PREPARED FOR: FOUNDATION PLAN & STRUCTURAL NOTES DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S1
PREPARED FOR: FRAMING PLANS DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S2
PREPARED FOR: SECTION DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S3
PREPARED FOR: FRAMING ELEVATIONS DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S4
PREPARED FOR: DETAILS DESIGNED BY: NJB DRAWN BY: NJB REVIEWED BY: BLSE S5
E L E C T R I C A L G E N E R A L N O T E S A. CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR EXACT SIZE AND LOCATION OF EQUIPMENT WHICH IS FURNISHED BY OTHERS AND CONNECTED BY ELECTRICAL. B. RECEPTAES, SWITCHES AND COVERPLATES COLOR SHALL BE GRAY. C. FINAL CONNECTION TO ALL MOTORS SHALL BE WITH FLEXIBLE CONDUIT CONNECTION. D. ALL PANELBOARDS, BACKBOARDS, TERMINAL CABINETS, ETC SHALL HAVE CUSTOM ENGRAVED MICARTA NAMEPLATE MECHANICALLY AFFIXED IDENTIFYING SYSTEM. E. PROVIDE GREEN GROUND CONDUCTOR IN ALL CIRCUITS - SIZE PER N.E.C. F. ALL EXPOSED CONDUITS, BOXES, STRAPS AND HANGERS IN THE CONTRACT AREA WHETHER NEW OR EXISTING THAT ARE PART OF THE ELECTRICAL SYSTEM SHALL BE PAINTED TO MATCH ADJACENT FINISH. G. PROVIDE CONCRETE MARKER AT END OF ALL CONDUITS STUBBED OUT OF BUILDING FOR FUTURE USE. MARKER SHALL BE 6" DIA X 18" HIGH WITH 2" ABOVE FINISHED GRADE. INSCRIBE IN TOP OF MARKER "E" FOR ELECTRICAL,"T" FOR TELEPHONE,"V" FOR TV CABLE,"F" FOR FIRE ALARM, AND "IC" FOR INTERCOM. H. GENERAL CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING ANY WORK, AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. FAILURE TO DO SO INDICATES THAT THE CONTRACTOR ACCEPTS THE CONDITIONS AS THEY EXIST, AND SHALL PERFORM THE WORK REQUIRED AS SHOWN AND SPECIFIED. I. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND REVIEW THE SPECIAL EQUIPMENT SUBMITTALS PRIOR TO SUBMITTING THE ELECTRICAL SUBMITTALS. ANY ELECTRICAL EQUIPMENT, CONDUIT, AND WIRE SIZE CHANGES RESULTING FROM THIS REVIEW SHALL ALSO BE SUBMITTED FOR APPROVAL. J. FINAL CONNECTION TO ALL DRY TYPE TRANSFORMERS SHALL BE WITH FLEXIBLE CONDUIT CONNECTION. K. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FAULT CURRENT CALCULATIONS FOR THE SERVICE EQUIPMENT AND SHALL MARK THE EQUIPMENT WITH THE AVAILABLE FAULT CURRENT AND DATE OF THE CALCULATION PER NEC 110.24. REFER TO TYPICAL SERVICE EQUIPMENT FAULT CURRENT LABEL DETAIL. L. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ARC FAULT LABELS PER NFPA 70E ARTIE 110.16 FOR NEW EQUIPMENT. THE OWNER SHALL PROVIDE AVAILABLE CALCULATION DATA FOR THE EXISTING EQUIPMENT IN THE ELECTRICAL SYSTEM. REFER TO TYPICAL ARC FLASH HAZARD LABEL DETAIL. ABBREVIATIONS AFF - ABOVE FINISHED FLOOR C. - CONDUIT C/L - CENTERLINE EC - ELECTRICAL CONTRACTOR EF - EXHAUST FAN G - GROUND CONDUCTOR GFI - GROUND FAULT PROTECTION LTG - LIGHTING LTS - LIGHTS RECEPT - RECEPTAE UNO - UNLESS NOTED OTHERWISE WH - WATER HEATER WP - WEATHERPROOF A/C - AIR CONDITIONER COND - CONDENSING UNIT IHP - INDOOR HEAT PUMP OHP - OUTDOOR HEAT PUMP NL - NIGHT LIGHT AMPERE RATING NUMBER OF POLES NEMA RATING DISCONNECT SWITCH DESCRIPTION NOMENATURE E L E C T R I C A L L E G E N D EAST SIGN PANEL PANELBOARD Voltage: Phase: Wire: Mounting: ESN Mains: NEMA Rating: Options: AIC Rating: OVERHEAD CONDUCTOR RACEWAY INSTALLED CONCEALED IN WALLS AND/OR ABOVE CEILING RACEWAY INSTALLED EXPOSED RACEWAY INSTALLED CONCEALED IN FLOOR SLAB AND/OR BELOW GRADE TOTAL CONNECTED LOAD: / 240 TOTAL AMPS UNDERGROUND CONDUCTOR 240V 1 PHASE PANEL ELECTRIC METER AND METER BASE POWER POLE POLE MOUNTED TRANSFORMER DUPLEX RECEPTAE; 125V; 20A; 3 POLE GND; MT 18" AFF TO C/L UNLESS NOTED OTHERWISE; NEMA 5-20R; HUBBELL SERIES HBL5352 WEST SIGN PANEL PANELBOARD Voltage: Phase: Wire: Mounting: WSN Mains: NEMA Rating: Options: AIC Rating: TOTAL CONNECTED LOAD: / 240 TOTAL AMPS PREPARED FOR: FL AUTH: 00006680 FL PE: 73790 DAN PROFESS L I EL J IC E NS E No. 73790 WH STATE OF FLORIDA I ONA L I TE ENG I NEER 0' 10' 20' 30' ONE INCH EQUALS TEN FEET SCALE IN FEET NORTH LEGEND, NOTES, AND SCHEDULES DESIGNED BY: DRAWN BY: REVIEWED BY: E1 DW
.BLDG 100 KEYNOTES WEST SIGN KEYNOTES EAST SIGN E COLLEGE BLVD E COLLEGE BLVD WEST MONUMENT SIGN EAST MONUMENT SIGN PREPARED FOR: FL AUTH: 00006680 FL PE: 73790 DAN PROFESS L I EL J IC E NS E No. 73790 WH STATE OF FLORIDA I ONA L I TE ENG I NEER 0' 10' 20' 30' ONE INCH EQUALS TEN FEET SCALE IN FEET NORTH ELECTRICAL SITE PLANS DESIGNED BY: DRAWN BY: REVIEWED BY: E2 DW
SHEET NOTES KEYNOTES ALUMINUM VENT FULL LED DISPLAY ALUMINUM BRICK REVEAL BRICK REVEAL LOGO SIGN BOX BRICK REVEAL E/WSN BRICK FINISH GRADE END ELEVATION TYPICAL EACH END SIDE ELEVATION TYPICAL EACH SIDE SIGN ELEVATION AND SINGLE LINE POWER RISER MONUMENT SIGN ROUGH IN DETAIL PREPARED FOR: FL AUTH: 00006680 FL PE: 73790 DAN PROFESS L I EL J IC ENS E No. 73790 WH STATE OF FLORIDA I ONA L I TE ENG I NEER 0' 10' 20' 30' ONE INCH EQUALS TEN FEET SCALE IN FEET NORTH ELECTRICAL ELEVATIONS, SINGLE LINE, AND DETAILS DESIGNED BY: DRAWN BY: REVIEWED BY: E3 DW
Arc Flash and Shock Hazard Appropriate PPE Required 22" 1.53 #5 Flash Hazard Boundary cal/cm2 Flash Hazard at 18 inches PPE Level FR shirt and FR pants or FR coverall 480V 42" 12" 1" VAC Shock Hazard when cover is removed Limited Approach Restricted Approach - Class 1 Voltage Gloves Prohibited Approach - Class 1 Voltage Gloves TYPICAL ELECTRICAL EQUIPMENT NAMEPLATE Equipment Name: PANEL MDP VALID FOR NORMAL SYSTEM CONFIGURATION ONLY. TYPICAL ARC FLASH HAZARD LABEL DETAIL BACK VIEW FRONT VIEW 90 DEGREE AND 180 DEGREE DOOR STOP BRACKET SIDE VIEW 1 HOLE FAN PANEL SWITCH BKT 22.5" LONG UNISTRUT (2X) 22.500 49.500 6.250 17.500 7.125 30.000 2.880 8.000 4.000 17.000 CONDUIT MARKER DETAIL UNDERGROUND CONDUIT DETAIL 10.000 BOTTOM VIEW GROUND MOUNTING STRAPS NOTES: 20.000 ALUMINUM ENOSURE DETAIL PREPARED FOR: FL AUTH: 00006680 FL PE: 73790 DAN PROFESS L I EL J IC ENS E No. 73790 WH STATE OF FLORIDA I ONA L I TE ENG I NEER 0' 10' 20' 30' ONE INCH EQUALS TEN FEET SCALE IN FEET NORTH ELECTRICAL DETAILS DESIGNED BY: DRAWN BY: REVIEWED BY: E4 DW