Introduction to interferometry with bolometers: Bob Watson and Lucio Piccirillo

Similar documents
Pupil Planes versus Image Planes Comparison of beam combining concepts

Introduction to Interferometry. Michelson Interferometer. Fourier Transforms. Optics: holes in a mask. Two ways of understanding interferometry

Introduction to Radio Astronomy!

Coherent Receivers Principles Downconversion

INTERFEROMETRY: II Nissim Kanekar (NCRA TIFR)

Interferometry I Parkes Radio School Jamie Stevens ATCA Senior Systems Scientist

Fundamentals of Radio Interferometry

Multiplying Interferometers

Receiver Performance and Comparison of Incoherent (bolometer) and Coherent (receiver) detection

Radio Interferometry. Xuening Bai. AST 542 Observational Seminar May 4, 2011

Submillimeter (continued)

THEORY OF MEASUREMENTS

Fringe Parameter Estimation and Fringe Tracking. Mark Colavita 7/8/2003

Observational Astronomy

Fundamentals of Radio Astronomy. Lyle Hoffman, Lafayette College ALFALFA Undergraduate Workshop Arecibo Observatory, 2008 Jan. 13

Antennas. Greg Taylor. University of New Mexico Spring Astronomy 423 at UNM Radio Astronomy

Antennas. Greg Taylor. University of New Mexico Spring Astronomy 423 at UNM Radio Astronomy

What does reciprocity mean

Phased Array Feeds A new technology for multi-beam radio astronomy

Guide to observation planning with GREAT

Fundamentals of Radio Interferometry

More Radio Astronomy

Imaging Systems Laboratory II. Laboratory 8: The Michelson Interferometer / Diffraction April 30 & May 02, 2002

Antennas and Receivers in Radio Astronomy

Introduction to Imaging in CASA

Sources classification

Fourier Transforms in Radio Astronomy

Sub-Millimeter RF Receiver. Sub-Millimeter 19Receiver. balanced using Polarization Vectors. Intrel Service Company

Very Long Baseline Interferometry

Fundamentals of Radio Interferometry. Robert Laing (ESO)

A Crash Course in Radio Astronomy and Interferometry: 1. Basic Radio/mm Astronomy

Sideband Smear: Sideband Separation with the ALMA 2SB and DSB Total Power Receivers

Introduction to Radio Astronomy. Richard Porcas Max-Planck-Institut fuer Radioastronomie, Bonn

Lecture 6 Fiber Optical Communication Lecture 6, Slide 1

OPTICS OF SINGLE BEAM, DUAL BEAM & ARRAY RECEIVERS ON LARGE TELESCOPES J A M E S W L A M B, C A L T E C H

Phased Array Feeds & Primary Beams

Introduction to Radio Interferometry Anand Crossley Alison Peck, Jim Braatz, Ashley Bemis (NRAO)

Introduction to Radio Interferometry Sabrina Stierwalt Alison Peck, Jim Braatz, Ashley Bemis

Receiver Design for Passive Millimeter Wave (PMMW) Imaging

EVLA System Commissioning Results

Phased Array Feeds A new technology for wide-field radio astronomy

GPI INSTRUMENT PAGES

instruments Solar Physics course lecture 3 May 4, 2010 Frans Snik BBL 415 (710)

Fundamentals of Radio Interferometry

Principles of Radio Interferometry. Ast735: Submillimeter Astronomy IfA, University of Hawaii

LOFAR: Special Issues

November SKA Low Frequency Aperture Array. Andrew Faulkner

Progress Towards Coherent Multibeam Arrays

Practicalities of Radio Interferometry

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

The Basics of Radio Interferometry. Frédéric Boone LERMA, Observatoire de Paris

Signal Flow & Radiometer Equation. Aletha de Witt AVN-Newton Fund/DARA 2018 Observational & Technical Training HartRAO

Practicalities of Radio Interferometry

Dynamic beam shaping with programmable diffractive optics

9. Microwaves. 9.1 Introduction. Safety consideration

Heterodyne Interferometry with a Supercontinuum Local Oscillator. Pavel Gabor Vatican Observatory, 933 N Cherry Ave., Tucson AZ 85721, USA

Optical Remote Sensing with Coherent Doppler Lidar

Final Feed Selection Study For the Multi Beam Array System

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

The Cosmic Microwave Background Radiation B. Winstein, U of Chicago

Understanding the performance of atmospheric free-space laser communications systems using coherent detection

Radio Interferometry -- II

Sensitive measurement of partial coherence using a pinhole array

G. Serra.

Antenna Engineering Lecture 3: Basic Antenna Parameters

EVLA Memo #119 Wide-Band Sensitivity and Frequency Coverage of the EVLA and VLA L-Band Receivers

Technical Considerations: Nuts and Bolts Project Planning and Technical Justification

Interference [Hecht Ch. 9]

Random Phase Antenna Combining for SETI SETICon03

Why Single Dish? Why Single Dish? Darrel Emerson NRAO Tucson

Using Stock Optics. ECE 5616 Curtis

Section 2 ADVANCED TECHNOLOGY DEVELOPMENTS

A novel tunable diode laser using volume holographic gratings

Department of Mechanical and Aerospace Engineering, Princeton University Department of Astrophysical Sciences, Princeton University ABSTRACT

White-light interferometry, Hilbert transform, and noise

Wide-field, wide-band and multi-scale imaging - II

Polarization Experiments Using Jones Calculus

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes

Why Single Dish? Darrel Emerson NRAO Tucson. NAIC-NRAO School on Single-Dish Radio Astronomy. Green Bank, August 2003.

EXAMINATION FOR THE DEGREE OF B.E. and M.E. Semester

Fundamentals of Interferometry

Considerations for digital readouts for a submillimeter MKID array camera

A 1: 128 multiplexing rate Time Domain SQUID Multiplexer

Basics of INTERFEROMETRY

Wide-Band Imaging. Outline : CASS Radio Astronomy School Sept 2012 Narrabri, NSW, Australia. - What is wideband imaging?

1.6 Beam Wander vs. Image Jitter

NEW LASER ULTRASONIC INTERFEROMETER FOR INDUSTRIAL APPLICATIONS B.Pouet and S.Breugnot Bossa Nova Technologies; Venice, CA, USA

Multi-Path Fading Channel

PREPARED BY: I. Miller DATE: 2004 May 23 CO-OWNERS REVISED DATE OF ISSUE/CHANGED PAGES

Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer

Heterodyne Receivers and Arrays

Channel. Muhammad Ali Jinnah University, Islamabad Campus, Pakistan. Multi-Path Fading. Dr. Noor M Khan EE, MAJU

Fundamentals of Radio Interferometry

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

ALMA Memo 388 Degradation of Sensitivity Resulting from Bandpass Slope

Why is There a Black Dot when Defocus = 1λ?

Antenna-coupled bolometer arrays for measurement of the Cosmic Microwave Background polarization

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

2. Digital Optical Systems based on Coherent and Direct Detection

Transcription:

Introduction to interferometry with bolometers: Bob Watson and Lucio Piccirillo Paris, 19 June 2008

Interferometry (heterodyne) In general we have i=1,...,n single dishes (with a single or dual receiver) Telescopes of diameter D spaced with baselines B ij Form n(n-1)/2 baselines each requiring a correlator to recover the visibility phase shift horns amplifiers complex correlator Complex visibility

Bolometric interferometers are forced to use passive correlators and direct detectors Have to use adding interferometry. phase shift horns + direct detector Complex visibility beam combiner phase shift horns amplifiers complex correlator Complex visibility Heterodyne Amplifier/mixer (low noise elem.) Digital/analogue correlator Diodes Bolometric Nothing Beam combiner (passive) Direct detectors (low noise elem.)

Two ways of doing adding interferometry: 1. Pupil-plane (Michelson) (temporal display of fringes) 2. Image-Plane (Fizeau) (spatial display of fringes)

Pupil plane interferometry (fringes are temporally displayed) Method of combining the two beams using polarizers (or half-silvered mirrors) and then focusing on a single pixel detector. Also called Michelson interferometer. Beam splitter has the property that the phase difference between transmitted and reflected beam is exactly 90 degrees. That s why the +/- Δz(t) variable delay V is the visibility

Image plane combination (fringes are spatially displayed) Method of combining the two beams in which each beam is focused to make an image of the sky. The images are superposed and interference fringes will form across the image. Also called Fizeau interferometer. A phase difference (Δz) is artificially introduced to compensate for optical delays into the system or to modulate the signal into your detector B B 0

Simple adding interferometer α Primary beam Geometric delay φ=2πbsinα/λ Lo-res primary beam Hi-res interference fringe

What signal we expect to see at the detector? recovered with spatial or temporal chopping An FFT will separate directly into visibilities, so one can multiplex different baselines simultaneously.

Use of phase switches in between receiver and transmit horns with orthogonal switch functions allows the extraction of the individual visibility fringes in parallel with only a 2 loss in sensitivity. Fringe patterns caused sky brightness distribution E j is the electric vector collected by horn H j from all elements dω of the sky brightness distribution I(s) with horn beam B(s). Field at point x on the array due to horn j is Ε j (x) = ke j exp(-2πid jx/ Dfr), where k is the dilution factor, d j is the offset of horn j, D is the diameter of the mirror and fr the f-ratio. The exponent term describes the complex phase gradient due to offset E(x) = Σ j ke j exp(-2πid j x/dfr) Power at x = <E(x)E(x)*> = Σ j k 2 <E j E j *> + Σ n<m 2Re[k 2 <E n E m *>exp(-2πi(d n -d m )x/dfr)] Coherence of E vectors due to brightness distribution in horns given by van Cittert-Zernike theorem. <EnEm> = B(s)I(s)exp(2πiu b.s) dω, Where u b is baseline vector formed by horns n and m. So array power distribution is given by N h k 2 B(s)I(s) + Σ n<m 2k 2 Re[exp(-2pi(d n -d m )x/dfr) B(s)I(s)exp(2πiu b.s)] First term is low resolution beam convolved response and the second term is the sum of the interference fringes with amplitude and phase determined by the brightness distribution within the beam.

How to recover the visibilities: 1. Each telescope/optical element has its own phase modulator. 2. Each phase modulator is switched with it s own unique sequence or Walsh function. 3. The modulated baseline signal can be recovered by locking-in with a new Walsh function which is the product of the two Walsh functions used on the phase modulators of the elements which the make up the baseline.

Bandwidth effect. (Green 0%, Blu 10%, Red 20%) Fringes modulated with sinc function or delay beam Spectral bandpass: the visibility decreases with distance from the zero-path difference (either spatial in image-plane or temporal in pupil-plane interferometer) by modulating the interferometer response with the Fourier Transform of the filter bandpass. The number of fringes is N f =2λ/Δ λ. Pupil-plane: reduces the extent of useful delays Image-plane: reduces the extent of the useful image in the focal plane For a compact array we want to use most of primary beam; then bandwidth is limited < array size/element size

Other visibility loss effects: Wavefront tilt: if the two wavefronts to be combined have a relative tilt of angle α, then the interference pattern will be smeared. Improper alignment of optical elements. Intensity mismatch: different optical transmission along different optical paths in the interferometer. If I 1 /I 2 =ρ then This effect is very tolerant. Example T=60%, R=40%, V mismatch =0.98

Other visibility loss effects (continue): Optical surface figure errors. For an rms perturbation δ with respect to a perfect wavefront, then the Strehl ratio will be degraded by a factor: With N surfaces of rms δ 0 then δ=n 1/2 δ 0. Polarization effects: can reduce visibility if not dealt with properly (it might even make the fringes disappear!).

Responsivity of an interferometer is like the number of photons collected from the source. If we want to estimate the number of photons collected by an interferometer we have to specify what is the source. Source filling the beam (CMB) Use brightness units (W/m^2sr) No beam dilution effect because interferometer re-distribute the same photons on a different angular pattern in the sky. Receives twice as much photons because there are 2 horns/mirrors) BUT laws thermodynamics wins out to ensure signal on the detector is also the same uniform brightness Compact object (point source) Use flux units (W/m^2Hz) Beam dilution problem. Less photons collected from a point-like source with respect to aperture filled telescopes Unless use compact array with filling factor near unity.

Instrument response to power spectrum Window function A single beam (total power) experiment: 1. Gaussian beam Gaussian window function (amplitude=1) 2. Beam is azimuthally symmetric - Doesn t care about the orientation of the signal on the sky

An interferometer The beam corresponding to a baseline is not azimuthally symmetric Therefore, the response to C l gets diluted have to average over angles Maximum response Minimum response

Peak of window function proportional to the ratio of blue area over the annulus area u-v space ~1/ So in going to higher l C l response becomes weaker One needs to observe equivalent baselines with different orientations to fill in the UV annulus.

Noise estimates HEMT: Antenna temperature: T ant Bandwidth: Δν NET R-J ~ T ant /η Δν Bolometer: Noise Effective Power: NEP dp/dt ant = 2k B Δνη NET R-J = NEP/2k B Δνη Effective antenna temperature of bolometer:

Noise in a bolometer BLIP: these two guys dominate (hopefully) Johnson + electronics noise where Number of modes in one pol detected in time t and BW Δν

Noise of an Incoherent Interferometer An incoherent interferometer has the disadvantage that the signal from each horn/telescope must be divided before it is detected. Simple sensitivity calculation (give or take a 2): NEP 2 total = NEP 2 BLIP + NEP 2 detector Total loading on each detector: P total = (N/n) P sys NEP 2 BLIP = 2(N/n)P sys hν NEP 2 detector = γ4kt 2 det G for optimized bolometer: G=P total /2T det =(N/n)P sys /2T det => NEP 2 detector = γ2(n/n)p sys (kt det ) so: NEP 2 total = 2(N/n)P sys (hν+γ kt det ) Conclusion: Detector NEP (2(N/n)P sys ) i.e. more detectors, lower NEP

Sensitivity of Interferometer: Conclusions Coherent vs. Incoherent: Factors lost/gained in integration time: Incoherent has to divide signals to correlate - lose f combine ~ N tel Incoherent has to chop phases to do correlation - lose f chop = 2 Incoherent can have both polarisations simultaneously - gain f pol = 2 Incoherent can have wide bandwidth - gain f bw Incoherent can have BLIP limited sensitivity - gain depends on freq. Incoherent can have imaging array interferometry - gain f image ~ N pix Other factors: Incoherent correlator is simple Incoherent interferometer can work at high frequencies

Model of Quasioptical correlator Geometric delays can be easily modelled as a complex phase rotation Different sources just described by different sets of random complex amplitudes. Correlations and random partial correlations correctly taken into account.

Noise Simulations (Coherent) Instead of modelling noise sources as voltages over time E(t) I use sets of complex oscillators A(ν) as they need less numbers to store and are easier to use. 1µs at 30GHz needs 60,000 samples 1µs at 30GHz in 1GHz bandwidth only needs 1000 complex numbers - A i Number of oscillators comes from Nyquist sampling Nosc = B.τ so ΔT = T/ (B.τ) for total power rms variations is a

18 horn hexagonal array Noise Fringes on Array Fringes from LNA noise after phase switching FFT of array data The noise from different LNAs causes random instantaneous fringes at level of T sys / (B.τ). FFT of array gives power just at UV point where you expect signal to appear.

Noise Simulation for 4x4 square array But for a coherent detector array! Antennas and phase switch-forms Visibilities for on-axis source Need detector array twice as big in both axises in order to Nyquist sample fringes and recover phase. So need at least a 8x8 array.

Noise Results on 100 simulations Due to phase switch scheme used common redundant baseline automatically visibilities lie on top of each and S/N boosted by sqrt(nbase).

Simple model of a bolometric polar Healpix map φ φ φ φ

Can back track to see where power on detector came from Can see the gratting array expected from phased array. Centre of array Towards edge

Dual polarization Simulation with HEALPix map input Unpolarized point source PSD1 VL-HR PSD2 VL-VR PSD3 HL-VL PSD4 HL-VR PSD5 HL-HR PSD6 HR-VR 5 o horns 20λ separation

Polarized point source +Q source +U source

Use HEALPix CMB simulation with E & B modes TQU input CMB map nside 256

Visibilities for CMB simulation Strong unpolarized signal with weaker polarized U visibilities at 10%