FCC ID: CASTMAH5A REPORT NUMBER 1919 SEPTEMBER 2003 RADIO PERFORMANCE MEASUREMENTS FCC ID: CASTMAH5A SN: In accordance with

Similar documents
Measurement Procedure & Test Equipment Used

FCC Part 90 Certification Application. FCC Form 731. For The. Guardian UHF RADIO MODEM FCC ID: NP

Test Report. Prepared for: Becker Avionics, Inc. Model: TG Description: Aeronautical basestation radio used for emergencies

REPORT ON Radio testing of the VERTEX STANDARD VX-2100-G6-45 / VX-2200-G6-45 In accordance with ANSI/TIA/EIA-603, RSS-119. Report number TA000506

Vertex Standard Co., Ltd. Page 1 of 38

MODEL: P5400 UHF-L Portable Radio

Spectrian Dual Mode Cellular Power Amplifier Model No.: SCLPA 800 CR FCC ID: I2ONTHX51AA

R. Grant, Wireless Group Manager

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

EXHIBIT 10 TEST REPORT. FCC Parts 2 & 24

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

Class II Permissive Change Report

FCC PART 95 MEASUREMENT AND TEST REPORT HENAN ESHOW ELECTRONIC COMMERCE CO., LTD

MEASUREMENT PROCEDURE AND TEST EQUIPMENT USED

DIGITAL OUTSTATION WITH RESPECT TO THE FCC RULES CFR 47, PART 90 INTENTIONAL RADIATOR SPECIFICATION ON BEHALF OF PALMER ENVIRONMENTAL

PCTEST Engineering Laboratory, Inc B Dobbin Road Columbia, MD U.S.A. TEL (410) FAX (410)

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87.

7.3 Spurious Emission at Antenna Termianal

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

FCC & IC Class II Permissive Change Report

FCC PART & IC RSS GHz FHSS TEST REPORT

1 Hines Rd. Ottawa, Ontario K2K 3C7. PCS Low Power Repeater. 303 River Road, R.R. 5 Ottawa, Ontario K1V 1H2. Authorized By:

FCC Test Report. Report No.: AGC FE02 CLIENT : INNOVATIVE CONCEPTS AND DESIGN LLC. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

ROGERS LABS, INC. TEST REPORT For APPLICATION of CERTIFICATION. For

FCC Part 90 Mobile UHF Repeater Test Report

Electrical FOR:

Test Report: 5R Champlain Street Dieppe, New Brunswick Canada E1A 1P6. Model Number: Verification

FCC Part 90 Rules Test Report

TIMCO ENGINEERING INC.

A Test Lab Techno Corp. Report Number:1410FR27

FCC Part 90 Rules Test Report

FCC PART 90 AND IC RSS-119, RSS-GEN TEST REPORT

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

TEST REPORT FROM RFI GLOBAL SERVICES LTD

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

FAX50 and FAX150W FCC Certification Measurements

Test Report: 4R Champlain Street Dieppe, New-Brunswick Canada E4P 8L6. Model Number: Verification

ADDENDUM TO ITRON, INC. TEST REPORT FC FOR THE AUTOMATED METER READING SYSTEM, FC 200 FCC PART 101 PARTIAL TESTING DATE OF ISSUE: MAY 22, 2007

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR50 August 29, 2012 First Approval Report

Test Report. Bluetooth Transceiver in UPCS Base Station

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

As the responsible EMC Engineer, I hereby declare that the equipment tested as specified in this report conforms to the requirements indicated.

RF Test Report. Report No.: AGC EE13. CLIENT : Zhengzhou Eshow Import and Export Trade Co.,Ltd.

FCC Part 22H & 24E Measurement and Test Report

FCC Certification Test Report for the MEI Cashflow RFID Reader Base FCC ID: QP8EASITRAXRB

EN v1.2.1 ( ) TEST REPORT FOR n 1X2 PCIe MINICARD TRANSCEIVER MODEL NUMBER: AR5B91 REPORT NUMBER: 08U

SHURE ELECTROMAGNETIC COMPATIBILITY LABORATORY TEST REPORT

ELECTRICAL TESTING

REMARKS The customer has ordered two measurements mentioned above according to the standard EN

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

2310 to 2390 MHz, 3m distance MCS8 (MIMO) to 2500 MHz Restricted band MCS8 (MIMO)

TEST REPORT Part 95(A/B) & IC RSS-210(Issue 8)

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

Version TEST REPORT NO. DATE DESCRIPTION. HCTR1208FR49 August 29, 2012 First Approval Report

REPORT issued by an Accredited Testing Laboratory

Version TEST REPORT NO. DATE DESCRIPTION

Honeywell International, Inc.

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

RF TEST REPORT UAB TELTONIKA 2AJLOTM2500TLT TELTONIKA TM2500 RXA RF02R2

175 Science Parkway Rochester, NY W. Maude Avenue Sunnyvale, CA REPORT DATE: November 4, FINAL TEST DATE: October 31, 2008

Palstar, Inc. EMC TEST REPORT FOR. HF LDMOS Amplifier Model: LA-1K. Tested To The Following Standard: FCC Part 97 Subpart D. Report No.

The equipment will provide up to 50W RF output power in the MHz band.

EMC Test Report. Report No.: AGC EE01 : VR 6600PRO, VR 6610, VR 6700, VRP 6000, VRP 6800 : VERO GLOBAL COMMUNICATION CO.

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD. FCC ID: 2ADPC-G6 Report No.: LCS E

For. Unit D16/F. should not use it to claim FCC ID: 2AAIN-MNGLOS

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

DATES OF TESTS: From 03/10/2014 to 20/10/2014 and 25/02/2015. Open area test site in Aunainville (28) - FRANCE. Page 2 out of 54

TEST REPORT. For. Mobile Base Station. In conformity with. FCC Part24E (01 Oct, 2009) IC RSS-133 Issue5. Issue Date: 06 May, 2010

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

DUO-ART 120. SJO7W8 Amplifier 2AAEsART120 ELAD srl Via Col de Rust, 11 Sarone Caneva PN ITALY

EMC Test Report. Client: Wistron NeWeb Corporation. Tested by: Jeremy Pickens, Senior EMC Engineer. Reviewed by: David Schramm, Operations Manager

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. ION Audio, LLC. Portable Karaoke PA speaker with vocal effects

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Proware Technologies Co., Ltd. Wireless High Gain USB Adapter. Model No.

FCC Test Report. Report No.: AGC FE08. Attestation of Global Compliance (Shenzhen) Co., Ltd

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

FCC PART 80 & 90 TEST REPORT

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR. Dolphin CT50

FCC Part 22H&90S Test Report

FCC Radio Test Report

ACCORDING TO: FCC part 15 subpart C, and subpart B FOR:

REPORT issued by an Accredited Testing Laboratory

FCC TEST REPORT. For. SPECTRA Technologies Holdings Co. Ltd EFTPOS. Model No. : SPECTRA T1000

Test Report. Report Number: F161141E1. Equipment under Test (EUT): AIS Class B SO Transponder WideLink B600. Applicant:

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

FCC & Industry Canada Certification Test Report For the Primayer Ltd. EUREKA 3 FCC ID: OABCXG IC ID: 3305A-CXG970001

Test Report. Bluetooth Transceiver in UPCS Base Station. Panasonic Corporation of North America

ITL Page 2 of 71 Report No.:

EXHIBIT 3 : FCC (c) (TEST DATA) AND FCC (MEASUREMENT PROCEDURES) INTRODUCTION TO TRANSMITTER MEASUREMENTS, Part 2.

Test Report. Prepared for: Ubiquiti Networks, Inc. Model: RM5. Description: Rocket M5 FCC ID: SWX-R5M. FCC Part Date of Issue: April 24, 2015

T E S T - R E P O R T. Test Report No (Edition 1) for RF340-R. Inductive Tag Reader

EMC Test Data. Radio Test Report R Summit Data Communications SDC-MCF10G. Test Report R76253 Rev 3.0. Revision History.

Transcription:

REPORT NUMBER 1919 SEPTEMBER 2003 RADIO PERFORMANCE MEASUREMENTS On the TMAB12-H500 Mobile Transceiver FCC ID: CASTMAH5A SN: 19001327 In accordance with FCC 47 CFR Parts 22 and 90 PREPARED BY: Garry Pringle Test Technician CHECKED & APPROVED BY: SA Crompton Laboratory Manager TELTEST Laboratories Tait Electronics Limited PO Box 1645 558 Wairakei Road Christchurch New Zealand Phone : (64) (3) 3583399 Fax: (64) (3) 3580432 Page 1 of 47

REPORT ON : Type Approval Testing of the TMAB12-H500 (Serial No 19001327 ) in accordance with: FCC CFR 47 Parts 22 & 90 Report No 1919 FCC ID: CASTMAH5A PREPARED FOR : Tait Electronics Ltd PO Box 1645 558 Wairakei Rd Christchurch New Zealand DISTRIBUTION : TELTest Laboratory Mr S Crompton Copy No 1 Tait Electronics Ltd Mr. Des Fox Copy No 2 Tait Electronics Ltd Mr. Dave Wright Copy No 3 APPROVED : S. A. Crompton Compliance Laboratory Manager Date : All tests reported herein have been performed in accordance with the laboratory's scope of accreditation This document must not be reproduced except in full, without the written permission of the Compliance Laboratory Manager. Copy No: Page 2 of 47

DECLARATION OF CONFORMITY We, TELTEST LABORATORIES of 558 Wairakei Road, Christchurch New Zealand, declare under our sole responsibility that the product: Equipment: Type: Product code: Mobile Transceiver TMAH5A TMAB12-H500 Serial Numbers: 19001327 Quantity: 1 To which this declaration relates is in conformity with the following standards: FCC CFR 47 Parts 22 & 90 Signature: S. A. Crompton Compliance Laboratory Manager. Date: Page 3 of 47

TABLE OF CONTENTS TEST PAGE TRANSMITTER OUTPUT POWER (CONDUCTED) 5 AUDIO FREQUENCY FILTER 6 TRANSMITTER AUDIO FREQUENCY RESPONSE 7 MODULATION LIMITING 10 MODULATION LIMITING (STEADY STATE) 13 MODULATION LIMITING (INSTANTANEOUS) 16 OCCUPIED BANDWIDTH 19 SPURIOUS EMISSIONS (CONDUCTED) 32 (SPURIOUS EMISSIONS (RADIATED) EMC Report No:30825.1 TRANSMITTER FREQUENCY STABILITY (TEMPERATURE) 37 TRANSMITTER FREQUENCY STABILITY (VOLTAGE) 40 TRANSIENT FREQUENCY BEHAVIOR 41 LIST OF TEST EQUIPMENT 46 Page 4 of 47

TRANSMITTER OUTPUT POWER (CONDUCTED) TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1046 GUIDE: TIA/EIA-603 2.2.1 MEASUREMENT PROCEDURE: 1. The Equipment Under Test (EUT) was set up as shown in the following diagram. 2. The coaxial attenuator has an impedance of 50 Ohms. 3. The unmodulated output power was measured with an RF Power meter. MEASUREMENT RESULTS: Manufacturer s Rated Output Power: Switchable: 1 W and 25 W 425.1 MHz 1 W nominal 25 W nominal POWER (W) 1.0 24.6 Variation from Nominal (%) 0.0-1.6 MHz 1 W nominal 25 W nominal POWER (W) ~ ~ Variation from Nominal (%) ~ ~ Measurement Uncertainty (db) +0.63-0.68 LIMIT CLAUSE: FCC 47 CFR 90.205 Radio Type: Mobile Transceiver Frequency Band: 421 MHz ~ 512 MHz (o) The output power shall not exceed by more than 20% the manufacturer s rated output power for the particular transmitter. TEST SETUP: See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 5 of 47

TEST CONDITIONS: AUDIO FREQUENCY FILTER RESPONSE o C Ambient Temperature Relative Humidity % Standard Voltage V DC FCC 47 CFR 2.1047 GUIDE: TIA/EIA-603 2.2.15 MEASUREMENT PROCEDURE: This test was not carried out as the EUT meets the emission limits specified in 90.210. MEASUREMENT RESULTS: See Occupied Bandwidth tests on LIMIT CLAUSE: FCC 47 CFR 90.211 (a) (a) Transmitters utilizing analog emissions that are equipped with an audio low-pass filter must meet the emission limitations specified in 90.210. TEST SETUP: See page Occupied Bandwidth Page 6 of 47

TRANSMITTER AUDIO FREQUENCY RESPONSE PRE-EMPHASIS TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1047 (a) GUIDE: TIA/EIA-603 2.2.6 MEASUREMENT PROCEDURE: 1. The Equipment Under Test (EUT) was set up as shown in the following diagram. 2. An audio input tone of 1000Hz was applied with the level set to obtain 20% of maximum deviation. This was used as the 0dB reference point. 3. The AF was varied while the audio level was held constant. 4. The response in db relative to 1000Hz was measured. MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings.. LIMIT CLAUSE: TIA/EIA-603 2.2.6 TEST SETUP: See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 7 of 47

TRANSMITTER AUDIO FREQUENCY RESPONSE PRE-EMPHASIS FCC CFR 2.1047 (a) Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing Pre-Emphasis db 15 10 5 0-5 -10-15 -20-25 -30-35 100 1000 10000 Modulation Frequency Hz Deviation Upper Limit Lower Limit Page 8 of 47

TRANSMITTER AUDIO FREQUENCY RESPONSE PRE-EMPHASIS FCC CFR 2.1047 (a) Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing Pre-Emphasis db 15 10 5 0-5 -10-15 -20-25 -30-35 100 1000 10000 Modulation Frequency Hz Deviation Upper Limit Lower Limit Page 9 of 47

TRANSMITTER MODULATION LIMITING TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1047 (b) GUIDE: TIA/EIA-603 2.2.3 MEASUREMENT PROCEDURE: 1. The EUT was set up as shown in the following diagram. 2. The modulation response was measured at three audio frequencies while varying the input level. 3. Measurements were made for both Positive and Negative Deviation. MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: TEST SETUP: FCC 47 CFR 90.211 (a) See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 10 of 47

TRANSMITTER MODULATION LIMITING FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing Deviation khz 3 2.5 2 1.5 1 0.5 0 Modulation Characteristic Positive Deviation -60-50 -40-30 -20-10 0 10 Input Level dbm Limit 300Hz 1000Hz 2500Hz Deviation khz 3 2.5 2 1.5 1 0.5 0 Modulation Characteristic Negative Deviation -60-50 -40-30 -20-10 0 10 Input Level dbm Limit 300Hz 1000Hz 2500Hz Page 11 of 47

TRANSMITTER MODULATION LIMITING FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing Deviation khz 6 5 4 3 2 1 0 Modulation Characteristic Positive Deviation -60-50 -40-30 -20-10 0 10 Input Level dbm Limit 300Hz 1000Hz 2500Hz Deviation khz 6 5 4 3 2 1 0 Modulation Characteristic Negative Deviation -60-50 -40-30 -20-10 0 10 Input Level dbm Limit 300Hz 1000Hz 2500Hz Page 12 of 47

TRANSMITTER MODULATION LIMITING STEADY STATE TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1047 (b) GUIDE: TIA/EIA-603 2.2.3 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. The modulation response was measured with a level stepped 20 db above the level required to obtain 60% deviation at 1000Hz AF. 3. Measurements were made for both Positive and Negative deviation. MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: TEST SETUP: FCC 47 CFR 90.211 (a) 2.1047 (b) See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 13 of 47

TRANSMITTER MODULATION LIMITING STEADY STATE FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing Steady State Modulation Limiting 3.000 Deviation khz 2.500 2.000 1.500 1.000 0.500 0.000 100 1000 10000 Modulation Frequency Hz Positive deviation Negative Deviation Limit Page 14 of 47

TRANSMITTER MODULATION LIMITING STEADY STATE FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing Steady State Modulation Limiting 6.000 5.000 Deviation khz 4.000 3.000 2.000 1.000 0.000-1.000100 1000 10000 Modulation Frequency Hz Positive deviation Negative Deviation Limit Page 15 of 47

TRANSMITTER MODULATION LIMITING INSTANTANEOUS TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1047 (b) GUIDE: TIA/EIA-603 2.2.3 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. The modulation response was measured with a level stepped 20 db above the level required to obtain 60% deviation at 1000Hz AF. 3. Measurements were made for both Positive and Negative deviation. MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: TEST SETUP: FCC 47 CFR 90.211 (a) 2.1047 (b) See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 16 of 47

TRANSMITTER MODULATION LIMITING INSTANTANEOUS FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing Instantaneous Modulation Limiting 3.000 Deviation khz 2.500 2.000 1.500 1.000 0.500 0.000 100 1000 10000 Modulation Frequency Hz Positive deviation Negative Deviation Limit Page 17 of 47

TRANSMITTER MODULATION LIMITING INSTANTANEOUS FCC CFR 2.1047 (b) Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing Instantaneous Modulation Limiting 6.000 Deviation khz 5.000 4.000 3.000 2.000 1.000 0.000 100 1000 10000 Modulation Frequency Hz Positive deviation Negative Deviation Limit Page 18 of 47

OCCUPIED BANDWIDTH TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 49 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1049 (c) GUIDE: TIA/EIA-603 2.2.11 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. For analogue measurements: The EUT was modulated by a 2500Hz tone at an input level 16dB above a level that produced 50% deviation. The input level was established at the frequency of maximum response of the audio modulating circuit. For Data measurements: The EUT was modulated with an internally generated pseudorandom bit sequence at the appropriate Baud rates. 3. The Occupied Bandwidth was measured on the Spectrum Analyser with the controls set as shown on the following plots. MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: FCC 47 CFR 90.210 EMISSION MASKS Emission Mask D 12.5 khz Channel Spacing Analog; FFSK; THSD Emission Mask B 25.0 khz Channel Spacing Analog; Emission Mask C 25.0 khz Channel Spacing FFSK; THSD DATA SPEED FFSK 1200 bps 12.5 khz Channel Spacing FFSK 1200 bps 25.0 khz Channel Spacing THSD 12000 bps 12.5 khz Channel Spacing THSD 19200 bps 25.0 khz Channel Spacing (FFSK is Fast Frequency Shift Keying; THSD is Tait High Speed Data) TEST SETUP: For analogue modulation See page 46 for Test Equipment information AF Generator 87 111 84 62,66 86 Mod Analyser 88 EUT Cable Attenuator Cable Spectrum Analyser DC Page 19 of 47

OCCUPIED BANDWIDTH VOICE FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 12.5 khz Channel Spacing Page 20 of 47

OCCUPIED BANDWIDTH VOICE FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 12.5 khz Channel Spacing Page 21 of 47

OCCUPIED BANDWIDTH VOICE FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 25.0 khz Channel Spacing Page 22 of 47

OCCUPIED BANDWIDTH VOICE FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 25.0 khz Channel Spacing Page 23 of 47

OCCUPIED BANDWIDTH DATA FFSK FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 12.5 khz Channel Spacing Page 24 of 47

OCCUPIED BANDWIDTH DATA FFSK FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 12.5 khz Channel Spacing Page 25 of 47

OCCUPIED BANDWIDTH DATA FFSK FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 25.0 khz Channel Spacing Page 26 of 47

OCCUPIED BANDWIDTH DATA FFSK FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 25.0 khz Channel Spacing Page 27 of 47

OCCUPIED BANDWIDTH DATA THSD FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 12.5 khz Channel Spacing Page 28 of 47

OCCUPIED BANDWIDTH DATA THSD FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 12.5 khz Channel Spacing Page 29 of 47

OCCUPIED BANDWIDTH DATA THSD FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 25W 25.0 khz Channel Spacing Page 30 of 47

OCCUPIED BANDWIDTH DATA THSD FCC CFR 2.1049 (c) Tx FREQUENCY: 425.1 MHz 1W 25.0 khz Channel Spacing Page 31 of 47

SPURIOUS EMISSIONS (CONDUCTED) TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1051 GUIDE: TIA/EIA-603 2.2.13 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. The frequency range examined was from the lowest frequency generated within the EUT, to a frequency higher than the 10 th Harmonic: 100kHz to Fc-BW Fc+BW to 4.7 GHz 3. Spurious emissions which were attenuated more than 20dB below the limit were not recorded. MEASUREMENT RESULTS: See the tables on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: FCC 47 CFR 90.210 TEST SETUP: See page 46 for Test Equipment information. 87 5 AF Generator Signal Generator Mod Analyser 111 DC EUT Cable Attenuator Cable Spectrum Filter Analyser 83 60 84 57 123 Page 32 of 47

SPURIOUS EMISSIONS (CONDUCTED) FCC CFR 2.1051 Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing 425.1 MHz @ 1 W Emission Mask D Emission Frequency (MHz) Level (dbm) Level (dbc) ~ ~ ~ No emissions were detected at a level greater than 20 db below the limit. LIMITS: Carrier Output Power Watts Emission Mask D 12.5 khz Channel Spacing 50 + 10 Log 10 (P Watts ) 1 W -20 dbm 50 dbc 25 W -20 dbm 64 dbc Page 33 of 47

SPURIOUS EMISSIONS (CONDUCTED) FCC CFR 2.1051 Tx FREQUENCY: 425.1 MHz 12.5 khz Channel Spacing 425.1 MHz @ 25 W Emission Mask D Emission Frequency (MHz) Level (dbm) Level (dbc) ~ ~ ~ No emissions were detected at a level greater than 20 db below the limit. LIMITS: Carrier Output Power Watts Emission Mask D 12.5 khz Channel Spacing 50 + 10 Log 10 (P Watts ) 1 W -20 dbm 50 dbc 25 W -20 dbm 64 dbc Page 34 of 47

SPURIOUS EMISSIONS (CONDUCTED) FCC CFR 2.1051 Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing 425.1 MHz @ 1 W Emission Mask B Emission Frequency (MHz) Level (dbm) Level (dbc) ~ ~ ~ No emissions were detected at a level greater than 20 db below the limit. LIMITS: Carrier Output Power Watts Emission Mask B 25.0 khz Channel Spacing 43 + 10 Log 10 (P Watts ) 1 W -13 dbm 43 dbc 25 W -13 dbm 57 dbc Page 35 of 47

SPURIOUS EMISSIONS (CONDUCTED) FCC CFR 2.1051 Tx FREQUENCY: 425.1 MHz 25.0 khz Channel Spacing 425.1 MHz @ 25 W Emission Mask B Emission Frequency (MHz) Level (dbm) Level (dbc) ~ ~ ~ No emissions were detected at a level greater than 20 db below the limit. LIMITS: Carrier Output Power Watts Emission Mask B 25.0 khz Channel Spacing 43 + 10 Log 10 (P Watts ) 1 W -13 dbm 43 dbc 25 W -13 dbm 57 dbc Page 36 of 47

TRANSMITTER FREQUENCY STABILITY (TEMPERATURE) TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1055 (a) (1) GUIDE: TIA/EIA-603 2.2.2 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. The EUT was tested for frequency error from 30 o C to +50 o C in 10 o C increments 3. The frequency error was recorded in parts per million (ppm). MEASUREMENT RESULTS: See the plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: FCC 47 CFR 90.213 Frequency Range: Channel Spacing (khz) 421 MHz to 512 MHz Frequency Error (ppm) 12.5 2.5 25.0 5.0 TEST SETUP: See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT Environmental Chamber 20dB 3dB 67 117 120 Signal Generator 114 115 Page 37 of 47

TRANSMITTER FREQUENCY STABILITY (TEMPERATURE) FCC 47 CFR 2.1055 (a) (1) Tx FREQUENCY: 425.1 MHz 25W 12.5 khz channel Spacing 3.00 Tx Frequency Stability (Temperature) Frequency Error (ppm) 2.00 1.00 0.00-1.00-2.00-3.00-30 -20-10 0 10 20 30 40 50 Temperature (ºC) Error (ppm) Positive Limit Negative Limit Page 38 of 47

TRANSMITTER FREQUENCY STABILITY (TEMPERATURE) FCC 47 CFR 2.1055 (a) (1) Tx FREQUENCY: 425.1 MHz 25W 25.0 khz channel Spacing Frequency Error (ppm) 6.00 5.00 4.00 3.00 2.00 1.00 0.00-1.00-2.00-3.00-4.00-5.00-6.00 Tx Frequency Stability (Temperature) -30-20 -10 0 10 20 30 40 50 Temperature (ºC) Error (ppm) Positive Limit Negative Limit Page 39 of 47

TRANSMITTER FREQUENCY STABILITY (VOLTAGE) TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 2.1055 (d) (1) GUIDE: TIA/EIA-603 2.2.2 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. The EUT was tested for frequency error at an input voltage to the radio of 85% to 115%. 3. The frequency error was recorded in parts per million (ppm). MEASUREMENT RESULTS: Frequency Range: 421 MHz to 512 MHz Channel Spacing (khz) FREQUENCY ERROR (ppm) @ 425.1 MHz 11.73 V DC 13.8 V DC 15.87 V DC 12.5-0.03-0.04-0.03 25.0 0.04 0.05 0.01 FREQUENCY ERROR (ppm) @ MHz 12.5 ~ ~ ~ 25.0 ~ ~ ~ LIMIT CLAUSE: FCC 47 CFR 90.213 Channel Spacing (khz) Frequency Error (ppm) 12.5 2.5 25.0 5.0 TEST SETUP: See page 46 for Test Equipment information. PTT TREVA Test Automation 22 Digital Scope 21 DC Audio Analyser 87 116 Mod Analyser/ Counter Power Sensor 111 EUT 20dB 3dB 67 117 120 Signal Generator 114 Page 40 of 47

TRANSIENT FREQUENCY BEHAVIOR TEST CONDITIONS: Ambient Temperature 23 o C Relative Humidity 46 % Standard Voltage 13.8 V DC FCC 47 CFR 90.214 GUIDE: TIA/EIA-603 2.2.19 MEASUREMENT PROCEDURE: 1. The Equipment Under Test was set up as shown in the following diagram. 2. Measurements and plots were made following the TIA/EIA procedure. MEASUREMENT RESULTS: See the tables and plots on the following pages for 12.5 khz & 25.0 khz channel spacings. LIMIT CLAUSE: FCC 47 CFR 90.214 TEST SETUP: See page 46 for Test Equipment information. 2 SIG GEN 86 63, 65 DC AC EUT CABLE ATTENUATOR COMBINER LOAD 32 22 SCOPE DEMOD AM DEMOD FM MOD ANAL 12 Page 41 of 47

TRANSIENT FREQUENCY BEHAVIOUR FCC 47 CFR 90.214 Tx FREQUENCY: 425.1 MHz 25 W 12.5 khz Channel Spacing FREQUENCY TRANSIENT RESPONSE PERIOD 425.1 MHz @ 25 W Tx CARRIER PEAK VARIATION FROM NORMAL Key ON (khz) Key OFF (khz) t1 0.7 N/A t2-0.3 N/A t3 N/A 0.3 t2 t3 ppm -0.7 ERROR LIMIT (t2 t3) ppm 2.5 Confirm that during periods t1 and t3 the frequency difference does not exceed the value of one channel separation. Confirm that during the period t2 the frequency difference does not exceed half a channel separation. Confirm that during the period t2 to t3 the frequency difference does not exceed the frequency error limit. YES Y YES Y YES Y NO NO NO LIMIT: TRANSIENT PERIODS FREQUENCY RANGE 150MHz 174 MHz FREQUENCY RANGE 421MHz 512 MHz t1 (ms) 5 ms 10 ms t2 (ms) 20 ms 25 ms t3 (ms) 5 ms 10 ms Page 42 of 47

TRANSIENT FREQUENCY BEHAVIOUR FCC 47 CFR 90.214 Tx FREQUENCY: 425.1 MHz 25 W 12.5 khz Channel Spacing Page 43 of 47

TRANSIENT FREQUENCY BEHAVIOUR FCC 47 CFR 90.214 Tx FREQUENCY: 425.1 MHz 25 W 25.0 khz Channel Spacing FREQUENCY TRANSIENT RESPONSE PERIOD 425.1 MHz @ 25 W Tx CARRIER PEAK VARIATION FROM NORMAL Key ON (khz) Key OFF (khz) t1-0.6 N/A t2-0.4 N/A t3 N/A 0.4 t2 t3 ppm -0.9 ERROR LIMIT (t2 t3) ppm 5.0 Confirm that during periods t1 and t3 the frequency difference does not exceed the value of one channel separation. Confirm that during the period t2 the frequency difference does not exceed half a channel separation. Confirm that during the period t2 to t3 the frequency difference does not exceed the frequency error limit. YES Y YES Y YES Y NO NO NO LIMIT: TRANSIENT PERIODS FREQUENCY RANGE 150MHz 174 MHz FREQUENCY RANGE 421MHz 512 MHz t1 (ms) 5 ms 10 ms t2 (ms) 20 ms 25 ms t3 (ms) 5 ms 10 ms Page 44 of 47

TRANSIENT FREQUENCY BEHAVIOUR FCC 47 CFR 90.214 Tx FREQUENCY: 425.1 MHz 25 W 25.0 khz Channel Spacing Page 45 of 47

TELTEST LABORATORIES Test equipment List To facilitate inclusion on each page, the test equipment used is numbered and listed against the related test in the report. No Equipment Type Manufacturer Model Number Serial No Tait ID 1 Signal Generator Hewlett Packard HP8642B (Opt 001) 2512A00176 E3064 2 Signal Generator Hewlett Packard HP8648A 3430U00344 E3579 3 Signal Generator Agilent E4422B GB40050320 E3788 4 Signal Generator Hewlett Packard HP8648C 3443U00543 E3558 5 Signal Generator Rohde & Schwarz SMY01 1062.5502.11 841736/019 E3553 10 Spectrum Analyser Hewlett Packard HP8596E (Opt 140) 3346A00213 E3427 11 Modulation Analyser Hewlett Packard HP8901B (Opt 002) 2441A00393 E3073 12 Modulation Analyser Rohde & Schwarz FMA0852.8500.52 842541/001 E3554 13 Audio Analyser Hewlett Packard HP8903A 2308A02597 E3074 14 Power Head Hewlett Packard HP11722A 2320A00688 E3307 15 Power Meter Rohde & Schwarz NRVS 1020.1809.02 841954/005 E3555 16 Power Sensor Rohde & Schwarz URV5- Z4 395.1619. 55 841.498/003 E3557 20 Power Supply Hewlett Packard HP6032A 2441A-0041Z E3075 21 Power Supply Rohde & Schwarz NGS M32/10 192.0810.31 Fnr 434 E3556 22 Oscilloscope Tektronics TDS340 B013611 E3585 23 Universal Counter Goldstar FC2015U - 600801 E3550 24 Environ. Chamber Contherm Spatial Cal E3397 E3397 24 Environ. Chamber Contherm Temp Control E3397 E3397 25 Whirling Hygrometer Casella 3156/82 TA004 TA004 30 Directional Coupler Hewlett Packard HP778D-012 1144 07392 E3292 31 4 Port Combiner (CAST) Rohde & Schwarz DVU4,3W 201.4018.03 300.729/47 E3623 32 4 Port Combiner Rohde & Schwarz DVU4, 3W 201.4018. 03 300.971/28 E3572 33 3 Port Combiner Weinschel 1506A, 1W LD858 E3672 34 Mixer Spurious Emission Tait (3. 2GHz# Rfx#4.0 GHz) E3661 E3661 35 Mixer Transient ACP Minicircuits ZAD-1177031 ZAD-11 E3394 36 Voltmeter Hewlett Packard HP3478A 2545A25838 1559 37 Variac Yamabishi S-260-5 TX-533 E1737 38 Rx & Tx, RF Paths Tait CAST Interface E3067 E3067 40 Reference Dipoles Emco 3121C DB1 9510-1164 E3559 41 Biconical Antenna Emco 3110B 9307-1680 E3033 42 Reference Horn Antenna Emco DRG3115 9512-4638 E3560 43 Horn Antenna Emco DRG3115 2084 E3076 44 Corner 175-420 MHz Ailtech DM105A-T2 J1417-103 E3031 45 Corner 400-1000 MHz Ailtech DM105A-T3 J1418-108 E3036 46 S-LINE TEM CELL Rohde & Schwarz 1089.9296.02 338232/003 E3636 50 Amplifier 1MHz-1000MHz Amplifier Research 25W1000A 20444 E3637 51 Amplifier 10kHz-250MHz Amplifier Research 25A250 16373 E3570 52 Amplifier +21.7 db Tait ZFL-1000LN E3660 E3360 53 RF Filter 21.4M (CAST) Tait NDK21G-6DT E3069 E3069 54 RF Filter 21.4M (ACP) Tait NDK21G-6DT RA-7' E3249 55 Filter Notch Tait N/A - 56 Filter High Pass Tait 4 MHz N/A - 57 Filter Low Pass Tait MHz N/A - 60 RF Attenuator 250W Weinschel 45-30-34 JW663 E3386 61 RF Attenuator 150W Weinschel 40-20-33 CJ404 E3387 62 RF Attenuator 150W Weinschel 57-10-34 LB590 E3674 63 RF Attenuator 150W Weinschel 40-06-34 KV457 E3561 64 RF Attenuator 50W Weinschel 24-10-34 AZ0401 E3388 65 RF Attenuator 50W Weinschel 24-20-44 AW1266 E3562 66 RF Attenuator 25W Weinschel 33-20-33 BD5871 E3673 67 RF Attenuator 150W Weinschel 40-20-33 CJ405 E3733 70 RF Load 150W Bird 8166 524 E3625 71 RF Load 50W Weinschel F1426 BF0487 E3675 72 RF Load 50W Weinschel F1426 AE2490 E3624 73 RF Termination 20W Deltec 118.001 E3626 74 RF Termination 2W MCL NTRM-50 951215 E3574 75 RF Termination 2W MCL NTRM-50 954214 E3575 76 RF Termination 2W MCL NTRM-50 954214 E3576 80 20m Coax Cable Intelcom RG214/U-50(Ext Cal) CBL01 E3659 Page 46 of 47

81 2m Coax Cable Intelcom RG213/U-50 (Ext Cal) CBL02 E3658 82 3m Coax Cable BLUE) Suhner Sucoflex 104A 25033/4A E3694 83 1m Coax Cable (BLUE) Suhner Sucoflex 104A 25006/4A E3693 84 1m Coax Cable (BLUE) Suhner Sucoflex 104A 25005/4A E3692 85 1m Coax Cable (BLUE) Suhner Sucoflex 104A 25004/4A E3691 86 1m Coax Cable (BLUE) Suhner Sucoflex 104A 25003/4A E3690 87 Audio Analyser Hewlett Packard HP8903B 2818A04275 E3710 88 Spectrum Analyser Hewlett Packard HP8562E 3821A00779 E3715 89 Field Strength Meter Holaday HI-422 95661 E3630 90 Power Supply Hewlett Packard HP6012B 2524A00616 E3712 91 20m Coax Cable RG214/U-50 (Ext Cal) CBL01 E3404 92 LISN Emco 3825/2 9204-1961 E3040 93 EMC Test Instr Schaffner BEST +A 199825-010SC AT183 94 ESD Test Set Haefely PSD 25B 082 999 24 E3629 95 Vehicle Conducted Immunity Test Set Schaffner NSG 5000 IN5094-090 E3506 96 Burst Generator Schaffner NSG5003 AR5194-151 E3508 97 Battery Simulator Schaffner NSG 5004 IN1695-003 - 98 RF Injection Probe Fischer F120-9 121-99 BER Meter Datatool 5000 9405003-100 Oscilloscope Tektronics TDS380 B017095 E3782 101 Coupler Decoupler Network MEB S15 10344 E3563 102 Coupler Decoupler Network MEB S1/50 10328 E3564 103 Coupler Decoupler Network MEB AF2 10967 E3565 104 Coupler Decoupler Network MEB M3-1 12207 E3566 105 Coupler Decoupler Network MEB S25 10762 E3567 105 Coupler Decoupler Network MEB T2 10778 E3568 106 Coupler Decoupler Network MEB M2 10701 E3569 107 Benchlink Hewlett Packard E4444A Ver A.01.06 19980701-108 GPIB Software National Instruments Ver 1.6 500739A-00-109 Labview National Instruments Ver 5.1.1 500573J-00-110 Wavestar Tektronix WSTR31 Ver 2.4 063-2173-04-111 Modulation Analyser Hewlett Packard HP8901B (Opt 002) 3704A05837 E3786 112 113 Hi Level Mixer Tait E3933 114 Signal Generator Rohde & Schwarz SML03 1090.3000.13 100597 E4050 115 Environ. Chamber Contherm 5400 RHSLT.M 1416 E4051 116 Power Head Hewlett Packard HP11722A 2716A02037 1575 117 RF Attenuator Weinschel Model 1 BL9950 E4080 118 RF Attenuator Weinschel Model 1 BL9958 E4081 119 RF Attenuator 150W Weinschel 40-20-23 MF817 E4082 120 RF Splitter Combiner Minicircuits ZFSC-4-1 - E4083 121 RF Splitter Combiner Minicircuits ZFSC-4-1 - E4084 122 RF Splitter Combiner Minicircuits ZFSC-4-1 - E4085 123 Spectrum Analyser Agilent E4445A MY42510072 E4139 Page 47 of 47