GCAN-208-1/-2. Fiber-CAN converter. User Manual

Similar documents
The I-2532 CAN to Fiber Converter

TD_CAN Transceiver Modules Application Guide 2017

I-2533CS series User Manual

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

OPERATING INSTRUCTIONS AND SPECIFICATIONS. NI 9853E 2-Port, High-Speed CAN Module

The i-7531 CAN Repeater

ADA User manual ADA Multimode Fibre-Optic to Current Loop Converter

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

Intelligent CAN Bus Multi-drop Bus Fiber Optic Converter User Manual

HFD CAN Bus Fiber Optic Converter User Manual

Magnetic absolute single-turn encoder BMSH MAGRES parallel

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

EM-CAN. Field-bus Stepper Drive. Leadshine Technology Co., Ltd. Website:

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

CAN Repeater. CRep S4.../S24/RMD. User Manual. Thomas Wünsche

DISCRETE INPUT MODULE, 16 points

1 Introduction. 1.1 General installation information

Magnetic absolute multi-turn hollow shaft encoder BMMH MAGRES SSI

HFD-FO-LON Series Lonworks Multi-drop Bus Fiber Optic Modem Datasheet & User Manual

FEATURES. Static Current (ma) Baud rate (bps) TD321D485H-E 321RHE k TD521D485H-E 521RHE k

OPERATING INSTRUCTIONS NI Port, Low-Speed/Fault Tolerant CAN Module

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

WIRELESS MODBUS GATEWAY WGW410

High precision measurement system for current and voltage IHC-A/B-RM01/03

ICF-1280I Series Quick Installation Guide

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

Modbus communication module for TCX2: AEX-MOD

EY-EM 527: Remote I/O module, ecolink527

OPERATING INSTRUCTIONS NI Port DeviceNet Module

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

PROFIBUS HUB REPEATER

Since 1987 Developed, Created and Made in Spain NDR6 OPTIC DATA TRANSCEIVER

1000 ~ 3000W 1U Distributed Power System RCP-1U Rack System

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

50W Constant Current (700mA) Dimming LED Driver

maxon document number:

H LONTalk Integration Node For Use With H704 and H663 Branch Current Monitors (BCM) H NOTICE DANGER INSTALLATION GUIDE DIMENSIONS

TECHNICAL DATASHEET #TDAX022420

Systems. Roland Kammerer. 29. October Institute of Computer Engineering Vienna University of Technology. Communication in Distributed Embedded

75W Constant Current (700mA) LED Driver

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

CAN Repeater. CRep N.../S24/RMD. User Manual

! Detection range up to 130 mm. ! Data transmission up to 1.5 MBit/s. ! Devices for PROFIBUS. ! Sturdy aluminium housing

AG FB-CAN. Absolute encoder viva CAN. Product Manual E-V0204.doc

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

TD_485 Transceiver Modules Application Guide 2017

TECHNICAL DATASHEET #TDAX INPUTS, 2 BIDIRECTIONAL

EMS THOMAS WÜNSCHE. CANwatch. CAN Physical Layer Analyser. User Manual. Documentation for CANwatch version 1.2. Documentation date: November 2004.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FRnet Remote I/O Modules

SUNYUAN ISO Series Analog signal Isolation Transmitter. Industrial Acceleration Sensing Transmitter

CAN-CLOCK Real Time Clock with CAN Interface Hardware-Manual

Artistic Licence. Candle-Power CP12. User Guide. Download this user guide by scanning the following QR code: Candle-Power CP12 User Guide Version 4-8

FOM-5A, 6A Asynchronous Fiber Optic Modems

JZ878 RF Data Radio. User s Manual

Since 1987 Developed, Created and Made in Spain NDV6/ND6V VIDEO & DATA TRANSCEIVER, AUDIO & CONTACT

S0 pulse counter. with S-Bus interface. Main features: Order number. Technical Data. Mounting

Since 1987 Developed, Created and Made in Spain NDV5/ND5V VIDEO & DATA TRANSMITTER/RECEIVER

DRP-3200 series. 3200W Rack Mountable Front End Rectifier. File Name:DRP-3200-SPEC Sicherheit ID

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Serial data converters ILPH range

Revision to the Operating Instructions

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

MultiNet. Instruction Manual. Digital Energy Multilin. Serial to Ethernet Converter. Manual P/N: A2 Copyright 2009 GE Multilin

satech SynchroStar GPS 200 Series

onlinecomponents.com

CompoNet Gateway Unit for CC-Link

Energy Management Energy Meter Type EM21 72R Retro-Fit

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

RCP-1600 series. 1600W Rack Mountable Front End Rectifier. File Name:RCP-1600-SPEC Sicherheit ID

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

EY-EM 522, 523: Remote I/O module, ecolink522, 523

MDW-45 Converter RS RS-422/485

CP485-4 User s Manual

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

U1601 ENERGY CONTROL SYSTEM

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

Energy Management Energy Analyzer Type EM210 MID

Energy Management Energy Meter GM3T E GM3T-RS485 E

MODEL: R1C-GH. Remote I/O R1X Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Multimeter 500CVD21 RTU500 series

GPNP Inc. NT384 NT1 User Manual. Revision /6/2002. Information in this guide is subject to change without notification.

Max. Output Power. Typical Efficiency (2) 450 ma 90 ~ 305 Vac 267~445Vdc 200 W 93.0% EUC-200S045ST

HEC-100RTA-48QSCA Rev A1.0

DSEM640. DSEControl PROGRAMMABLE CONTROLLER FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

Typical Efficiency (1) 350 ma 90 ~ 305 Vac 428 Vdc 150 W 93.5% EUC-150S035DT

s Climatix extension module 26 I/Os POL985.00/XXX

RKP-1U Rack System. 2000~6000W 1U Distributed Power System. File Name:RKP-1U RACK SYSTEM-SPEC Sicherheit ID

GC9838-LR - INTELLIGENT HYBRID PLC-RF DIN RAIL MODEM

DC/DC Converter VRA_YMD-6WR3 & VRB_YMD-6WR3 Series

P3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. IEC 950, UL 1950 and EN certified UL Recognized Component

GETTING STARTED GUIDE NI Port DeviceNet Module

AC/DC Converter LD20-26Bxx Series

DOBLE F6150SV TECHNICAL SPECIFICATIONS

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

TECHNICAL DATASHEET #TDAX INPUTS, 5 OUTPUTS VALVE CONTROLLER

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5

Transcription:

GCAN-208-1/-2 Fiber-CAN converter User Manual

Contents 1 Introduction... 3 1.1 Overview... 3 1.2 Properties at a glance... 3 2 Interface specification... 4 3 Connection and use... 6 3.1 CAN-Bus configuration... 6 3.2 Connect to Fiber... 7 3.3 Connect to CAN-Bus... 7 3.4 System LED... 8 4 Technical specifications... 9 Sales and service... 10 2

1 Introduction 1.1 Overview The GCAN-208-1/-2 converter has integrated two/one standard CAN-Bus interface, one/two fiber interface (Single mode or multi mode or SC or ST). GCAN-208 series converter can build a connection between Fiber Bus and CAN-Bus. With this converter in pairs, users can easily extend the distance of CAN-Bus and eliminate the interference effectively. It can also prevent the bus from electromagnetic interference, ground loop interference and lightning strike. 1.2 Properties at a glance Power supply: 9~30V(50mA, 24V DC) Surge immunity level: ±1KV Working temperature range from -40 to 85 C Operating humidity range: 5% to 95% RH no condensation Integrated one or two CAN-Bus interface with terminal (Depending on the model) CAN-Bus signals include: CAN_H, CAN_L, CAN_GND CAN-Bus supports CAN2.0A and CAN2.0B frame format, conform to ISO/DIS 11898 standards CAN-Bus baud rates range from 5Kbps to 1Mbps, configured by DIP switch CAN-Bus isolation converter insulation voltage: DC 1500V Fiber interface: SC, ST optional Fiber transmission mode: single mode, multi mode optional Size: (L)121mm * (W)93mm * (H)22mm 3

2 Converter installation 2.1 Converter fixation GCAN-208 series converter can be fixed on the inside of the rack or added DIN rail attachment. GCAN-208 series converter's interface specifications are shown in figure 2.1 and 2.2. After power up the converter, it will be work in the working state. Figure 2.1 GCAN-208-1 dimensions Figure 2.2 GCAN-208-2 dimensions Power interface Description 9-30V 9-30V DC+ EARTH Earth GND 9-30V DC- CAN-Bus interface Description CAN1-H CAN1 channel CAN_H CAN1-G CAN1 channel CAN_G CAN1-L CAN1 channel CAN_L CAN2-H CAN2 channel CAN_H CAN2-G CAN2channel CAN_G CAN2-L CAN2channel CAN_L Fiber interface Description 4

TX Fiber transmit interface RX Fiber receive interface Table 2.1 Interface definition 5

3 Connection and use 3.1 CAN-Bus configuration Before using the GCAN-208 series converter, users have to configure the parameter of the CAN-Bus. 3.1.1 Configure CAN-Bus baud rate The baud rate of CAN-Bus range from 5K to 1000K, configured by DIP switch. Before power on the converter, open the shell of the converter. The baud rate can be configured by DIP switch. "1 2 3 4" are used to configure CAN1. "5 6 7 8" are used to configure CAN2. Table 3.1 is the example of the baud rate of CAN1. Graphics Definition Baud rate Graphics Definition Baud rate 0000 1000k 0001 800k 0010 666k 0011 500k 0100 400k 0101 250k 0110 200k 0111 125k 1000 100k 1001 80k 1010 50k 1011 40k 1100 20k 1111 13.33k 1101 10k 1110 5k Table 3.1 Baud rate of GCAN-208 series 6

3.1.2 Configure CAN-Bus termination Two CAN channels of GCAN-208 converter have already integrated 120Ω termination by DIP switch. 3.2 Connect to Fiber The two fiber interface of GCAN-208 converter is SC or ST. The fiber transmission mode is single mode or multi mode. NOTE: When connecting the fiber, the RX should be connected to TX, TX to RX. 3.3 Connect to CAN-Bus In practical use, users only need to connect the CAN_H to CAN_H and CAN_L to CAN_L, then communication can be realized. The CAN-Bus network adopts topological structure, only the two furthest terminal need to connect 120Ω terminal resistance between CAN_H and CAN_L. For branch connection, its length should not be more than 3 meters. CAN-Bus nodes connection as shown in figure 3.1. Figure 3.1 CAN-Bus network Note: CAN-Bus using ordinary twisted pair. The relationship between the bus length and baud rate is shown in Table 3.2. Baud rate 7 Bus length 1 Mbit/s 40m 500 kbit/s 110m 250 kbit/s 240m 125 kbit/s 500m 50 kbit/s 1.3km 20 kbit/s 3.3km 10 kbit/s 6.6km 5 kbit/s 13km Table 3.2 Baud rate and maximum bus length reference table

3.4 System LED The GCAN-208 series converter has integrated one POWER indicator, one SYS indicator, one or two Fiber indicator and two or one CAN indicators. More functions are shown in table 3.3 and 3.4. Indicator light Color Indicates the state POWER Green System power supply indication SYS Green System operation indication Fiber Green Fiber communication indication CAN1 Red/green CAN1 communication status indication CAN2 Red/green CAN2 communication status indication Table 3.3 Indicator of GCAN-208 series After power on the converter, the POWER and SYS indicator lights indicate that power is being supplied and the system is initializing. Otherwise, it indicates power failure or an error occurred. After the connection of Fiber Bus and CAN-Bus, when the bus has data transmission, corresponding Fiber and CAN indicators will flash. Indicator light Status Indicates the state POWER ON Power supply normal OFF Power supply error OFF System error SYS ON System initialization failed Blinking System initialization pass Fiber OFF Fiber data transmission or no data Blinking Fiber data reception OFF CAN-Bus no data CAN1/CAN2 Green blinking CAN-Bus data transmission Red CAN-bus error Table 3.4 Indicator light Status of GCAN-208 series 8

4 Technical specifications Connection Fiber CAN Interface characteristics Fiber transmission mode CAN interface CAN baud rate Electrical isolation CAN termination resistor Power supply Power supply voltage Power supply current SC, ST optional OPEN3 terminal blocks Single mode, multi mode optional ISO 11898 standard, CAN2.0A/B 5Kbit/s~1Mbit/s, configured by DIP switch 1500V, DC-DC Integrated, through the DIP switch to enable +9~30V DC Maximum 50mA (24V DC) Environmental testing Working temperature -40 ~+85 Working humidity 15%~90%RH, no condensation EMC test EN 55024:2011-09 EN 55022:2011-12 Protection grade IP 20 The basic information Outline size Weight 121mm *93mm *22mm 230g 9

Sales and service Shenyang Guangcheng Technology Co., Ltd. Address: Industrial Design Center, No. 42 Chongshan Middle Road, Huanggu District, Shenyang City, Liaoning Province. QQ: 2881884588 E-mail: 2881884588@qq.com Tel: +86-024-31230060 Website: www.gcgd.net Sales and service Tel: +86-18309815706 After - sales service telephone Number: +86-13840170070 WeChat Number:13840170070 10