XV CONTROLLERS DETACHED ELECTRONIC UNIT

Similar documents
ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Features. Regulated Converter. RAC02-SE/277/W 2 Watt Single Output. RAC02- SE/277/W Wired. AC/DC Converter

Single Phase Soft Starters

Lexium integrated drives

Features. Regulated Converter RAC05- SK/C14. RAC 5 Watt Single Output RAC05-3.3SK/C14. AC/DC Converter

Note1: Efficiency is tested at nominal input and full load at +25 C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load

Orbital GFI Inverter Series

QUINT-PS/ 1AC/24DC/20

Features. Regulated Converters. RAC01-C RAC02-C 1-2 Watt Single Output RAC0_- C. AC/DC Converter

Features. Regulated Converter. RAC02-SE/277 2 Watt Single Output RAC02- SE/277. AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. Regulated Converter. RAC10-K/ Watt 2 x 1 Single and Dual Output RAC10- K/277. AC/DC Converter

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

QUINT-PS/ 3AC/24DC/10

CI-tronic Analogue Power Controller ACI 30-1 and ACI 50-1

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 3AC/24DC/40

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Features. Regulated Converter RAC Watt Single Output. AC/DC Converter

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

POINTAX 6000L2 Point Recorder

Doc. EA Model Number:

Features. Regulated Converters. RAC05-K 5 Watt 1 x 1 Single Output RAC05- SK. AC/DC Converter

MINI-PS AC/2X15DC/1

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

Features. Regulated Converter. RAC05-K/277 5 Watt Single Output RAC05- SK/277/W. AC/DC Converter

Features. Regulated Converter. RAC04-C/277 4 Watt Single and Dual Output RAC04- C/277 -_. AC/DC Converter

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Piezo Ceramics DC-AC Inverter. Specification

Power supply CP-E 24/0.75

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

18V 35V 65V 40A 60A 1.5W 1.2W ms 40ms. 20ms 20ms. 100mVp-p 200mVp-p 120mVp-p 240mVp-p -25 C - 70 C 48Vout 240mVp-p

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Electronic timer CT-TGD.22

Features. Regulated Converter. RAC05-K 5 Watt 1 x 1. Single Output RAC05- SK. AC/DC Converter

AC/DC Power Supply Series APPLICATION NOTE

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Electronic Circuit Breaker ESS20-0..

QUINT-PS AC/24DC/40

Product Data Sheet 3252J/2H3PU

ABC Series power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Vert-X 28HD - 24V / V. Applications Harvester Public transport Construction machines

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

PSR Interactive Guides. Additional Information. Products Low Voltage Products and Systems Control Products Softstarters Softstarters

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Piezo Ceramics DC-AC Inverter. Specification

IEC/EN/UL60950 & CE certified, EN55032 Class B

Product Data Sheet 8452/2HHP. The engineer's choice

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

Three-phase monitoring relays CM-PFE and CM-PFE.2

Product Data Sheet 3254 J/2H3P

Power supply CP-D 24/1.3


CP-T range Product group picture

Smart Power Relay E I...

ISOMETER Headline IR /IR

Note1: Typical values at nominal input voltage and full load. 17.5VDC. Open, 4.5V Short, 0V. 5mA. Efficiency vs. Input Voltage.

Multi-voltage Multi-function. Wiring diagram (without control signal)

AC/DC Power Supply Series APPLICATION NOTE

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

4.59A 2.36A 6.8A 13A 3.85W 2.85W ms 21ms. 31ms 100ms 48Vout 49ms 100ms. 240mVp-p 480mVp-p C 48Vout 480mVp-p

Electronic timer CT-SDD.22

MINI-PS AC/24DC/1.3

Integrated servo motor

TE90 90W Single Output External Power Test & Measurement/Industrial Series

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

QUINT-PS-24DC/24DC/10

EN 50178, IEC

TE60 60W Single Output External Power Test & Measurement/Industrial Series

RSD-30 series. 30W Reliable Railway DC-DC Converter. (reinforced isolation) File Name:RSD-30-SPEC

CATALOG including...

VARAN Stepper Module VST 012

Power Supplies 3. SDN-C Compact DIN Rail Series

Features. Unregulated Converters. R1SX/R1DX 1 Watt SMD Single & Dual Output R1_X- /_ -R. DC/DC Converter

C B. Models. Models 2MOPP

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

60W Reliable Railway DC-DC Converter. RSD-60 series. File Name:RSD-60-SPEC

Electronic fan speed regulators

Installation / Monitoring Technique

Inverter MICROMASTER 410

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

PHOENIX CONTACT

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

VOF XX - XXX - X

Transcription:

XV CONTROLLERS DETACHED ELECTRONIC UNIT OPERATING INSTRUCTIONS 105N5052 XV Electronic Unit - XV-Frequency 160-264 V / 50/60 Hz www.secop.com NIDEC GLOBAL APPLIANCE

With more than 50 years of experience in compressor technology and highly committed employees, our focus is to develop and apply the advanced compressor technologies to achieve standard setting performance for leading products and businesses around the world. TABLE OF CONTENTS 1. Introduction... 4 2. Compressor speed... 6. Signal input thermostat or frequency... 8.1. Compressor speed frequency... 10.2. Ramp up and ramp down... 11.. Forbidden speeds... 12.4. Emergency control... 1 4. Wiring and connections... 14 4.1. Wiring... 16 4.2. Earth connections... 18 4.. Motor cables... 19 4.5. RAST 2.5 connectors... 20 5. Product safety and information... 22 5.1. Temperature protection... 24 5.2. Compressor safety... 25 5.. Product information... 26 5.4. QR code instruction link... 27 6. Appendix... 28 6.1. Electrical key-parameters... 0 6.2. Dimensions, compressor... 1 6.. Dimensions, detached electronic unit... 2 2

1. INTRODUCTION Nidec GA Compressors revolutionary X-Series compressor range is entirely new and opens up for several new applications and improved refrigeration systems. The completely new platform not only offers the highest system efficiency; with its dimensions it also challenges the standards for compressor size in the future. Typical applications for XV compressor could be: Household refrigerators (LBP) Light commercial refrigerators Bottle coolers Glass door merchandisers Wine coolers Integral freezers Display cabinets Beer coolers The compact size enables 5-20 liters additional storage volume in cabinets or solves small and compact applications. The variable speed lowers the power consumption, limits the number of variants, and increases the capacity range. XV features extreme small extreme light extreme efficient extreme flexible... your benefits additional storage volume for refrigerators less weight, easier handling, lower transport costs increased system efficiency adaptable capacity for various applicaations 4

The XV detached electronic unit is placed next to the XV compressor and connected by a cable. XV detached electronic variant The electronic unit takes input from a customer-controlled frequency signal. Secop 58.10 Appliance Controller The most important functions of XV compressor systems are Motor / compressor variable speed control Speed control to be done by: Frequency input (variable signal) 5

2. COMPRESSOR SPEED The speed and thereby the capacity of the compressor is set using a frequency input. As a rule of thumb, the speed range of 1 : 4 corresponds to 1 :.5 in capacity. XV electronic unit Secop 59.11 Frequency control Speed required 20 V AC Settings Status Communication AC/DC supply Motor control Electronic protection phase BLDC motor A. Frequency input (variable signal) Most applications can use the default settings in the electronic unit and nothing further needs to be changed. The frequency signal from the appliance electronic controller can set the speed directly. If default settings have to be changed, please contact Nidec GA Compressors for special software version. 6

7

. SIGNAL INPUT FREQUENCY The electronic unit has an input signal detection, which will detect the input signal at all times. If a valid speed frequency is detected on the input, the compressor will start within a few seconds. The frequency input signal is a square wave signal, defined from 0-200 Hz and it is a 5 V signal. The frequency signal shape must be minimum 1.5 milliseconds on-time and up to 50% duty cycle. Secop 60.10 8

9

.1 Compressor speed Frequency If an appliance electronic unit in the cabinet can measure the temperature and make a frequency output, it is possible to make a closed loop control of the speed of the compressor. The normal range for speed control is Hz to 1 Hz and there is a linear ratio of 0 related to the compressor speed. Compressor speed [rpm] = Frequency signal [Hz] x 0. The compressor variable speed in this range is from 1000 rpm to 4000 rpm. The conversion is linear and every frequency rpm is allowed. Stop of compressor is at a frequency below 0 Hz. Frequencies higher than 200 Hz will stop the compressor. The below table and figure show the compressor speed range and corresponding frequency range. Frequency [Hz] Compressor speed [rpm] < 0 0. 1000 40 1200 50 1500 66.6 2000 80 2400 100 000 116.6 500 1. 4000 1.-200 4000 200-00 0 Speed [rpm] 4500 4000 500 000 2500 2000 1500 1000 500 0 Compressor speed over frequency signal Normal Range 0 50 100 150 200 250 00 Frequency [Hz] Secop 61.10 If some frequency signals are seen as forbidden see separate section later..2 Ramp up and ramp down If the compressor electronic receives a signal below 0 Hz or above 200 Hz the compressor is first ramped down to 1000 rpm. The speed of the ramp down can be selected. After that the stop process, which is not applying any braking torque is initiated. The possibility to change the ramp up and down speed is an important feature to optimize the noise behavior. Normal ramp up and ramp down is 500 rpm/s In order to secure lubrication and avoid knocking noise, a controlled start and stop is made. When starting, the speed is ramped to 1500 rpm for 1 sec, before regulating towards the set point set by the frequency input. The ramp-up speed can be changed from 1500 rpm and up. The ramp-down speed can be changed down to 1000 rpm. 500 Secop 62.10 Speed [rpm] 000 2500 2000 1500 1000 Start-up 1500 rpm min. 1s 500 rpm/s ramp up/down 500 10 0 0 1 2 4 5 6 7 8 9 10 11 12 1 14 15 t [sec] Target: 000 rpm Target: 1000 rpm

. Forbidden speeds The XV has a completely continuous speed range from 25% to 100% of maximum speed, 1000-4000 rpm, or a factor of 1:4. The compressor alone has no forbidden speeds. But forbidden speed ranges can be used to avoid vibrations due to cabinet and plate resonances or pipe resonances. If it proves necessary to define one or more forbidden speed ranges, the appliance controller must deliver a frequency signal corresponding to only valid speeds. The motor speed ranges can be defined by a forbidden center speed and a delta speed surrounding it. A forbidden speed range is hence defined as: Forbidden speed = Center speed ± Delta speed If a requested motor speed is within a forbidden speed range, the frequency signal is the rpm divided by 0. Example: Given a forbidden speed range at 100 rpm with a bandwidth of +/- 100 rpm, the compressor is not allowed to run at speeds between 000 and 200 rpm. Converted to a frequency signal, this becomes 10. Hz ±. Hz. Forbidden speeds 4500 4000 Compressor speed over frequency signal Secop 6.10 500 Speed [rpm] 000 2500 2000 1500 1000 500 0 0 50 100 150 200 250 00 Frequency [Hz] Compr. speed I Compr. speed III Tip: If a Multimeter is connected to the frequency input wires, the display will show what frequency is critical, related to motor speed at which the cabinet causes resonances. Notice: A frequency generator box can be arranged on special request at Nidec GA Compressors..4 Emergency control In case of signal loss, at a broken wire or if the appliance control electronic becomes a break down, an emergency mode can be activated, means the compressor will run at fixed speed. The dotted line shown at 0 Hz to 10 Hz is optional control by special software. This option can only be selected on request at Nidec GA Compressors. 11

4. WIRING AND CONNECTIONS It is possible to connect the XV electronic unit by use of RAST 2.5 PCB connectors or flat pin connectors. These are standard types of connectors in the industry, which meet the requirements for safe connection combined with requirements for mass production. Connections are different for attached and detached electronic units. Please make sure to follow the appropriate mounting instructions. The XV detached electronic unit has 1 functional wiring: Frequency input Secop 58.10 Appliance Controller 12

1

4.1 Wiring The detached variant of the electronic unit is mounted next to the compressor, and the connection to the compressor is thus done by a cable. A -pole connector and the flat pin earth connection from the compressor must be mounted on the electronic unit, X1. Compressor connect to X1. Secop 64.10 Only two external connections must be connected to X and X5: Mains connect to X with L and N. Use RAST 2.5 power connector. Earth connects to X6. Use flat pin 4.8 mm. Frequency input connects to X5 with R- on ground and R+ on signal. Use RAST 2.5 connector. Cut the noses on each connector as shown in the table as coding. Secop 65.10 Connector description Signal Connection of electronics Termin al PIN Pole s Type Coding 2 X1 1 XV compressor Connection to motor W V X1 2 U 1 RAST 2.5 power a, b, c, d, e, f X6 X5 X2 X 2 1 2 1 2 1 Appliance Frequency signal Earth N L Mains 220V ~ AC Frequency signal from appliance electronic Mains if X connects to appliance unit earth X6 2 Ground Signal X5 2 1 Earth N X2 2 L1 1 4.8 flat pin RAST 2.5 RAST 2.5 power a, b, c, d, a, b, c, d, e, f Connection to mains L1 N X 2 L 1 RAST 2.5 power a, b, c, d, e, f Appliance wall earthing Earth X6 1 1 4.8 flat pin 14

When the XV electronic unit is used as a junction box, the wirings are to be made differently. It is possible to insert a main switch at position Sw, and it is possible to supply the appliance electronic unit from the XV Electronic unit. This is useful if power-up is to be controlled by the appliance unit, or if a longlasting power-off must be made. The connectors then have to be used differently. See signal name and terminals in previous table. Mains connect to X2. All terminals marked with L1 or N is internally connected to X. Use RAST 2.5 power connector. Earth connects internally from X2 to X6. Appliance electronic connects to X. Use RAST 2.5 power connector. In appliance unit, L must be connected to L1 on X. Frequency input connects to X5 with R- on ground and R+ on signal. Use RAST 2.5 connector. Cut the noses on each connector as shown in the table as Coding. Secop 66.10 2 X1 1 XV compressor X5 2 1 Appliance X6 X2 X 2 1 2 1 Sw Frequency signal Earth N L N Mains 220V ~ AC 50 / 60 Hz Appliance electronics If the appliance electronic is able to connect/disconnect mains to/from the XV electronic, which is indicated on the drawing as the appliance relay, the duration between switching off and on must be considered. The XV electronic unit is designed to have permanent mains supply. It must not be switched as often as, for example, cut-in and cut-out of a thermostat, due to risk of excessive inrush current and damaged relay contacts. Switching once a day is considered as safe, but this depends on the quality and switching performance of the relay (e.g. zero-cross switching). The compressor application must factor in power supply from an electrical circuit with the appropriate fuse or circuit breaker. In addition, the use of a GFCI (Ground Fault Circuit Interrupter) or RCD (Residual Current Device) is recommended. 15

4.2 Earth connections Make sure earth protections are properly connected to the compressor, as well as to the electronic unit and mains supply and cabinet. Torque: 160 Ncm 1. Connector cable assemblies: 105N7102-400 mm 105N710-500 mm 105N7104-540 mm Secop 67.10 Torque: 160 Ncm 2. Torque: 120 Ncm Earthing: Check connection! Torque: 160 Ncm.. Mains Earth Click! 4. Motor cables The motor cables used for the detached variant: 105B7102 105B710 105B7104 Code number 400 mm length 500 mm length 540 mm length Due to electronic emissions, it is not allowed to extend the cable to more than 55 cm. 16

4.4 RAST 2.5 connectors This is an overview of different connectors from different suppliers. The list is not complete. Pole Connector RAST 2.5 (Signal) RAST 2.5 Power Lumberg 521 0 K00.. 570 0 K00.. Molex 9050... 9051... Stocko ECO-TRONIC ECO-TRONIC pro MFVV 724-00-... Tyco/AMP DUOPLUG 2.5 DUOPLUG Power 1-966194- 0-194918- / 0-154415- Wire mm²* 0.22-0.5 0.5-0.75 Wire AWG* 24, 2, 22 22, 20, 18 Keying: Secop 68.10 Knife to cut coding It is possible to order 4 different connector kits. This is intended for laboratory use and 0-series production start-up. Connector kit 105N9020 10 set 105N9021 100 set 105N9022 10 set 105N902 100 set Type Attached XV RAST 2.5 (signal) 20 pcs 200 pcs Lumberg 521 0.. RAST 2.5 Power 10 pcs 100 pcs Lumberg 570 0.. Detached XV RAST 2.5 (signal) 10 pcs 100 pcs Lumberg 521 0.. RAST 2.5 power 20 pcs 200 pcs Lumberg 570 0.. 17

5. PRODUCT SAFETY AND INFORMATION 5.1 Temperature protection The protection system ensures that the controller and compressor do not operate at extremely high temperatures, because under these conditions the quality of the soldered joints will be endangered. When the unit reaches 100 C (measured by PCB NTC), the system will shut down and an actual error (thermal shutdown) will be raised. After the temperature has dropped below 90 C, the compressor is restarted automatically. Over-Temperature Protection 100 C 90 C Inverter temp. ON OFF ON Comp. state The under-temperature protection ensures that the compressor, including the magnets in the motor, is not damaged by excessively low temperatures. When the unit reaches -19 C on PCB, the system will shut down and an error (thermal shutdown) will be raised. After the temperature has risen above -17 C, the compressor is restarted automatically. Under-Temperature Protection Inverter temp. -17 C -19 C ON OFF ON Comp. state 18

19

5.2 Compressor safety In order to protect the compressor an advanced compressor motor control is implemented. Several actions are controlled in a safe way and several measurements are taken to achieve safe control of the motor, the windings and the permanent magnets. Safety control functions are: Starting and stopping the compressor, speed control, failure protection, under and over speed, maximum current, motor winding temperature, motor control voltage and BEMF detection and more. The motor settings cannot be changed. Only a special variant of the electronic unit can enable readout of error codes, the actual error and the Actual suberror. Contact Nidec GA Compressors if any needs of alarm handling occur. 5. Product information Labels on electronic units consist of 6 lines with product information and a 2D Data Matrix code. Text information on the label Line 1: Nidec GA Compressors code number, e.g. 105N5052 and product type, e.g. XV 7.2KX Line 2: Unit ID (Unique number): PL YY WW ssssss and date: YY WW PL: Production location, 01 99 YY: Year, 12 = 2012 WW: Week number, 01 52 ssssss: Serial number, 000001 999999 Line : Software Version: V V.VV Line 4: Product Version: VV VV: Version, 00 99 Line 5: Text line: customised text Line 6: Electrical information: Voltage range, Hz The 2D Data Matrix code always consists of 62 characters containing information about type, code number, product version, product revision, unit ID, supplier part number and software. Readout example (62 characters): SLV 20V 105N427 01004074401245A1-124567SW 1.21 2D Matrix code on label Format Field length (char) Example Product type Text 18 SLV 20 V Product number 10 105N427 Product version VV 2 01 Product revision RR 2 0 Unit ID PLYYWWssssss 12 04074401245 Supplier part number Text 10 A1-124567 SW. vers. V.VV 8 SW 1.21 Total 62 20

5.4 QR code instruction link On the compressor a QR code can be found. This is a link to the mounting instructions and installation instructions for the XV compressor. 21

22 6. APPENDIX

6.1 Electrical key parameters Below is a list of parameters and corresponding standards used for test of the 105N5052 XV electronic unit. Name Value / Standards Type code 105N5052 XV detached electronic unit Connection Cable 400/500/540 mm IP class IP 52 Ambient humidity 0 % rh 90 % rh Temperature shock IEC 60068-2-14 Na Vibration random IEC 60068-2-64 Fh Vibration sinus/resonance IEC 60068-2-6 Fc Free fall IEC 60068-2-2 Tropical humidity test 90-95 % No Maximum operating temperature 45 C Minimum operating temperature 0 C Storage temperature - 0 C to 70 C EMC conformity According to 2004/104/EC LVD conformity According to EN 605-2-4 RoHS conformity According to 2011/65/EU EMC conformity EN 55014-2 household appliances Line surge IEC 61000-4-5 (com. mode 2 KV, diff. mode 1 KV) Burst IEC 61000-4-4 (standard 1 kv, tested 4 KV) Power interruption IEC61000-4-11 ESD (Contact discharge 4 KV, Air discharge 8KV) Voltage fluctuations, flicker EN61000-- AC supply (L, N) 160-264 V / 50/60 Hz Voltage drop Speed drop 200 rpm/10 V below 120 V Internal fuse 5 A slow blow External fuse required Max. 16 A Standby power consumption Off mode 100 mw Inrush current, power-up 4A @ 25 C; 40 A @ 0 C Starting current, HST 2 A @ 20 V Electronic efficiency 95-97 % Approval VDE, EN 605-2-4 with annex AA Compressor protection Yes, protective electronic circuits (PEC) Frequency input signal ((R+, R-) Frequency input Wire recommendation Connectors Mains 0.5-0.75 mm ² Harness COM 5 V, max. 12 V or max. 8 ma, 0-200 Hz Galvanic isolation, short and reverse circuit protected 0.5-0.75 mm ², AWG 22, 24 (multi wired) 0.2-0.5 mm² twisted RAST 2.5 and RAST 2.5 power 4.8 mm flat pin 2

24 6.2 Dimensions, compressor

6. Dimensions, detached electronic unit 141.1 16.2 48.5 47 Secop 72.10 55.1 X1 X5 X6 X2 Compressor Frequency or D-Bus Signa Ground Terminal Mains Supply 46. X Appliance Electronics.8 14.9 127 25

www.secop.com Nidec GA Compressors XV compressor makes use of an external rotor motor and new innovative materials. Its simpler construction set-up add to both flexibility and efficiency and a considerable reduction in height, weight and noise. Furthermore, the XV compressor is HST capable. This means it has a high starting torque and can start against a differential pressure. Also its wide voltage range (160-264 V at 50/60 Hz) means that it can operate in refrigerators and freezers in regions with an unstable voltage supply. OUR JOURNEY SO FAR 1956 Production facility and headquarters in Flensburg, Germany founded 1970 Introduction of SC compressors. The birth of a standard setting platform in the light commercial market. 1990 Introduction NL compressors. 1992 Introduction PL compressors. 1999 Start of production with natural refrigerant R290 (Propane). 2005 Introduction GS compressors. 2008 Production facility in Wuqing, China founded. 201 Introduction of the XV compressor. Opening a new chapter in refrigeration history. 1958 Start up production of PW compressors. 1972 Introduction FR compressors. 1977 Introduction TL and BD compressors. 199 Start of production with natural refrigerant R600a (Isobutane) Production facility in Crnomelj, Slovenia founded. 2002 Production facility in Zlate Moravce, Slovakia founded. 2010 Introduction SLV-CNK.2 and SLV-CLK.2 variable speed compressors. Introduction BD1.4F Micro DC compressor. Introduction of DLX and NLU compressors. Nidec Global Appliance Germany GmbH Mads-Clausen-Str. 7 2499 Flensburg Germany Tel: +49 461 4941 0 www.secop.com Nidec GA Compressors accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Nidec GA Compressors reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary to specifications already agreed. All trademarks in this material are the property of the respective companies. Secop and the Secop logotype are trademarks of Nidec Global Appliance Germany GmbH. All rights reserved. Produced by Nidec Global Appliance Germany GmbH August 2014 DES.S.00.G1.02