ROUND LIGHTPLANE 1 3D RLP1/3D MOUNT STANDARD SIZES 1" Aperture Rotatable light channels available in 2ft. and 4ft. sections Customizable 3D design, tailor-made to illuminate any space LAMPING LED - Single & Double-Sided Illumination 80 CRI - 2700K/3000K/3500K/4000K Dimming down to 5% FINISH Natural Anodized Aluminum, Black, Brass, Silver, White, RAL Classic Colors CONSTRUCTION Industrial Strength Extruded 6061 Aluminum ETL Listed 2108
HOW TO SUBMIT YOUR RLP1/3D CONFIGURATION 1. SKETCH YOUR DESIGN IN THE 3D CONFIGURATION GRAPH (PG. 4). Alternatively, you can create your design using the CAD-ready STEP files provided on the RLP1/3D product page. Save your CAD assembly as a.step AP214 file and submit to ALW. 3. COMPLETE THE PRODUCT SUBMITTAL WORKSHEET (PGS. 6-7). PRODUCT SUBMITTAL WORKSHEET SAMPLE PRODUCT CODE RLP1/3D MUD/TRIM 0/40/8 STD/80/3000 0/10V/S EXT AL BK UNV EMC OS 1 2 3 4 5 6 7 8 9 10A 10B 1. BASE MODEL (CHOOSE ONE) RLP1/3D RLP1/3D/F 1" surface-mount, rotatable light channel with 2ft. and/or 4ft. bar(s) directly connected to mounting canopy(s). 1" surface flush-mount, rotatable light channel with no mounting stem. 2. CEILING TYPE (CHOOSE ONE) RLP1/3D RLP1/3D/F MUD/TRIM GRID Universal Mud-In and Trim components for drywall, wood, and other surfaces. Grid Ceilings 3. COUNT (USE CHART ON PAGE 5 TO CALCULATE LINEAR OF S IN FEET) LINEAR (FEET): S Blank Single Double Unilluminated (B) Illuminated (S) Illuminated (D) COMPLETE CODE Separate each with a slash and enter in box to left. ex: 0/8/40 / / 4. LED CCT (CHOOSE ONE) STD/80/2700K 80 CRI, 2700K STD/80/3000K 80 CRI, 3000K STD/80/3500K 80 CRI, 3500K STD/80/4000K 80 CRI, 4000K 1 LUMENS (LM) WATTS (W) EFFICACY (LM/W) 476 4.64 ~100 1 Performance values based off 1ft. Single-Sided (S) Illuminated section. 5. REMOTE DRIVER (CHOOSE ONE) 0/10V/S DALI DMX ECOSYS5 0-10V dimming down to 5% (Standard Dimming) DALI flicker-free dimming down to 0% DMX flicker-free dimming down to 0% Lutron 5-Series 5% EcoSystem, constant current * All drivers are remote. Fixture is ETL listed and conforms to UL Standard 2108. Driver specifications provided upon request to assist with control system integration. 2. CALCULATE IN FEET WITH THE CALCULATOR (PG. 5). 4. SUBMIT FORMS BELOW TO ALW FOR REVIEW. 1. 3D CONFIGURATION GRAPH (PG. 4) or STEP AP214 FILE 2. PRODUCT CODE WORKSHEET (PGS. 6-7) CALCULATOR Use the tool below to determine component quantities 1. Add up the total RLP1/3D lengths: Blank Unilluminated (B), Single-Side Illuminated (S), & Double-Side Illuminated (D). 2. Copy the totals into Step 2 of the WORKSHEET (pg. 2). BLANK (B) UNILLUMINATED DOUBLE-SIDE (D) ILLUMINATED SINGLE-SIDE (D) ILLUMINATED (in.) (in.) (in.) FLUSH x = 24in. x = 48in. x = (B): Add up of all sections. Ex: 36 in. 24in. x = 48in. x = (B): Add up of all sections. Ex: 36 in. 24in. x = 48in. x = (B): Add up of all sections. Ex: 36 in. 2 of 10
3D CONFIGURATION GRAPH EXAMPLE 3D CONFIGURATION GRAPH VIEW BOTTOM VIEW TOP VIEW SYMBOL KEY Solid lines & characters: Solid lines indicate RLP1/3D bars. Characters indicate illumination type. Lightbar Illumination: B = Blank unilluminated S = Single-sided illuminated, D = Double-sided illumiated Place B, S, or D to right side of vertical bars. Place B, S, or D below horizontal bars. Solid-filled circle = Hub Unfilled oval = Mounting Canopy Unfilled oval with solid-filled circle = Indicates when Mounting Canopy and Hub fall on the same visual plane Crossed solid lines = Overlapping bars at different visual planes. These bars are not connected together with a Hub 3 of 10
3D CONFIGURATION GRAPH SYMBOL KEY Solid lines & characters: Solid lines indicate RLP1/3D bars. Characters indicate illumination type. Lightbar Illumination: B = Blank unilluminated S = Single-sided illuminated, D = Double-sided illuminated Place B, S, or D to right side of vertical bars. Place B, S, or D below horizontal bars. Solid-filled circle = Hub Unfilled oval = Mounting Canopy Unfilled oval with solid-filled circle = Indicates when Mounting Canopy and Hub fall on the same visual plane Crossed solid lines = Overlapping bars at different visual planes. These bars are not connected together with a Hub 4 of 10
CALCULATOR Use the tool below to determine component quantities 1. Add up the total RLP1/3D lengths (feet): Blank Unilluminated (B), Single-Side Illuminated (S), & Double-Side Illuminated (D). 2. Copy the totals into Step 3 of the WORKSHEET (pg. 2). BLANK (B) UNILLUMINATED SINGLE-SIDE (S) ILLUMINATED DOUBLE-SIDE (D) ILLUMINATED FLUSH x = 2 ft. x = 2 ft. x = 2 ft. x = (S): (D): (B): Add up (feet) of all sections. See example below. CALCULATOR EXAMPLE The tool below has been filled to match the example configuration on page 3. BLANK (B) UNILLUMINATED SINGLE-SIDE (S) ILLUMINATED DOUBLE-SIDE (D) ILLUMINATED FLUSH x = 2 ft. x 20 = 40 ft. 2 ft. x 4 = 8 ft. 2 ft. x = (S): 40 ft. (D): 8 ft. (B): 0 ft. 5 of 10
PRODUCT SUBMITTAL WORKSHEET SAMPLE PRODUCT CODE RLP1/3D MUD/TRIM 0/40/8 STD/80/3000 0/10V/S EXT AL BK UNV EMC/2ft OS/1 1 2 3 4 5 6 7 8 9 10A 10B 1. BASE MODEL (CHOOSE ONE) RLP1/3D RLP1/3D/F 1" surface-mount, rotatable light channel with 2ft. and/or 4ft. bar(s) directly connected to mounting canopy(s). 1" surface flush-mount, rotatable light channel with no mounting stem. 2. CEILING TYPE (CHOOSE ONE) RLP1/3D RLP1/3D/F MUD/TRIM GRID Universal Mud-In and Trim components for drywall, wood, and other surfaces. Grid Ceilings 3. COUNT (USE CHART ON PAGE 5 TO CALCULATE LINEAR OF S IN FEET) Blank Unilluminated (B) LINEAR (FEET): S Single Illuminated (S) Double Illuminated (D) COMPLETE CODE Separate each with a slash and enter in box to left. ex: 0/8/40 / / 4. LED CCT (CHOOSE ONE) STD/80/2700K STD/80/3000K STD/80/3500K STD/80/4000K 80 CRI, 2700K (very warm) 80 CRI, 3000K (warm) 80 CRI, 3500K (slightly warm) 80 CRI, 4000K (neutral) LUMENS (LM) 1 WATTS (W) EFFICACY (LM/W) 476 4.64 ~100 1 Performance values based off 1ft. Single-Sided (S) Illuminated section. 5. REMOTE DRIVER (CHOOSE ONE) 0/10V/S DALI DMX ECOSYS5 0-10V dimming down to 5% (Standard Dimming) DALI flicker-free dimming down to 0% DMX flicker-free dimming down to 0% Lutron 5-Series 5% EcoSystem, constant current * All drivers are remote. Fixture is ETL listed and conforms to UL Standard 2108. Driver specifications provided upon request to assist with control system integration. 6 of 10
6. LENS EXT Extra diffuse 7. FINISH S (CHOOSE ONE) AL BK BRS SV WH WH/AM RAL Natural Anodized Aluminum (Standard Finish) Black Powder Coat Brass Metallic Powder Coat Silver Powder Coat White Powder Coat White Antimicrobial Powder Coat (for healthcare environments) Specify RAL Classic Color code (ex: RAL3003) ralcolorchart.com/ral-classic 8. FINISH HUBS & CANOPIES (CHOOSE ONE) AL BK BRS SV WH WH/AM RAL Natural Anodized Aluminum (Standard Finish) Black Powder Coat Brass Metallic Powder Coat Silver Powder Coat White Powder Coat White Antimicrobial Powder Coat (for healthcare environments) Specify RAL Classic Color code (ex: RAL3003) ralcolorchart.com/ral-classic 9. VOLTAGE (CHOOSE ONE) UNV 347 Universal Voltage (120VAC-277VAC) 347 Volt (Driver options may be limited) 10. ADDITIONAL OPTIONS (OPTIONAL CHOOSE ONE UNDER A & B, IF DESIRED) A. EMERGENCY OPTIONS EMC 2 Emergency Circuit (light output is equivalent to the standard lumen output of an illuminated bar for 90 minutes) 2 Consult ALW for available options. B. SENSOR OPTIONS (COMPATIBLE ONLY WITH 0-10V DRIVER INDICATE QUANTITY) ENLGHT/ 3 OS/ PH/ Enlighted remote smart sensor (occupancy, daylight, networking, and more) 0-10V remote occupancy sensor 0-10V remote photocell/daylight sensor 3 Enlighted Gateway and Energy Manager (by others) plus programming required. Learn more at enlightedinc.com. 7 of 10
MECHANICAL DIAGRAMS S Single-Sided Illuminated (S) Double-Sided Illuminated (D) Blank Unilluminated (B) 1 3 / 16" 1 3 / 16" 1 3 / 16" 2' nominal (23.7" actual) 4' nominal (47.3" actual) NOTE:.125 inch tolerance applies to actual measurements MECHANICAL DIAGRAMS MOUNTING COMPONENTS TYPE DIMENSIONS CONNECTIONS 3.62in. J-Box Canopy Mud Plate For use with octagonal J-Boxes (not included). Fits 3/8in. wall thickness. Use 1/8in. Mud Spacers for thicker walls. 3/8in. Mud Ring 1.85in. 0.125in. (1/8in.) 1/8in. Mud Spacers 2x included with each J-Box Canopy Mud Plate to fit wall thicknesses of 3/8in., 1/2in., and 5/8in. Ø 1.75in. Ø 2.20in. 2x 1/8in. Mud Spacers 3/8in. Mud Ring 0.30in. Mounting Canopy Ø 2.48in. Ø 3.00in. 8 of 10
MECHANICAL DIAGRAMS HUBS TYPE DIMENSIONS CONNECTIONS L-Hub 2.14in. L-Hub-1 2.64in. T-Hub 2.14in. 2.64in. T-Hub-1 2.64in. X-Hub 2.14in. 2.64in. X-Hub-1 9 of 10
ADDITIONAL OPTIONS & SPECIFICATIONS ELECTRICAL Remote LED Drivers are Class 2. For standard lampings: L 80 > 54,000 hours. Luminous flux +/- 5%. REMOTE DRIVER DISTANCE Constant Current Driver Type Maximum Recommended Wire Length * LENS Extruded, twin-layered, high-impact acrylic. EXT is white, extra diffuse, with minimal to no-source visibility. Dimmable 0-10V DALI/DMX 120 FT 72 FT HOUSING 100% recyclable, extruded architectural grade 6061 aluminum with a 0.08" minimum wall thickness. SAFETY & REGULATORY ETL Listed (U.S. & Canada). Conforms to UL std. 2108, Low Voltage Luminaires / Low Voltage Lighting Systems. Certified to CSA std. C22.2#9.0:1996 Ed. 1+S1. Lutron Hi-lume A Series L3D/LTE 22 FT * This represents the maximum recommended wire length between the fixture and remote driver. Consult ALW for longer distances. See alwusa.com/voltage-drop-calculator for more information. OPERATING TEMPERATURE Luminaire should be installed and operated ONLY in dry or damp environments where the ambient temperature ranges from -4 F to 122 F (-20 C to 50 C). Luminaire operation in environments outside the listed temperature range voids the warranty AND may damage the product or adversely impact lamp life, lumen output and color consistency. WARRANTY Limited 5-year warranty. Details: alwusa.com/warranty FINISH Aluminum White* Black Silver Brass RAL Classic *For healthcare environments, a white antimicrobial finish (WH/AM) is also available. 10 of 10