SECTION: 15 ZONING RULE LOT AREA 6134 S.F S.F. BUILDING AREA (FOOTPRINT) LOT COVERAGE 20.2% 24.86' FRONT YARD SIDE YARD 8.

Similar documents
RAPID RIVER RUSTIC, INC.


Fastener Schedule. a, b, c. FASTENER Roof 3-8d (2 1 / ) / ) 3-10d. 3-10d ( ) 3-16d box nails. (3 1 2 toe nails on one side

APPLICATION FOR A BUILDING PERMIT

3.1 General Provisions

VERSA-LAM BCI INSTALLATION GUIDE LIMIT STATES DESIGN CANADA

Exterior Wall Fastener Schedule

2x6. 2x8. 2x10. Size. 2-2x10 8'-5" w/ 2 NJ 7'-3" w/ 2 NJ

Introducing AJSTM INSTALLATION GUIDE USA. 8 th Edition USA

SECTION R507 DECKS DECKING LEDGER BOARD BEAM. FOOTING BEAM SPAN CANTILEVER For SI: 1 inch = 25.4 mm FIGURE R507.2 DECK CONSTRUCTION

Use the Design Properties (100% Load Duration) Table from Page 3 for questions 1-7

T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY

When is a Building Permit Required? Deck Details: What Must be Submitted with a Building Permit Application?

FASTENERS BUILDING DEPARTMENT

DECK PERMIT APPLICATION PACKET

3. Are component and cladding design pressures consistent with ASCE 7 for the wind speed and exposure category (ASCE 7 Fig. 6-3)?

DECKS. Stairway illumination Positive attachment of ledger Lateral load connection required board (R507.2) required (R ) (R311.7.

Typical Deck Details

Vertical Offset Base and Safety Rail System Installation Instructions

Typical Deck Details

RIDGE-JOIST CONNECTION 12/12 maximum slope

Garage Design Guide. October 2018

Deck Evaluation Checklist

Typical Deck Details Based on the City of Nixa Residential Deck Ordinance

Wood structures Copyright G G Schierle, press Esc to end, for next, for previous slide 1

Sections & Details VOCABULARY

installation Guide What you don t Safety I-Joist Storage and Handling United states Installation Instructions for Residential Floor Systems

Deck Design Guide. One and Two Family Residential Dwellings

Featuring TJ Rim Board and TimberStrand LSL

City of Virginia Beach, Virginia Typical Deck Details

ROOF-CEILING CONSTRUCTION

6x6 Shed Plans and Building Guide

City of Long Beach Department of Development Services Building and Safety Bureau. Wood Frame Prescriptive Provisions For Residential Construction

Maryland Building Officials Association Typical Deck Details

ONE AND TWO FAMILY DWELLINGS Uncovered Decks July, 2007

Pulaski County, Virginia Typical Deck Details Based on the 2012 Virginia Residential Code

FREDERICK COUNTY USBC/IRC 2015

Chapter 7 - Porch Framing

FRAMING DETAILS FOR FLOOR AND ROOF

10x10 Shed Plans and Building Guide

CUTTING, NOTCHING, AND BORING OF WOOD FRAMING MEMBERS (Unless an alternate design is provided by a licensed Engineer or Architect)

Ohlson Project Property Owner: Kathy Ohlson Property Address: Deer Lake Rd. Derwood MD 20855

IRC 2015 Code Compliant Wood Framed Residential Details. Incorrect Installations of Connectors with code references and remedies, discussion.

Wall and Ceiling Framing

Unit 9. Wall and Ceiling Framing

Main Floor Revisions: 38' 0" Rm1 H3 50' 0" Bk1 B1 Rm2 B5 (26)-2 H2 B2 H3 (3)-3 B3 (11)-4 Bk1 B1 (5)-5 Rm4 Bk1 Rm3 Bk1 24' 0" 6' 0" 20' 0" START FRAMIN

Residential Decks. Typical Deck Details DECKING REQUIREMENTS

ROOF-CEILING CONSTRUCTION

Chapter 6 - Walls & Stairs

S001 LOWER LEVEL ISO SECOND FLOOR ISO S001 FULL ISO FIRST FLOOR ISO. O="Katahdin Engineering, LLC",

TJI 110, TJI 210, TJI 230,

Sections & Details. WOOD SILL and FLOOR CONSTRUCTION NOTES

Building for High Wind Resistance in Light-Frame Wood Construction

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

TRUS JOIST TJI. Featuring Silent Floor Joists for Residential Applications. Uniform and Predictable. Lightweight for Fast Installation

8x8 Shed Plans and Building Guide

Chapter 3. Wall Layout

ROOF-CEILING CONSTRUCTION

Entry Level Assessment Blueprint Carpentry

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

12x12 Shed Plans and Building Guide

Pre Drywall Inspection Report

TYPICAL PATIO COVERS. OWNER: ADDRESS: PHONE:

E-Blueprints. Children s Backyard Playhouse 8 x sq. feet main 32 sq feet porch 2 x 4 Framed Walls 6' Ceiling Height

APA Performance Rated Rim Boards

A. Rough carpentry includes but is not limited to the following:

Residential I-Joist & LVL INSTALLATION GUIDE

LP SolidStart LSL. LP SolidStart LSL Prescriptive Roof Framing Technical Guide 2500F b-1.75e, 2360F b -1.55E and 1730F b -1.

Material List for Log Complete Packages

TJI 210 TJI TJI 360 TJI 560 JOISTS

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

Dave's Glossary of Construction Terms. by Dave Osborne (

Call (770) STEP 6: Caulk bolt hole within the bracket for protection from the elements.

PANEL NOTATION (3) D4 D3 D2 D3X2 SHEATHING THICKNESS (IN.) D " NAILS/ SPACING " o.c. SILL BOLT SPACING 1 2 " 36" O.C. 1 2 " Ø

Experienced Worker Assessment Blueprint Carpentry

PRESCRIPTIVE RESIDENTIAL DECK CONSTRUCTION GUIDE. Based on the 2015 International Residential Code

With Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans

TRUS JOIST RIM BOARD. Featuring TJ Rim Board and TimberStrand LSL. Multiple thicknesses, grades, and products to cover all your rim board needs

Typical Deck Details

BUILDING THE BASIC SHED. Step A: Build the Foundation & Floor Frame

BUILDING PLANS. BUILDING DEPARTMENT

10. Vents, Baffle Guard and Blocking

BUILDING PLANS. BUILDING INSPECTIONS DEPARTMENT

With Illustrations, Blueprints & Step By Step Details Brought To You By ShedPlansz.Com Click Here To Get More Shed Plans

IRC 2012 Code Compliant Wood Framed Residential details. Miss Installed Connectors with code references and remedies, discussion.

PAINT & MISC. Notes. Table of Contents. Front Handrail Posts Front Handrails Closet Shelving Exterior Deck...

Materials. Description Quantity/Size Material Foundation Drainage material. 1.4 cu. yd. Compactible gravel

Wood Roof Framing Common Design and Construction Defects Concurrent Session #5.3, Friday April 28, 2017, 9:45 AM-10:30 AM

INSTALLATION GUIDE FOR FLOOR AND ROOF FRAMING

Strands & Standards CARPENTRY 2

Best Barns USA. Assembly Book. 12'x 16' the Millcreek. Revised September 19, 2017

Installation Manual For ToddPod Outdoor Shower Enclosures

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Belmont with pocket doors. Building Size 12'x16' or 12'x20' Revised January 10, 2012

Lateral Support. Decks over 24 above grade require lateral support* *Exceptions to be discussed later

DOCUMENT SUBMITTAL REQUIREMENTS FOR AN ALTERATION OR ADDITION TO AN EXISTING SINGLE-FAMILY DWELLING OR MULTI-FAMILY DWELLING

CONSTRUCTION / HOUSING

Chapter 23. Garage Construction

HOW TO BUILD A 12X8 SHED

Attached/Detached Patio Cover

Step 2 - Measure and install joist hangers every 16". See Figure "B" above. Fill every hole in each

Transcription:

PROPOSED 1ST FLOOR PROPOSED 2ND FLOOR Anthony Hatziioannou Architect, P.C. EXISTING 1ST FLOOR ZONING CALCULATION JURISDICTION: TOWN OF OYSTER BAY SECTION: 15 BLOCK: 71 LOT: ZONE: RESIDENCE R1-7 PERMITTED USE: SINGLE-FAMILY DWELLING ZONING RULE EXISTING PROPOSED REQUIRED TOTAL LOT AREA 134 S.F. 7,000 S.F. [MIN.] 134 S.F. BUILDING AREA (FOOTPRINT) 41 S.F. 1533 [MAX.] 1429 S.F. 23.2% 25' 8.00' LOT VERAGE 20.2% FRONT YARD 24.8' 25' SIDE YARD 8.08' 20' TOTAL / 8' MIN SIDE YARD.42' ' 20' TOTAL / 8' MIN REAR YARD 38'-11" 2 STORIES BUILDING HEIGHT 25% 25' 2 STORIES 21.5' TOTAL 25' 38'-11" 2 STORIES/28' 2 STORIES FLOOR AREA SUMMARY AREA EXISTING FIRST FLOOR SEND FLOOR TOTAL F.A.R. PERCENT ADDITIONAL REQUIRED 33 S.F. 187 SF 1420 SF 429 SF 591 SF 1020 S.F. 12 S.F. 778 SF 27% % 2400 + 40 = 2440 [30% OF LA ABOVE,000 SF] 2400 + 40 = 2440 [30% OF LA ABOVE,000 SF] A-001.00 PROPOSED = 2440 SF 39%

X X X GRASS AREA 1 = 4029 SF GRASS AREA 2 = 217 SF EXIST. 1 STORY 10 X 8 DRYWELL GENERAL REQUIREMENTS: Anthony Hatziioannou Architect, P.C. PAVING AREA 1 = 2 SF PROPOSED 1 STORY ADDITION PAVING AREA 2 = 350 SF PROPOSED 2 STORY ADDITION SURVEY / PLOT PLAN & ADDITIONAL REQUIREMENTS A-025.00

EXISTING 1ST FLOOR PLAN SCALE: 1 = EXISTING 2ND FLOOR PLAN SCALE: 1 = A-050.00

1ST FLOOR PLAN SCALE: 1 = 2ND FLOOR PLAN SCALE: 1 = A-101.00

ROOF PLAN SCALE: 1 = A-102.00

EAST ELEVATION SCALE: 1 = NORTH ELEVATION SCALE: 1 = A-201.00

SOUTH ELEVATION SCALE: 1 = A-202.00 WEST ELEVATION SCALE: 1 =

Beam and Strap 2 3/8" end distance LSTA 24 MTS 30 C H 8 H2.5 @ 1" o.c. 5-8d nails top & btm "MIN. BEARING ON STUD FACE CLEAR SPAN CUT LENGTH ROOF RAFTER TO TOP PLATE (ALTERNATE) CS20 strapping @ 1" o.c. (- 8d nails ) " A35F @ 1" o.c. -8d NAILS May not be installed over sheathing FLOOR TO PLATE A35F/LTP4 LTP4 on plywood sheathing @ 1" o.c. -8d NAILS Provide minimum 1" end distance Equal number of specified nails in each end 1d nail fasteners every hole "MIN. BEARING ON STUD FACE CS 1 STRAPPING DETAILS SCALE: NOT TO SCALE A-301.00

DO NOT allow workers to walk on joists until braced. INJURY MAY RESULT. ALLOWABLE HOLES - TJI Joists No field cut holes in hatched zones Table A - End Support Minimum distance from edge of hole to inside face of nearest end support ROUND HOLE SIZE SQUARE OR RECTANGULAR HOLE SIZE DEPTH 9 1 2" 11 7 8" 1 1" 18" 20" Table B - Intermediate or Cantilever Support Minimum distance from edge of hole to inside face of nearest intermediate or cantilever support ROUND HOLE SIZE SQUARE OR RECTANGULAR HOLE SIZE DEPTH 9 1 2" 11 7 8" 1 1" TJI 2" 3" 3'-" 3'-" 3'-" 4'-" 4'-" Knockouts are located in web at approximately " on-center; they do not affect hole placement. For simple span (5' minimum) uniformly loaded joists meeting the requirements of current Trus Joist product guides, one maximum size round hole may be located at the center of the joist span provided no other holes occur in the joist. 3'-" 4'-" 5'-" 5'-" 4'-" Holes may be located vertically anywhere within the web. Leave 1 8" of web (minimum) at top and bottom of hole. Distances are based on the maximum uniform loads shown in current Trus Joist product guides. For other load conditions or hole configurations contact your Trus Joist representative. ALLOWABLE HOLES - Beams and Headers For uniformly loaded beams only. Rectangular holes are not allowed. No holes in cantilevers. " TJI 2" 3" " 1 '-0" 5'-" 3'-" 8" 10" 1 8 5 8" 10 3 7'-" 4'-" 8'-" 4'-" 8'-" 8'-0" 10'-0" 3'-" '-0" 10'-" 4'-" 8'-0" 3'-" '-0" 10'-" 4'-" 7'-" 1 4'-" 7'-" '-" 1 3'-" '-0" 8'-" 13'-" 8" 10" '-" 3'-" 4'-" 18" '-0" 1 3'-" '-0" 8'-" 14'-" 20" 8'-0" 1 '-" 10'-0" 14'-" Rectangular holes based on measurement of longest side. " " No holes in headers or beams in plank orientation. WARNING Joists are unstable until braced laterally 8 5 8" Bracing Includes: Blocking Hangers Strut Lines 10 3 8'-0" 5'-" 14 3 9'-" 7'-" '-0" 10'-0" 14 3 3 9'-0" 1 3 3 1 3 Sheathing Rim Board Rim Joist WARNING NOTES: Lack of concern for proper bracing during construction can result in serious accidents. Under normal conditions if the following guidelines are observed, accidents will be avoided. 1. All blocking, hangers, rim boards and rim joists at the end supports of the TJI joists must be completely installed and properly nailed. 2. Lateral strength, like a braced end wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing lines of 1x4 (minimum) must be nailed to a braced end wall or sheathed area as in note 2 and to each joist. Without this bracing, buckling sideways or rollover is highly probable under light construction loads - like a worker or one layer of unnailed sheathing. 4. Sheathing must be totally attached to each TJI joist before additional loads can be placed on the system. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges.. The flanges must remain straight within a tolerance of 1 2" from true alignment. SCHEDULE OF FASTENERS MECHANICAL FASTENERS BY "SIMPSON STRONG TIE." LOCATION ROOF RAFTER TO ROOF RAFTER STUD TO PLATE TO ROOF RAFTER STUD TO SILL SILL TO JOIST TO PLATE TO STUD SILL PLATE TO FOUNDATION GROUND SNOW LOAD 20 PSF WIND SPEED (mph) SIMPSON STRONG TIE. MANUF. # LSTA 24 1 1/ x 2 MTS 30 C @ 1" o.c. H 8 @ 1" o.c. CS 1 @ 1" o.c. SEISMIC DESIGN CATEGORY 110 C FASTENERS 2" ROOF RAFTER TO ROOF RAFTER 18-10d TO ROOF RAFTER 7-10d x 1 1/2" TO ROOF RAFTER N/R TO STUDS 20-8d Weathering Severe DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. 3" " " 3'-" '-0" 8" '-0" 2" 3" 1 Do not cut holes larger than 1 1 2" in cantilever 8" 1 4'-" 5'-" '-" 10" '-0" 7'-" '-0" 8'-0" 7'-" 9'-" 9'-" 10'-" 4'-" 8'-0" 10'-" '-0" 10'-0" 1 8'-0" 1 1 3'-" 7'-" 9'-" 10'-0" 1 7'-" 1 14'-" 10" 8 5 8" 5'-" '-" '-" 8'-0" '-" 8'-" " 9'-" '-0" 8'-" 1 8'-" 1 1 1 13'-" 8'-0" 11'-0' 1 14'-" 8 5 8" " '-" 1 13'-" 9'-" 14'-" 1'-0" 9'-0" 1 8'-0" 1 1'-0' 10 3 '-" 8'-0" 9'-0" '-" 8'-0" 8'-0" 10'-0" 9'-" 1 14 3 10 3 14 3 1 18'-" 1'-0" 18'-0" 1 1 1'-0" 1 3 18'-0" 19'-" Cut only round holes and only in the center of beam. ROUND HOLE CHART BEAM DEPTH DO NOT cut holes in cantilever reinforcement. 3 1 3 3 DO NOT cut or notch flange. MAXIMUM ROUND HOLE SIZE 4 3 8" 1" 5 1 2" 1 3 7 1 to 20" 2" See illustration for Allowed Hole Zone SUBJECT TO DAMAGE FROM Frost line depth TO STUD 7-10d x 1 1/2" TO STUD 5-8d 5/8" ANCHOR BOLTS @ o.c., @ RNER w/ 5/8" BOLTS w/ 3" x ASHER LBP 1/2 Termite Mod. - Hvy TO PLATE N/R TO PLATE 4-8d NYS RESIDENTIAL DE NOTES Decay Winter Design Temp. Moderate 11 NAILING REQUIREMENTS TJI joists at bearings: Two 8d (2 1 2") box nails (1 each side), 1 1 2" minimum from end. Blocking panels, rim joist or rim board to bearing plate: TJI blocking panels or rim joist: 10d (3") box nails at " o.c. Trus Joist rim board: Toenail with 10d (3") box nails at " o.c. or 1d (3 1 2") box nails at " o.c. Shear transfer: Connections equivalent to decking nail schedule. Rim board, rim joist or closure to TJI joist: 1 3 width or less: Two 10d (3") box nails, one each at top and bottom flange. 2 1 1" thru 2 1 2" widths: Two 1d (3 1 2") box nails, one each at top and bottom flange. 3 1 2" width: Toenail joist to rim joist with one 10d (3") box nail each side of joist top flange. 2x4 minimum squash blocks: Two 10d (3") box nails, one each at top and bottom flange. NAILING SCHEDULE TABLE 3.1 JOINT DESCRIPTION NUMBER OF NAILS NAIL SPACING ROOF FRAMING RAFTER TO TOP PLATE (TOE-NAILED) 3-8d PER RAFTER CEILING JOIST TO TOP PLATE (TOE-NAILED) 3-8d PER JOIST CEILING JOIST TO PARALLEL 3-1d EACH LAP RAFTER (FACE-NAILED) CEILING JOIST LAPS OVER 3-1d EACH LAP PARTITIONS (FACE-NAILED) LLAR TIE TO RAFTER (FACE-NAILED) 3-8d PER TIE BLOCKING TO RAFTER (TOE-NAILED) EACH END RIM BOARD TO RAFTER (END-NAILED) 2-1d EACH END WALL FRAMING TOP PLATE TO TOP PLATE (FACE-NAILED) 2-1d 1 PER FOOT TOP PLATES AT INTERSECTIONS (FACE-NAILED) 4-1d JOISTS - EACH SIDE STUD TO STUD (FACE-NAILED) 2-1d 2 o.c. HEADER TO HEADER (FACE-NAILED) 1d 1" o.c. ALONG EDGES TOP OR BOTTOM PLATE TO STUD (END NAILED) 2-1d PER 2 x 4 STUD 1. 2. 3. 4. 5.. 7. 8. 9. 10. 11.. 3-1d 4-1d PER 2 x STUD PER 2 x 8 STUD BOTTOM PLATE TO FLOOR JOIST, BAND JOIST, 2-1d PER FOOT END JOIST OR BLOCKING (FACE-NAILED) FLOOR FRAMING JOIST TO SILL, TOP PLATE OR GIRDER (TOE-NAILED) 4-8d PER JOIST BRIDGING TO JOIST (TOE-NAILED) EACH END BLOCKING TO JOIST (TOE-NAILED) EACH END BLOCKING TO SILL OR TOP PLATE (TOE-NAILED) 3-1d EACH BLOCK LEDGER STRIP TO BEAM (FACE-NAILED) 3-1d EACH JOIST JOIST ON LEDGER TO BEAM (TOE-NAILED) 3-8d PER JOIST BAND JOIST TO JOIST (TOE-NAILED) 3-1d PER JOIST BAND JOIST TO SILL OR TOP PLATE (TOE-NAILED) 2-1d 1 PER FOOT STRUCTURAL PANELS DIAGONAL BOARD SHEATHING 1" x " OR 1" x 8" 1" x 10" OR WIDER GYPSUM WALLBOARD ROOF SHEATHING 8d 3-8d CEILING SHEATHING 5d OLERS SEE TABLE 3.8 7" EDGE / 10" FILED WALL SHEATHING STRUCTURAL PANELS FIBERBOARD PANELS 8d SEE TABLE 3.9 7/1" d 3" EDGE / " FIELD 25/32" 8d 3" EDGE / " FIELD GYPSUM WALLBOARD 5d OLERS 7" EDGE / 10" FIELD HARDBOARD 8d SEE TABLE 3.9 PARTICLEBOARD PANELS 8d SEE TABLE 3.9 DIAGONAL BOARD SHEATHING 1" x " OR 1" x 8" 1" x 10" OR WIDER FLOOR SHEATHING STRUCTURAL PANELS 1" OR LESS 8d " EDGE / " FILED GREATER THAN 1" DIAGONAL BOARD SHEATHING 1" x " OR 1" x 8" 10d " EDGE / " FILED 1" x 10" OR WIDER 3-8d 1. NAILING REQUIREMENTS ARE BASED ON WALL SHEATHING NAILED " ON-CENTER AT THE PANEL EDGE. IF Ice shield underlayment required Yes Flood hazard - AIR FREEZING INDEX 49 STAIRS NOTES: ALL STAIR OPENINGS AND HEADERS ARE BASED ON BASEMENT CEILING HEIGHT OF 8'-0" ANLESS SHOWN OTHERWISE RISE, RUN AND OPENINGS FOR STAIRS MAY VARY AS PLAN DESIGN VARIES. MAXIMUM RISER OF 8 1/ MINIMUM TREAD OF 9" WITH AN 1 1/ NOSING. BUILDER IS RESPONSIBLE TO INSTALL BASEMENT STAIRS, LANDING AND RAILINGS. RAILINGS MAXIMUM VARIATION IN RISER HEIGHT BETWEEN 2 ADJACENT RISERS IS 3/1" MINIMUM CLEARANCE FROM WALL TO HANDRAIL IS 1 1/2", HANDRAIL MAY PROJECT LANDINGS SHALL BE AS WIDE AS STAIRS BUT NOT LESS THAN 3" SWING OF DOOR OPENING ON A STAIRWAY SHALL NOT OVERLAP TOP STEP. ALL STAIR RAILINGS AND GUARD RAILS SHALL BE INSTALLED BEFORE DWELLING IS OCCUPIED. 3 OR MORE RISERS SHALL BE PROTECTED BY HANDRAIL ON AT LEAST ONE SIDE. OPEN SIDES OF STAIRS OR LANDINGS 18" OR MORE ABOVE ADJACENT FLOOR SHALL HAVE RAILINGS. OPEN RAILINGS SHALL HAVE GUARDS BELOW RAILING THROUGH WHICH A 4' SPHERE CANNOT PASS. STAIRWAY SHALL BE PROVIDED WITH ELUMINATION AND WITH A SWITCH IN BOTH DIRECTIONS. ROOF SHEATHING ATTACHMENT REQUIREMENTS FOR WIND LOADS SHEATHING LOCATION 4' PERIMETER EDGE ZONE INTERIOR ZONE ROOF 2ND FLOOR 1ST FLOOR SHOWER W 2" W TUB 2" W DOUBLE KITCHEN SINK TABLE 3.8 110 MILE WIND SPEED (mph) RAFTER/TRUSS SPACING (INCHES, o.c.) GABLE END WALL RAKE AND RAKE TRUSS SHEATHING SIZE 1 1 RAFTER/TRUSS SPACING (INCHES, o.c.) 1" x " OR 1" x 8" SHEATHING - 19.2 1" x 10" OR LARGER SHEATHING E - NAIL SPACING AT PANEL EDGES (in.) - 19.3 F - NAIL SPACING AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (in.) 2" W.C. LAV. 1 1/2" W D/W U.S. 1 1/2"V TIE INTO APPROVED EXISTING SANITARY SYSTEM STRUCTURAL SHEATHING W.C. TUB 2" W PLUMBING RISER DIAGRAM NOT TO SCALE E MAXIMUM NAIL SPACING FOR 8d MMON NAILS (INCHES, o.c.) LAV. 1 1/2"V 1 1/2" W 1 1/2" W LAV TUB F 4 4 BOARD SHEATHING MINIMUM NUMBER OF 8d MMON NAILS WALL SHEATHING ATTACHMENT REQUIREMENTS FOR WIND LOADS SHEATHING LOCATION 4' EDGE ZONE INTERIOR ZONE SHEATHING SIZE 110 MILE WIND SPEED (mph) STUD SPACING (INCHES, o.c.) STUD SPACING (INCHES, o.c.) STRUCTURAL SHEATHING or PANEL SIDING MAXIMUM NAIL SPACING FOR 8d MMON NAILS (INCHES, o.c.) BOARD SHEATHING or LAP SIDING MINIMUM NUMBER OF 8d MMON NAILS 1" x " OR 1" x 8" SHEATHING - 24 2 1" x 10" OR LARGER SHEATHING E - NAIL SPACING AT PANEL EDGES (in.) 1 1-24 TABLE 3.9 F - NAIL SPACING AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD (in.) E 3 2 3 F W.C. 2" W EX. HOUSE TRAP W VTR Anthony Hatziioannou Architect, P.C. A-401.00