PMT 221A. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design. Interchangeable Spring Contact Tip

Similar documents
PMT 211A-RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

PHV RO. High impedance passive probe. Features: CeramCore TM Hybrid Probe. Modular Construction. Coaxial Design

Supplied in carry case with additional accessories The PHV 1000-RO is a 400 MHz, standard sized, 100:1 passive probe designed for instruments

PML 711A-RO High impedance passive probe Features:

PHV 1000-RO. High impedance passive probe. Features: CeramCore TM hybrid probe. Modular construction. Coaxial design

PML 791-RO. High impedance passive probe. Features: 2.5 mm Diameter Tip. Coaxial Design. Interchangeable Spring Contact Tip

As all PMK probes the PML 751-RO features CeramCore TM technology. The entire probe

supplies and frequency converters. BumbleBee is also very effective in fast transient measurements

BumbleBee. High Voltage Differential Probe Ord.-No: Features:

PKT 512A-RO High Impedance Passive Cable Divider

PHV RO High Voltage Passive Probe. Instruction Manual

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

400 MHz Passive High-Voltage Probe R&S RT-ZH

TETRIS 1000 High Impedance Active Probe. Instruction Manual

TETRIS User's Guide. High Impedance Active Probe DO177-1

TK 100 Probe Calibrator. Instruction Manual

User s Manual. Miniature Passive Probe. IM EN 3rd Edition

TA MHz oscilloscope probe TA MHz oscilloscope probe

Operator s Manual. PP022 Passive Probe

Operator s Manual. PP017 and PP018 Passive Probes

Operator s Manual. PP016 Passive Probe

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

TT-SI MHz DIFFERENTIAL PROBE

TT-SI MHz Active Differential Probe

TT-SI MHz Active Differential Probe

Oscilloscope Probes and Accessories

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

SA1500X. Operating Basics. Cautions DEVICE SPECIFICATIONS. High Impedance Active Probe

TT-SI 9001 / TT-SI MHz Active Differential Probes


9 Specifications. Specifications NOMINAL CHARACTERISTICS

PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

INSTRUCTIONS MODELS AVX-TFR-MELF TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

TA MHz ±30 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT I, Pollution Degree 2.

INSTRUCTIONS MODELS AVX-TRR-SQMELF TEST JIG FOR USE WITH AVTECH AVR-EB4-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

SCXI MHz Quad 8x1 50 Ω Multiplexer

Appendix A: Specifications

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

NI SCXI Specifications

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

INSTRUCTIONS MODEL AVC MONOCYCLE GENERATOR MODULE SERIAL NUMBER:

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

BENNING. CM7 Electrical Tester. Service Information

NI PXI-2520 Specifications 80-Channel SPST Relay Module

AC Active Transmitter Combiner 8:1

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

RIGOL. User s Guide. RP5600 Passive Probe. July 2010 RIGOL Technologies, Inc.

NI 2865A 0.3 A Matrix Cards for NI SwitchBlock

INSTRUCTIONS MODEL AVX-S1-P2-EX1 PLUG-IN SOCKET OUTPUT MODULE SERIAL NUMBER:

SPLIT.CONVERTER. User's Manual. Version 2.0

Choosing the right Pico Technology active differential probe

NI PXI-2521 Specifications 40-Channel DPST Relay Module

Power Amplifier. Input Characteristics. SPECIFICATIONS NI PXIe-4610 Power Amplifier. Signal Range

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

N2792A and N2793A Differential Probes User s Guide

MDC4500-4B Amplifier/Combiner Data Sheet & User Manual. February Rev 0.95

NI PXI/PXIe-2532 Specifications

User s Manual Current Probe. IM E 2nd Edition IM E

AIM & THURLBY THANDAR INSTRUMENTS

Technical Documentation

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

NI PXI/PXIe-2541 Specifications 300 MHz Ω Matrix

Digital Clamp Meter Model: &

DM-45 Digital Multimeter

VERI50 EFT for EFT calibration applicable to all TRA2000 generators and CDN2000 coupling filters

CURRENT MEARUREMENT SHUNT CS-10/500 USER MANUAL

Passive High Voltage Probes P5100 P5102 P5120 P6015A

High Voltage Differential Probes HVD3605, HVD3206 HVD310x

Keysight N2771B 30 kv High Voltage Probe

NI PXI/PXIe-2540 Specifications

NI PXI-2555 Specifications

BROADBAND LINEAR AMPLIFIER Model F1020 (models F10A and F20A combined)

Thin Film Rectangular Chip Resistors

For model: HVP-10R / HVP-18HF / HVP-28HF / HVP-39pro

User s Manual Current Probe IM E. 6th Edition

High Voltage Differential Probes HVD3605A, HVD3206A HVD310xA

NI PXI-2557 Specifications

Input Characteristics. Measurement Range. SPECIFICATIONS NI PXIe-4357

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

Active: Active probes achieve low input capacitance and high sensitivity by buffering and amplifying the signal close to the point of measurement.

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Electrical Multimeter

BROADBAND'LINEAR'AMPLIFIER Model&F10AD

AIM & THURLBY THANDAR INSTRUMENTS

15B+/17B+/18B+ Calibration Manual. Digital Multimeter

P331-2 set ESD generator (IEC )

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

INSTRUCTIONS MODELS AVX-CA-SEMA TEST JIG FOR USE WITH AVTECH AVR-EB2A-B REVERSE RECOVERY TEST SYSTEMS SERIAL NUMBER:

ZS Series High Impedance Active Probes 2.5 GHz, 1.5 GHz and 1 GHz Probes

Series OLS10KD 10kW HIGH VOLTAGE POWER SUPPLY

NI PXI/PXIe-2529 Specifications

Keysight Technologies N2792A/N2818A 200 MHz and N2793A/N2819A 800 MHz Differential Probes. Data Sheet

INSTRUCTION MANUAL CLAMP ON PROBE

INSTRUCTIONS MODEL AVX-TFR-STUD TEST JIG FOR USE WITH AVTECH AVR-EBF6-B FORWARD RECOVERY TEST SYSTEMS SERIAL NUMBER:

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

Transcription:

High impedance passive probe Features: CeramCore TM Hybrid Probe Modular Construction Coaxial Design Interchangeable Spring Contact Tip IC Contacting System 0.8 to 1.27 mm pitch Unbreakable Reed Switch HF Adjustment The PMT 221A is a 250 MHz, standard sized, 1:1 and 10:1 switchable passive probe designed for instruments having 1 MΩ input resistance. This probe is recommended for general purpose probing applications and is adjustable for low and high frequencies. The probe is rated with 300 V CAT II maximum input voltage and complies with latest safety standards. Like every PMK passive probe the PMT 221A features CeramCore TM technology. The probe's entire core is made of a high quality ceramic hybrid. Pure coaxial design and laser trimmed resistors ensure highest signal fidelity along the signal path offering high bandwidth and fast risetimes for accurate impulse measurements. All switchable probes offer unbreakable coaxial reed switches for changing between attenuation modes. Our passive probes are equipped with PMKs signature spring loaded, needle sharp tips to support precise and safe measurements minimizing the risk of slipping off the board and produce a short circuit. Various types of tips are available. Besides the spring contact tips there is also a solid tip available at the users choice. Probe tips are interchangeable and can be replaced easily. Basic probe accessories and replacement tips are provided within the scope of delivery or can be purchased separately. The probes mechanical construction is modular and therefore spare probe leads are available. See this datasheet and corresponding documents for further details. 1

This datasheet supersedes all previously published material. Specifications that are not marked as guaranteed are published as general information to the user. The instrument should have warmed up for at least 20 minutes and the environmental conditions must not exceed the specified limits of the probe. Note that specifications are subject to change without notice. Electrical Specifications Attenuation Ratio (switchable) (1) 1:1 10:1 (± 2 % at DC) Voltage Coefficient 0.00025 % / V Probe Bandwidth 30 MHz (2) 250 MHz (-3 db) Probe Risetime 12 ns 1.4 ns (10 % 90 %) Maximum Rated Input Voltage (3) Measurement Category I: 400 V rms, 1250 V transient overvoltage Measurement Category II: 55 V rms CAT II 300 V rms CAT II Pollution Degree (3) 2 Voltage Derating Typical Voltage Derating PMT 221A (switched to 10:1) Measurement category I 400 Amplitude AC rms [V] Sinus 300 200 100 0 100K 1M 10M 100M 1G Make sure to comply with the max. Input Voltages stated here to avoid errors of linearity and damage to the probe. (1) connected to oscilloscope with an input impedance of 1 MΩ ± 1 % (2) at 15 pf input capacitance of the measuring instrument (3) as defined in IEC 61010-031 2

Electrical Characteristics 1:1 10:1 Input Resistance (system) 10 MΩ ± 1 % Input Capacitance (system) 80 pf 13 pf incl. oscilloscope Compensation Range 10 pf 35 pf Input Coupling of 1 MΩ AC / DC 1 MΩ AC / DC the Measuring Instrument Input Impedance 100M Typical Input Impedance PMT 221A (switched to 10:1) (switched to 10:1) Z [Ohm] 10M 1M 100K 10K 1K 100 10 10 100 1K 10K 100K 1M 10M 100M 1G Frequency[Hz] Note that the Input Impedance of the Probe decreases as the Frequency of the Applied Signal increases. Mechanical Characteristics Weight (probe only) Cable Length Probe Tip Diameter 55 g 1.2 m 5 mm 77,8 [ 3,06 ] 3,50 [ 0,14 ] 15 [ 0,58 ] 18 [ 0,71 ] 140 [ 5,51 ] 3

Environmental Specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature range operating 0 C to +50 C non-operating -40 C to +71 C Maximum relative humidity operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +50 C Declaration of Conformity The manufacturer declares the conformity of his products with the actual required safety standards in accordance with the Low Voltage Directive (LVD) 2006/95/EC: CEI/IEC 61010-031:2008 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test. WEEE/ RoHS Directives PMK electronic products are classified within the WEEE/ RoHS* category list as monitoring and control equipment (category 9). Category 9 products are exempt from the restrictions under the scope of the RoHS directive. Your help and efforts are required to protect and keep clean our environment. Therefore return any electronic product at the end of its life either to Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 4

Scope of Delivery PMT 221A Order No. 825-221-A00 2 Footer Positioner Adjustment Tool T BNC Adapter 5.0 Ground Blade 5.0 Ground Lead 22 cm IC-Caps 0.8 to 1.27 mm pitch Instruction Manual Insulating Cap 5.0 Probe Protection Cap 5.0 Solid Tip 0.8 mm Spring Tip 0.8 mm Sprung Hook 5.0 Safety Information To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the safety informations stated in the manual before using this product. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-Mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Revision E March 2014 5