2A (recommended) Power loss

Similar documents
Product type designation. General information. Supply voltage

General information. Supply voltage

Data sheet CPU 313SC (313-5BF13)

6ES7314-6BH04-0AB0. STEP7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 314ST/DPM (314-6CF02)

Data sheet VIPA CPU 314SC DPM (314-6CG23)

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

CPU 314C-2 PTP. Function

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

Programming restrictions when operating SM 331; AI 8 x RTD with PROFIBUS masters which only support DPV0.

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

General specifications and features

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

General information. CiR - Configuration in RUN

FM 355 CONTROLLER MODULE

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current

General information. CiR - Configuration in RUN

Product Information. Release 3 4 SIMATIC ET 200S. 4DI UC V High Feature Digital Electronic Module

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

Zentralbaugruppen CPU 222

6.6 Analog input module SM 331; AI 8 x 13 Bit; (6ES7331-1KF02-0AB0)

Q.raxx A slimline RS / EC Universal Measurement System

FM HIGH-SPEED BOOLEAN PROCESSOR

FM COUNTER MODULE

DEA 115, Digital Input/Output Modules

SIPLUS SM 1234 ANALOG INPUT/OUTPUT MODULE

Q.raxx A slimline RS / EC

PLC-K506 Series FEATURES DESCRIPTION FEATURES

Q.raxx A101-8 slimline RS / EC

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

Order number 031-1BB BB BB BD30 Figure. SM 031, AI 2x12Bit I. Note - - Coming soon - Features. 2 inputs, Current 0(4)...

SIMATIC S7-300 Function modules

SIMATIC. ET 200S distributed I/O 2AI U HS analog electronic module (6ES7134-4FB52-0AB0) Preface. Properties 1. Parameters 2.

FM COUNTER MODULE

EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) SIMATIC. ET 200SP Analog input module AI 8xU BA (6ES7134-6FF00-0AA1) Preface. Documentation guide 1

Manual. VIPA System 100V EM - Expansion modules 134-4Ex. Order No.: VIPA HB100E_EM Reference: RE_134-4Ex Rev. 08/23

8V General information. 2 Order data 8V

AIO and DIO PFXLM4B01DAK:Sink Output Type PFXLM401DAC:Source Output Type Virtual Resolution (pixels)

8V General information. 2 Order data 8V

PFXLM4B01 D * * (1) (2) (3) (4)

SIMATIC S5. ET 100U Distributed I/Os. Manual. EWA 4NEB a

8558A 8 1/2 Digit Multimeter

S7-200 SMART Programmable controller Answers for industry.

SIMATIC. ET 200S distributed I/O Analog electronic module 4AI TC ST (6ES7134-4JD00-0AB0) Preface. Properties 1. Parameters 2.

Highlights Very compact EtherCAT I/O system in IP 20 for plug-in into a circuit board (signal distribution board)

S11 Adjustable Speed Drive Engineering Specification

K3P ENG.qxd 23/10/ Pagina 1

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Remote I/O. 74 Remote I/O. Remote I/O System

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

em4 em4 alert em4 alert 2G

em4 local - Robust Specific characteristics Part number

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

EXM INPUT/OUTPUT EXPANSION

Analog input module. AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1) SIMATIC. ET 200SP Analog input module AI 2xU/I 2-/4-wire HF (6ES7134-6HB00-0CA1)

Type CP-S, CP-C & CP-A Switch mode

Analog Input Module. AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0) SIMATIC. S7-1500/ET 200MP Analog Input Module AI 4xU/I/RTD/TC ST (6ES7531-7QD00-0AB0)

UniStream 5" Technical Specifications US5-B5-RA28, US5-B10-RA28

CPU. BM40, BM40PB, BM40IE Industrial amplifier. Special features. Data sheet. Block diagram

S200 I/O System Units

Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) SIMATIC. ET 200SP Analog input module AI 2xI 2/4-wire ST (6ES7134-6GB00-0BA1) Preface

EY-EM 522, 523: Remote I/O module, ecolink522, 523

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

EY-EM 527: Remote I/O module, ecolink527

Analog electronic module SIMATIC. ET 200S distributed I/O Analog electronic module 2AI TC ST (6ES7134-4JB01-0AB0) Preface. Properties.

XIOC technology and networking modules

Chapter 6 Specifications

8588A Reference Multimeter

UniStream Built-in. Technical Specifications US7-B5-RA28, US7-B10-RA28 US7-B5-TA30, US7-B10-TA30

Technical Reference IMI B001 4 Channel 400 Point Modular Parison Controller MOOG

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

SIMATIC. ET 200SP HA Analog input module AI 16xTC/ 8xRTD 2-/3-/4-wire HA (6DL1134-6JH00-0PH1) Security information 1. Product overview 2.

NI REM Remote I/O Overview DATASHEET. Temperature Input Module for Remote I/O

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

SIMATIC. ET 200SP Analog Input Module AI 4xU/I 2-wire ST (6ES7134-6HD01-0BA1) Preface. Documentation guide. Product overview.

FM POSITIONING MODULE

FM COUNTER MODULE

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

20 General technical data XI/ON

CHAPTER 8 PHOTOMULTIPLIER TUBE MODULES

PHOENIX CONTACT - 03/2007

Technical Data: Model:EXM-12DC-DAI-R

MULTIFUNCTION GRAPHICAL UNIT MGU 800

- Continuous real-time measurement and PD trend analysis; not multiplexed data collection.

Technical data: Instabus EIB supply Voltage: YY 6 x 0.6 mm; red: bus (+) / black: bus (-)

VersaPoint I/O Module

SIMATIC. ET 200SP Analog Input Module AI 4xI 2-/4-wire ST (6ES7134-6GD01-0BA1) Preface. Documentation guide. Product overview.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Technical Data: Model:EXM-12DC-DA-R-4G

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Magnetic absolute encoder GEL 2035 Serial interface (SSI), 24 Bit

150Hz to 1MHz magnetic field coupling to a typical shielded cable above a ground plane configuration

Transcription:

Technical Data CPU 314SC/DPM Module name Dimensions and weight Dimensions W x H x D 120 x 125 x 120mm Weight 610g Voltages, Currents, Potentials Power supply (rated value) DC 24V - Permitted range 20.4... 28.8V - Reverse polarity protection Current consumption (-load operation) 350mA Inrush current typ. 11A Power consumption (minal value) 1A I 2 t 0.7A 2 s External fusing of power supply lines 2A (recommended) Power loss 14W Accumulator Lithium - Clock back-up period 30 days Memory Work memory - integrated 128kByte - expandable up to 1MByte Processing times Processing times for - Bit instructions 0.011μs - Word instructions 0.011μs - Double integer arithmetic 0.011μs - Floating-point arithmetic 0.063μs Timers/Counters and their retentive characteristics S7 counters 512 - Retentivity adjustable - Preset up C0 to C7 - Counting value 0 up to 999 IEC counters - Type SFB - Number unlimited (limited only by RAM size) S7 timers 512 - Retentivity adjustable - Preset t retentive - Time range 10ms to 9990s ICE timers - Type SFB - Number unlimited (limited only by RAM size) Data areas and their retentive characteristics Bit memories 8192Byte - Adjustable retentivity adjustable - Preset MB0 to MB15 Clock memories 8 (1 flag byte) Data blocks max. 4095 - Size 64kByte Local data - per priority class 510Byte 3-10 HB140E - CPU SC - RE_ - Rev. 07/45

Chapter 3 Hardware description Module name Blocks OBs see the instruction list - Size 64kByte Nesting dept - per priority class 8 - additional levels within an error OB 4 FBs 2048 - Size 64kByte FCs 2048 - Size 64kByte Address areas (I/O) Total address areas 1024Byte/1024Byte I/O Process image 128Byte/128Byte Digital channels 7856/7904 - centralized 979/986 - integrated channels 24DI/16DO (32DI/24DO) Analog channels 494/495 - centralized 253/250 - integrated channels 4+1AI/2AO Configuration Number of racks max. 4 Modules per rack max. 8; max. 7 in rack 3 Number of integral DP masters 1 Time Real-time clock (HW clock) - Backed-up - buffered period 6 Weeks - Accuracy Deviation per day < 10s Operating hours counter 1 - Number 0 - Value range 2 15 - Selectivity 1hour - Retentive, must be manually restarted after every restart Testing and commissioning functions Status/Modify Variables - Variable E, A, M, DB, T, Z - Number of variables 30 of those as status variable 30 of those as control variable 14 Force - Variable I, O - Number of Variables 10 Block status Single step Break points 3 Diagstic buffer - Number of entries (t configurable) 100 HB140E - CPU SC - RE_ - Rev. 07/45 3-11

Module name Communication functions PG/OP communication Global Data communication - Number of GD circuit 4 - Number of GD circuit 4 Sending stations 4 Receiving stations 4 - Length of GD packets 22Byte S7 basic communication - User data per job 76Byte consistent data 76Byte (for X_SEND or X_RCV) 64Byte (for X-PUT or X_GET as the Server) Interfaces Hardware description 1. interface Physics RS 485 electrically isolated Interface power supply (15 up to 30V DC) 200mA Functionality 1. interface MPI Profibus DP Point-to-Point connection MPI 1. interface Services - PG-/OP communication - Global data communication - S7 basis communication - S7 Communication as Server as Client - Transmission rates 187.5kbit/s Hardware description 2. interface Physics RS 485 Electrically isolated Interface power supply (15 up to 30V DC) 200mA Functionality 2. interface MPI Profibus DP Point-to-Point connection - Transmission rate half duplex max. 115.2kbit/s - Protocols - ASCII - STX/ETX - 3964(R) - USS - Modbus Master Hardware description 3. interface Physics RJ 45 Functionality 3. interface Profinet Ethernet Services - PG/OP communication 3-12 HB140E - CPU SC - RE_ - Rev. 07/45

Chapter 3 Hardware description Integrated functions Number of counters 4 - Counter frequency max. 60kHz Programming Programming language KOP/FUP/AWL Instruction set see the instruction list Nesting levels 8 System functions (SFC) see the instruction list System function blocks (SFB) see the instruction list User program protection Digital Input Data for specific module Number of inputs 24 Length of cable - unshielded 600m - shielded 1000m Voltages, Currents, Potentials Rated load voltage L+ DC 24V Reverse polarity protection Isolation - between channels and backplane bus - between channels permitted potential difference - between the different circuits DC 75V / AC 60V Isolation tested with DC 500V Current consumption - from the power supply L+ 70mA Status, Interrupts, Diagstics Status display green LED per channel Interrupts ne Diagstic functions ne Data for selecting a Sensor Input voltage - Rated value DC 24V - for Signal "1" 15V to 28.8V - for Signal "0" 0V to 5V Input current - for Signal "1" 6mA Input delay (at minal value of the input voltage range) - Inputs parameterizable 0.13ms-0.43ms Input characteristic curve according to IEC 1131, Type 1 Connection of 2-wire-BEROs - permitted bias current max. 1.5mA HB140E - CPU SC - RE_ - Rev. 07/45 3-13

Digital Output Data for specific module Number of outputs 16 Length of cable - unshielded 600m - shielded 1000m Voltages, Currents, Potentials Rated load voltage L+ DC 24V Reverse polarity protection Total current of the outputs - horizontal configuration up to 40 C 3A - horizontal configuration up to 60 C 2A - vertical configuration up to 40 C 2A Isolation - Between the channels and backplane bus - Between the channels in groups of 8 Permitted potential difference - between the different circuits DC 75V / AC 60V Insulation tested with DC 500V Current consumption - from load voltage L+ 100mA Status, Interrupts, Diagstics Status display green LED per channel Interrupts ne Diagstic functions - Group error display red F-LED per group - supply voltage display green LED per group - Channel error display ne Data for selecting an actuator Output voltage - for Signal "1" min. L+ (-0.8V) Output current - at Signal "1" 0.5A Rated value 5mA to 0.6A - at Signal "0" 0.5mA Load resistor range 48Ω to 4kΩ Lamp load 5W Parallel connection of 2 outputs - for redundant triggering of a load - to increase performance t Actuation of digital input Switch rate - for resistive load 2.5kHz - for inductive load (IEC 947-5 DC 13) 0.5Hz - for lamp load 2.5kHz Limitation (internal) voltage induced on circuit typ. L+ (-52V) interruption at Short-circuit protection of the outputs, electronic - Threshold on typ. 1A 3-14 HB140E - CPU SC - RE_ - Rev. 07/45

Chapter 3 Hardware description Analog Input Data for specific Module Number of inputs 4 channels with current/voltage input 1 channel with Pt100 Length - shielded 200m Programming specifications Input data 10Byte (1Word per channel) Parameter data 13Byte Voltages, Currents, Potentials Resistance input - -load voltage 2.5V - Measuring current up to 3.3mA Isolation - Between channels and backplane bus - Between channels and power supply - Between channels Permitted potential difference - between the inputs (U CM ) DC 8V - between M ANA and M intern (U CM ) DC 75V / AC 60V Insulation tested with DC 500V Analog value generation Measuring principle gradual approximation Integration time-/conversion time/resolution (per Channel) - parameterizable - Basic conversion time 0.5 - Integration time in ms 1.25 16.6 20 - Resolution incl. overrange 12Bit - Noise suppression for frequency f1 in Hz Basic execution time 0.5ms Smoothing of the measured values ne Suppression of interference, Limits of error Noise suppression for f=n x (f1 ±1%) (f1= interference frequency, n=1,2,...) - Common mode interference (U CM < 8V) > 80dB - Series mode ise (peak value of ise < Nominal value of input range) 800 60 50 > 80dB Crosstalk between the inputs > 50dB Optional limit (in the entire temperature range, with reference to the input range) - Voltage input 0...10V ±0.4% ±10V ±0.3% - Current input ±20mA ±0.3% 0...20mA ±0.6% 4...20mA ±0.8% - Resistors 0... 600Ω ±0.4% - Resistance thermometer Pt100 ±0.6% HB140E - CPU SC - RE_ - Rev. 07/45 3-15

Analog Input Basic error (operational limit at 25 C, referred to input range) - Voltage 0...10V ±0.3% ±10V ±0.2% ±20mA ±0.2% - Current 0...20mA ±0.4% 4...20mA ±0.5% - Resistors 0... 600Ω ±0.2% - Resistance thermometer Pt100 ±0.4% Linearity error ±0.05% (with reference to the input range) Linearity error at resistor measurement ±0.2% Temperature error ±0.005%/K (with reference to the input range) Repeatability ±0.05% (in steady state at 25 C, referred to input range) Status, Interrupt, Diagstics Interrupts ne Diagstics functions ne Data for selecting an sensor Input range Input resistance - Voltage ±10V, 0...10V 100kΩ - Current ±20mA, 100Ω 0...20mA, 4...20mA - Resistors 0... 600Ω 10MΩ - Resistance thermometer Pt100 10MΩ Maximum input voltage for voltage input 30V (destruction limit) Maximum input current for current input 50mA (destruction limit) Connection of the sensor - for measuring voltage - for measuring current as 2-wire transmitter, with external power supply as 4-wire transmitter - for measuring resistance as 2-conductor connection as 3-conductor connection t as 4-conductor connection t Characteristic linearization - for RDT Pt100 Temperature compensation Technical unit for temperature measurement C / F / K 3-16 HB140E - CPU SC - RE_ - Rev. 07/45

Chapter 3 Hardware description Analog Output Data for specific Module Number of the outputs 2 Length of cable - shielded 200m Programming data Output data 4Byte (1Word per channel) Parameter data 13Byte Voltages, currents, potentials Load voltage internal via CPU - Reverse polarity protection Isolation - between channels and backplane bus - between channels and power supply of the electronics - between channels Permitted potential difference - between M ANA and M INTERN (U ISO ) DC 75V / AC 60V Insulation tested with DC 500V Analog value generation Resolution - Voltage ±10V 11Bit + Sign 0...10V 11Bit - Current ±20mA 11Bit + Sign 0...20mA, 4...20mA 11Bit Conversion time (per channel) 1ms Settling time - for resistive load 0.5ms - for capacitive load 0.5ms - for inductive load 0.5ms Suppression of interference, Limits of error Crosstalk between outputs > 40dB Operational limit (in the entire temperature range, with reference of the output range) - Voltage 0...10V ±0.4% ±10V ±0.2% - Current ±20mA ±0.3% 0...20mA ±0.6% 4...20mA ±0.8% Basic error (Operational limit, at 25 C, with reference of the output range) - Voltage 0...10V ±0.2% ±10V ±0.1% - Current ±20mA ±0.2% 0...20mA ±0.4% 4...20mA ±0.5% Temperature error ±0.01%/K (with reference to the output range) Linearity error ±0.1% (with reference to the output range) Repeatability (in steady state at 25 C, (with ±0.05% reference to the output range) Output ripple; Range 0 to 50kHz (with reference ±0.05% to the output range) HB140E - CPU SC - RE_ - Rev. 07/45 3-17

Analog Output Status, Interrupts, Diagstics Interrupts Diagstics functions Substitute value can be applied Data for selecting an actuator Output value (rated values) - Voltages ±10V 0... 10V - Interrupts ±20mA 0... 20mA 4... 20mA Load resistance (in the minal range of the outputs) - for voltage outputs min. 1kΩ capacitive load max. 100nF - for current outputs max. 500Ω inductive load max. 100μH Voltage outputs - Short-circuit protection - Short-circuit current max. 25mA Data for selecting an actuator Current outputs - No-load voltage max. 16V Destruction limit against voltages/currents - Voltages at outputs to M ANA max. 16V (30V for 10s) - Current max. 30V internal limited Connection of actuators - for voltage output 2-conductor connection 4-conductor connection t - for current output 2-conductor connection 3-18 HB140E - CPU SC - RE_ - Rev. 07/45