Chair: H. Ermert University of Bochum 2A-1 10:30 a.m.

Quick Reference Guide

Physics of ultrasound

Physics of Ultrasound & Doppler. Sang Jae Rhee. MD., PhD. Division of Cardiovascular Medicine Wonkwang University Hospital

Doppler Ultrasound. Amanda Watson.

Virtual ultrasound sources

Fig. 1

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa. Joanna X.Qiao 1, Matthias Jobst 2

Digital Imaging CT & MR

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Introduction. Parametric Imaging. The Ultrasound Research Interface: A New Tool for Biomedical Investigations

Easy Ultrasonic Phased Array Inspection of Corrosion - Resistant Alloys and Dissimilar Weld Materials

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

CHAPTER 1 INTRODUCTION

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Printed in Japan E318

Ultrasound physical principles in today s technology


UNIVERSITY OF NAIROBI COLLEGE OF EDUCATION AND EXTERNAL STUDIES

SONOGRAPHIC PHYSICS, INSTRUMENTATION & DOPPLER REVIEW Part 3

Excellent Performance; Ease of Use

(A) 2f (B) 2 f (C) f ( D) 2 (E) 2

SIMULATION OF B-SCAN IMAGES FROM TWO-DIMENSIONAL TRANSDUCER ARRAYS: PART II - COMPARISONS BETWEEN LINEAR AND TWO-DIMENSIONALPHASED ARRAYS

Q5 VET. Compact, Affordable Color Doppler for VET

COMPUTER PHANTOMS FOR SIMULATING ULTRASOUND B-MODE AND CFM IMAGES

Ihor TROTS, Andrzej NOWICKI, Marcin LEWANDOWSKI

Echo Artifacts: The Cause and Solution

Multi-Element Synthetic Transmit Aperture Method in Medical Ultrasound Imaging Ihor Trots, Yuriy Tasinkevych, Andrzej Nowicki and Marcin Lewandowski

Retrospective Transmit Beamformation. Whitepaper. ACUSON SC2000 Volume Imaging Ultrasound System. Answers for life.

UGEO H60. Performance in Style. Features

M5 Diagnostic Ultrasound System

A Modified Synthetic Aperture Focussing Technique Utilising the Spatial Impulse Response of the Ultrasound Transducer

DC-6. Diagnostic Ultrasound System

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Endoscopic Ultrasonography System

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

Answer: TGC is needed to amplify echoes from deeper structures so that they appear as bright as similar structures located at more shallow depths.

SECTION 2 BROADBAND RF CHARACTERISTICS. 2.1 Frequency bands

CryoSat footprints. Aresys Technical Note. ESA Document REF. Issue 1.1 Date 6 March 2013 Pages 8. Michele Scagliola ARESYS S.r.l

Tomosynthesis and Motion

Multimodal simultaneous photoacoustic tomography, optical resolution microscopy and OCT system

Lesson 12: Doppler Principles. This lesson contains 50 slides plus 26 multiple-choice questions.

Diagnostic Ultrasound System. Operation Note

Parameter Estimation Techniques for Ultrasound Phase Reconstruction. Fatemeh Vakhshiteh Sept. 16, 2010

Lecture 08. Fundamentals of Lidar Remote Sensing (6)

monitoring device ought to find wide clinical application. available, while section three describes the Doppler interface with the B-scan machine.

Physics 3340 Spring Fourier Optics

Standard Guide for Evaluating Performance Characteristics of Phased-Array Ultrasonic Testing Instruments and Systems 1

ENDOSCOPIC ULTRASOUND SYSTEMS

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Explain what is meant by a photon and state one of its main properties [2]

A COST-EFFECTIVE METHOD FOR ULTRASOUND VOLUMETRIC IMAGING

Sonic Distance Sensors

Ultrasonic Linear Array Medical Imaging System

OPERATING MANUAL MINIDOP ES-100VX POCKET DOPPLER

MULTI-FREQUENCY ULTRASOUND IMAGING: PHANTOM STUDY

BEAM DISTORTION IN DOPPLER ULTRASOUND FLOW TEST RIGS: MEASUREMENT USING A STRING PHANTOM

Journal of Digital Imaging

Exercise 2: Simulation of ultrasound field using Field II

A new Sensor for the detection of low-flying small targets and small boats in a cluttered environment

Pulse Sequence Design and Image Procedures

INSPECTION OF THERMAL BARRIERS OF PRIMARY PUMPS WITH PHASED ARRAY PROBE AND PIEZOCOMPOSITE TECHNOLOGY

Transcription:

Key Physics and Doppler Principles Robert A. Levine, MD, FACE, ECNU Thyroid Center of New Hampshire Geisel School of Medicine at Dartmouth College AACE/ACE Advanced Neck Ultrasound Training Course

Disclosures: No relevant financial or corporate conflicts of interest. The use of investigational drugs will not be discussed

Image Optimization Create the sharpest image to allow tissue discrimination. Equipment factors: Quality of Transducer Quality of Electronics Image Enhancement and Compound Imaging User Adjustments: Depth, Gain, Frequency Focal zones Number and Location Compound Imaging Tissue Harmonic Imaging Dynamic range Doppler settings: Wall filter and PRF

Optimal Depth

Image Optimization Gain Overall Gain Time Gain Compensation Multiple channels corresponding to depth User adjustable to achieve best image quality at region of interest Focal Zone(s) Adjustable depth and number Greater number of zones slows refresh rate

Optimal Gain

Compare echotexture of thyroid parenchyma to strap muscles and SCM.

Optimal Time Gain Compensation

Resolution Resolution is the ability to discriminate two structures as separate entities Types of resolution : Axial (distance from the transducer) Lateral (transverse) Azimuthal (thickness of imaging plane)

Resolution AZIMUTHAL (up-down) AXIAL (distance from transducer) LATERAL (side to side)

Resolution Ability to discriminate two adjacent objects as separate entities. The narrower the beam, the better the lateral resolution. The higher the frequency the better the axial resolution. Poor focus Image Good focus

Focus and Resolution Focused beam width determines Lateral and Azimuthal Resolution Near field (Fresnel Zone) Large variations of intensity Far field (Fraunhofer Zone) Greater variation with greater distance. Focal Zone - Area of maximal narrowing Pulse duration (frequency) determines Axial Resolution (axial resolution = 1/2 spatial pulse length) Practical Consideration - As frequency increases, axial resolution improves, but depth of imaging decreases. The number and depth of the focal zones are often adjustable and indicated on the display

Adjustment of number and position of focal zones

Adjustment of number and position of focal zones

Single focal zone

Four focal zones

Frequency and Resolution Higher frequency gives better resolution. Higher frequency gives less penetration. Need to find best compromise for depth of interest

Image Optimization - Frequency Choose highest frequency (12-15 MHz) that allows adequate depth penetration. Lower frequencies (7-10 MHz) for deep structures or very obese subjects

Frequency and depth

Which of the following is true regarding ultrasound frequency? 1. Increasing frequency will increase depth of penetration. 2. Increasing frequency will improve resolution. 3. Increasing frequency will increase noise. 4. Both 1 and 2 are correct.

Advances in Technology Signal Processing Image Enhancement Noise reduction Edge sharpening Utilization of CT and MRI reconstruction algorithms Beam Steering Spatial compounding

Image Optimization- Compounding

Signal Processing Compunding

Comparison of standard and processed images

Effect of Compound Imaging on Artifacts Comet Tails

Effect of Compound imaging on Artifacts Edge Artifact and Enhancement

Effect of Compound Imaging on Spongiform Nodule

Image Optimization Dynamic range May increase conspicuity of subtle lesions

Doppler Shift

Color and Power Doppler Meritt, 1998

Color and Power Doppler Meritt, 1998

Color and Power Doppler Color Doppler Provides information regarding direction and velocity. More useful in vascular studies Power Doppler No information regarding velocity Less angle dependence Less noise Increased sensitivity for detection of flow

Doppler Lymph nodes In normal nodes vessels enter centrally at the hilus, and spread along the long axis. In malignant nodes aberrant vessels enter peripherally in the node capsule. Increased (disordered) vascularity may be seen peripherally and centrally.

Doppler of Nodes Demonstration of Chaotic or peripheral vascularity in malignant nodes Can be seen in reactive nodes Normal vascularity is reassuring Power Doppler for high sensitivity Use low wall filter Use a low PRF < 800 Low wall filter and low PRF both increase the sensitivity for detection of low flow.

Achieving the highest sensitivity with Doppler imaging. High Doppler sensitivity needed for lymph nodes. Power Doppler Maximum Doppler gain without noise. Low Pulse Repetition Frequency PRF < 800 Low wall filter.

PRF 1400 700

PRF 700 Wall filter varies

Image Optimization Summary and Conclusions High quality equipment is preferable, BUT a great ultrasonographer using low quality equipment will obtain better images than a lousy ultrasonographer with great equipment. I need to find out what type of piano Mozart played so I can sound like him. User adjustments of gain, depth, frequency, focal zones, dynamic range, spatial compounding, pulse repetition frequency, and wall filter will give the optimal image quality.