s Screw connection system RKB 4 BKA 2,5 BKA 4 BKA 0 Rail mount on TS 5 / TS 32 / TS 35 / Direct mounting Connection diagram M 3 M 2,5 M 3 M 4 Connection type Dimension (L x W x H) with TS 5 mm with TS 32 mm with TS 35 x,5 mm Direct mounting Gauge plug acc. to EN 60 4- / Flammability class UL 4 For certifications and approvals Flexible/Flexible (with ADH acc. to DIN 46 228/) mm 2 Contact wire range mm 2 Features Number of cross connection channels Test pick-off feature Accessories End plate AP beige blue Partition plate TW beige blue Insulation plate TRS 2 poles Outer insulated cross connector A poles 3 poles Outer insulated cross connector A poles 4 poles Outer insulated cross connector A poles 0 poles Outer insulated cross connector AQI0 poles End holder EH/Direct mounting screw Endhalter EH/Rail mounting End holder EH/Direct mounting pin Screw driver Further accessories Further accessories like marking systems, test adapters, covers, end brackets etc. you can find on the pages for accessories specified below! * Applies 2 x 6 x 2,5 RKB 4 beige 08.2/00 RKB 4 blue 08.5/00 * 32 30 30 4 22-0 4 3 0,2-2,5 AP,5-4 238.2/50 238.5/50 TW,5-4 20.2/50 20.5/50 2566.2/00 208.0/20 208.0/0 Q 0 200.0/0 EH 235.2/50 086.0/ 22 x 5 x 23 BKA 2,5/ beige 320.2/00 BKA 2,5/ blue 320.5/00 400 300 300 24 20 20 2,5 22-2 0,2-2,5 A/5/ 2032.0/50 A/5/ 2033.0/50 A/5/ 2044.0/50 AQI 0/5/ 2045.0/0 EH 2 236.2/50 EH 5/BKA 245.2/50 EH 2-Z 24.2/50 086.0/ 22 x 6 x 23 BKA 4/ beige 258.2/00 BKA 4/ blue 258.5/00 400 300 300 32 30 25 4 22-0 A/6/ 225.0/50 A/6/ 226.0/50 A/6/ 240.0/50 AQI 0/6/ 2045.0/0 EH 2 236.2/50 EH 5/BKA 245.2/50 EH 2-Z 24.2/50 086.0/ 30 x 8 x 3 BKA 0/ beige 4.2/50 BKA 0/ blue 4.5/50 400 300 300 5 5 5 0 22-8 A5 V2 0,2-0 - 0,2-0 - 0 A/8/ 206.0/50 A/8/ 2068.0/50 A/8/ 206.0/50 EH 3 23.2/20 EH 35/BKA 246.2/50 08.0/ 4
SRK 2,5/5 RK,5-4/5 SRK 2,5 RK,5-4 M 2,5 M 3 M 2,5 M 3 26 x 5 x 2,5 2 x 6 x 34,5 45 x 5 x 43,5 45 x 5 x 3 45 x 6 x 48 45 x 6 x 43,5 SRK 2,5/5 beige 035.2/00 SRK 2,5/5 blue 035.5/00 24 5 20 2,5 22-4 RK,5-4/5 beige 00.2/00 RK,5-4/5 blue 00.5/00 RK,5-4/5/STB 03.2/00 32 30 40 4 22-0 SRK 2,5 beige 030.2/00 SRK 2,5 blue 030.5/00 24 5 20 2,5 22-4 RK,5-4 beige 05.2/00 RK,5-4 blue 05.5/00 RK,5-4/STB 00.2/00 32 30 40 4 22-0 0,2-2,5 0,2-2,5 AP 2,5/5 242.2/50 242.5/50 TW 2,5/5 2428.2/50 2428.5/50 2422.0/50 AP,5-4 238.2/50 238.5/50 TW,5-4 20.2/50 20.5/50 2566.2/00 208.0/20 AP-SR 200.2/50 200.5/50 TW 2,5 2426.2/50 2426.5/50 208.0/20 AP,5-4 238.2/50 238.5/50 TW,5-4 20.2/50 20.5/50 2566.2/00 208.0/20 2423.0/50 2424.0/20 208.0/0 208.0/0 208.0/0 Q 0 2425.0/0 Q 0 200.0/0 Q 0 200.0/0 Q 0 200.0/0 085.0/ 086.0/ 085.0/ 086.0/ 5
s Screw connection system RK 2,5 RK 2,5/35 N/2 Q RK 2,5-4 RK 2,5-4/35 Rail mount on TS 32 / TS 35 Connection diagram M 2,5 M 2,5 M 3 M 3 Connection type Dimension (L x W x H) with TS 32 mm with TS 35 x,5 mm Gauge plug acc. to EN 60 4- / Flammability class UL 4 For certifications and approvals Flexible/Flexible (with ADH acc. to DIN 46 228/) mm 2 Contact wire range mm 2 Features Number of cross connection channels Test pick-off feature Accessories End plate AP beige blue Partition plate TW beige blue Insulation plate TRS Screw driver Further accessories Further accessories like marking systems, test adapters, covers, end brackets etc. you can find on the pages for accessories specified below! * Applies 6 48 x 5 x 5,5 48 x 5 x 4 RK 2,5 beige 26.2/00 RK 2,5 blue 26.5/00 RK 2,5 DS beige 48.2/00 ) RK 2,5 DS blue 48.5/00 ) 24 20 20 2,5 22-2 0,2-2,5 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 2566.2/00 256.0/50 2568.0/50 256.0/20 Q 0 250.0/0 085.0/ ) cross connection not possible 62,5 x 5, x 4 RK 2,5/35 N/2 Q/35 beige 54.2/00 RK 2,5/35 N/2 Q/35 blue 54.5/00 RK 2,5/35 N/S/2 Q/35 beige 55.2/00 2) RK 2,5/35 N/S/2 Q/35 blue 55.5/00 2) 24 20 20 2,5 22-4 0,2-2,5 2 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 Z,5/2 30.8/50 Z,5/3 3.8/50 Z,5/4 32.8/20 Z,5/5 33.8/20 Z,5/6 34.8/20 Z,5/ 35.8/20 Z,5/8 36.8/0 Z,5/ 3.8/0 Z,5/0 38.8/0 085.0/ 2) with screen rail 48 x 6 x 5,5 48 x 6 x 4 RK 2,5-4 beige 00.2/00 RK 2,5-4 blue 00.5/00 RK 2,5-4/STB beige 008.2/00 3) RK 2,5-4 DS beige 4.2/00 ) RK 2,5-4 DS blue 4.5/00 ) 32 40 40 4 22-0 0,2-6 - 0,2-6 0,2-6 2 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 TRS 2003.2/00 20.0/50 240.2/50 2020.0/50 24.2/50 202.0/20 242.2/20 Q 0 2022.0/0 QI 0 243.2/0 086.0/ 3) with connector socket 48 x 6 x 4 RK 2,5-4/35 beige 5.2/00 RK 2,5-4/35 blue 5.5/00 32 32 32 4 22-0 0,2-6 - 0,2-6 0,2-6 2 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 TRS 2003.2/00 20.0/50 240.2/50 2020.0/50 24.2/50 202.0/20 242.2/20 Q 0 2022.0/0 QI 0 243.2/0 086.0/
RK 6-0 RK 6-0/35 RK 6 RK 6/35 N RK 35 RK 35/35 N M 4 M 4 M 5 M 5 M 6 M 6 48 x 8 x 5,5 48 x 8 x 4 48 x 8 x 4 50 x 2 x 63 50 x 2 x 58,5 54 x 2 x 4 58 x 6 x 6 58 x 6 x,5 58 x 6 x 52 RK 6-0 beige 005.2/00 RK 6-0 blue 005.5/00 RK 6-0 DS beige 8.2/00 ) RK 6-0 DS blue 8.5/00 ) * 0 22-6 A5 V2 RK 6-0/35 beige 58.2/00 RK 6-0/35 blue 58.5/00 0 22-8 A5 V2 RK 6 beige 050.2/50 RK 6 blue 050.5/50 RK 6/IS beige 42.2/50 4) RK 6/IS blue 42.5/50 4) RK 6/Z beige 62.2/50 5) RK 6/Z blue 62.5/50 5) RK 6/Z-IS beige 43.2/50 4)5) RK 6/Z-IS blue 43.5/50 4)5) IEC UL* CSA 6 85 85 6 0-4 B V2 RK 6/35 N beige 5.2/50 RK 6/35 N blue 5.5/50 RK 6/35 N/Z beige 53.2/50 5) RK 6/35 N/Z blue 53.5/50 5) 6 85 85 6 2-4 B V2 RK 35 beige 052.2/20 RK 35 blue 052.5/20 RK 35/IS beige 44.2/20 4) RK 35/IS blue 44.5/20 4) RK 35/Z beige 63.2/20 5) RK 35/Z blue 63.5/20 5) RK 35/Z-IS beige 45.2/20 4)5) RK 35/Z-IS blue 45.5/20 4)5) 25 0 5 35 2-2 B V2 RK 35/35 N beige 52.2/20 RK 35/35 N blue 52.5/20 RK 35/35 N/Z beige 54.2/20 5) RK 35/35 N/Z blue 54.5/20 5) 25 0 5 35 2-2 B V2 0,2-0 0,2-0 0,2-0 0,2-0 0,2-0 2 0,2-0 0,2-0 0,2-0 0,2-0 0,2-0 2,5-6 2,5-25 2,5-6 2,5-6 2,5-25 5 2,5-6 2,5-25 2,5-6 2,5-6 2,5-25 5 2,5-6 2,5-35 2,5-35 2,5-35 2,5-35 20 2,5-6 2,5-35 2,5-35 2,5-35 2,5-35 20 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 TRS 2003.2/00 2060.0/50 250.2/50 206.0/50 25.2/50 2062.0/20 252.2/20 Q 0 2063.0/0 QI 0 253.2/0 AP 2,5-0 200.2/50 200.5/50 TW 2,5-0 TRS 2003.2/00 2060.0/50 250.2/50 206.0/50 25.2/50 2062.0/20 252.2/20 Q 0 2063.0/0 QI 0 253.2/0 AP 6 204.2/50 204.5/50 TW 6 205.2/50 205.5/50 22./20 23.0/20 24.0/0 Q 0 25.0/0 225.0/20 2258.0/20 2265.0/0 Q 0 2266.0/0 AP 35 26.2/20 26.5/20 TW 35 2.2/20 2.5/20 264.0/20 265.0/20 266.0/0 Q 0 26.0/0 264.0/20 265.0/20 266.0/0 Q 0 26.0/0 08.0/ 08.0/ 08.0/ 08.0/ SDB,2 x 6,5 088.0/ SDB,2 x 6,5 088.0/ ) cross connection not possible 4) with hexagon socket screw 5) with housing pins
s Screw connection system RK 50 RK 5 RK 50 RK 240 Rail mount on TS 32 / TS 35 M 6 M 8 M 0 M 0 Connection diagram Connection type Dimension (L x W x H) with TS 32 mm with TS 35 x,5 mm Gauge plug acc. to EN 60 4- / Flammability class UL 4 For certifications and approvals Flexible/Flexible (with ADH acc. to DIN 46 228/) mm 2 Contact wire range mm 2 Features Number of cross connection channels Test pick-off feature Accessories Outer insulated cross connector A poles Outer insulated cross connector A poles Cover AD Inlay profile EP Hexagon socket screw key ISKS Pick off terminal MAG 8 x 20 x 82 x 20 x 6,5 RK 50 beige 20.2/0 RK 50 blue 20.5/0 000 600 600 50 50 50 50 /0-6 B0 V2 0-6 6-50 6-50 6-50 0-50 2 A/50 263.2/5 A/50 264.2/5 AD /50 280.0/20 224.0/0 ISKS 5 288.0/ MAG 50 2.2/0 84 x 25 x 4 84 x 25 x 88,5 RK 5 beige 22.2/0 RK 5 blue 22.5/0 000 600 600 232 230 230 5 4/0-2 B2 V2-35-5 50-5 50-5 35-5 30 A/5 265.2/5 A/5 266.2/5 AD /5 2804.0/20 EP 5 225.0/0 ISKS 6 22.0/ MAG 5 23.2/0 3 x 3 x 8,5 3 x 3 x 2,8 RK 50 beige 24.2/5 RK 50 blue 24.5/5 000 600 600 30 25 25 50 300-2 B4 V2-25-50 35-50 35-50 25-50 38 A/50 26.2/5 A/50 268.2/5 AD /50 2806.0/20 22.0/0 ISKS 8 23.0/ MAG 50/240 25.2/0 3 x 36 x 32 3 x 36 x 26,3 RK 240 beige 26.2/5 RK 240 blue 26.5/5 000 600 600 380 30 30 240 500-2/0 B6 V2-50-240 0-240 0-240 50-240 38 A/240 26.2/5 A/240 20.2/5 AD /240 2808.0/20 EP 240 2360.0/0 ISKS 8 23.0/ MAG 50/240 25.2/0 Further accessories Further accessories like marking systems, test adapters, covers, end brackets etc. you can find on the pages for accessories specified below! * Applies 8
Feed-Through Terminal Accessories RK 50 to RK 240 The terminal blocks RK 50 to RK 240 consist of a double shell insulating terminal carrier and due to the special construction of the strain-relief clamp, offer low transitional resistance between the conductor and the contact rail. A broad accessory programme effectively completes this series. Measurement Pick-Up Terminals MAG MAG measurement pick-up terminals allow the voltage to be picked up on terminal blocks with a larger cross sections by conductors with smaller cross sections from 0.2 to 0 mm 2. MAG connection elements are introduced into the respective terminal block above the mains lead-in and make contact with the contact rail through the connection screw of the main terminal block. This ingenious and safe technical solution simplifies wiring considerably. Measurement Pick-Up Terminals MAG MAG 50 MAG 5 MAG 50/240 Gauge plug acc. to EN 60 4- / Flammability class UL 4 Flexible/Flexible (with ADH acc. to DIN 46 228/) mm 2 For terminal MAG 50 2.2/0 IEC UL* CSA* 000 600 600 0/22-6 6 3 A5/V2 0,2-0 0,2-0 0,2-0 0,2-0 2 RK 50 MAG 5 23.2/0 IEC UL* CSA* 000 600 600 0/22-6 6 3 A5/V2 0,2-0 0,2-0 0,2-0 0,2-0 2 RK 5 MAG 50/240 25.2/0 IEC UL* CSA* 000 600 600 0/22-6 6 3 A5/V2 0,2-0 0,2-0 0,2-0 0,2-0 2 RK 50, RK 240 Insertion Plates EP When connecting band conductors, it is necessary to put insertion plates in the strain-relief clamps. The EPs compensate for the V-form geometry in the strain-relief clamps (terminal cage). This also affords the band conductor a safe and dependable connection. Insertion Plates EP EP 5 EP 240 For terminal 224.0/0 RK 50 EP 5 225.0/0 RK 5 22.0/0 RK 50 EP 240 2360.0/0 RK 240