HP 2 SERIES Integral Driver - Solid State LED

Similar documents
REGATTA PATH LIGHT (RGP)

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

10. Do not install within 10 feet of a pool, spa, or fountain. 4. Keep lamp away from materials that may burn.

Installation Instructions

INSTALLATION INSTRUCTIONS for DALTON LED SERIES

IMPORTANT LISTINGS AND CERTIFICATIONS. Suitable for wet locations Additionally suitable for mounting within 4 ft. of the ground

Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Direct Burial Floodlight - DBF Installation Instructions Above Grade Housing

Installation and Assembly: Flat Video Wall Mount For 40" to 65" Flat Panel Displays

Tube Facing Tool.

General Installation Instructions LED

AUC Cell Assembly Torque Stand. User Manual

CHEMINSTRUMENTS LABORATORY DRAWDOWN COATER LC-100 OPERATING INSTRUCTION

GLASS GLOBE MOBILE LINEAR CHANDELIER

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

ClearSpan PolyMax Windbreak Wall

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Assembly Instructions for model: VMPR1

SINCE 1922 P UBLICATION N O

Flat Panel Stand FPZ-655. for 32" to 55" Flat Panel Screens FEATURES. Reinforced universal adapter plate for a strong hold

WARNINGS & SAFETY INFORMATION: PLEASE READ CAREFULLY AND KEEP A COPY ON THE PROPERTY FOR FUTURE REFERENCE!

Maintenance Information

Installation Instructions

MPA-9000 Universal Ceiling Projector Mount Kit

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

MODULAR LED UNDERCABINET LIGHTING SYSTEM Max 540watts IMPORTANT SAFETY INSTRUCTIONS

1904, 1904Pg, 1904PgSB, and 1906SB High Capacity Ratchet Knockout Drivers

MODEL H " BYRD SHELIX CUTTERHEAD INSTRUCTIONS

Installation and Assembly: Full Service Video Wall Mount

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

Kawasaki Teryx 750 Cab Kit* Caution: Before using this product, read this manual and follow all Safety Instructions.

GLASS GLOBE MOBILE 6-ARM CHANDELIER

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

Frameless Hinged Door Enclosure. These instructions must be left with the user. Installation Guide W2-B

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

Lowlighter KLV Volt Die-Cast Brass, MR16 Halogen revision 2/25/14 kl_klv275_spec.pdf. Ravenna TM. Specifications. Approvals: Type: Job:

Spun Copper Bullet C to 277 Volt Spun Copper LED revision 11/7/14 kl_c24led_spec.pdf

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

101B, 210X, ELM, VSTB Installation Manual

Curium 19H Installation Instructions & Parts List

Elcometer Muller Laboratory Grinder

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Gallium 03 Installation Instructions & Parts List

Curium 19.4H Installation Instructions & Parts List

Inventory (Figure 2)

Assembly Instructions for Model: VMPR1

FORD MOUNT INSTALLATION INSTRUCTIONS


Allegro Home Office Assembly Instructions. Tipping Restraint. Bun Foot W/ Leveler. 4 pcs.

MODEL T " SPIRAL CUTTERHEAD INSTRUCTIONS

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

Auto-Spreader Spreader HS10K Hydraulic Flange Spreader

INFINITE RANGE - CENTRE FOLDING DOOR

Installation Manual Flat Track Series

FACTORY STRETCH INSTALLATION INSTRUCTIONS

Dubnium 11 Installation Instructions & Parts List

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents

Assembly Instructions

Shower Screen and Door Kit Instructions

Kiosk Solution W1000. Installation and Assembly Instructions July 2015 Edition

INSTRUCTION SHEET STRUT DRIVER RETROFIT KIT PN: 22-79SDRF

INSTALLATION LED DRIVER. Top view. LED Module. Barrel. Block side. 2 black or white wires. 2 red wires. Gland. + side. Cover. Mounting Screws.

RPMSP Series Installation Guide

MaxLite Linear Strip ECO Series

Heavy Duty Ceiling Tilt Mount Installation Manual

H2-50 Hydrogen Generator Field Update

RPS /02 Effective for models with serial numbers beginning with "G".

Wall mounting bracket

General Installation Instructions

Installing flat panels on the MPL15 wall mount

Tapping Screw (W/Flange) 46 Cord Armor 47 Tube (D) 48 Cord. 45 Cord Clip. Tapping Screw (W/Flange) 10 Gear Cover Ass'y. 12 Socket (B) Ass'y

INFINITE RANGE - HINGE DOOR

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Midmark Care Exchange 6282 Standard Duty Wall Mounted Workstation

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

MODEL W1.0X305A(12 ) MODEL W1.0X610A(24 ) HAND BENDING BRAKE ASSEMBLY&OPERATING INSTRUCTION

SMALL GAUGE NIBBLER ASSEMBLY & OPERATING INSTRUCTIONS Mission Oaks Blvd., Camarillo, CA Visit our Web Site at

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

VERSA-COM BOX; TURF VERSION WITH INFILL RETAINMENT BRUSHES ASSEMBLY INSTRUCTIONS

ENIGMA AIR ENCLOSURE

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

INSTALLATION INSTRUCTIONS REPLACING EXISTING DEADBOLT ASSEMBLY

INSTALLATION INSTRUCTIONS Small Flat Panel Mounts Model: F-Series

Tools & Materials Needed

Installation Instructions for Vista Air Vertically Folding Walls

SolidStep 3.0 OEM INSTALLATION MANUAL

Installation and Assembly: Ceiling mount for LCD screens up to 29"

Pathway Stair System For use with the Pathway Modular Ramp System, as freestanding stair, or with other structures.

Self-assembly and pole conversion system

Preference Collection 5580 Treatment Console INSTALLATION GUIDE

Radon 07 Installation Instructions & Parts List

Pole Conversion System For safe and efficient conversion of non-lowering light poles.

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Transcription:

HP 2 SERIES Installation Instructions Warning High Voltage Hot Surface NEEDED FOR INSTALLATION: By Others 1/8 & 5/32 Allen Wrench Waterproof Wire Connectors Level Phillips Screwdriver IMPORTANT - WEAR GLOVES TO AVOID GETTING FINGERPRINTS ON THIS PRODUCT. MANY TEKA ILLUMINATION PRODUCTS ARE DESIGNED TO NATURALLY PATINA. OILS FROM YOUR SKIN WILL ACCELERATE THIS PROCESS WHERE TOUCHED AND ARE NEARLY IMPOSSIBLE TO REMOVE. THIS PROCESS OCCURS OVER TIME AND IS DETERMINED BY THE INSTALLATION ENVIRONMENT. INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS: Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use a soft cloth or gloves. Oil from skin may cause damage. SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes. Follow product label information and instructions. Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product. Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis. Entire fixture may become extremely hot. Do not touch hot lens or fixture body. Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly. All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an IMPORTANT LISTINGS AND CERTIFICATIONS Suitable for wet locations Specify Fixture Separately Soil Prep Silicone O Ring Conduit trench 18 Dia. Faceplate Concrete Pour Collar Quick Disconnect A. Determine Soil Type by referencing DIG-IT Guide. B. Dig hole 18 wide and 20 deep. Driver Tray Patented Stability Flange Excavated for Housing Patented HydroLock Plate Waterproof Wire Connectors HP2 Housing Conduit Trench C. Prep soil according to DIG-IT Guide. THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION, INC. IS STRICTLY FORBIDDEN.

Installation Instructions PROJECT: HP 2 SERIES TYPE: Housing Installation Side Flats Threaded Entry 1. Connect branch conduit connectors (By Others) to the junction box using either the threaded conduit entries on the bottom of the junction box or through holes drilled into the sides of the junction box. 2. Place housing in hole. Align junction box in the path of the conduit trench. 3. Insert (4) pieces of ½ EMT conduit through the Stability Flange. Hammer into substrate until secure. Leave sufficient clearance to elevate housing to finished grade. Flush with finished grade 4. Raise housing on EMT so concrete pour collar is flush with finished grade. Use a level to aid in housing installation. 5. When housing is level, tighten screws on Stability Flange to secure housing to EMT. Remove excess EMT as needed. 6. Connect the conduit to the conduit connectors. 7. Per DIG-IT Guide, backfill the gap between the bottom of housing and bottom of hole with sand for drainage. 8. For soil installation: Fill and tamp soil to the appropriate height leaving room for sod, pavers, etc. to be level with the top of the temporary cover. 9. For concrete installation: Fill the hole around the fixture housing to 12 below the finished grade with clean fill dirt and tamp carefully to prevent settling of fixture. Pour concrete and finish as required flush with the top surface of the temporary cover.

Installation Instructions PROJECT: HP 2 SERIES TYPE: Installation LINE LINE GROUND GROUND HYDRO-LOCK PLATE COM COM 1. Remove temporary cover. 2. Pull primary branch circuit wiring and dimmer wiring into junction box. 3. Make connections using silicone filled wire nuts (provided) to leads on the bottom of Patented HydroLock Barrier Plate Assembly. See wiring diagram. WIRING DIAGRAM 4. Wipe inside of housing where HydroLock plate will sit clean of debris before inserting patented HydroLock plate on to junction box. Align HydroLock plate with pins in housing and seat it firmly in place. 5. Turn HydroLock Barrier Plate clockwise ¼ to lock. Patented HydroLock Barrier Plate must be completely seated to ensure proper seal or water may intrude. This step must be done as stated or you will void your warranty. 6. Connect driver assembly to Patented HydroLock Barrier plate with quick disconnect. 7. Lower driver assembly into HP2 housing. 8. Attach driver assembly to housing by aligning keyhole notch under one (1) of three (3) #8 screw heads. 9. Tighten the Phillips screws to secure driver plate to housing.

Installation Instructions PROJECT: HP 2 SERIES TYPE: 10. Remove any dirt or debris in O-ring groove near top of housing. Place O-Ring inside of groove. Failure to clean groove of debris will cause fixture to fail and void product warranty. 11. Attach fixture to installed driver assembly with quick disconnect. 12. Install faceplate using 1/8 Allen wrench and hand-tighten the faceplate screws in a star pattern to 30 in-lbs. min. Do not use a power tool to install screws. Do not exceed 40 in-lbs.

LIBERTY FLOODLIGHT (LBF) NEEDED FOR INSTALLATION: 5/32 Allen Wrench Waterproof Wire Connectors Gloves Warning Hot Surface Wear Gloves Low Voltage By Others IMPORTANT - WEAR GLOVES TO AVOID GETTING FINGERPRINTS ON THIS PRODUCT. MANY TEKA ILLUMINATION PRODUCTS ARE DESIGNED TO NATURALLY PATINA. OILS FROM YOUR SKIN WILL ACCELERATE THIS PROCESS WHERE TOUCHED AND ARE NEARLY IMPOSSIBLE TO REMOVE. THIS PROCESS OCCURS OVER TIME AND IS DETERMINED BY THE INSTALLATION ENVIRONMENT. INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS IMPORTANT SAFETY INSTRUCTIONS Lighted fixture is HOT! WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS: Turn off/unplug and allow to cool before replacing LED. Fixture gets HOT quickly! Contact only switch/plug when turning on. Do not touch hot lens, guard, or enclosure. Keep fixture away from materials that may burn. Do not operate the luminaire fitting with a missing or damaged shield. Do not touch the source at any time. Use a soft cloth or gloves. Oil from skin may cause damage. SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code, Canadian Electrical Code, and all Local and Provincial Codes. Follow product label information and instructions. Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product. Before wiring to power supply and during servicing, turn off and lock out power at fuse or circuit breaker before service. The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. The use of damaged components may cause an Do not block light emanating from product in whole or part, as this may cause an unsafe condition. Never operate the fixture with missing or damaged lens. Lens must be cleaned on regular basis. Entire fixture may become extremely hot. Do not touch hot lens or fixture body. Replace LED assembly only with correct wattage and type of power supply appropriate for LED assembly. All gaskets, o-rings and sealing surfaces must be kept clean during installation and service; failure to do this may cause an IMPORTANT LISTINGS AND CERTIFICATIONS Suitable for wet locations REMOTE WIRING LED Driver Remote driver installations require inter-connected wiring between the LED and driver (by others). Drivers have specific wiring requirements between these components. Driver manufacturers regularly recommend the following wiring details for such installations: Lens Do not exceed 50 foot overall wiring distance using 12 gauge copper wire. Failure to comply with specific wiring requirements will void product warranty. Housing Hinged Clamp Rings Swivel Lock Aiming Adjustment Screw Heavy Wall Stem Locknut 8-14-17 INS-2615-00 THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF TEKA ILLUMINATION AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY DESCRIBE. REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF TEKA ILLUMINATION IS STRICTLY FORBIDDEN.

LIBERTY FLOODLIGHT (LBF) Standard Fixture Installation Must install to a suitable enclosure. LINE Remote + Driver LED COM - 1. Mount fixture onto suitable enclosure according to designed lighting plan. Use locknut to secure. WIRING DIAGRAM 2. Make watertight connections from remote driver to fixture leads using waterproof wire connectors (By Others). See wiring diagram. Aiming 1. To aim vertically, loosen the lamp head adjustment screw using a 5/32 Allen wrench, adjust as needed, then secure aiming position by tightening lamp head adjustment screw. Do not rotate more than 360 degrees to avoid wire damage. 2. To aim horizontally, loosen two (2) #8-32 set screws using 5/64 Allen wrench. Adjust horizontal aim, then secure aiming position by tightening set screws. Do not rotate more than 360 degrees to avoid wire damage. 8-14-17 INS-2615-00

LIBERTY FLOODLIGHT (LBF) This product is available with field replaceable components. Exclusive interchangeable OPTIKITS and modular LED components with quick disconnects simplifies upgrades and maintenance when necessary. 1. Loosen two (2) captive screws on stainless steel clamp rings using 5/32 Allen wrench until the screws disengage from back plate. 2. Swing lens assembly open. 3. Remove optic by pulling gently and lift up. 4. Use.050 Allen wrench to loosen three (3) set screws holding optic holder and LED module. 5. Gently lift LED module and disconnect from fixture. Install new LED module. Secure set screws through LED module and optic holder using.050 Allen wrench. Do not pull on connector or wiring. Handle with care. 6. Replace optic by lining tabs with optic holder, then pressing down gently until secured into place. 7. Close swing assembly. 8. Tighten two (2) captive screws on stainless steel clamp rings using 5/32 Allen wrench. Do not overtighten. 8-14-17 INS-2615-00