Technical guide. EC300 motor V8

Similar documents
Specification For Approval

Specification For Approval

Specification For Approval

EC centrifugal fan - RadiCal

B1793 AC Blower Innovation in Motion

Specification For Approval

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

Product Data Sheet 8452/2HHP. The engineer's choice

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Product Data Sheet 8452/2 GHHP

EC centrifugal fan - RadiCal

Product Data Sheet RER190-39/14/2TDMO

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

Product Data Sheet RER220-43/18/2TDMO

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Product Data Sheet 622/2HHP-021

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet DV4112/2NP-201

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

EC centrifugal fan - RadiCal

Product Data Sheet 8214 J/2H4P

Technical Document. for the. CB 016N6 Driver Card

Product Data Sheet 6424/2HP-210

LED Driver Constant voltage

Cooling Fans G-17. Cooling Fans G-17. AC Input/Low-Power Consumption EMU Series. AC Input/Compact Size MU Series

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Series AMEPR60-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

EC centrifugal fan. backward curved, single inlet

Product Data Sheet 3252J/2H3PU

EC centrifugal fan - RadiCal

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Refrigerated Products Brochure. USA Edition

LED Driver Constant voltage

Product Data Sheet 3254 J/2H3P

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 10

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

LED Driver Constant voltage

EC 45 flat with integrated electronics Document ID: en Operating Manual

EC centrifugal fan - RadiCal

Rexroth Frequency Converter

Product Data Sheet 8214 J/2H4P. The engineer's choice

2-02 Start voltage The voltage that enable to start the fan by sudden switch on.

Product Data Sheet RG160-28/18N/2TDPU-331

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

IST-KIT-UR-G Page 1 of 9 KIT-UR-G REVISIONS

C B. Models. Models 2MOPP

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Max. Output Power. Efficiency (1) 110Vac 220Vac

75W Constant Current (700mA) LED Driver

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2

PKG-341-MLA-CBL System Diagram and Specifications

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

EC centrifugal fan - RadiCal

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Rexroth Frequency Converter Fe

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

Electronic Circuit Breaker ESS1 for System SVS1

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

D.C. BRUSHLESS MOTORS DRIVE. BLD07-IT Service Manual

The Drive & Control Company. Frequency Converter. VFC 3610 / VFC 5610 Series. Quick Start Guide R Edition 15

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

LED Driver Constant voltage

LED Driver Constant voltage

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

LED Driver Constant voltage. Udriver LCU 60W 12/24V IP67 EXC EXCITE outdoor IP67 series

Product Data Sheet 6314/2TDHP. The engineer's choice

Industrial Serie +600S

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Ezi-STEP MINI Characteristics

Servo Amplifier - Troubleshooting Guide

PWM-120 series. 120W PWM Output LED Driver IP67. File Name:PWM-120-SPEC

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Lexium integrated drives

50W Constant Current (700mA) Dimming LED Driver

56 mm sq. (2.20 inch sq.)

Brushless DC Motor Controller Specification Assemblies 025F0248

Express Delivery. Axial. Connection

Y-0035 POWER ELECTRONICS TRAINING SET

Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Tangential blowers with multiple housings. Optimized air flow steady distribution.

Installation Instructions for the SNDJ-CNT-G01/SNDJ-CNT-G02 Frequency Measurement and Switching Instruments ISSUE WARNING

ABC400 Series is a compact and efficient series of AC-DC open frame power supplies suited for telecom, datacom and many other applications.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Efficiency higher than 85% Power Factor >92% Case TC* Protection Storage Humidity

Metal Case Power Supplies

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Transcription:

l 15/11/2016 1 st release Page 1 sur 7

Electrical installation 230V version : Motor Class I Power supply Voltage (recommended) 200 220..230 277 Vac Voltage (maximum) 174 293 Vac Frequency 48 50 65 Hz Power usage 1 1..300 300 W Gauge CE type UL type 0.5mm² / Ø0.8mm 0.596mm² / Ø1.02mm / 20AWG Dedicated connector on request Page 2 sur 7

The EC300 motor is a class I product which means connection to protective earth is mandatory to comply with safety regulation. In general, installation should take care to not have power cables and interface cables laying next to each other, perpendicular crossing should be preferred. While the motor is powered ON, do not connect Vctrl (yellow wire : 0-10V / PWM) to an external controller before GND (black wire) is connected. The V8 motor-fan contains electronic device which can be sensitive to electrostatic discharge. Take appropriate care especially when handling the low voltage cable. Page 3 sur 7

Analog input and outputs Inputs : Input 0-10V/PWM Input resistance 100K Ohms 0-10V option Voltage range 0 10 Vdc Full stop voltage 0.7 1 Vdc Minimum speed voltage 1 1.3 Vdc Maximum speed voltage 9.9 10 10.1 Vdc Resolution 8 Bits PWM option Voltage range 0 10 Vdc PWM must be at 0V and 10V (low and high states) Frequency range 1000 10000 Hz PWM range 0 100 % Resolution 8 bits Power consumption Motor not running (Vctrl=0V) 0.95 1.1 W Under 230V Page 4 sur 7

Outputs : +10V isolated Output current 5 ma Short circuit-protected. Opto Type NPN type OC OC=Open Collector External voltage range 1 48 Vdc External current range 5 ma Frequency range 1 60 Hz 60Hz = 3600 RPM Vcesat 0.25 0.4 Vdc Opto type Wiring convention Other cable color on specific request Gauge CE type UL type 0.22mm² / Ø0.61mm 0.343mm² / Ø0.76mm / 22AWG Dedicated connector on request Configured to Tachymeter Duty Cycle 50% 60Hz = 3600 RPM Configured to Alarm Normally Open Or Closed Page 5 sur 7

Additional protection If the motor is connected to an electric installation where an earth leakage circuit breaker is used as additional protection, this circuit breaker must be of the type A or B according to EN50178. Leakage current measured according to EN60335 is less than 3.5mA. Product safety behavior Blocked rotor: The electronic driver detecting a blocked rotor will power off the motor. Every 5s, it will try to restart, up to 25 times. If none of the attempts succeed, the motor will go into a safety mode. It will be necessary to power OFF the motor for about 1 minute to reinitialize and to check if the rotor is rotating freely. Motor overload: In case of overload condition detected by the electronic driver (too high current or too high speed), it will stop powering the motor. It will be necessary to power OFF the motor for about 1 minute to reinitialize and to check if the rotor is rotating freely. Page 6 sur 7

Too low load condition: The motor-fan is configured according to all the range of load the product is expected to work with. In case the load should be abnormally low considering the instant speed, the electronic driver will go into a safety mode. It will be necessary to power OFF the motor for about 1 minute to reinitialize and to check if the rotor is rotating freely. Thermal protection: The electronic driver temperature is constantly monitored to protect the motor from over temperature condition. In case of temperature exceeding 75, the speed is decreased. In case of temperature exceeding 80, the motor is stopped and will run again only when the temperature comes back below 60 C. Low voltage control interface: Always connect the GND signal (black wire) before the 0-10V / PWM signal (yellow wire) or disconnect this Control signal before disconnecting the GND. The product is dedicated to be connected to earth. Besides security reason, connecting device to the low voltage interface without the PE may cause damages to the electronic. Page 7 sur 7