IQ SENSOR NET MIQ/MC(-A)-RS

Similar documents
CarboVis 700/1 IQ TS CarboVis 700/5 IQ TS MIQ/VIS

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

maxon document number:

Precision and high repeat accuracy for individual parts and small series manufacture. Made in Germany.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Concept of Serial Communication

E205 Long Range Wireless Modem V1.0 Data Sheet

External brake resistor AX2090-BW5x

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

M7 Over-The-Air Protocol. Overview. Technical Brief AN187 Rev A1

High power radio transmission module MR03 type

SICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21

OEM PRODUCTS WIRELESS WORLD LOCAL SOLUTION

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

CONTROL MICROSYSTEMS SCADAWave Radio Transceiver. Hardware Manual

ECOS SRIF Operating Instructions

Positioning Controller. Cable Starting Set. Document ID: rel5889

Instruction manual ADN-W AM. Antenna Module

Radio System Strobe Wizard Plus Freemask

RM868500D. Introduction. Features. 868MHz 500mW RS232 / RS485 / RS422 Radio Modem. Operating Manual English 1.01

Positioning Controller. Cable Starting Set. Document ID: rel6742

Positioning Controller. Cable Starting Set. Document ID: rel5883

MGE TM Galaxy TM , 60 Hz kva

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

PRODUCT MANUAL VHF & UHF Pocket Paging Transmitter. Version 1.00 April 2017

Positioning Controller. Cable Starting Set. Document ID: rel5183

Electrical devices may only be mounted and connected by electrically skilled persons.

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

Берг АБ Тел. (495) , факс (495) Initial operation and diagnosis

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

Kit Kit. GeoSteer GS-900 Radio Kit. GS-900 Radio Kit Installation Instructions Rev A

Cable and Port Specifications

USER MANUAL SATEL i-link I/O-converter Version 1.6

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

Model 9302 Amplifier-Discriminator Operating and Service Manual

Astra-R Kit Wireless Alarm System Operation Manual

Optical laser distance sensors. Dimensioned drawing

Revision WI.232FHSS-25-FCC-R and RK-WI.232FHSS-25-FCC-R USER S MANUAL

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

IF30. User's manual. Description. Table of contents IF30

OSMAC RDR Low-voltage Retrofit Kit

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

Installation Manual ID ISCM01-A/B System delivery contents:

Operating manual. NitraLyt Plus 700 IQ. IQ SENSOR NET Modular sensor for nitrate

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

FPS. FPS Flexible Position Sensor. Function description. Your advantages and benefits

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

ACT-IR220Li/220LN IrDA Serial Port Adapter

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

RUDAT The Big Deal. Applications

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Trillium US Inc. E500 Dual Channel Temperature Monitor User s Manual Rev A / November 2015

SI-JET Series SI-JET3-CON8 A-LAS-M C A-LAS-M C. Design. SI-JET Series Spray Jet Control Sensors. Product name:

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

ACT-IR220L/LE IrDA Serial Port Adapter

INVERTER INSTRUCTION MANUAL. 16 bit digital input function. Plug-in option FR-A7AX PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING

Operating manual GTL 241 GTL 251. Temperature probe. Please keep the manual for future use.

RMO500 M I C R O O H M M E T E R

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Analog amplifier RA. RE Edition: Replaces:

HURRICANE Radio Modem. FULL DUPLEX Radio MODEM

MV110-8AS. Analog input module 8 channel. User guide

Preliminary. DN-900 Series. 900 MHz Wireless Serial Modems

Radio Data Modem MOD 02

USB/RS232 Variable Attenuator

OPERATING MANUAL. ba15358e03 09/2014 F 500 DIN, F 500 BNC F 800 DIN, F 800 BNC FLUORIDE SENSITIVE ELECTRODE

Manual IF2008A IF2008E

QUICK GUIDE for multiguard Light. Installation

GPS-Base. GPS Base Station. User Manual. Confidently. Accurately.

IQ TM Spread Spectrum (SS) Radio

JUMO Wtrans Receiver with Wireless Data Transmission

Fast Diode Current Modulator FM 10 Part Number Operating Manual

Model 9305 Fast Preamplifier Operating and Service Manual

Magnetic Inductive Flow Sensor induq

Radio receiver. Instructions for Use. for the reception of a flush actuation via radio signal. en_int

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

HL 675 Data / Impulse Transmitter set User Manual

MU110-16R(K) Digital output module 16 channel. User guide

Preliminary. RF Data Transmission Rates 38.4, 115.2, 200 and 500 kbps

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

Junction Box JB6101- (000) Installation and Operation. Manual DV Issue 1 June 2012

VECTOR INVERTER -INSTRUCTION MANUAL- 16-BIT DIGITAL INPUT FR-V5AH

VTMS. Valve Train Measurement Solution. Data sheet

WATERFLUX 3000 Quick Start

1 What s in the shipping package?

Out 1 sin / cos 1Vpp. sin / cos 1Vpp. Out 3. sin / cos 1Vpp. Out 4 sin / cos 1Vpp. Interface type SV211 SinCos signal splitter with 4 SinCos outputs

Multi radio connection MFA

Fast Diode Current Modulators FM Operating Manual

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

Lecture #3 RS232 & 485 protocols

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

PZ292EN 9/28/2018. User Manual P PIREST ACTIVE SHIM

EVID Surface Mount S Series - X Models

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Transcription:

ESC OK! OK Operating Manual IQ SENSOR NET MIQ/MC(-A)-RS Power C M S Modem Radio Remote connection to the IQ SENSOR NET System 2020 XT via - fixed line telephone network - mobile network - radio link ba64121e03 06/2005

Accuracy when going to press The use of advanced technology and the high quality standard of our instruments are the result of continuous development. Consequently, this may result in some differences between this operating manual and your instrument. Also, we cannot guarantee that there are absolutely no errors in this manual. Therefore, we are sure you will understand that we cannot accept any legal claims resulting from the data, figures or descriptions. Copyright Weilheim 2005, WTW GmbH Reprinting - even as excerpts - is only allowed with the explicit written authorization of WTW GmbH, Weilheim. Printed in Germany.

Remote connection to the IQ SENSOR NET System 2020 XT Contents Remote connection to the IQ SENSOR NET System 2020 XT 1 Overview..................................5 1.1 How to use this component operating manual......... 5 1.2 Remote connection to the IQ SENSOR NET System 2020 XT................................ 6 2 Safety instructions..........................8 3 Scope of delivery............................9 4 Setting up the modem connection.............9 4.1 General structure of a modem link.................. 9 4.1.1 Data link with analog or GSM modems....... 10 4.1.2 Data link with radio modems............... 10 4.2 System requirements........................... 12 4.2.1 Modem system requirements.............. 12 4.2.2 IQ SENSOR NETsystem requirements........ 12 4.2.3 PC system requirements.................. 13 4.3 Commissioning................................ 13 4.4 Modem settings............................... 16 4.4.1 GSM modem........................... 16 4.4.2 Radio modem.......................... 17 5 What to do if................................18 6 Technical data.............................20 6.1 IQ SENSOR NET component, MIQ/MC(-A)-RS........ 20 ba64121e03 06/2005 3

Contents Remote connection to the IQ SENSOR NET System 2020 XT 4 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Overview 1 Overview 1.1 How to use this component operating manual The present operating manual complements the system operating manual for the IQ SENSOR NET system 2020 XT. It contains the description of the RS option of the MIQ/MC(-A)-RS controller. File this operating manual directly behind the system operating manual. Structure of the IQ SENSOR NET operating manual IQ Sensor Net Operating Manual System Operating Manual (Ring Binder) IQ Sensor Operating Manual MIQ Module Operating Manual MIQ Terminal Operating Manual Component Operating Manuals Fig. 1-1 Structure of the IQ SENSOR NET operating manual The IQ SENSOR NET operating manual has a modular structure like the IQ SENSOR NET system itself. It consists of the system operating manual and the operating manuals of all the components used. The space in the ring binder behind the system operating manual is intended for filing the component operating manuals. Please file all component operating manuals here so that all information is quickly available in one location. ba64121e03 06/2005 5

Overview Remote connection to the IQ SENSOR NET System 2020 XT 1.2 Remote connection to the IQ SENSOR NET System 2020 XT General characteristics Connection options via mobile network, fixed line network and radio link The MIQ/MC(-A)-RS controller expands the IQ SENSOR NET by an interface for a modem. This enables a modem connection between the IQ SENSOR NET and a remote PC. In environments without any fixed line telephone network, the IQ SENSOR NET can be connected to the mobile network via a GSM modem or a direct radio link. IQ SENSOR NET (MIQ/MC(-A)-RS) <-> analog modem <-> fixed line telephone network <-> analog modem <-> PC IQ SENSOR NET (MIQ/MC(-A)-RS) <-> analog modem <-> fixed line telephone network <-> mobile network <-> GSM modem <-> PC IQ SENSOR NET (MIQ/MC(-A)-RS) <-> GSM modem <-> mobile network <-> fixed line telephone network <-> analog modem <-> PC IQ SENSOR NET (MIQ/MC(-A)-RS) <-> GSM modem <-> mobile network <-> GSM modem <-> PC IQ SENSOR NET (MIQ/MC(-A)-RS) <-> radio modem <-> air <-> radio modem <-> PC PLC Profibus Modem Radio PC + Software Pack PC + Software Terminal Terminal Option Option -PR -RS Controller Interface RS 232 IQ Sensor Net IQ Sensor Valve module Outputs Power supply for sensor cleaning Fig. 1-2 Functional units of the IQ SENSOR NET with modem connection 6 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Overview With the aid of the IQ SENSOR NET software pack, for example, the following functions can be carried out on a remote PC: (Remote) Operation/monitoring of the IQ SENSOR NET with the MIQ/ T2020 PC software terminal. The software terminal has the same operating concept as other terminal components (e.g. MIQ/T2020). This means it is hardly necessary to "get used" to it when changing between the different types of terminal. (Remote) Data transmission of current measured data (Remote) Data transmission of stored measured data (Remote) Backup/loading of the IQ SENSOR NET system configuration A modem connection via the MIQ/T2020 PC software terminal counts as a terminal component. A maximum of three terminal components can be used in the IQ SENSOR NET at the same time. Only one modem connection can ever be made to the IQ SENSOR NET. Details of the operation of the software are given in the operating manual for the IQ SENSOR NET software pack. All other general information on components, functions and operation of the IQ SENSOR NET 2020 system is given in the system operating manual. ba64121e03 06/2005 7

Safety instructions Remote connection to the IQ SENSOR NET System 2020 XT 2 Safety instructions Essential instructions that must be followed during the commissioning, operation and maintenance of the IQ SENSOR NET system are given in the system operating manual. It is essential for the operator to read this system operating manual before carrying out any work with the system. General safety instructions The following safety labels in the individual chapters of this operating manual indicate different levels of danger: Warning indicates instructions that must be followed precisely in order to prevent serious dangers to personnel. Caution indicates instructions that must be followed precisely in order to avoid slight injuries to personnel or damage to the instrument or the environment. Other labels indicates notes that draw your attention to special features. indicates cross-references to other documents, e.g. component operating manuals. 8 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Scope of delivery 3 Scope of delivery In addition to the scope of delivery of the MIQ/MC(-A), the scope of delivery of the MIQ/MC(-A)-RS module contains: MIQ/MC(-A)-RS controller with mounted interface for a modem Operating manual for the modem option (-RS) IQ SENSOR NET Software Pack 4 Setting up the modem connection A (remote) data link can be established between the IQ SENSOR NET and the PC using the following modem types: Analog modem or GSM modem (see section 4.4.1) Radio modem (see section 4.4.2) 4.1 General structure of a modem link For any modem link between the IQ SENSOR NET and the PC, two modems are required: one modem on the IQ SENSOR NET side and one modem on the PC side. ba64121e03 06/2005 9

ESC OK! OK Setting up the modem connection Remote connection to the IQ SENSOR NET System 2020 XT 4.1.1 Data link with analog or GSM modems A data link using analog modems or GSM modems can be established with different modem combinations (analog modem and GSM modem) (see section 1.2). Fig. 4-1 (Remote) Data transmission with analog modems or GSM modems 4.1.2 Data link with radio modems A data link using radio modems must be made with two identical modems. Radio modem Radio modem Power Air C M S Power supply Power supply Fig. 4-2 (Remote) Data transmission with radio modems 10 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Setting up the modem connection The following factors have an impact on the radio link: Distance between sender and receiver Natural barriers between sender and receiver Sender power Sensitivity of the radio receiver Amplification power of the sending and receiving aerial Attenuation of the aerial cable Mounting height of the aerial Other interferences Further information and the suitable equipment in order to establish an optimum radio link is available from your specialist dealer. When establishing a radio link also observe the relevant national legal requirements, concerning e. g.: Restrictions when using a radio frequency and the possibly necessary purchase of a license for the use of a radio frequency. In Germany, the regulatory authority for telecommunication and mail (Regulierungsbehörde für Telekommunikation und Post - RegTP) is responsible for the national legal requirements. ba64121e03 06/2005 11

Setting up the modem connection Remote connection to the IQ SENSOR NET System 2020 XT 4.2 System requirements 4.2.1 Modem system requirements The modems must meet the following requirements: Analog modem Compatible to the Hayes (AT) standard serial RS232 interface (for modem on IQ SENSOR NET side) power supply unit, cable for data transmission analog telephone mainline with telephone number (for modem on IQ SENSOR NET side) Recommendations: IQ SENSOR NET side: devolo MicroLink 56k i PC side: devolo MicroLink 56k ior Creatix V.90 GSM modem Compatible with the AT command set according to the GSM 07.07 specification serial RS232 interface (for modem on IQ SENSOR NET side) power supply unit, aerial, cable for data transmission country-specific mobile network (in Germany: D1 or D2) Recommendation: Siemens TC35i or Siemens MC35i Radio modem Transparent data transmission serial RS232 interface power supply unit, aerial, cable for data transmission and line power connection data transmission rate of the radio link: min. 9600 bits/s Recommendation: Radio modems by Satel (Satelline product series) with cable set for data transmission and line power connection (www.satel.fi) 4.2.2 IQ SENSOR NETsystem requirements MIQ/MC(-A)-RS controller operable modem (see section 4.2.1) IQ SENSOR NET - modem connection cable Prepare this connection cable yourself, e.g. using a 6-wire cable and an RS232 plug (see section 4.3). 12 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Setting up the modem connection 4.2.3 PC system requirements Hardware requirements AT-compatible computer with Pentium processor or higher (recommended: 500 MHz or higher) minimum 8 MByte RAM (recommended: 64 MByte or higher) Hard disk with at least 10 Mbytes available memory VGA/SVGA graphic card with monitor CD-ROM drive Connection cable (PC <--> modem) operable modem (see section 4.2.1) The use of an external modem with USB or RS232 interface is preferable. In the case of internal notebook modems, problems with the transmission speed can occur. If you use radio modems, use two identical modems. Software requirements Windows 95 or higher IQ SENSOR NET Software Pack 4.3 Commissioning Preparing the connection cable The following preparations on the side of the IQ SENSOR NET are required for the commissioning of the -RS modem option of the MIQ/MC(-A)-RS controller: Materials required shielded 6-wire cable (maximum length: 10 m) 9-pole D-Sub female connector (RS232) for the connection of individual wires 6 wire end sleeves Connecting the cable to the plug 1 Strip the wires on one end of the connection cable. 2 Connect 6 wires of the cable to the pins of the 9-pole D-Sub male connector according to the pin assignment. ba64121e03 06/2005 13

Setting up the modem connection Remote connection to the IQ SENSOR NET System 2020 XT Terminal assignment The pins on the IQ SENSOR NET must be connected to the pins of the modem plug. The pin assignment of your modem is given in the operating manual of your modem. Example Pin assignment on the IQ SENSOR NET with allocation to a 9-pole D-Sub male connector (RS232). Pin IQS * Name Function Pin D ** 1 RxD Received Data 2 2 TxD Transmitted Data 3 3 GND R232 Signal ground 5 4 RTS & DTR Request to Send & Data Terminal Ready (2 wires --> 1 terminal) 7 4 5 CTS Clear to Send 8 *) Pin assignment for terminal connection on the IQ SENSOR NET **)Pin assignment for a 9-pole D-Sub plug connection (RS232) 3 Cut off the excess wires. 4 Connect the cable shield to the plug enclosure. 5 Connect the plug. Preparing the connection cable for connection to the MIQ/MC(-A)-RS 6 Carefully remove the connection cable insulation for approx. 15 mm. 7 Cut off the excess wires. 8 Strip the insulation of the wires of the connection cable on the side of the MIQ/MC(-A)-RS for a length of approx. 5 mm. 9 Twist the wires of the connection cable and slide on wire end sleeves. 14 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Setting up the modem connection Fig. 4-3 Connection cable with RS232 plug Connecting the connection cable to the MIQ/MC(-A)-RS 1 Screw the MIQ/MC(-A)-RS module open. 2 Connect the wires of the connection cable to the terminal connections of the modem connection according to the terminal assignment. 12345 Fig. 4-4 MIQ/MC(-A)-RS with terminal connection for a modem Terminal assignment Pin Name Function 1 RxD Received Data 2 TxD Transmitted Data 3 GND R232 Signal ground 4 RTS & DTR Request to Send & Data Terminal Ready (connect both wires to this terminal) 5 CTS Clear to Send ba64121e03 06/2005 15

Setting up the modem connection Remote connection to the IQ SENSOR NET System 2020 XT 3 Check the entire cable connection from the terminal strip up to the pins of the D-Sub male connector. 4 Screw the MIQ/MC(-A)-RS module shut. 5 Connect the connection cable to the modem. 6 Prepare the modem for operation according to the operating manual. 7 Attach the power supply for the IQ SENSOR NET according to the system operating manual. 8 Connect the power supply for the modem according to the operating manual of the modem. Thus, the IQ SENSOR NET is ready for communication via a modem. Preparing the PC for the modem connection The following preparations for a modem connection with the IQ SENSOR NET are required on the PC: 9 Connect a modem to the PC (see operating manual of the modem). 10 Install the IQ SENSOR NET software pack on the PC (see operating manual of the IQ SENSOR NET software pack). 4.4 Modem settings 4.4.1 GSM modem To enable a connection to the IQ SENSOR NET, the PIN of the modem SIM card has to be changed to 0365. The PIN can be changed using a mobile phone or with the aid of a PC and the GSM modem. To change the PIN via the PC and GSM modem, you need an RS232 interface cable and a terminal program (e.g. Hyperterminal under Windows). To do so, proceed as follows: 1 Connect the GSM modem to the PC via the interface cable. 2 Start the terminal program and establish a connection to the modem. 3 Enter the command, AT+CPWD=SC,xxxx,0365 (xxxx is for the old PIN, 0365 is the new PIN). The modem should reply with OK. With this, the PIN is set to 0365. 16 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT Setting up the modem connection 4.4.2 Radio modem For the data transmission between two radio modems to be error free, both radio modems (on the IQ SENSOR NET side and on the PC side) must be configured in the same way. Details on the configuration of your radio modem are given in the operating manual of your radio modem. Some settings have to be done on the radio modem. All settings must be identical with both modems. The settings given as an example have to be adjusted accordingly. Settings on the radio modem Data transmission speed of the serial interface: Start delay: Transmitting power: The required transmitting power depends e.g. on the local conditions. Transmitting frequency: Certain national transmitting frequencies are allocated to individual transmitting powers. 38400 bits/s 0 ms e.g. 500 mw e.g. range 869.400-869.650 MHz For the operation of radio links, the national regulations and conditions for the use of radio frequencies always have to be observed. Possible restrictions when using a radio frequency: Transmitting power Duty Cycle Channel band width (affects the transmission speed) Licenses Information on recommended radio modems (Satelline product series) and further accessories (cable for power supply and data transmission) is available from Satel or on the Internet under www.satel.fi. ba64121e03 06/2005 17

What to do if... Remote connection to the IQ SENSOR NET System 2020 XT 5 What to do if... Errors of analog modems or GSM modems caused by the modem or country-specific features concerning the entry of the telephone number are not taken into account here. Connection to the IQ SENSOR NET is not established Cause Telephone number entered incorrectly or incompletely (analog modem or GSM modem) Faulty devices, e.g. Modems MIQ/MC(-A)-RS Remedy Check telephone number Pay attention to special country-specific features during modem operation Pay attention to special features during operation on telephone systems Replace devices Connection to the IQ SENSOR NET is faulty Cause Wiring of the connections is faulty Modem interface of the MIQ/MC(-A)-RS defective Remedy Check/correct the wiring of the connections to the terminal strip Send the MIQ/MC(-A)-RS to WTW Cable is faulty Check the cable Modem defective Replace the modem COM connection of the PC incorrectly configured Activate the FIFO buffer (if possible) Set the receive buffer to the highest value (if possible) 18 ba64121e03 06/2005

Remote connection to the IQ SENSOR NET System 2020 XT What to do if... Cause Transmission quality insufficient (radio modem) Malfunction due to other transmitters (radio modem) Remedy Distance between radio modems too great Transmitting power too low Aerial insufficient or defective Weather impact Further notes can be found in the operating manual of your radio modem. select other frequency Connection is disconnected Cause Line quality insufficient (analog modem or GSM modem) Remedy Redial Check the telephone connections on the side of the IQ SENSOR NET on the side of the PC Test the transmission speed by means of a data transmission with a PC on the side of the IQ SENSOR NET Modem unsuitable Check the suitability of the modem (to do so, contact your dealer) ba64121e03 06/2005 19

Technical data Remote connection to the IQ SENSOR NET System 2020 XT 6 Technical data 6.1 IQ SENSOR NET component, MIQ/MC(-A)-RS General technical data for the IQ SENSOR NET and the MIQ/MC component are given in the system operating manual of the 2020 XT system. The general technical data of the MIQ/MC(-A)-RS controller are the same as the technical data of the MIQ/MC controller. The MIQ/MC(-A)-RS controller additionally contains a modem interface (M) with a clamping connection for a modem. (M) 12345 Fig. 6-1 Module with clamping connection for a modem The assignment of the terminal is given in section 4.3. 20 ba64121e03 06/2005