MICO Intelligent Power

Similar documents
MICO Solutions for Intelligent Power Distribution

mico Solutions for Intelligent Power Distribution ÔÔMonitor ÔÔDetect ÔÔSwitch Off

PHOENIX CONTACT

PHOENIX CONTACT - 09/2009

21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque

PHOENIX CONTACT

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

EPSITRON Electronic Circuit Breakers Compact and Precise ECBs for DC Circuits

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

METRAClip87 and 88 Clamp Multimeters

Series GLET Accessory for dataloggers series GL in modular enclosure

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

11 VA Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque (nominal torque) Motor Spring return

Installation / Monitoring Technique

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Smart Power Relay E I...

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

SHORT FORM. Product Catalog. (800) time-mark.com

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

EPSITRON Electronic Circuit Breakers For Secondary Side DC Protection

Electronic Circuit Breaker ESS20-0..

Capacitive Torch Height Controller. CHC-200E Instruction

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Trip amplifier, 1 channel

EPSITRON Advanced Power Supply System. High-Performance Meets High-Efficiency

5000 Series Receiver Systems

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Protector ESX10-T

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Operator Manual 1.4 FRACSIM MINI

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Device circuit breakers Selective power distribution: branch out, individual adaptation, modular extension

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Section 7 Inteli-Touch Series Casablanca Fan Co. - Factory Service Department - Technical Library

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Isolators & converters

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electronic Circuit Protector ESX10

WELDING POSITIONER PARTS BREAKDOWN DRAWING GP-200

STEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features

Functional data Factory settings Variable Settings

M 140i. Multifunction Calibrator. Operation Manual

QUINT-PS/ 3AC/24DC/10

Onsite Mobile AC High Voltage Test System

Monitoring Relays. 3RS10, 3RS11 Temperature Monitoring Relays. Relays, analog adjustable 7/55

SET Installation and Operating Instructions. Level switch for two sensors

MultiMeter-Pocket CAT III 1000 V

This portable DC ground fault locator provides a quick and cost-effective solution for ground fault locating in DC distribution systems.

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

Operating Instruction

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SCR POWER CONTROLS LIST PRICE SCHEDULE PC-7. Variable Voltage Controls Phase Angle Zero Fired. On/Off Controls

ma. JUMPFLEX 857 Series. Transducers / Relay and Optocoupler Modules

General Specifications

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

ÔÔEfficient. ÔÔReliable. ÔÔRugged. ÔÔSolution-oriented SWITCH MODE POWER SUPPLIES. Power Supplies, Load Circuit Monitoring and Accessories

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

SPECIFICATION EP 1000/1500/2000 Series

TORKEL 900-series Battery Load Unit

Technical Information itemp TMT180

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

TORKEL 900-series Battery Load Unit

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Valve Island with Electronic I/O

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

Relay modules, Relay sockets, Plug relays

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Technical data. Parameterisable damper actuator in the

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

ET 51 - Electrician Theory Examination Marking Schedule

Overview of types. Technical data

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

AF10 PWM Generator. Manual. Valid as of firmware version v1.4.1

METREL Measuring and Regulation Equipment

Figure 1. Two- and Three-phase MagneX Interrupter.

INSTRUCTION MANUAL Redox sensor M 1322 C

Two- and three-phase MagneX interrupter

GE Infrastructure Sensing. Druck DPI 841/842. Frequency calibrator and Frequency loop calibrator User manual - K395

QUINT-PS AC/24DC/40

LP 600 Orion Electronic Dimmer for Magnetic Adapters in Poultry Houses User Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

Installer Guide. Read Me First... PA 8 ELITE PA 8 ULTRA ELITE PA 16 ELITE. Multi-Channel Power Amplifiers. If you need help...

DC Circuits, Ohm's Law and Multimeters Physics 246

Dx: Digital Multi-Channel Telemetry System

Panel Mount Tachometer, PE5

Workshop Part Identification Lecture N I A G A R A C O L L E G E T E C H N O L O G Y D E P T.

APPA 300 Series. The Most User-Friendly High Performance Multimeter

CLASSIC 300D Kubota PARTS LIST FOR RETURN TO MAIN INDEX

Transcription:

MICO Intelligent Power Distribution Monitor Detect React First Class Power Distribution MICO is the intelligent power distribution module from Murrelektronik for 24 V DC. It monitors currents, indicates when approaching the maximum load and make targeted circuit isolations during overload or short circuit conditions. This makes sure systems run at maximum capacity. Example: Why don t circuit breakers trigger reliably in a 24 V DC system? Installation wire 1.5 mm²/3 m Circuit breaker Ri = 0.06 Ω R = 10 m Ω per terminal Distributor cable Incoming cable 0.34 mm²/10 m Outgoing cable 0.75 mm²/10 m Passive distribution box Sensor cable 0.34 mm²/5 m Specific resistance of copper (ρ) = 0.0178 (Ω x mm² / m) Total loop resistance = 1.32 Ω Calculation of maximum current flow I = U 24 V = R 1.32 Ω = 18.1 (Limited by loop resistance) Required tripping current for the type C circuit breaker 14 x I Nenn = 14 x = 8 Tripping current max. Current flow 8 > 18.1 MICO MICO CLASSIC Adjustable current ranges Channels with remote switch on function MICO+ Adjustable current ranges Channels with remote switch on/off function Preventive diagnostics Page 1.5.3 Page 1.5.7 MICO BASIC Preset current ranges Small size MICO FUSE Socket for glass tube fuses Page 1.5.7 Page 1.5.10

Over current protection device adjustable current ranges Early warning (%) MICO+ 4.4 MICO+ 4.6 +24 V DC 0 ON/OFF 14 % +24 V DC 0 ON/OFF 14 % 6. 6. 6. 6. Order Data Art-No. Art-No.,,, 00-41084-0100400,,, 00-41084-0100600 Current adjustment,,,, by countersinked rotary switch, sealed,,,, by countersinked rotary switch, sealed max. 20 ma; high: all channels ON; low: not all channels ON Remote start (OFF) Early warning (%) max. 20 ma; high: one channel over %; low: all channels under % 2 16 mm² per output 2 1.5 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C)

Over current protection device adjustable current ranges MICO+ 4.10 Early warning (%) +24 V DC 0 ON/OFF 14 % Order Data Art-No.,,, 00-41084-0401000 Current adjustment,,,, by countersinked rotary switch, sealed max. 20 ma; high: all channels ON; low: not all channels ON Remote start (OFF) Early warning (%) max. 20 ma; high: one channel over %; low: all channels under % 2 16 mm² per output 2 1.5 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C)

Over current protection device MICO 4.4 MICO 2.4 2 channels +24 V DC 0 ON +24 V DC 0 V ON OUT1 OUT2 Order Data Art-No. Art-No.,,, GL 00-41034-0100400 00-41042-0100400 Current adjustment,,,, by countersinked rotary switch, sealed potential free alarm output 30 V AC/DC, 100 ma 2 16 mm² 1 16 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C) 36

Over current protection device MICO 4.6 MICO 2.6 2 channels +24 V DC 0 ON +24 V DC 0 V ON OUT1 OUT2 Order Data Art-No. Art-No.,,, GL 00-41034-0100600 00-41042-0100600 Current adjustment,,,, by countersinked rotary switch, sealed potential free alarm output 30 V AC/DC, 100 ma 2 16 mm² 1 16 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C) 36

Over current protection device MICO 4.10 MICO 2.10 2 channels +24 V DC 0V ON +24 V DC 0V ON OUT1 OUT2 Order Data Art-No. Art-No.,,, GL 00-41034-0401000 00-41042-0401000 Current adjustment,,,, by countersinked rotary switch, sealed potential free alarm output 30 V AC/DC, 100 ma 2 16 mm² 1 16 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C) 36

Over current protection device MICO 4.4.CTUATOR-SENSOR MICO 4.10 SPEED START optimized start-up behavior +24 V DC 0 V ON +24 V DC 0V ON Order Data Art-No. Art-No.,,, ;,,, 00-41034-0101000,,, 00-41034-0401005 Current adjustment,,, ;,,,, by countersinked rotary switch,,,,, by countersinked rotary switch, sealed sealed max. 30 mf (per channel) potential free alarm output 30 V AC/DC, 100 ma 2 16 mm² Bridging concept two sides, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C)

Over current protection device preset tripping current MICO BASIC 8.2 8 channels MICO BASIC 8.4 8 channels MICO BASIC 8.6 8 channels +24 V DC 0 ON 13 OUT1 OUT2 OUT8 +24 V DC 0 ON 14 OUT1 OUT2 OUT8 +24 V DC 0 ON 14 OUT1 OUT2 OUT8 Order Data Art-No. Art-No. Art-No. 00-41068-0200000 00-41068-0400000 00-41068-0600000 Current adjustment max. 20 ma; high: all channels ON; low: not all channels ON 1 16 mm² Bridging concept one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C)

Over current protection device preset tripping current MICO BASIC 4.2 MICO BASIC 4.4 MICO BASIC 4.6 +24 V DC 0 ON 13 OUT1 OUT2 OUT8 +24 V DC 0 ON 14 OUT1 OUT2 OUT8 +24 V DC 0 ON 14 OUT1 OUT2 OUT8 Order Data Art-No. Art-No. Art-No. 00-41064-0200000 00-41064-0400000 00-41064-0600000 Current adjustment max. 20 ma; high: all channels ON; low: not all channels ON 1 16 mm² Bridging concept one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C)

Over current protection device preset tripping current MICO BASIC 5.2/3.6 8 channels +24 V DC 0 ON 14 OUT1 OUT2 OUT5 OUT6 OUT8 Order Data Current adjustment 5 ; 3 max. 20 ma; high: all channels ON; low: not all channels ON 1 16 mm² Bridging concept one side, with spring clamp terminals or bridge set (max. 40 A) 0...+55 C (storage temperature -40...+ C) Art-No. 00-41068-0200600

Socket for glass tube fuses MICO FUSE 24 LED 8 channels MICO FUSE 250 8 channels +24 V DC GND 0 V 14 OUT1 OUT2 OUT8 250 V AC/DC OUT1 OUT2 OUT8 Order Data Art-No. Art-No. 24 V DC 00-41078-0600001 max. 250 V AC/DC 00-41078-0600002 max. 250 V AC/DC Operating current max. (40 C) Total current max. 40 A max. 20 ma; high: all channels ON; low: not all channels ON 1 16 mm² 1 0.5...4 mm² -25...+55 C

Accessories Art-No. Bridge system Quantity: 1 piece Quantity: 10 pcs. 00-41034-0000002 00-41034-0000001 Shortened buttons 1 set (4 pcs.) 00-41034-0000003 Label plates KES 20 8 (white) KMR 5 10 (white) 10 pieces/2 plates (64 pieces/4 plates) 996067 996078 Glass automotive fuse (T) (T) (T) Fuse cap 00-41078-0000002 00-41078-0000004 00-41078-0000006 00-41078-0000010