COMMERCIAL AIR CONDITIONERS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N

Similar documents
Technical Information

SPLIT DUCTED UNIT TECHNICAL SELECTION DATA SRA141C / SRA140E SPECIFICATION SUMMARY UNIT FEATURES CONTROL FEATURES CONTROL OPTIONS. PLENUMS (Optional)

Product Launch Package. Refrigeration Marketing Units Emerson Climate Technologies Europe

COMPACT CASSETTE TYPE AIR CONDITIONER

Copeland Digital Scroll

VAV Rectangular Terminal Units

4 T V H A D A A

Multi Room MULTIELITE. Flexible and economical multi room comfort. That s better. That s Actron.

RUND Decorative Column

- Clamshell - OD-Mounted Pipe Cutting and Beveling Machine. Split frame. cutting and beveling simultaneously

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

Honeywell. W7620 Zone Controller Water Source Heat Pump A. GENERAL RESIDENTIAL AND BUILDING CONTROL GUIDE SPECIFICATION FOR THE ENGINEER

Power Proportional Distribution (PPD)

DESIGN & TECHNICAL MANUAL

GEA Screw Packages. Plug & play compressor units for industrial refrigeration and air conditioning

AIR COOLED CONDENSERS with EC AXIAL FANS

CNC Machining Center BAZ 895n IQ

Digital flow transmitter for continuous flow measurement

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

PRESS RELEASE. Let s create your success! with GEA at Chillventa 2016

Code. Edition 04/2013. CPA Screw Air Compressors. Parts List Book

2.14 Main Cable Type HO7RN-F4G10-15 Metres each Chiller Tank Capacity- 75 Litres Compressor- 3.5 Tons Refrigeration type

Communicative heating controller

ICARUS ELECTRONIC GAS VOLUME CONVERTER

PARTS CATALOG R410A. September 2008 AIR TO WATER HEAT PUMP. No. OCB439 REVISED EDITION-A. [Service Ref.] [model name]

Benchtop Incubator Shakers

Technical Supplies & Services Co. L.L.C.

ADDENDUM NO. 4 November 15, Page 1

13acd MERIT SERIES R 22 A I R C O N D I T I O N E R S. SEER up to to 5 Tons Cooling Capacity 17,500 to 60,000 Btuh

RS /E-EV BLU SERIES

Digital Room Sensor Technical Guide

SUPER INVERTER SERIES MULTI TYPE. Service Manual 2018

PARTS CATALOG R410A. No. OCB603 REVISED EDITION-A. March 2016 HFC SUZ-KA25VA5.TH-ET SUZ-KA35VA5.TH-ET SUZ-KA50VA5.TH-ET SUZ-KA60VA5.

CONTROL MANUAL. Dry-Pic 09PE - 09VE

SONOMETER TM 1100 Ultrasonic compact energy meter

RS /M MZ SERIES

SONOMETER TM 1100 Ultrasonic compact energy meter

Weeke Machining Center, Model BP-100 Optimat

TPV 1200 BTB. Variable Displacement Closed Loop System Axial Piston Compact Tandem Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 160 / 0516 / E

TSE. Turbomiser. Condenserless water chiller with centrifugal compressors to be connected with a remote. for indoor installation

INSTALLATION MANUAL. Address card EKAC200A

GV60 PLUS. GV60 PLUS Electronic Ignition Remote Control. used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD

Digital flow ELEMENT transmitter for continuous flow measurement

VX-3000 Series Voice Alarm and Public Address System

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH

Integrations GW Programming manual

Weeke CNC Machining Center, Model BP-140 K ATC Optimat

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

SUZ-KA25VA3.TH SUZ-KA35VA3.TH SUZ-KA50VA3.TH SUZ-KA60VA3.TH SUZ-KA71VA3.TH

IntesisBox DK-AC-ENO-1C

Chillers for the industrial refrigeration and air conditioning

Digital flow ELEMENT transmitter for continuous flow measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

TECHNICAL SUPPORT MANUAL Fan Coils FXM4X

Weeke CNC Machining Center, Model BHC 350 4/10 Optimat

Outdoor units. Specifications

Commercial Refrigeration Price List

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Electromagnetic Flow Transmitter

AEROCONNECT 1B NA C Control manual

CELES MP Flexible - Compact - High Efficiency. Induction Heating - Power from 2 to 12 kw - Frequency from 20 khz to 2 MHz.

Tangential Fans - Basic principles. Expertise, performance, innovation

USE OF INVERTERS WITH COPELAND STREAM COMPRESSORS

Introduction to BAS Technology

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

PureAir. Oil-less Compressors

GEA Grasso screw packages. The full range of GEA Grasso screw packages. engineering for a better world. GEA Refrigeration Technologies

INLINE flowmeter for continuous flow measurement

PARTS CATALOG R410A. January 2012 PUHZ-HW112YHA PUHZ-HW112YHA-BS PUHZ-HW140VHA PUHZ-HW140VHA-BS PUHZ-HW140YHA PUHZ-HW140YHA-BS PUHZ-HW140VHA2R2-BS

Self-learning Room Temperature Controller Receiver

Control solutions Biofloor

Satellite Testing. Prepared by. A.Kaviyarasu Assistant Professor Department of Aerospace Engineering Madras Institute Of Technology Chromepet, Chennai

MODUBLOC MB SE SERIES

Reciprocating compressors for industrial refrigeration

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

FD 125 Large-Format Card Cutter

Repair Parts List REFRIGERATOR MODEL NUMBER JS48SEDBDA. When requesting service or ordering parts, always provide the following information:

Intelligent Compact Controller

Digital flowmeter for continuous flow measurement

R PROFLAME Instruction Book Collection

Ultrasonic level transmitter, non-contact

Digital flowmeter for continuous flow measurement

EFC 3600 Frequency converter for higher energy efficiency and improved process control


Wing Gate Instructions. Applicable Models: FB1000 / FB3000 FB1200 / FB3200 Version: 1.0 Date: Jun. 2016

Fast, precise, powerful

R&D TECHNICAL SPECIFI

Weeke CNC Machining Center, Model BP-140 ATC Optimat

Programmable transmitter of temperature, relative humidity and other derived humidity values with 4-20 ma outputs Instruction Manual

technical data air conditioning systems BS box BSVQ-PV1

Evaporator E2 Series. Innovative Refrigeration Solutions. Medium & Low Temperature Models. Issue: 05/14

TROUBLESHOOTING. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

TECHNICAL SPECIFICATIONS. FOR AN MRBR 7.0 TESLA / 160mm ACTIVELY SHIELDED ROOM TEMPERATURE BORE MAGNET SYSTEM

1.0 INTRODUCTION DEFINITIONS DRAWING CONTROL PREPARATION OF SPECIFICATIONS AND DATASHEETS... 5

RS /E-EV BLU SERIES

Micro-ISO Automotive Relay. (Unit: mm inch)

CONTROLS CS-I. MFDC/AC Inverter Weld Control

Operation Instruction Manual KAM-TC1000. Precision Temperature Controller

MC16 Mini Vacuum Pressure Casting Machine

Transcription:

COMMERCIAL AIR CONDITIONERS DIGITAL SCROLL SYSTEMS M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation and procedures comply with ISO 9001. SINCLAIR products comply with European standards, which guarantee safe operation.

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N SINCLAIR represents high standard of quality, great performance with modern design. SINCLAIR SDV III commercial system provides complex solution for air conditioning of entire buildings. Wide range of capacities and models of indoor units enable countless combinations which will meet any of your needs. SDV III model line uses only environmentally friendly, CFC free refrigerant R-410A which prevents ozone layer depletion by CFCs. This refrigerant also improves energy effi ciency.

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III PRODUCT EXPLODED VIEW SMALLER PRESSURE LOSS, LOWER NOISE The grill of fan air inlet and fan air outlet have airfl ow direction adjusting function, which leads to lower pressure loss. BIGGER AIRFLOW VOLUME, LOWER NOISE Adopt dual turbofan which make bigger airfl ow volume with lower noise. RELIABLE ELECTRIC CONTROL PCB Benefi t from digital scroll compressor, no need to apply complex inverter module to achieve variable capacity output. More simple and reliable, no electromagnetic interference. NEW TYPE HIGH EFFICIENT HEAT EXCHANGER Adopt 3-row inner-screw copper heat-exchanger, which creates higher heat transfer effi ciency and powerful heating capacity especially in low ambient temperature. PATENTED DESIGN, RUNNING RELIABLE Gas balance: balancing the refrigerant suction volume among different compressors. 4

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N ELEGANT APPEARANCE, LONGEVITY OF USAGE Achieving advanced technical process, which gets elegant appearance with longevity of usage. CREATIVE DESIGN, PRECISE REFRIGERANT CONTROL Double electrical expansion valve, which achieves up to 960 steps refrigerant adjusting precision to get the best refrigerant distribution effect. CLASSIC DESING, PRECISELY CONTROL HEAT-EXCHANGER AREA The area of outdoor heat-exchanger can be precisely adjusted. POWERFUL REFRIGERANT SYSTEM CONFIGURATION ADOPT DIGITAL SCROLL COMPRESSOR. Compressor with wide running arrangement, multi compressors can be parallely connected, the corresponding capacity range can achieve 2.5%-100% (when 4 models assembled to 64 HP) RESERVING SPECIAL-DESINGED TRANSPORTATION POSITION FOR FORKLIFT Making easy installation for the sling movement. 5

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III FULL RANGE OF R410A DIGITAL SCROLL A/C SYSTEM FEATURE OF R410A SYSTEM Friendly Refrigerant, save energy and protect environment. Good performance of cooling and heating. The component of the R410A is close to azeotropy, with little change of the component structure, the capability will not decrease during the recharge period. Does not contain the element Chlorine, protects the ozonosphere. R410A BASIC MODULES 5 basic modules: 8HP, 10HP, 12HP, 14HP, 16HP 2HP increments of capacity HIGH EFFICIENCY, THE EER IS UP TO 3.45 Basic modules FREE COMBINATION, WIDE RANGE 5 basic modules, which can be freely assembled. 2HP increments of capacity range, which meets customers needs accurately. Maximum capacity is 64HP. 50-64 HP 34-48 HP 18-32 HP 8-16 HP 6

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N INTELLIGENT BUILT-IN MANAGER SYSTEM Intelligent Manager is an integrated building management system (BMS) that uses our independent, high-speed multi-transmission method. It has a centralized controller function that can perform high-speed centralized control of our commercial A/C for buildings. SDV III SYSTEM HAS VARIOUS CONTROL SOLUTIONS: Individual control, Group control, Network control, etc. 1 computer can monitor max 16 central controllers. 1 central controller can monitor max 64 indoor units. 1 computer can monitor max 1024 indoor units. BMS *Elevator *Pump *Lighting...etc. Fire alarm Security Power supply facility R LON bus over ethernet Max=32 Lonwork Max=64 Built-in manager system Max= 16 Max=64 Touch controller Central controller Remote controller 7

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III INTELLIGENT BUILT-IN MANAGER SYSTEM INDEPENDENT CALCULATING SYSTEM POWER POWER POWER CCM Max=64 CCM Converter POWER Digital Ammeter Built-in manager system INDEPENDENT CALCULATION REPORT Independent calculation and output with report, easy to know the charge of the A/C. GROUP SETTING, SIMPLE AND EFFICIENT One group consists of on-line A/Cs in different Central controllers, maximum 1024 units. One system can be set by 16 groups to manage a huge A/C system. The group setting can control each on-line unit, unionize them to be On / Off or change the parameters. It s so convenient and easy. SCHEDULE SETTING, NO NEED TO WORRY DURING THE OPERATION OF A/C With the advanced Schedule setting mode, the PC can easily manage the daily work of A/C. The system can set the weekly plan of A/C and operate automatically in cycle. 8

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N MODEL SELECTION SOFTWARE WINDOWS VERSION Operate directly on Windows interface Friendlier itnerface makes its applicable range much wider. Main functions includes load calculation, multisplit and chilled water system selection, explicit quotation table output, hydraulic calculation, capacity inquire with changeable outdoor environment (for multi-split) or nonstandard working criteria (for chiller), etc. Update with product change. SDV III CAD VERSION The version is compatible with AutoCAD 2004/2005. Professional software that helps engineers design project easily, quickly and conveniently. Main functions include load calculation, equipment selection, pipeline setting, system fi gure confi guration, quotation table automatic output, refrigerant volume calculation, wiring and installation diagram output, etc. Update with product change. 9

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III FEATURES OF DIGITAL SCROLL COMPRESSOR COPELAND Extended energy adjustment range: 10% - 100%. Real stepless energy adjustment. Long life-time: PWM solenoid valve can be used 40 billion times on average, which is equal to 30 years life. High effi ciency and stability of the refrigerant compressed by applying the axial compliant sealing technology. Illustration of real scroll compressor cross-section of unit Operation principle of digital scroll compressor PWM Valve Discharge Fixed Scroll Suction Orbiting Scroll DIGITAL SCROLL COMPRESSOR COPELAND 10

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N OPERATION PRINCIPLE OF DIGITAL SCROLL COMPRESSOR Biasing chamber Discharge pressure Single 2-way solenoid valve (open) Bleed hole The digital scroll compressor which utilizes the axial compliant sealing technology precisely adjusts the axial moving range of the stator scroll pan. And there is an additional connecting bypass between the suction inlet and the pressure bore at the fl oating sealing point of axial stator. When PWM solenoid valve is open, the pressure in the pressure bore is released. The pressure in the compression bore is higher than that top of the stator, then the stator axis of the compressor will move upward a little. So high pressure bore and low pressure inlet is connected and the unloading is achieved. When PWM solenoid valve is closed, two stators are engage. Then the airproof and loading is achieved. The compressor can adjust the ratio of ONs to OFFs freely to control the refrigerant output from the compressor. Biasing chamber UNLOADING Discharge pressure Suction pressure Single 2-way solenoid valve (closed) Bleed hole Suction pressure LOADING CONTROL PRINCIPLE OF VARIABLE CAPACITY SYSTEM Periodical load and unload of the compressor can control refrigerant volume. One unloading and one loading are called one control cycle. Generally one control cycle takes 10 to 20 seconds. The control of the ratio of the unloading and loading time can achieve different output of refrigerant. THE SCHEMATIC DIAGRAMS OF 10%, 50% AND 100% OF THE FULL CAPACITY Example: suppose full capacity is 10HP, and control cycle is 20 seconds. If output needs 5HP (50% of the full capacity), then loading time account for 50% of the total time. That is, 10 seconds respectively for both loading time and unioading time. If you need to output 2HP (20% of the full capacity), then the load time will take up 20% of the total time, that is, 4 seconds for loading and 16 seconds for unioading. This formula applies to other numbers. 100% Output capacity 50% Output capacity 10% Output capacity 20 second cycles 20 second cycle 20 second cycle 11

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III OUTDOOR UNIT Capacity (HP) Model Combination (HP) Indoor unit 4 SDV-120EA 4 6 6 SDV-140EA 6 8 8 SDV-252EA 8 13 10 SDV-280EA 10 16 12 SDV-335EA 12 16 14 SDV-400EA 14 16 16 SDV-450EA 16 20 18 SDV-532EA 8+10 20 20 SDV-560EA 10+10 20 22 SDV-615EA 10+12 20 24 SDV-680EA 10+14 20 26 SDV-730EA 10+16 20 28 SDV-785EA 12+16 20 30 SDV-850EA 14+16 32 32 SDV-900EA 16+16 32 34 SDV-960EA 10x2+14 32 36 SDV-1010EA 10x2+16 32 38 SDV-1065EA 10+12+16 32 40 SDV-1130EA 10+14+16 40 42 SDV-1180EA 10+16x2 40 44 SDV-1235EA 12+16x2 40 46 SDV-1300EA 14+16x2 40 48 SDV-1350EA 16x3 40 50 SDV-1405EA 12x3+14 50 52 SDV-1455EA 12x3+16 50 54 SDV-1520EA 12x2+14+16 50 56 SDV-1570EA 12x2+16x2 50 58 SDV-1630EA 10+16x3 50 60 SDV-1685EA 12+16x3 64 62 SDV-1750EA 14+16x3 64 64 SDV-1800EA 16x4 64 Model SDV- 120EA 140EA 252EA 280EA 335EA 400EA 450EA Capacity Cooling kw 12 14 25,2 28 33,5 40 45 Heating kw 14 16 27 31,5 35 43 47 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance 220-240, 50, 1 380-400, 50, 3 Air Flow Volume m 3 6000 6000 11500 14800 Noise Level db(a) 55 55 58 60 Dimension Net W H D mm 940x1245x340 940x1245x340 980x1630x800 1380x1630x830 Packing W H D mm 1058x1300x435 1058x1300x435 1040x1780x840 1440x1800x860 Weight Net kg 112 117 245 382 Gross kg 125 126 260 400 Piping Connection Max Lenght of pipe 50 70 175 Max Height Difference Between indoor units Between indoor units and outdoor unit 8 15 20 70 Remarks: 1. The above speciffi cations are subject to change without prior notice for product improvement. 2. The noise levels given in the table refl ect the levels in anechoic chamber. 3. SDV-120EA and SDV-140EA are not modular. 12

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N INDOOR UNIT FOUR-WAY CASSETTE COMPACT Model SDV- 28CA 36CA 45CA Capacity Cooling kw 2,8 3,6 4,5 Heating kw 3,2 4 5 Electrical Data Voltage, Frequence, Phase V~, Hz, f 220-240,50,1 Performance Air Flow Volume m 3 780 Noise Level db(a) 36 Dimension Net W H D mm 580x254x580 Panel W H D mm 650x30x650 Packing W H D mm 795x340x745 Panel W H D mm 715x115x715 Weight Net kg 22/3 Gross kg 29/5 FOUR-WAY CASSETTE Model SDV- 54C4A 71C4A 80C4A 90C4A 112C4A Capacity Cooling kw 5,6 7,1 8 9 11,2 Heating kw 6,3 8 9 10 12,5 Electrical Data Voltage, Frequence, Phase V~, Hz, f 220-240,50,1 Performance Air Flow Volume m 3 1050 1600 Noise Level db(a) 38 42 44 Dimension Net W H D mm 840x240x840 840x310x840 Panel W H D mm 950x40x950 Packing W H D mm 955x255x955 955x325x955 Panel W H D mm 1030x145x1030 Weight Net kg 28/6 35/6 Gross kg 34/11 41/11 DUCT Model SDV- 22DA 28DA 36DA 45DA 56DA 71DA 80DA 90DA 112DA 140DA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 7,1 8 9 11,2 14 Heating kw 2,6 3,2 4 5 6,3 8 9 10 12,5 16 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance 220-240,50,1 Air Flow Volume m 3 750 1160 1460 2070 2400 External static pressure 40 Noise Level db(a) 34 35 38 42 44 46 Dimension Net W H D mm 800x320x550 1000x298x800 1350x298x800 Packing W H D mm 930x420x755 1200x370x930 1555x370x930 Weight Net kg 26 46 47 60 Gross kg 34 54 55 70 13

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III INDOOR UNIT FLOOR STANDING Model SDV- 22FSA 28FSA 36FSA 45FSA 56FSA 71FSA 80FSA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 7,1 8 Heating kw 2,6 3,2 4 5 6,3 8 9 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance 220-240,50,1 Air Flow Volume m 3 420 490 620 850 950 1050 Noise Level db(a) 35 37 39 40 42 Dimension Net W H D mm 1000x626x220 1200x626x220 1500x626x220 Packing W H D mm 1145x810x285 1335x810x285 1645x810x285 Weight Net kg 38 43 55 Gross kg 42 47 60 CEILING & FLOOR Model SDV- 36FA 45FA 56FA 71FA 80FA 90FA 112FA Capacity Cooling kw 3,6 4,5 5,6 7,1 8 9 11,2 Heating kw 4 5 6,3 8 9 10 12,5 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance 220-240,50,1 Air Flow Volume m 3 800 1000 1200 1400 1800 Noise Level db(a) 36 38 40 41 42 Dimension Net W H D mm 995x660x198 1285x660x198 1670x680x240 Packing W H D mm 1080x740x290 1365x740x290 1760x760x330 Weight Net kg 30 34 52 Gross kg 37 42 62 WALL-MOUNTED Model SDV 22HA 28HA 36HA 45HA 56HA Capacity Cooling kw 2,2 2,8 3,6 4,5 5,6 Heating kw 2,5 3,2 4 5 6,3 Electrical Data Voltage, Frequence, Phase V~, Hz, f Performance 220-240,50,1 Air Flow Volume m 3 580 850 Noise Level db(a) 34 37 Dimension Net W H D mm 790x265x195 920x292x225 Packing W H D mm 875x375x285 1015x368x295 Weight Net kg 9 13 Gross kg 11 15 14

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N CONTROLLERS DESCRIPTION Remote Controller (Standard) Wire Controller (Optional) Wire Controller (Optional) Central Control Monitor (Optional) Central Control Monitor (Optional) Touch Controller (Optional) R51, R05/BG KJR-01B KJR-10B, KJR-12B CCM04 Suitable for SDV III system Suitable for SDV III system KJR-10B New design KJR-12B New design with function FOLLOW ME CCM04 Weekly timer MODEL CCM01 FUNCTION Control 64 indoor units simultaneously at most (suitable for SDV III system) CCM02 CCM10 CCM02 Control 32 outdoor units simultaneously at most (suitable for SDV III system). CCM10 New design with lock heating or cooling. TCM01 Suitable for Intelligent built-in manager system SET BUTTON Enter into the setting screen. MODE BUTTON Choose the mode. CENTRAL CONTROLLER QUERY BUTTON Check the running status of the A/C. TIMER BUTTON Set the current time and off time. SWING BUTTON With or without swing. OK BUTTON Confirm the operation. OPERATION INDICATOR Lights when the unit is in operation. ON/OFF BUTTON Start or stop operation. FAN SPEED BUTTON Adjust fan speed. PREVIOUS OR NEXT BUTTON In query or set mode, Transfer between previous and next unit. DATAS OR PAGES ADJUST BUTTON Adjust the datas or pages. RESET BUTTON Reset current unit to the default setting. LOCK BUTTON Lock or unlock current A/C status. AUXILIARY HEATER BUTTON Start or sto p the electrical auxiliary heater ON/OFF BUTTON Start or stop operation. WIRE CONTROLLER FOLLOW ME BUTTON Adjust the action of indoor unit according to the Temp. sensor inside the wire controller TIMER BUTTON Timer setting. OK BUTTON Confirm the operation RESET BUTTON Reset all the setting and get in to the condition of beginning. MODE BUTTON Choose the mode. ECONOMY BUTTON Start or stop economical mode TEMP. BUTTON Preset temperature. SWING BUTTON With or without swing. FAN SPEED BUTTON Choose fan speed. LOCK BUTTON Lock or unlock all current setting. 15

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III DISTRIBUTOR REFRIGERANT DISTRIBUTOR DIMENSION CHART The connecting point can be freely adjusted to meet different pipes. Adoption of international standard measurement assures easy replacement. SDV-BY51N1 Gas side SDV-BY101N1 Gas side Liquid side Liquid side SDV-BY102A Gas side SDV-BY103A Gas side Liquid side Liquid side 16

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N SDV-BY104 Gas side SDV-BY105 Gas side Liquid side Liquid side THE DIMENSION OF Y-SHAPE THREE-WAY PIPE. SDV-DY01 Gas side SDV-DY02 Gas side Liquid side Liquid side 17

C O M M E R C I A L S D V I I I A I R C O N D I T I O N E R S SDV III SEE YOU IN THE WORLD OF AIR CONDITIONERS

M O D U L A R D E S I G N & F L E X I B L E C O M B I N A T I O N AIR CONDITIONERS represent a modern, reliable and effective solution how to create a pleasant conditions for satisfi ed living of people.

Internet: http://www.sinclair-eu.com E-mail: info@sinclair-eu.com COMMERCIAL AIR CONDITIONERS