BBD7267 Version 1 PRIEVIEW COPY ONLY

Similar documents
TECHNICAL SPECIFICATION FOR. CONTACT WIRE HARD-DRAWN COPPER 161mm2

MESP TECHNICAL SPECIFICATION FOR BARE FLEXIBLE ANNEALED COPPER JUMPER WIRE 37/7/ mm 2

MESP TECHNICAL SPECIFICATION FOR TRANSMISSION WIRE HARD-DRAWN COPPER 19/ mm 2

MESP TECHNICAL SPECIFICATION FOR FLEXIBLE DROPPER WIRE TIN-BEARING COPPER 7/7/ mm 2

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

MESP TECHNICAL SPECIFICATION FOR CATENARY WIRE HARD-DRAWN COPPER 37/ mm 2

MESP TECHNICAL SPECIFICATION FOR MURL JUMPER WIRE HARD-DRAWN COPPER 19/ mm 2

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

SECTION-I (G.I.PLAIN WIRE) TECHNICAL SPECIFICATION FOR G. I. WIRE

POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.

TECHNICAL SPECIFICATION FOR G. I. WIRE (4MM)

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Cable Type 125. CAI Certification Specification

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Cable Type 100. CAI Certification Specification

TECHNICAL SPECIFICATION FOR G.I. WIRE AND G.I. STAY WIRE

FORM Q-120 PROCEDURE SPECIFICATION FOR CLASS II VESSELS (Revision C 2017) Part I Fabrication

conductor Extruded Cross - Linked Polyethylene Insulated (XLPE) Power Cable Rated Voltage U 0 /U = 12/20 kv U 0 /U = 18/30 kv

DRAFT UGANDA STANDARD

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

015 : 1993 CEB STANDARD

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Eurocode EN Eurocode 3: 3 Design of steel structures. Part 1-1: General rules and rules for buildings

TECHNICAL REPORT RAW MATERIALS SINGLE METAL SHEET SECTIONAL DOOR

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

Materials. Density, Hooke's law, Young modulus. 174 minutes. 174 marks. Page 1 of 29

CARES Technical Approval Report TA1-B 5042

ISRAEL RAILWAYS LTD. INFRASTRUCTURE DIVISION TRACK AND RIGHT OF WAY DEPARTMENT. for

NPS/001/010 Technical Specification for Fasteners and Fixings for Wood Pole Overhead Lines and General Construction Works

NPS/002/003 Technical Specification for Protection Tile, Protection Tape, Cable Ducting and Route Markers

M-RAIL Sismet Road, Mississauga, L4W 1V6 TEST REPORT FOR MLEVEL GUARD SYSTEMS

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

Securifor Polyester Coated Welded Mesh Panels

SBCA Industry Standards Subcommittee. Specification for 75 Ω Flexible RF Coaxial Drop Cable for Direct Broadcast Satellite (DBS) Installations

Technical Specification. for 1.1 KV Copper Control Cable

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

Instruction Manual for installing

Instruction Manual for installing

001: 2007 CEB STANDARD

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB

Handling Precaution for Terminal and Connector

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Steel wire for general fencing purposes

Freestanding Guardrail System. Operation & Maintenance Manual

ISO INTERNATIONAL STANDARD. Welding Studs and ceramic ferrules for arc stud welding

H07RN-F BS EN Flexible Rubber Cable

MEFA mounting accessories

Alfa Laval Material Standard T

Proposal for new standard. Determination of interface friction between painted parts. Orientation. p. 1 (15) Draft1, Revised

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Electric cables. Cranes

Design Guide. Original version of the design guide

Technical Memorandum

Standard Specification for Copper-Clad Steel Wire for Electronic Application 1

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

Company 'A' Wind Turbine Safety Rules (3 rd Edition) Support Procedure P2 PROCEDURE FOR APPROVAL OF TOOLS, EQUIPMENT AND PROCESSES

DESIGN OF MACHINE MEMBERS-I

INTERNATIONAL STANDARD

REPORT OF PERFORMANCE TIC

FreeSpace DS 16F VA TECHNICAL DATA SHEET. loudspeaker. Key Features. Product Overview. Technical Specifications

PRECISELY CONTROLLED STRIP TENSION. The key to success in innovative production processes PERFECT STRIP FLATNESS TOP-QUALITY SURFACE

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Reinforcing Mesh Product Guide

bolts: G Cr-1/5Mo (A193 B7) 16 x M20 (EN ISO 4014) MPR GASKET 'SP' PETRO 4,0mm 363 x 323 x 4,5 mm (2 pieces)

DNVGL-CP-0400 Edition December 2015

MOY/SCMI/60 SPECIFICATION OF ACCURACY FOR VEE PIECES FOR EXTERNAL SCREW THREAD MEASUREMENT

THE KENYA POWER AND LIGHTING CO. LTD. SPECIFICATIONS for IMPULSE VOLTAGE TEST EQUIPMENT

SPECIFICATION FOR SAFETY POLE SIGNS & ACCESSORIES

Engineering Policy & Procedure

This Manual Part recommends design criteria for resistors suitable for railway signaling circuits other than electronic.

MATERIAL AND EQUIPMENT STANDARD FOR METRIC TYPE FASTENERS (SCREWS, BOLTS, STUDS, NUTS AND WASHERS) ORIGINAL EDITION DEC. 1997

TCN 01. Page No. 1 of 2 Ref: PSER:SCT:ABJ:T1178:TCN-01 Date:

CAT 5e UTP Cable: NETSET BOX [305m], indoor

CH # 8. Two rectangular metal pieces, the aim is to join them

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Specification for pvc-insulated cables for electricity supply

Testing Manual for Electrical Equipment

NUMBER SOP STANDARD POLICIES AND PRACTICES PAGE 1 OF 4. April 15, 2012 STANDARDIZED PART MARKING PRACTICES REVISES POLICY DATED: July 1, 2010

Z January 2017

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Metric sine bars and sine tables (excluding compound tables)

ASSEMBLY TOOLS FOR SCREWS & NUTS. Part 1: Insulated hand operated socket drive wrenches and screw drivers

Design Guide. Original version of the design guide

INCH-POUND. MIL-DTL June 2008 DETAIL SPECIFICATION WIRE ROPE, 1.5 INCH DIAMETER, GALVANIZED, COMPACTED STRAND, FOR AIRCRAFT ELEVATOR

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Ordering example: WSK-600 / B x H x L = 155 mm. M8 hexagon head screw, fixed by a locknut. Threaded bolt

Fluid Sealing Association

ABOUT US ABOUT US 1 CRANE CABLES

Test Report. Test Report Smart Systems Limited incorporating Smart Extrusions. Page 1 of 58

079 : 2000 CEB STANDARD ALUMINIUM BINDING WIRE

(1) Brass, an alloy of copper and zinc, consists of 70% by volume of copper and 30% by volume of zinc.

European Technical Assessment ETA-17/1005 of

Transcription:

INDEX SECTION CONTENTS PAGE 1.0 SCOPE 3 2.0 REFERENCES 3 3.0 APPENDICES 3 4.0 METHOD OF TENDERING 3 5.0 MATERIAL 3 6.0 MARKING 3 7.0 SIZE AND LENGTH 4 8.0 DRUMS AND WINDING 4 9.0 MARKING OF DRUMS 4 10.0 INFORMATION 4 11.0 TESTS 4 Page 2 of 9

1.0 SCOPE BBD7267 Version 1 This specification covers Transnet s requirements for the manufacture, testing and supply of grooved, 107mm² or 161mm² copper-magnesium (CuMg0,2) contact wire. 2.0 REFERENCES 2.1 The following specification and drawing are referred to herein: 2.1.1 British Standards Specification: BS EN 50149 : Railway application Fixed installation Electrical traction Copper and copper alloy grooved contact wires 2.1.2 Transnet Drawing: CEE-TW-433 3.0 APPENDICES : Steel Drum for Contact Wire. The following appendices form an integral part of this specification: 3.1 Appendix 1: Cross-sectional profile of the 107mm² or 161mm² contact wire. 3.2 Appendix 2: Special Marking for Identification Purposes. (A) specifies the nature of the imprinting (B) identification grooves, text size and position. 3.3 Appendix 3: Test Results of 107mm 2 Grooved Contact Wire. This appendix specifies the form in which the test results for 107mm 2 grooved copper will be presented in order to check compliance. 3.4 Appendix 4: Test Results of 161mm 2 Grooved Contact Wire. This appendix specifies the form in which the test results for 161mm 2 grooved copper will be presented in order to check compliance. 4.0 METHOD OF TENDERING 4.1 Tenderers shall indicate clause by clause compliance or non-compliance with this specification. This shall take the form of a separate document listing all the specification clause numbers indicating the individual statement of compliance or non-compliance. 4.2 A statement of non-compliance shall be motivated by the tenderer. 4.3 The test results (Appendix 3 and 4) to this specification shall be fully completed by the tenderers. 4.4 Failure to comply to clauses 4.1, 4.2 and 4.3 may preclude a tender from further consideration. 5.0 MATERIAL 5.1 The wire shall be made from high conductivity copper-magnesium CuMg0,2, in accordance with specification BS EN 50149. The configuration and cross-sectional areas are depicted in Appendix 1. 5.2 The wire shall comply with all the properties detailed in Appendix 3 and 4 hereof for 107mm 2 or 161mm ² respectively. 6.0 MARKING 6.1 The wire shall have imprinted on the upper lobe of the wire the words TRANSNET as indicated in Appendix 2(A). 6.2 Copper-magnesium wire shall incorporate three identification grooves on the upper lobe of the wire in accordance with Appendix 2(B). These grooves will identify the copper-alloy in accordance with specification BS EN 50149. Page 3 of 9

7.0 SIZE AND LENGTH BBD7267 Version 1 7.1 The wire shall have a cross sectional area of 107mm 2 or 161mm 2 and shall have dimensions in accordance with Appendix 1. 7.2 The 107mm 2 wire shall be supplied in continuous lengths of 1610meter plus 2m us 0 (zero) and the 161mm² wire shall be supplied in continuous lengths of 1830meter plus 2m us 0 (zero). 8.0 DRUMS AND WINDING 8.1 Each drum shall be manufactured in accordance with Transnet s drawing No. CEE-TW-433 and shall have the wire tightly and evenly wound thereon. 8.2 The inner end of each length shall be marked at a distance of 30m from that end in such a manner as to give an observer, 6m away from the drum, an indication of the approaching end of the length when the wire is being reeled off at the rate of 60m per ute. 8.3 The wire shall be wound on the drum with the vertical axis of the wire at right angles to the axis of the drum and in such a manner that the contact surface of the wire shall be to the bottom when the wire is unreeled of the top of the drum. The wire shall be wound in uniform layers with turns tightly together and free from kinks and crossovers. 8.4 Both ends of the wire must be securely fixed to the drum flange. 9.0 MARKING OF DRUMS 9.1 Each drum shall have, clearly marked on the outer surface of one flange, the following information: The manufacturer s name The size of the wire The total length of the wire contained thereon The gross mass The net mass Transnet's stores order number A suitable sequence number for identification purposes 9.2 Arrows indicating the direction of un-winding, must appear clearly marked on both flanges of the drum. 10.0 INFORMATION Tenderers shall submit with their tenders the following information: 11.0 TESTS * Maximum resistance of the wire to be supplied, (Ω/km at 20 C) * Minimum tensile strength of the wire to be supplied (kn) * Actual number and full details of the type of joints in each length of wire to be supplied 11.1 A sample length of wire from the end of each drum shall be cut off for test purposes. When relevant, one sample length in five shall include a joint. All samples shall be tested to ensure compliance with clauses 5.2 and 7.1 hereof. Whenever samples cut off in terms of the above, includes a joint, the exact location of this joint shall be clearly and positively marked by means of non destructive chemical etching. This is required to ensure that the wire at the joints can be tested for compliance with the requirements of clause 5.2. Page 4 of 9

11.1.1 After removal of a sample length of wire from a drum, the actual length of wire remaining thereon, shall not be less than that called for in clause 7.2. 11.2 Since creep of the contact wire has to be taken into account during erection stages and afterwards during normal maintenance, tenderers must give figures indicating the initial and final creep rate that can be expected. The tensile stress for these creep rates should also be indicated. 11.3 Tests to confirm the compliance of the wire with the technical properties laid down in clause 5.2, shall be carried out on the sample lengths by the manufacturer as detailed in specification BS EN 50149. 11.4 Transnet reserves the right to witness all tests. 11.5 Copies of test certificates giving details of all tests results are to be handed, immediately after the tests, to Transnet, to confirm that the wire and drums meet the electrical and mechanical properties required by this specification. 11.5.1 The test certificates to be supplied to Transnet shall be as shown in Appendix 3 and 4. Page 5 of 9

APPENDIX 1 CROSS-SECTIONAL PROFILES Figure 1: Cross-sectional profile of a 107mm² Contact wire. Figure 2: Cross-sectional profile of a 161mm² Contact wire. Page 6 of 9

SPECIAL MARKING FOR IDENTIFICATION PURPOSES BBD7267 Version 1 APPENDIX 2 (A) TRANSNET TRANSNET TRANSNET TRANSNET TRANSNET TRANSNET (B) TRANSNET TRANSNET TRANSNET TRANSNET In both cases (107mm² and 161mm² contact wire) the height of the text must be as indicated below. 107mm² 161mm² (Illustration not to scale) Identification grooves, Text size and position. Page 7 of 9

APPENDIX 3 TEST RESULTS OF 107mm 2 GROOVED CONTACT WIRE Customer's Name: Customers Order No.: Noal Mass per Area (mm²) Resistance per km @ Tensile strength Drum km (kg) 20 C N/mm² No. 951±3% 107 0.268 max 500 Signed: Elongation on 200 mm (%) 3.0 Twists in 250 mm 5 Reverse Bends 6 Notes Quality Inspector: Date: Testing Authority: Date: Page 8 of 9

APPENDIX 4 TEST RESULTS OF 161mm 2 GROOVED CONTACT WIRE Customer's Name: Customers Order No.: Noal Mass per Drum km (kg) No. 1432 ±3% Signed: Area (mm²) Resistance per km @ 20 C Tensile strength N/mm² 161 0.138 max 420 Elongation on 200 mm (%) 3.0 Twists in 250 mm 5 Reverse Bends 6 Quality Inspector: Date: Notes Testing Authority: Date: Page 9 of 9