Product Data Sheet 3254 J/2H3P

Similar documents
Product Data Sheet 3252J/2H3PU

Product Data Sheet 8452/2 GHHP

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet 6424/2HP-210

Product Data Sheet 8214 J/2H4P

Product Data Sheet 622/2HHP-021

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet 6314/2TDHP. The engineer's choice

Product Data Sheet DV4112/2NP-201

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet RER225-63/18/2TDO- 406

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

B1793 AC Blower Innovation in Motion

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL NOISE MEASUREMENT RELIABILITY PRODUCT LABEL...

2-02 Start voltage The voltage that enable to start the fan by sudden switch on.

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

DC axial compact fan

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

SPECIFICATION FOR APPROVAL

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

AC axial compact fan

Rotary Measurement Technology Incremental Encoders

CUSTOMER: ARCERA EU MODEL NO: 9225 (CeraDyna Fan) PART NO: FD1290-AP181E3AL DATE: CUSTOMER APPROVAL. Taiwan. Page 1 of 12 REV.

DB Motorized Impeller

Specification For Approval

AC diagonal compact fan

-1 ] temperature life [V]

Power Supplies 3. SDN-C Compact DIN Rail Series

EC centrifugal fan. backward curved, single inlet

9WL type. Rated current Rated input. Rated speed [min -1 ]

AC axial compact fan

Specification For Approval

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

DB Motorized Impeller

Specification For Approval

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

EC centrifugal fan. forward curved, dual inlet with housing (flange)

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

Absolute encoders - SSI

NEW PRODUCT INFORMATION

SPECIFICATION FOR APPROVAL

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

DB Motorized Impeller

Online data sheet DFS60A-TEPZ00S09 DFS60 INCREMENTAL ENCODERS

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Rotary Position Technology Incremental Encoders

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

SPECIFICATION FOR APPROVAL

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

DC Axial Fans. ebm-papst St. Georgen. Noise

MODEL: M2DYS SEN TRONIC AG

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Transformers, Power Supply Units and Socket Outlets

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

VF-nC1 Adjustable Speed Drive Engineering Specification

08/07/2015

AC centrifugal fan. backward curved

NEW PRODUCT INFORMATION

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

DC Axial Fans. ebm-papst St. Georgen. Ball Bearings. Noise

Absolute Encoders Singleturn

Power supply CP-D 24/4.2 Primary switch mode power supply

AC centrifugal fan. forward curved, single inlet with housing (flange)

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

AC centrifugal fan. forward curved, single inlet with housing (flange)

175 mm 69 mm Specifications

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

08/07/2015

RoHS. High shaft load capacity. Shock / vibration resistant

Absolute Encoders Multiturn

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

DRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach

Theta 20A / 20V. Technical Data Sheet. Special Features

Transcription:

3254 J/2H3P INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 5 3.1 Operating Data - Electrical Interface - Input... 5 3.2 Electrical Operating Data... 7 3.3 Operating Data - Electrical Interface - Output... 8 3.4 Electrical Features... 9 3.5 Aerodynamics... 10 3.6 Sound Data... 11 4 Environment... 11 4.1 General... 11 4.2 Climatic Requirements*)... 11 4.3 Mechanical Requirements... 12 5 Safety... 13 5.1 Electrical Safety... 13 5.2 Approval Tests... 13 6 Reliability... 13 6.1 General... 13 11/25/2015 page 2 of 14

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position Fan Clockwise Air outlet over struts Ball bearing Any 2 Mechanics 2.1 General Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 92,0 mm 92,0 mm 38,0 mm 0,25 kg Plastic Plastic wire outlet corner: 50 Ncm remaining corners: 110 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Wires Lead wire length L = 310 mm Tolerance Wire size (AWG) 22 Insulation diameter 1,7 mm Contact See drawing +- 10,0 mm 11/25/2015 page 3 of 14

Colour Operation Wire 1 red + UB Wire 2 blue - GND Wire 3 violet PWM Wire 4 white Tacho The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 11/25/2015 page 4 of 14

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input PWM Features Inpute type PWM - Frequency Open collector 1 khz - 30 khz Typical: 25 khz 0,2 V Max. voltage for logic "Low" Maximum source current short circuit current <= 1 ma Typical time until warm restart After shutdown by PWM ~ 9 s Characteristics 11/25/2015 page 5 of 14

Schematics 11/25/2015 page 6 of 14

3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Name Condition PWM 0001 PWM: 100 %; f: 25 khz f: 1 khz f: 30 khz Features Condition Symbol Values Voltage range p = 0 U 14,0 V 26,4 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 10,6 W 31,5 W 41,0 W Tolerance P +- 20 % +- 15 % +- 15 % PWM 0001 Current consumption p = 0 760 ma 1.310 ma 1.550 ma Tolerance I +- 20 % +- 15 % +- 20 % PWM 0001 Speed p = 0 5.000 1/min 7.450 1/min 7.900 1/min Tolerance n +- 15 % +- 10 % +- 15 % PWM 0001 Starting current consumption <= 3.100 ma 11/25/2015 page 7 of 14

Name Condition PWM 0002 PWM: 50 %; f: 25 khz f: 1 khz f: 30 khz Features Condition Symbol Values Voltage range p = 0 U 14,0 V 26,4 V Nominal voltage p = 0 U N 24,0 V Power consumption p = 0 4,1 W 13 W 17,2 W P +- 25 % +- 20 % +- 20 % Tolerance PWM 0002 Current consumption p = 0 290 ma 540 ma 710 ma I +- 25 % +- 20 % +- 25 % Tolerance PWM 0002 Speed p = 0 3.200 1/min 5.400 1/min 5.800 1/min n +- 20 % +- 15 % +- 20 % Tolerance PWM 0002 3.3 Operating Data - Electrical Interface - Output Tacho type /2 (open collector) 11/25/2015 page 8 of 14

Features Note Values Tacho operating voltage (UBS) <= 60 V Tacho signal Low I sink: 2 ma <= 0,4 V Tacho signal High I source: 0 ma 60 V Maximum sink current <= 4 ma External resistor External resistor Ra from UBS to US required. All voltages measured to GND. Tacho frequency (3 x n) / 60 Tacho isolated from motor No Slew rate => 0,5 V/us Alarm type None 3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor Speed-Controlled Rectifying diode IF <= 200 ua Auto restart approx. 3.600 ma Typical: 1 s / 9 s t3: 0,7 s... 1,3 s t4: 6,5 s... 11,5 s First pulse t5 typical 1,6s (1,3.. 1,9s) followed by t4. Afterwards cyclical t3/t4. 11/25/2015 page 9 of 14

3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 7.450 1/min at free air flow PWM 100 %; f: 25 khz f: 1 khz f: 30 khz Max. free-air flow ( p = 0 / = max.) 270,0 m3/h Max. static pressure ( p = max. / =0) 370 Pa 11/25/2015 page 10 of 14

3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 7.450 1/min at free air flow Optimal operating point PWM 100 %; f: 25 khz PWM min.: ; f: 1 khz PWM max.:; f: 30 khz 191,0 m3/h @ 176 Pa Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 7,6 bel(a) 64,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 70 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 85 C 4.2 Climatic Requirements*) Humidity requirements humid heat, constant; according to DIN EN 60068-2- 78, 14 days Water exposure None Dust requirements None Salt fog requirements None *) Permittet application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. 11/25/2015 page 11 of 14

4.3 Mechanical Requirements severity level stationary use 1 storage / transportation storage / transportation stationary use stationary use Random vibration not in use IEC 60068-2-64 Frequency range / ASD G RMS Axes of vibration Test duration Bump not in use IEC 60068-2-29 Shock spectrum Acceleration Duration Number of bumps (+X, -X, -Y, +Y, -Z, +Z) Total bumps Random vibration in use IEC 60068-2-64 Frequency range / ASD G RMS Axes of vibration Test duration Bump in use IEC 60068-2-29 Shock spectrum Acceleration Duration Number of bumps (+X, -X, -Y, +Y, -Z, +Z) Total bumps Random vibration 5-20 Hz : 1,0 m² / s³ 20-500 Hz : - 3 db / Oct 0,91 G 3 3 x 30 min Bump half sine 18 G 6 ms 100 in each direction 600 Random vibration 5-10 Hz : +6 db / Oct 10-50 Hz : 1,0 m 2 / s 3 50-200 Hz : - 6 db / Oct 0,65 G 3 3 x 30 min Bump half sine 5 G 11 ms 100 in each direction 600 11/25/2015 page 12 of 14

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification No 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. 85.000 h 42.500 h 11/25/2015 page 13 of 14