No. CP SS 47E DigitroniK TM Digital Indicating Controller SDC The DigitroniK SDC is a compact digital controller with multi-range and PID autotuning systems for various inputs, with time proportional (on/off) PID and continuous PID control action. The SDC sends relay contact, voltage, current, and the signals from other variables as control output signals. The controller also enhances process visibility with such functions as remote switch input, control parameters, and local set points, which can be easily set using the smart loader. Features Accuracy of ±.%FS. Type of inputs and ranges can be selected by key operation. Two points can be set concurrently. Autotuning system with two groups of PID control constants. Normal and abnormal operations are indicated by an OK lamp for easy decision making. SP ramp setting function allows the ratio of each set point value to be changed. Four modes of action can be selected using remote switch inputs. Compact and lightweight (Dimensions; 48 x x mm Weight; 4g) Optional functions ensure a wide range of applications: Event outputs (UP to points) Heater burnout alarm Auxiliary outputs RS-C/48 Communications CE Marking compliant Applicable standards: EN -, EN Basic Function Block Diagram Process variable (PV) Thermocouple RTD ma mv Linearization Bias Control outputs (OUT) Relay Current Voltage Event outputs (EV: Up to points) Output limit er Local set point (LSP) (Up to points are settable) Data transmission/ receive SP ramp Set point value limit Direct change Current transformer input (CT: point) Remote switch input (RSW: point) LSP No. PID group No. READY / RUN Timer start Non-operation Control operation circuit PID autotuning Direct/reverse action changeover Process variable Set point Deviation Absolute deviation Alarm Timer output Heater burnout alarm Auxiliary outputs (AUX: point) Process variable Set opint value Control signal output Communications output (COMM) EV EV Heater current input RS-48 RS-C Power supply 8 to 4Vac, or. to.4vdc : Optional functions
Specifications PV input Type of input Multi range thermocouple, resistance temperature detector. DC voltage, and DC current. Sampling cycle Input bias. sec Variable within to U. U: C, kgf/cm G{kPa}, %, and others industrial units including decimal point positioning. Note : When the resistor or A line is broken: RTD input : µa Upscale Alarm indication DC voltage input :.µa When B line is broken: Down scale Alarm indication Current input : Ω max. When C line is broken: Undefined indication Alarm indication When A and B lines are broken: Upscale Alarm indication When B and C lines are broken: Upscale Alarm indication RTD input : (See Note ) When A and C lines are broken: Upscale Alarm indication DC voltage input : Downscale Alarm indication When A, B, and C lines are broken: DC current input : Downscale Alarm indication Upscale Alarm indication Input impedance Thermocouple input :.µa Allowable wiring Thermocouple input :.4µV/Ω max. resistance RTD input : ±.%FS/Ω max. Burnout Thermocouple input : UpscaleAlarm indication Data display and Indication method 4 digit, 7 segment LED indication setting OK lamp The control deviation value status is indicated by the green belt. Number of setting points Data storage to points. Optional selection and changeover use are enabled. Non-volatile EPROM Range Thermocouple or RTD input (see Table ) Accuracy Setting range DC voltage or current (programmable range) input: to to decimal places. ±.%FS± digit for display, except for thermocouple B ranged between and C. Thermocouple or RTD input:,. C or,. F (depends on input type) DC voltage or current (programmable range) input:,.,.,. (depends on input type). Setting system Local standard: Direct change is enabled. (see Note ) Note : LSP direct change: This function can change the LSP (local set point) without defining operation by the ENT key. Control output Model number SDC D SDC D SDC G Output type Relay contact Voltage Current Control action Time proportional PID Time proportional PID Continuous PID Number of PID sets sets sets sets PID autotuning Automatic setting of PID value by limit cycle method. Output rating Contact type: SPDT Open voltage:.vdc±% Output current: 4 to ma dc Resistive load: Vac, A Internal resistance:.kω±% resistance: Ω max. Output accuracy:.% on standard conditions Output resolution: Within.% Output update:.sec Proportional band (P):. to.. to.. to. %FS (on/off operation at P=.) (on/off operation at P=.) (on/off operation disabled) Cycle time: sec to to Integral time (I): sec to (PD action at I=) to (PD action at I=) to (PD action at I=) Derivative time (D): sec to (PI action at D=) to (PI action at D=) to (PI action at D=) Manual reset: % to to to Differential gap: U to (when on/off operation) to (when on/off operation) Output Low-limit value to high limit to high limit to high limit limiter % High-limit value low limit to low limit to low limit to SP ramp Function Sets the change rate of set value Range to U/min. Setting Setting of the rising rate of initial PV Setting of the falling rate of initial PV with respect to SP. with respect to SP. Valid when SPU Valid when SPU (SPU: Set Point Up) (SPU: Set Point Down) SP Initial PV PV Up ramp (SPU) Time Initial PV SP PV Down ramp (SPD) Time Remote switch Number of input points point input (RSW) Function Allocates an optional function selectively from among: LSP No.: PID group No. (interlock), READY/RUN changeover, timer start, and timer non-operation Input rating Dry contact or open collector transistor, Off-terminal voltage: ±V, Turn-on current: ±ma
Optional Event (EV) Number of output points, or points selectable functions Even type setting Event type Symbol Setting range Differential gap Remarks range Process variable PV within PV rang to U Output action Output rating Electrical life of relays Set point SP within SP limit to U Deviation DEV ±PV range/ to U U min. Absolute deviation DEV to PV span/ to U Alarm Timer to sec By remote switch input Heater burnout alarm HB. to.a to U By Optional function HB On/off SPST relay contact, Vac, Vdc, A, resistive load, times or more (7, times or more at amperes) Standby sequence Presence or absence is selectable. Heater burnout alarm Number of input point (HB) points Maximum measure- Single phase, Aac ment heater current Current indicating accuracy ±%±U Detection setting range. to 4.A Output Output relay can be EV or EV. Auxiliary output (AUX) Number of output points point Output type One type is selectable from process variable (PV), set point (SP) and control output (OUT). Output rating Output accuracy Output update cycle ms Communication Communication Communication system standard Network General Memory backup EPROM specification Rated power voltage to 4Vac, to Hz; 4Vdc Operating power voltage Power consumption Insulation resistance Dielectric strength 4 to madc. resistance: Ω max. ±.%FS (under standard conditions) RS-48 RS-C to units max. multi-dropped Peer-to-peer (slave mode only). (slave mode only). Mode Half duplex Half duplex Synchronization Start/stop Start/stop Interface system Transmission Balanced (differential) Unbalanced Type Serial Serial Signal lines transmit/receive lines transmit/receive lines Transmission, 4, 48, or bps, 4, 48, or bps speed selectable. selectable. Communication m max. m max. distance Other Conforms to RS-48 Conforms to RS-C Message character Character bits/character bits/chara configuration Format start bit, even parity, and start bit, even parity, and stop bit (standard), or start bit, stop bit (standard), or start bit, no parity, stop bits no parity, stop bits Data length 8-bits 8-bits Isolation Input and output completely isolated, except for the remote switch input. 8 to 4Vac at Hz: ±Hz at Hz: ±Hz;. to.4vdc VA max. under operating conditions. More than MΩ between the case or ground terminal and power terminal by Vdc megger. Vac, min (ac model), V min (dc model) between the case or ground terminal and power terminal. Operating conditions Operating ambient temperature to C Operating ambient humidity Vibration resistance Shock resistance to %RH.m/s max..8m/s max. Transport/storage Storage ambient temperature to 7 C conditions Storage ambient humidity to %RH Vibration resistance Shock resistance Package drop test Construction Mask: Multilon Case: Polycarbonate Colors Mask: Dark gray Case: Light gray Mounting Panel flush mount Installation Vertical plane ± Weight Approx. 4g 4.m/s max. to Hz, for hr each in X, Y and Z directions. 4m/s max., times vertically when packaged. Drop height: cm ( angle, edges, and planes, free fall)
Attachments Item Model No. Quantity Options Item Part No. Weight Unit indicating label N- sheet Hard dustproof cover 8448- Mounting bracket 844- pcs Soft dustproof cover 8448- Instruction manual CP-UM-47E book Current transformer (.8φ hole) QNA Approx. g Model Selection Guide Current transformer (φ hole) QNA Approx. g Table Types of Inputs and Ranges (Selectable at setup) Type of input Symbol C range F range Type of input Symbol C range F range Thermocouple to to Thermocouple Ni-Mo to to 7 I II III IV V Example: CDA I II III IV V Specifications Basic Control Power Optional Option ( : Included : Not included) model action supply function number C Digital controller D D G K. to 8. to 4 DIN U. to 4. to 7 A AZ D DZ. to 4. to 7 DIN L. to 8. to 4 to to RTD JIS Pt. to. to 7 J. to 8. to 4 (IEC). to.. to 4.. to 4. to 7 JIS JPt. to. to 7 E. to 8. to 4. to.. to 4. T. to 4. to 7 DC current, 4 to ma Scaling setting range R to to voltage to ma to S to to to V (Decimal point position is variable.) B to 8 to to V N to to 7 to mv PL II to to 7 to mv WRe- to to 4 to mv Time proportional PID: Relay contact Vac, A resistive load Time proportional PID: Voltage.Vdc±% Continuous PID: Current 4 to madc Resistive load: Lower than Ω 8 to 4Vac, /Hz 8 to 4Vac, /Hz apply to RT. to.4vdc. to.4vdc apply to RT Event Current Auxiliary Communications Remarks transformer output input EV EV CT AUX RS-48 RS-C 4 7 Not applicable to G type. 8 Not applicable to G type. For D type only, w/o remote switch input For D type only Standard product T K Z D B L E G F Q P Y Tropical treatment Anit-sulfidization treatment Correspondence to Zener barries Data attachment Tropical treatment inspection certificate provided Anti-sulfidization treatment inspection certificate provided Correspondence to Zener barriers Tropical treatment correspondence to Zener barriers Anti-sulfidization treatment correspondence to Zener barriers Tropical treatment correspondence to Zener barriers inspection certificate Anti-sulfidization treatment correspondence to Zener barriers inspection certificate provided Complying with the traceability certification 4
Dimensions SDC instrument (Unit: mm) Hard dust-proof cover set (option) 8448-48 Mountingg bracket 844- Terminal screw M. PV EV EV OT AT DISP OK/READY SP/EV ( X ). X 44. 4 4 7 87 MODE ENT LOADER 8 Soft dust-proof cover (option) 8448-.8 Soft dust-proof cover Hard dust-proof cover set Part No. 8448- Part No. 8448-. (.) (.). 8.. 4 (.8). Packing 8. 48.4.8 Current transformer Model QNA L K.8. K ø.8 L 7. Current transformer Model QNA L K ø. 4 K L ø. 4 4 ø. X -M Panel cutout For standard application or When hard dust-proof cover is used Lateral serial mounting with soft dust-proof cover 4. 4..8.8.8 4.7. min. Note: Ambient temperature must be 4 C max. even for side-by-side mounting. min... 48 X (N-) (48 X N-) (N: Number of mounting units)
PV input C Control output Thermocouple RTD D: Relay contact Voltage (mv, V) 7 8 7 8 Current (ma) 7 C 8 B A 7 8 Instrument power supply AC power supply 8 to 4Vac /Hz Shield GND Remote switch input (RSW) Off voltage: V V On current: ma ma DC power supply 4Vdc % 4 Common 4 7 8 7 8 D: Voltage G: Current SPDT relay contact output V ac, A, Resistive load SSR Voltage output:.v % Internal resistance:.k % Current output: 4 to madc resistance: max. Optional functions : EV, EV : EV, RS-C : AUX, RS-C 4 EV EV 4 SD 7 EV Personal computer, etc. RD 4 SD 7 AUX Receiver Personal computer, etc. RD RD 8 SD RD 8 SD SPST relay contact SPST relay contact 4 to madc Vac, resistive load Vac, resistive load resistance: max. : EV, RS-48 4: AUX, RS-48 : EV, EV, AUX Slave unit Slave unit 4 4 SDA SDB RDA 7 RDB 8 EV EV Protocol converter RDA RDB SDA SDB 4 4 SDA SDB RDA 7 RDB 8 Receiver AUX Protocol converter RDA RDB SDA SDB 4 7 8 Receiver AUX EV EV Terminal slave unit Terminal slave unit 4 SDA SDB RDA 7 RDB 8 4 SDA SDB RDA 7 RDB 8 SPST relay contact Vac, resistive load 4 to madc 4 to madc resistance: Lower than resistance: max. Terminating resistance, /W min. Terminating resistance, /W min. SPST relay contact Vac A, resistive load
Optional functions 7: EV, EV, HB 8: EV, HB, AUX : EV, HB, RS-48 : EV, HB, RS-C 4 7 8 Current transformer EV EV HB 4 7 8 Receiver AUX Current transformer EV HB 4 7 8 Terminal slave unit 7 8 EV Current transformer HB RDA RDB SDA SDB Protocol converter 4 7 8 EV Current transformer HB RD SD Personal computer, etc. SPST relay contact Vac, resistive load Unpolarized 4 to madc resistance: Ω max. SPST relay contact Vac, resistive load Unpolarized SPST relay contact Vac, resistive load Unpolarized Terminating resistance Ω /W min. SPST relay contact Vac, resistive load Unpolarized Cautions for wiring. Isolation The section bounded by a solid line () is isolated from the rest of the circuit. The section bounded by a dotted line ( the rest of the circuit. CT input PV input Remote switch input Digital circuit ) is not isolated from Current output (Control output) Current output (Auxiliary output) Voltage output (Control output) Relay output (Control output) Event output Event output Communication I/O. Power supply noise () Noise reduction techniques Always use a noise filter to suppress the influence of noise as much as possible, even if noise is unnoticeable. Instrument power supply to 4Vac Noise filter () When noise is evident If noise is observable, suppress it by using an insulation transformer and line filter. Insulation transformer Instrument / V power supply / V to 4Vac Other circuit Line filter (Azbil Corporation s model No. E87) (equivalent to TDK s ZAC-U) Ground E GND 4 Ground. Noise Possible noise sources in the installation environment are: Relays and contacts, electromagnetic coils, solenoid valves, power lines (specifically, those higher than Vac), motor commutators, phase angle control SCRs, radio equipment, welding machines, high-voltage ignition devices, etc. () Suppression techniques for quick rising noise A CR filter is effective for quick rising noise. Recommended filter: Azbil Corporation's model No. 844- (equivalent to Matsuo Electric M) () Suppression technique, for noise with large peaks: A varistor is effective for reducing noise with large peaks. However, care should be taken to avoid shorting if varistor is faulty. Recommended varistor: Azbil Corporation's model No. 844- (for Vac) No. 8447- (for Vac) 4. Grounding Ground this controller at a single point to GND terminal to 4. Don't connect any jumper wiring. Prepare a grounding terminal board separately if grounding of a shield wire is difficult. Grounding type: At least category (Ω max.) Grounding wire: Soft copper wire (AWG4) of more than mm. Grounding wire length: m max. Shield GND Terminal GND 4 At least category Grounding termnal Shield. Wiring operations () Don't bundle the primary and secondary power lines together, and don't run them in the same wiring conduit or duct after carrying out noise countermeasures. () Run the input/output and communication lines more than cm from drive power or power lines of higher than Vac. Don't run these wires in the same wiring conduit or duct.. Check after wiring After wiring, be sure to check the connecting line conditions. Be careful: incorrect wiring will cause the instrument to fail. 7
8 st Edition: Issued in May 4 8th Edition: Issued in Apr.