Function s Datasheet Function s GL7- DISP GL7- DISP GL7 - SSD GL7 - DCO Display Display device 5.7- inch TFT color LCD monitor (VGA: 640 x 480 dots) Operation Touchpanel and cursor keys *1 Touchpanel Capacitive type touch panel; Operated by finger or proprietary pen Displayed language English, French, German, Chinese, Korean, Japan ese Screen saver Turns off backlight by10 s, 30s, 1 min, 20 min, 5 min, 10 min, 30 min or 60 min Displayed information WaveformY- T + digital values, waveform only, digital values only, waveform XY Connection cable LAN cable (CAT5, straight, max. 10 m) *2 Standardaccessories Bracket for slanted mount, connection cable (40 cm), ground cable, screws External dimensions [WxDxH] approx. 187 x 34.5 x 119 mm (excluding projections) approx. 530 g Notes: 1. Most operations can be selected by both the touch panel and keys. 2. When the display module is mounted at an angle using the bracket, the display module is connected to the main module by a LAN cable that is attached to the module as a standard accessory GL7- SSD SSD Memory Solid state disc (SSD), form factor: 2.5- inch HDD Capacity approx.64 GB (the file size of he captured data is limited up to GB) 1 to 2 modules max. 1 MSamples/s (1 µs) Sampling rate 3 to 4 modules max. 500 ksamples/s (2 µs) (interval) *3 5 to 10 modules max. 200 ksamples/s (5 µs) External dimensions [WxDxH] approx.770 g Notes: 3. The sampling speed in the GL7000 is limited to the fastest sampling speed of attached amplifier module. When the specified sampling speed is faster than the module, the sampling is done in fastest sampling on the module. The same value is stored to the memory device in the specified sampling speed until data is renewed by the next sampling. GL7- DCO Number of output channels Output connector Output method Sampling rate (interval) Output target Output range Voltage Output 8 channels SMA connector All channels common ground 100 ksamples/s (10 µs) Voltage module, voltage /temperature modul e, high -speedvoltage m odule, high voltage modul e, DC strain module, charge/vibration module - Sampling interval from 10 µs - Temperature and humidity data is not compatible - Sine wave, pulsed wave (Duty cycle can be set when creating output data.), ramp wave, triangle wave, simple arbitrary waveform, DC voltage can be output by creating data with dedicated PC software. - Input s ignal can be recorded with input type module during output signal is generated from voltage output module. ±1 V, ±2 V, ±5 V, ±10 V Due to continuous product development, VES PLOTER and partners reserve the right to vary the foregoing details without prior notice. Page 1/ 1 Version, 02/2015 VES PLOTER s.c. ul. Chojnowska 6c, 03-583 Warszawa
GL7- V GL7 - HSV GL7 - HV GL7 - M Datasheet GL7- V GL7 - HSV GL7 - HV GL7 - M The s for voltage GL7- V, high - speed voltage GL7- HSV, high voltage GL7- HV and voltage/temperature GL7 - M are optional modules of data platform GL7000. Specifications Voltage GL7- V The GL7- V is suited for voltage measurement for sensor output and battery cells (Displacement, pressure, wind speed etc.). GL7- V 10 channels All channels isolated unbalanced input, simultaneous sampling, M3 screw terminals Sampling rate (interval) 1 ksamples/s to 1 Sample/h (1 ms to 1 h) Measurement range 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V, 20 V, 50 V, 100 V and 1-5 V AD converter Successive Approximation type, 16 bits (effective resolution : 1/40000 of measuring full range) betweenterminals +/ - Range 100 mv to 1 V: 60 Vpp; range 2 V to 100 V: 100 Vpp Max. input voltage between channels 60 Vpp between channel / GND 60 Vpp Max.voltage between channels 1000 Vss for 1 minute between channel / GND 1000 Vss for 1 minute Isolationresistance between channel / GND Min. 50 MΩ (at 500 VDC) Common mode rejection ratio Min. 90 db (50/60 Hz, signal source impedan ce : max. 300 Ω) Frequency response DC to 1 khz (at +1/- 3 db) Filter (low pass) Off, Line (1.5 Hz), 5 Hz, 50 Hz, 500 Hz (at - 3 db, 6 db/ oct) approx. 49,2 x 136 x 160 mm (excluding projections) approx. 840 g Specifications High - Speed Voltage GL7- HSV The GL7- HSV is suited for inverter measurements, vibration testing and drop tests. GL7- HSV 4 channels All channels isolated unbalanced input, simultaneous sampling, BNC connector Sampling rate (interval) 1 MSamples/s to to 1h) Measurement range 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V, 20 V, 50 V, 100 V and 1-5 V AD converter Successive Approximation type, 16 bits (effective resolution: 1/40000 of measuring full range) between terminals +/- Range 100 mv to 1 V: 60 Vpp; range 2 V to 100 V: 100 Vpp Max. input voltage between channels 60 Vpp between channel/ GND 60 Vpp Max. between channels 1000 Vss for 1 minute voltage between channel / GND 1000 Vss for 1 minute Isolation resistance between channel / GND Min. 50 MΩ (at 500 VDC) Common mode rejection ratio Min. 90 db (50/60 Hz, signal source impedance: max. 300 Ω) Frequency response DC to 200 khz (at +1/- 3 db) Filter (low pass) Off, Line (1.5 Hz), 5 Hz, 50 Hz, 500 Hz, 5 khz, 50 khz (at - 3dB, 6dB/oct) approx. 740 g
Specifications High Voltage GL7- HV The GL7- HSV is suited for i.e. power supply line and electric vehicle batteries etc. GL7- HV 2 channels Input connector Isolated BNC connector All channels isolated unbalanced input, simultaneous sampling Sampling rate (interval) 1 MSamples/s to 1 Sample/h (1 µs to 1 h) Input coupling AC, DC, AC - RMS, DC - RMS Measurement AC, DC 2 V, 5 V, 10 V, 20 V, 50 V, 100 V, 200 V, 500 V, 1 000 V range AC- RMS, DC- RMS 1 Vrms, 2 Vrms, 5 Vrms, 10 Vrms, 20 Vrms, 50 V rms, 100 Vrms, 200 V rms, 500 V rms Successive Approximation type, 16 bits A/ D converter (effective resolution: AC, DC 1/40000 of measuring full range AC- RMS, DC- RMS 1/20000 of measuring full range) Input signal source resistance 1 kω or less between terminals +/- 1000 Vpp Max. input voltage between channels 300 VACrms between channel/ GND 300 VACrms Max. between channels 2300 VACrms for 1 minute voltage between channel / GND 2300 VACrms for 1 minute Isolation resistance between channel / GND Min. 50 MΩ (at 500 VDC) Common mode rejection ratio Min. 90 db (50/60 Hz, signal source impedance: max. 300 Ω) Frequency response DC: DC to 200 khz (+1/- 3 db); AC: 4 Hz to 200 khz (+1/- 4.5 db) Filter Off, Line (1.5 Hz), 5 Hz, 50 Hz, 500 Hz, 5 khz, 50 khz (at - 3dB, 6dB/oct) approx. 740 g Specifications Voltage /Temperature GL7- M The GL7- HSV is suited for i.e. measurement of internal temperature and working voltage of samples within environmental test chamber. GL7- M 10 channels All channels isolated balanced input, scans channels for sampling, M3 screw terminals Sampling rate (interval) 100 Samples/s to 1 Sample/h (10 ms to 1 h) Voltage 20 mv, 50 mv, 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V, 20 V, 50 V and 1-5 V Measurement range Temperature Thermocouple: K, J, E, T, R, S, B, N and W (WRe5-26), RTD: Pt100, JPt100 (JIS), Pt1000 (IEC751) Humidity*1 0 100 % RH (using scaling function in 1V range, humidity sensor B- 530) RJ compensation Select internal or external A/ D converter Sigma- Deltatype, 16 bits (effective resolution : 1/40000 of measuring full range) between terminals +/- 60 Vpp Max. input voltage between channels 60 Vpp between channel / GND 60 Vpp Max. voltage between channels 350 Vpp for 1 minute between channel / GND 350 Vss f or 1 minute Isolation resistance between channel / GND min. 50 MΩ (at 500 VDC) Common mode rejection ratio Min. 90 db (50/60 Hz, signal source i mpedance : max. 300 Ω) Off, 2, 5, 10, 20, 40 ( Moving average in selected number. Filter When the sample is longer than 5 seconds, the data sampled in the sub -sample (5 seconds) will be used for creating the average value). 5V output Driving the humidity sensor B -530, 1 channel approx.770 g Notes: 1. Using optional humidity sensor (B- 530). Due to continuous product development, VES PLOTER and partners reserve the right to vary the foregoing details without prior notice. Page 2/ 2 Version, 02/2015 VES PLOTER s.c. ul. Chojnowska 6c, 03-583 Warszawa
Input GL7- L/P Datasheet GL7- L/P The Input Logic / Pulse isan optional module for data platform GL7000. The module is operated in logic or pulse mod With pulse mode the following measurement modes are available: rotation, accumulation and instant count. Specifications GL7- L/P 16 channels All channels common ground, simultaneous sampling, circular connector (4 ch/connector) Sampling rate Logic mode Up to 1 MSamples/s ( 1 µs) (interval) Pulse mode Up to 10 k Samples/s ( 100 µs) Measurement mode Selecting of the Logic input mode or Pulse input mode *4 Mode Pulse Rotation count (RPM), accumulating count, instant count Rotation count Function Counting the number of pulses per sampling interval and then it is converted to RPM (RPM) Span 50 rpm, 500 rpm, 5 k rpm, 50 krpm, 500 krpm, 5 Mrpm, 50 Mrpm, 500 Mrpm Accumulating Function Accumulating the number of pulses from start of measurement count Span 50 c, 500 c, 5 k c, 50 k c, 500 k c, 5 Mc, 50 Mc, 500 M c (c = counts) Instant count Function Counting the number of pulses per sampling interval (count is reset at each sampling) Span 50 c, 500 c, 5 kc, 50 k c, 500 k c, 5 Mc, 50 Mc, 500 Mc Max. input frequency 1 MHz Max. number of counts 15 Mc (24 bits counter is used) Input signal Voltage range 0 +24 V (common ground ) Signal type Contact (Relay), Open Collector, Voltage Threshold approx.2.5 V Hysteresis approx. 0.5 V (2.5 3 V) OFF or ON (- 3 db at 50 Hz) approx.700 g Filter Notes: 1. The measuring mode is set in each module (16 channels). In Logic mode, up to 7 modules can be attached to one main module (max. 112 channels). In Pulse mode, up to 2 module s can be attached to one main module (max. 32 channels). The maximum number of channels are limited to up to 112 channels Due to continuous product development, VES PLOTER and partners reserve the right to vary the foregoing details without prior notice. Page 1/ 1 Version, 02/2015
ε ε ε ε 1. 2. VES PLOTER s.c. ul. Chojnowska 6c, 03-583 Warszawa
VES PLOTER s.c. ul. Chojnowska 6c, 03-583 Warszawa