General information. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument.

Similar documents
JEOL 6500 User Manual

JEOL 6700 User Manual 05/18/2009

Check that the pneumatic hose is disconnected!!!! (unless your using the BSE detector, of course)

Title: Amray 1830 SEM#2 Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 03/18/2016

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

Using the Hitachi 3400-N VP-SEM

JSM 6060 LV SCANNING ELECTRON MICROSCOPE STANDARD OPERATING PROCEDURES

Dickinson College Department of Geology

Model SU3500 Scanning Electron Microscope

2. Raise HT to 200kVby following the procedure explained in 1.6.

SEM Training Notebook

Basic Operating Instructions for Strata Dual Beam 235 FIB/SEM

SEM Training Notebook

SEM OPERATION IN LOW VACUUM MODE

Jeol JEM Responsible personell: Endy ( ) Online booking is compulsory!

1. Preliminary sample preparation

1.1. Log on to the TUMI system (you cannot proceed further until this is done).

Basic Users Manual for Tecnai-F20 TEM

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

FE-SEM SU-8020 Operating manual (Preliminary version)

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

Operating the Hitachi 7100 Transmission Electron Microscope Electron Microscopy Core, University of Utah

JEOL JEM-1400 Transmission Electron Microscope Operating Instructions

Scanning electron microscope

STEM alignment procedures

Instructions for Tecnai a brief start up manual

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Scanning electron microscope

ZEISS EVO SOP. May 2017 ELECTRON OPTICS

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

User Operation of JEOL 1200 EX II

Please follow these instructions for use of the Philips CM100 TEM. Adopted from website below.

Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope

STANDARD OPERATING PROCEDURE: JEOL TEM-2100

Introduction of New Products

2 How to operate the microscope/obtain an image

Amray 3600 FESEM. Standard Operating Procedure. v2.2 modified by Bryan Cord. General Notes...3. Sample Loading...5. System Loading...

Operation Guide. Hitachi S-3400N. Variable Pressure Scanning Electron Microscope. with. Deben Peltier Coolstage

FEI Tecnai G 2 F20 Operating Procedures

1.1. In regular TEM imaging mode, find a region of interest and set it at eucentric height.

Transmission Electron Microscopy 9. The Instrument. Outline

RAITH e-line OPERATING INSTRUCTIONS

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

S200 Course LECTURE 1 TEM

1. Specimen Holder Removal, Loading, and Insertion

FEI Quanta 200 ESEM Basic instructions

SOP for Hitachi S-2150 Scanning Electron Microscope For review purposes only

Scanning Electron Microscope in Our Facility

LEO 912 TEM Short Manual. Prepared/copyrighted by RH Berg Danforth Plant Science Center

This document assumes the user is already familiar with basic operation of the instrument in TEM mode and use of the Microscope Control interface.

Introduction to Scanning Electron Microscopy

Protective Equipment Nitrile gloves for handling sample holder and safety glasses for filling liquid nitrogen dewar.

Standard Operating Procedure Hitachi UHR CFE SU8230 SEM

COMPACT MANUAL FOR GI USERS OF THE JEM 1400 FLASH BEGINNERS (For internal use only) Gray means additional information at the end of this mini-manual

MSE 460 TEM Lab 2: Basic Alignment and Operation of Microscope

Functions of the SEM subsystems

ALTURA EDS. Rev. 0915

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Scanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering

Section 1: TEM parts and functions... 2

Leading in Desktop SEM Imaging and Analysis

Schottky Emission VP FE-SEM

05/20/14 1. Philips CM200T. Standby Condition

Scanning Electron Microscope. Instructions for Use

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack).

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

MCR Scanning Electron Microscopy Laboratory Portfolio

NeoScope. Simple Operation to 40,000. Table Top SEM. Serving Advanced Technology

CATHODOLUMINESCENCE IMAGING UNIVERSITY OF ST ANDREWS

JEM-F200. Multi-purpose Electron Microscope. Scientific / Metrology Instruments Multi-purpose Electron Microscope

JEOL 5800LV SCANNING ELECTRON MICROSCOPE OPERATOR'S MANUAL

Scanning Electron Microscopy Laboratory Portfolio

Figure 1 The Raith 150 TWO

Scanning Electron Microscopy Basics and Applications

How to use the Jeol 1010 TEM of GI (Liesbeth own GI version)

Development of JEM-2800 High Throughput Electron Microscope

Scanning Electron Microscopy Laboratory Portfolio

Strata DB235 FESEM FIB

Module 4B7: VLSI Design, Technology, and CAD. Scanning Electron Microscopical Examination of CMOS Integrated Circuit

University of Washington Molecular Analysis Facility

Bruker Dimension Icon AFM Quick User s Guide

Bruker Dimension Icon AFM Quick User s Guide

Introduction: Why electrons?

MODULE I SCANNING ELECTRON MICROSCOPE (SEM)

MSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I

Secondary Electron Detector

RENISHAW INVIA RAMAN SPECTROMETER

Standard Operating Procedure

JEOL 2010 FasTEM & DigitalMicrograph User's Guide

Standard Operating Procedure Hitachi UHR CFE SU8230 SEM

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Micro-Image Capture 8 Installation Instructions & User Guide

SECONDARY ELECTRON DETECTION

USING LEICA AS LASER MICRODISSECTION (LMD6000) MICROSCOPE Written By Jungim Hur

CM20 USER GUIDE. Duncan Alexander, CIME 2010

Transcription:

JEOL JSM-7400F

Table of contents General information.. 3 The operation panel. 4 The different sample holders and inserting the samples.. 5 Turning on the beam... 6 Stage map control... 8 Correcting astigmatism... 9 How to save an image correctly. 10 Info obtained from the specimen 11 Different detectors on the system.. 12 Which kv should I use?... 13 Gentle beam.. 14 What does the probe current do?... 15 Should I change the working distance of the samples?... 16 Objective aperture 17 Simple alignment og the gun (only for MIC personnel)... 18 Turning system on and off (only for MIC personnel).. 19 Sample holders and how to insert the samples (only for MIC personnel).. 20 Charge-up and contamination 22 Troubleshooting 24

General information Never turn off the instrument and software! The ion pumps which create the high vacuum must never be turned off. There is also an automatic «flashing» (baking of the filament) performed once a day, so therefore never shut down the software. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument. When you have finished imaging, leave the instrument in high magnification (10.000) 3

There are four different viewing modes: quick 1 and 2, fine 1 and 2. Switch between low magnification (25-9500x) and high magnification (250-650.000x). RDC switches from full frame to reduced frame (useful for focussing and correcting astigmatism) These three buttons are for aligning the beam and should not be touched unless you know what to do. Press freeze to see the live image. Press ACB to get an auto-contrast-balance of your image. Press photo to take an image (it will take 85 seconds to scan an image). Turn the knob to change the magnification (scancoils will scan over a smaller region. These two knobs are used to align the stigmatism in x and y direction. Focussing knob. This will change the magnetic field and thereby change the focus. Adjust contrast and brightness to your taste. The ACB is very useful as a start point. 4

Date: Name: Specimen: The different sample holders We have a few different sample adapters for the SEM holder. MIC personnel will help you choose the one you need for you samples. Samples should not stick out more than 2-3mm above the sample holder. Samples should also be coated with palladium/gold or carbon prior imaging. Bad coating or no coating will give you drifting of sample and charging of electrons in addition to polluting the chamber environment. Remember to fill out the form with the sample positions. This will help you find the right sample once they are inside the instrument Inserting the holder into the main chamber is only done by MIC personnel! 5

MIC personnel will help you insert your samples into the microscope Once the samples are inside the main chamber, tell the software which holder is inserted. The 6 holder is mostly used and called multiple holder. All the holders have been measured in order for the system to let you know when you arrive to a dangerous position (sample will touch lens and so on). Click exchange when you want to move the holder into the exchange position. You only do this when you want to physically remove the specimen. 6

Turning on the beam Our system is operating with a field emission. This means cleaner images due to a more stable current in a small beam. The system therefore operates at a lower vacuum with a more sensitive (and expensive!) pump system. 1. Check the vacuum. Click onto PVG and the penning gauge will pop up at the lover left side of your screen. When the vacuum shows x.xxe-005 Pa, you can turn on the beam by clicking on HT (will be blue). If you turn on the HT too early, there will be a lot of molecules accumulating onto the filament and the image and resolution will suffer. 2. When the beam is on, the HT icon becomes green and your will see the emission current rising to 20.0µA (expresses how many electrons leave the filament). 3. Notice the µa decreasing (usually at the beginning of a session) and at some point the reset button becomes yellow. Press the «reset» button and the image quality will increase a bit. 7

Stage map control It is important to use this map to orientate yourself to your samples in the holder. If you are using the 6 possition holder, the different stubs will be located as indicated under. The two white lines cross at the possition where you are now (red cross). If you start rotating the sample, the green line at the bottom will be you referance. 8

Correcting astigmatism Out of focus Astigmatism In focus Use the small window (RDC) to focus and correct for the astigmatism in your image. You will have to correct the astigmatism after changing kv, probe current, wd and focus. Try to focus as well as possible. If the image is still blurry and structures look drawn in one/several directions: Focus as well as possible Use the Y knob to find the shapest image or make the structure less drawn. Use now the X knob to do the same. Focus again. Use the Y knob again. Use the X knob again. And so on.. If you are able to see pores and cracs at high magnification, then your sample is in focus and you have corrected for the astigmatism. 9

Information obtained from the specimen A secondary electron have an energy less than 50 ev and are produced produced when an electron from the primary beam collides with an electron from a specimen atom and loses energy to it. These electrons originate within a few nm from the sample surface. Primary electron beam Secondary electrons Backscatter electron consist of high-energy electrons originating in the electron beam, that are reflected or back-scattered out of the specimen interaction volume by elastic scattering interactions with specimen atoms. Therefore heavy elements (high atomic number) backscatter electrons more strongly than light elements. The backscatter detector is therefore used to detect contrast between areas with different chemical composition. Backscattered electrons X-rays 10

The different detectors on the system For secondary electron imaging: Lei (lower detector image) is the large detector on the side and works in the range of wd 6-25 mm. Sei (semi in lens) works in the range of wd 1,5-6 mm Backscatter eletron imaging: COMPO (A+B) and TOPO (A-B) is the donut detector. IR camera must be off! Adjust focus with Lei before COMPO is used. COMPO shows contrast according to the difference between the atomic numbers comprising the specimen (normally used prior to X-ray analysis. TOPO shows contrast according to the ruggedness of the surface of the specimen (used to judge shape of the specimen) 11

Whick kv should I use? This depends on your sample and what you want to image. The higher kv the «harder» the electrons are. Sample surface and coating is important with high kv. There is more damage done on you sample at high kv. The higher the kv the more the electrons penetrate into your sample and therefore the less surface structures are visible. Low kv more surface structures High kv more edge effect 12

Gentle beam A B C The gentle beam (GB) method slows down the electron beam just in front of the specimen, reducing the electron beam energy while keeping the electron probe diameter small. Compared to normal scanning, this method will give you a high resolution and small probe diameter at low accelerating voltage (< 4 kv). To use GB mode, click onto column icon (A). This will open the column-setting window (B). Click onto GB (C) in order to change over to gentle beam mode. The accelerating voltage will automatically og down to 4kV. You can lower it more if you need. 13

What does the probe current do? The probe current tells you how many electrons hit the specimen. The higher the probe current the better the S/N becomes and the smother the image looks. The smaller the probe current the sharper the image becaomes, but you will see it as grainy. Probe 8 Probe 10 14

Should I change the working distance of the samples? In general, the smaller the working distance, the better the resolution. What you will notice though is the reduced depth of field. So unless you really need the high resolution (with high magnification) you keep a larger distance due to the depth of field. The working distance is also limited depending on the sample holder and which detector you use (lei or sei). Z = 15 mm Z = 8 mm 15

How to save an image correctly Once the scanning has finished, you will be asked to print the image, choose cancel. 1. Go to File - Image File Handler. 2. Select export and choose the users save here, shortcut is on the desktop. 3. Create a folder with your name and save you images as Bitmap bmp. If you do not follow this path and instead save you image through File Image Save As, you will loose the data information in you image (magnification, detector used, working distance etc). 16

Influence of objective aperture diameter We normally use 4 and that s the default. OL = 1 OL = 4 17

Simple alignment of the gun (only for MIC personnel) Gun alignement Gjøres ved lav magnification Probe current helt opp (lens clear) Still X og Y for å få mest lys CL stigmator (condensor lens) Gjøres på max probe current Bruk X og Y for å stille skarpt Beam alignment Bruk probe 7 Vha wobbler, slitt X og Y, skal blinke på stedet Gun alignment (sjekk på ny) Beam alignment (sjekk på ny) Stig center X Bruk wobbler Still X og Y (skal ligge i ro) OL stigmator (objective lens) Still X og Y for skarpest mulig bilde (husk å fokusere) 18

Turning system on and off MIC personnel only It is crucial that the system is left ON all the time (due to the ion pumps). If you notice a power down, notify MIC personnel or personnel at fellesavdeling as soon as possible! If the instrument is cut off the power for more than 4 hours it will be necessary to perform column backing and this has to be done by JEOL service technicians! Turning the system ON: 1. Turn on vacuum switch (behind, careful not to touch the main switch.unless this is turned off). 2. Press the ON button of the power switch for the operation system (under the front table). 3. Turn on the software. Turning the system OFF: 3-2-1 Calibration of the stage: If the PC has been turned off, you will need to recalibrate the specimen stage. Open the PC-SEM software. Click OK when asked to calibrate. Click Auto in the stage maintenance dialog box. Click ok after it has benn carried out. 19

Inserting and removing samples from the Jeol JSM-7400F Inserting Use gloves when handling the sample holder. Place samples into the holder and tighten the screws so the samples are fixed. Place the insert into the holder (the correct way!) and check that the o-ring on the door is in position and that it is free from debris. Bring the sample into the pre-chamber. Close the door and attach the clamp. Press VENT. EVAC and it will start blinking. After a few minutes is stops blinking (this depends on the sample) and you will hear the click sound as the door opens from pre- to main chamber. When EVAC is not blinking any more, the holder can be moved from the pre-chamber to the main chamber. I recommend using the IR camera, as the insertion of the sample holder is critical and should be done with uttermost care. The handle (stick) is pulled out 5mm before it is pulled 90 downwards (important!). Carefully push the handle inside the pre-chamber. Watch (IR camera) the sample holder being placed onto the main stage. Carefully retract the holder and watch that the sample holder is well fixed onto the stage. Bring the handle all the way out (remember the 5mm!) before pulling 90 upwards. Turn off the IR camera. Go to Stage-exchange and check that you have the correct insert (precaution - this has to do with working distance of the different inserts and will prevent you from crashing your sample into the objective). Wait for the vacuum to reach -005 before turning on the HT (blue). 20

Inserting and removing samples from the Jeol JSM-7400F Extracting Use gloves when handling the sample holder. Turn off the HT before starting the extraction. Go to Stage-exchange and press exchange. You will hear the stage moving back into start position. When it stops moving, it s ready for extraction. Turn on the IR camera. Start viewing. Pull out the handle (stick) 5 mm before pulling the handle 90 downwards. Push slowly the handle all the way in. Observe the grabbing of the insert and slowly pull the sample holder into the pre-chamber. Bring the handle all the way out (remember the 5 mm) before pulling 90 upwards. Turn off the IR camera. Go to maintenance-gun and leave the information on the screen. Never turn off the software, there is an automated Flashing (baking of filament) twice every 24 hours. 21

Charge-up Main problem will be that your sampe is not grounded and you will notice it as abnormal contrast and image deformation and shift. 1. Coat you sample better og ground it better. 2. Reduce the probe current. 3. Lover the accelerating voltage (the kv). 4. Try tilting the sample a bit. 22

Contamination Have you ever seen this phenomen on your sample after irradiating an area for a long time? This is caused by residual gass in the vicinity of the speciment beeing struck by the electron probe (gas brought in with the sample or gas that the specimen itself gived out). To prevent specimen contamination: Use the minimum amount of double-sided adhesive tape or conductive pain (silver paint) and completely dry it before putting into the instrument. Use the smallest possible biological specimens. Coat the surface with a conductive material. 23

Troubleshooting Are all the buttons green? If not, notify Endy 24