Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2

Similar documents
ECG HOLTER INtUItIVe USeR INteRFAce Interactive Graphs Interactive Histograms navigation by extremes Fully Customizable R E LT O H CG E

Galix WinTer. Holter Analyzer

Helping you improve patient care. Welch Allyn Holter Systems

HolterSoft Ultima v2.5 Manual

DM Software. CardioVision Manual. English. Revision Date

IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others

Cutting-edge image quality

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

6. Cloud Database retrieval of ECG reports by Mobile Phone, Tablet, or Notebook.

METRAClip87 and 88 Clamp Multimeters

OPERATOR S MANUAL FOR DMS 300-4A HOLTER ECG RECORDER

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

PIPELINE DEFECT MAPPER

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

POWERFULLY SIMPLE SEEQ. Mobile Cardiac Telemetry System SHORT-TERM CARDIAC MONITORING FOR UP TO 30 DAYS 95 % PATIENT SATISFACTION 1

PCH100 Office Holter Software System. Directions for Use

CP 6632 Handheld process signal calibrator

The First True Color Confocal Scanner

MEASURING INSTRUMENTS AND TESTERS

UNIProbe - TwinProbe

ECG Set. We Simplify the Procedures and You Save Time!

Impressive Wide Field Image Quality with Small Pupil Size

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

Q 3007 Biometric Transponder

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

Maximum power. Nominal voltage. Operating temperature 0 to 50ºC. Humidity without condensation 5 95 % Contamination level 2 Current input features

ASYC IV. METRIX revolutionizes multimeters! The 1 st multimeters with graphical colour screens. ... Plus unrivalled simplicity of use, as always!

Progeny Imaging. User Guide V x and Higher. Part Number: ECN: P1808 REV. F

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Portable Multi-Channel Recorder Model DAS240-BAT

2) APRV detects and records low frequency events (voltage drop, over-voltages, wave distortion) with a sampling frequency of 6400 Hz.

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

The First True-Color Wide-Field Confocal Scanner

PQA823 PQA824 Rel /03/2007

RMO-A series Micro Ohmmeters

The First True Color Confocal Scanner on the Market

6.555 Lab1: The Electrocardiogram

2 PLANMECA. PLANMECA ProSensor. ProSensor

high accuracy tester-calibrator PJ 6301

FLIR Tools for PC 7/21/2016

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD

Three-Phase Transformer Demagnetizer DEM60

SOLAR300N Rel /01/10

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

The experience of the Qualistar ensuring high performance

Advanced Test Equipment Rentals ATEC (2832)

TO.GO 2VA TO.GO 4VA TO.GO 2AS TO.GO 2A TO.GO 2AK TO.GO 4AK TO.GO 2QV TO.GO 4QV TO.GO 4ASE PROGRAMMING GUIDE

Examion. New. Image Acquisition and Diagnostics. R a d i o D i g i t a l e. examion aqs veterinray software.

Operating Manual. Holter. Part 2: Hardware, description of device for custo watch. Operating characteristics: 3-channel ECG, Holter

R-Log Radio data logger

Advanced Test Equipment Rentals ATEC (2832)

SKF TKTI. Thermal Camera Software. Instructions for use

Performance and care. all in one

Technical data ESA614 Electrical Safety Analyzer

OPUS20 Multiple Functions with Internal Sensors

MINIMUM SYSTEM REQUIREMENTS

ExpoM - ELF User Manual

PQA823 PQA824 Rel /09/18

Digital Panoramic X- Ray unit. Product Data

PQA823 PQA824 Rel /01/2007

1 PLANMECA ProSensor. ProSensor Digital Intraoral Systems

UltraTEV Locator Portable Partial Discharge (PD) investigation system.

VMS-4000 Digital Seismograph System - Reference Manual

imagespectrum ADVANCED DIGITAL IMAGE MANAGEMENT SYSTEM Get a Better Handle on the Big Picture

TWA Series Three-Phase Winding Ohmmeters & Tap Changer & Winding Analyzers

AT-5000 Professional Underground Cable / Pipe Locator System

pipeline integrity PCM + Pipeline Current Mapper

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Your heart in good hands.

FAQs. BIOTRONIK EHR DataSync Frequently Asked Questions. Cardiac Rhythm Management. BIOTRONIK Home Monitoring / Programmer

SCATT Biathlon shooting trainer User s Manual

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

DATAMAR 2000 MICROWAVE (26 GHz) RADAR TIDE GAUGE

Selective and broadband low frequency field analysis

CASE STUDY BRIDGE DYNAMIC MONITORING

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

Remote Radio Control. Push Button Transmitters. M880 Radio Control for Tower Cranes

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

For Isotropic Measurement of Magnetic and Electric Fields

DEFIBRILLATOR ANALYZERS

Electroencephalograph EEG-1200J/K

Energy Explorer PROFESSIONAL POWER & HARMONICS ANALYSER

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Indeks: WMXXCMM60 Advanced Industrial Multimeter

VIBXPERT. 2-Channel Vibration Analyzer. 102,400 lines of resolution. Weighs only 2.2 lbs. Simple joystick operation. Signal post processing

Spectrum Analyzer. Spectrum Analyzer. Antenna Panel Inputs. Auxiliary Antenna Inputs. Two models available: 24 GHz and 8 GHz OSCOR

Tap Changer Analyzer & Winding Ohmmeter RMO60TT

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

SC101. Class 1 integrating sound level meter with measurement. Applications Includes measurement protocols for: Noise generated by motor vehicles

Medlab GmbH EG04000 User Manual. medlab. Four Lead ECG OEM board EG Technical Manual. Copyright Medlab Version Version 1.

Ultrasonic level measuring device, non-contact

SIEMOS PQ The Multi-Functional Power Quality Analyzer for Low and Medium-Voltage Networks

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

VivoSense. User Manual - Equivital Import Module. Vivonoetics, Inc. San Diego, CA, USA Tel. (858) , Fax. (248)

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR

The experience of the Qualistar, ensuring high performance

Transcription:

walk400h walk400h walk400h is a latest-generation holter recorder able to acquire and memorise from 3 to 12 ECG channels, compatible with the holter reader software CARDIOLINE, for details of which see the relevant documentation. walk400h is a micro-computer with highly evolved PC connectivity and extensive capacity to memorise and handle holter tests. The features which distinguish walk400h are: - large, colour, LCD graphic display visualises up to six ECG signal charts at the same time; - intuitive, basic user interface uses guided procedures to enable the operator to complete the test easily and rapidly; - wireless PC connection using bluetooth technology or, alternatively, via USB cable; - built-in voice recorder to memorise vocal messages during the test (event-marker function) and/or to insert patient details when preparing the test; - incorporated movement sensor to record the motor activity of the patient; - extensive data memorisation, capacity to handle tests lasting from one to seven days; - single, 5-position joystick to rapidly scroll the device menu; - limited size and weight for increased patient comfort; - functions with a single AA battery. The beat-beat acquisition of each ECG channel is performed at a minimum frequency of 250 samples per second per channel. For special analytic tests a higher sampling frequency may be chosen. All the ECG channels are recorded without interrupting the beat-beat acquisition of the signal and without any sort of signal compression. The recorder contains a flash memory of one GB thanks to which holter charts lasting a total of one week can be memorised. 0476 Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2 Cardioline S.p.A. Via De Zinis, 6 38011 Cavareno (TN) Italy info@cardioline.it Business office: Via F.lli Bronzetti, 8 20129 Milano (MI) Italy tel.+39 02 94750470 fax +39 02 94750471

walk400h Technical specifications Channels... configurable from 3 to 12 acquired channels acquired simultaneously and continuously Duration of recording... from 1 to 7 days (depending on the functioning mode) Sampling frequency... 250, 1000 samples per second (depending on the functioning mode) Resolution... 14; 15 bit (depending on the functioning mode) Sensitivity (LSB)... 2.5microV/bit; 5.0 microv/bit (depending on the functioning mode) Input signal range... AC: ±40mV Input signal range... DC: ± 400mV Frequency response... 0.05Hz 150Hz Common mode rejection... > 90dB Time constant... 3.3 sec Saturation detection... performed for each channel Pacemaker recognition... hardware detection on 3 channels Connection to PC... wireless type Bluetooth Class II in real-time; USB cable to download the test Display... colour display for visualisation of ECG chart, quality of electrode/skin contact and messages for preparation and download of the test Display resolution... 2,2 ; 240x320dots; ¼ VGA Voice recorder... incorporated Event Marker... using keypad plus voice recorder Memory... 1 GB, incorporated in the device. LED... 1 green LED to check battery status; 1 blue LED to check system status Keys... 1 multi-function, 5-position joystick Patient cable... 5; 7; 10-wire cable with snap attachment Defibrillator protection... absent Power supply... 1 AA alkaline battery (ultra or rechargeable NiMh of at least 2500 mah) Dimensions... 96x65x20 mm Weight... 105g (with battery) 80g (without battery) Housing protection category... IP 30 Applied parts... type CF Classification EEC Directive 93/42 IIa Classification (EN60601-1... internally powered device Type CF PC Interface... Standard Bluetooth key or USB 2.0 Environmental operating conditions... temperature between +10 and +45 C relative humidity between 25 and 95 % (without condensation) atmospheric pressure between 700 and 1060 mbar Environmental storage conditions.. temperature between +10 and +45 C relative humidity between 25 and 95 % (without condensation) atmospheric pressure between 500 and 1060 mbar 0476 Product description: sp_walk400h_cardiolinespa_07_eng1.doc 2/2 Cardioline S.p.A. Via De Zinis, 6 38011 Cavareno (TN) Italy info@cardioline.it Business office: Via F.lli Bronzetti, 8 20129 Milano (MI) Italy tel.+39 02 94750470 fax +39 02 94750471

cubeholter cubeholter is the complete solution to manage Holter ECG tests. cubeholter combines all the typical procedures for the Holter test in a single application: from recorder management to downloading the test to a PC and automatically archiving it, from automatic analysis and review to printing out the final document and exporting it in electronic format. cubeholter can operate as a single workstation, or the database can be shared with other networked cube workstations. Description User Interface cubeholter makes the most of the graphic potential of Windows, guiding even inexpert users through the correct execution of all phases of the Holter test. Using menus, dedicated keys and guided procedures, working with cubeholter is extremely practical and fast. cubeholter consists of a several windows which can be used to monitor all program features at the same time: from simply displaying the trace in various formats to validating the automatic analysis and printing out the final document. cubeholter has five main windows, each designed to direct the attention of the operator to a particular aspect of the test: the RR window displays the RR tachogram, the dedicated trends for each type of arrhythmia. And offers an overall view of the test thanks to the colour coding and combined use and display of the ECG trace in compact, zoom or superimposed mode; the families window presents the results of the morphological analysis, grouping all complexes found during the Holter recording into classes. It thus represents the ideal tool for analysis editing, thanks to its speed and efficacy; the events window lists all the episodes detected, indicating the number and always allowing the user to evaluate them in context; the ST window focuses the operator s attention on ST and QT segment analysis. All the leads recorded may be displayed singly or together; the report window allows the user to write conclusions, configure the final document for printing, or select one of the configurations saved in the system and the proceed to print out the document. It is also possible to export the document to be printed out in electronic format, or to attach it automatically to an e-mail. A characteristic common to all the windows is their direct interaction with the ECG trace displayed on the screen: the change, enter or delete beat functions are always available, and may be applied to individual beats or groups of beats, as can the prebook printout, or direct printout functions. Changes may be made to the analysis using the mouse or dedicated keyboard keys. To speed up writing of the final report, each window is also provided with a free text area which can automatically be included in the final conclusions of the printed document. Use profile The operator can choose to use all the displays available in cubeholter or can select, to use only those that best meet his or her requirements and approach.

Automatic Analysis The efficiency and performance of the analysis algorithms, together with the calculation power of the latest generation of PCs, guarantee the accuracy of the analysis and allow the program to perform beat-beat analysis very quickly. Automatic analysis is based on classifying anomalies into event types and morphological families. cubeholter executes the following analyses automatically: - arrhythmia analysis; - family analysis; - independent ST and QT analysis for 3/12 channels; - analysis of variability in the time domain, - pacemaker analysis; - atrial fibrillation analysis. The automatic analysis algorithms are the fruit of over twenty years experience in analysing the Holter test, and of continual research for innovative solutions that perform the analysis algorithms have been validated on the MIT database. All the analysis, printout and display parameters can be customised and saved as system configurations, or a particular configuration can be defined for a single test. Saving tests cubeholter includes a dedicated database in which acquired tests can be saved and organised. cubeholter places the patient at the centre of the system, creating a virtual clinical record in which all the tests performed by cube workstations are automatically saved. From the first time the test is opened, cubeholter presents a complete and detailed report on the events detected. Managing tests cubeholter offers a system of predefined views of the database, accessed by dedicated icons on the toolbar: so the operator can quickly access the list of tests to report on, and read and sign each test. The program also includes a long term archiving function for the database, which allows tests that have already been analysed to be transferred to an external support (CD, DVD, etc.), maintaining the patient data and overall data on the archived test available online in the database. cubeholter also allows advanced searches to be made using the patient data, test or acquisition device as search parameters. Management of test preparation and downloading procedures cubeholter offers innovative management of the procedures to prepare tests and download them to the PC. The operator can use guided procedures to successfully and efficiently prepare both the recorder and the downloading of the test to the PC, managing the patient data correctly, entering the indications and treatment, programming the duration of the test and programming for pacemaker detection if required. Sharing the database with other cube stations cubeholter was designed with the capability to share its database with other cube workstations. This feature can be used to optimise work in a clinic or ward according to the specific clinical requirements of the individual physician. For example, workstations can be dedicated to downloading tests, and others to their analysis, or to the execution of different diagnostic techniques such as stress tests and rest ECGs

. Technical Specifications Analysis modes Interactive, with the possibility of analysing and reviewing the test by using lists of events, morphological families and trends, automatically preorganised by the software. Also available in superimposition mode. The analysis parameters may be configured and saved for each test. Colour coding Normal, ventricular, supraventricular anticipated, paused, pacemaker-stimulated noisy, aberrant, beats, left/right branch block. List of mains arrhythmias detected Morphological classifications Advanced RR analysis Analysis of ST and QT segment Pacemaker analysis. Print document VEB, SVEB, CPT, VT, SVT, SVS, BRA,DEL, AFIB, ESC; IVR, AIVR, PAU, DEL. Normal beats, ventricular beats pacemaker-stimulated, aberrant beats, left/right branch block. Atrial fibrillation, RR variability in the time domain Analysis of the ST segment and QT interval on all leads, with calculation of the amplitude and duration measurements, and evidence of episodes of depression and elevation. Recognition of atrial pacemakers, Ventricular, atrio-ventricular and fusion beats. Print document fully customisable. Possibility of saving a large number of models. Automatic archive function Export of final document Network connection Reception via internet archiving in the database, optional DVD backup in the SW package. Export and transmission by e-mail of final document in PDF or text format Can be networked and the database shared with other cube workstations. Using holterpilot., Holter traces can be received from peripheral workstations over the internet Registered office Via De Zinis, 6 38011 Cavareno (TN), Italy T. +39 0463 850125 F. +39 0463 850088 Sales Office: Via F.lli Bronzetti, 8 20129 Milan, Italy T. +39 02 94750470 F. +39 02 94750471