Overcurrent relays coordination using MATLAB model

Similar documents
Electrical Protection System Design and Operation

Busbars and lines are important elements

9 Overcurrent Protection for Phase and Earth Faults

Testing of Circuit Breaker and over Current Relay Implementation by Using MATLAB / SIMULINK

Optimum Coordination of Overcurrent Relays: GA Approach

Power System Protection Manual

Relay Coordination in the Protection of Radially- Connected Power System Network

Adaptive Relaying of Radial Distribution system with Distributed Generation

Notes 1: Introduction to Distribution Systems

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

A NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG

An Adaptive Protection Scheme for Optimal Overcurrent Relay Coordination in Interconnected Power Systems

UPGRADING SUBSTATION RELAYS TO DIGITAL RECLOSERS AND THEIR COORDINATION WITH SECTIONALIZERS

RAIDK, RAIDG, RAPDK and RACIK Phase overcurrent and earth-fault protection assemblies based on single phase measuring elements

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

Performance Analysis of Various Types of Fault Current Limiters Using PSCAD

Protection Introduction

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

6545(Print), ISSN (Online) Volume 4, Issue 3, May - June (2013), IAEME & TECHNOLOGY (IJEET)

BUS2000 Busbar Differential Protection System

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Protective Relaying for DER

Coordination of overcurrent relay using Hybrid GA- NLP method

DESIGN ANALYSIS AND REALIZATION OF MICROCONTROLLER BASED OVER CURRENT RELAY WITH IDMT CHARACTERISTICS: A PROTEUS SIMULATION

U I. Time Overcurrent Relays. Basic equation. More or less approximates thermal fuse. » Allow coordination with fuses 9/24/2018 ECE525.

Protection of Electrical Networks. Christophe Prévé

Overcurrent Protective Relays

CHAPTER 3 REVIEW OF POWER TRANSFORMER PROTECTION SCHEMES

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

Relaying 101. by: Tom Ernst GE Grid Solutions

ISSN: Page 298

Advanced Paralleling of LTC Transformers by VAR TM Method

POWER SYSTEM PRINCIPLES APPLIED IN PROTECTION PRACTICE. Professor Akhtar Kalam Victoria University

Protection of a 138/34.5 kv transformer using SEL relay

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

Earth Fault Relay EFSPL-1A/5A

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

PROTECTIVE DEVICES CO-ORDINATTION TOOLBOX ENHANCED BY AN EMBEDDED EXPERT SYSTEM - MEDIUM AND LOW VOLTAGE LEVELS

OPEN-PHASE DETECTION TECHNIQUES FOR CRITICAL STANDBY SUPPLIES

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Protection of Microgrids Using Differential Relays

POWER SYSTEM ANALYSIS TADP 641 SETTING EXAMPLE FOR OVERCURRENT RELAYS

Feeder Protection Challenges with High Penetration of Inverter Based Distributed Generation

Application of Low-Impedance 7SS601 Busbar Differential Protection

Commissioning Process and Acceptance Test of a Sub-harmonic Protection Relay

Transformer Protection

GRID CODE COMPATIBLE PROTECTION SCHEME FOR SMART GRIDS

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Generator Protection GENERATOR CONTROL AND PROTECTION

Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

IDENTIFICATION OF THE OPTIMUM PROTECTION CO-ORDINATION IN MEDIUM VOLTAGE DISTRIBUTION SYSTEM OF SRI LANKA

Micro grid Protection Using Digital Relays Mr.Karthik.P 1, Mrs.Belwin J. Brearley 2

System Protection and Control Subcommittee

NERC Protection Coordination Webinar Series June 16, Phil Tatro Jon Gardell

Negative-Sequence Based Scheme For Fault Protection in Twin Power Transformer

Focused Directional Overcurrent Elements (67P, Q and N) for DER Interconnection Protection

Line Impedance Estimation Using SCADA Data

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

Voltage Sag Mitigation by Neutral Grounding Resistance Application in Distribution System of Provincial Electricity Authority

International Journal of Advance Engineering and Research Development ANALYSIS OF INTERNAL AND EXTERNAL FAULT FOR STAR DELTA TRANSFORMER USING PSCAD

Anti-IslandingStrategyforaPVPowerPlant

A1-101 INFLUENCE OF SPECIAL SHORT CIRCUIT ON ELECTRICAL GENERATOR DESIGN. Ding Zhong MENG (HONG KONG, CHINA)

Transmission Protection Overview

Motor Protection. May 31, Tom Ernst GE Grid Solutions

POWER SYSTEM II LAB MANUAL

Application of Wavelet Transform in Power System Analysis and Protection

Transmission Line Protection Objective. General knowledge and familiarity with transmission protection schemes

Transmission System Phase Backup Protection

Differential Protection with REF 542plus Feeder Terminal

Design and Simulation of superconducting fault current limiter

Power systems Protection course

DIGITAL EARTH FAULT RELAY

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

Distribution Feeder Principles

EDS FAULT LEVELS

Voltage Sag Source Location Using Artificial Neural Network

Coordination of protective relays in MV transformer stations using EasyPower Protector software

An Effective Cable Sizing Procedure Model for Industries and Commerial Buildings

Extensive LV cable network. Figure 1: Simplified SLD of the transformer and associated LV network

TABLE OF CONTENT

THE IMPACT OF NETWORK SPLITTING ON FAULT LEVELS AND OTHER PERFORMANCE MEASURES

International Journal of Scientific & Engineering Research, Volume 4, Issue 7, July ISSN

Shortcomings of the Low impedance Restricted Earth Fault function as applied to an Auto Transformer. Anura Perera, Paul Keller

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS


UProtection Requirements. Ufor a Large scale Wind Park. Shyam Musunuri Siemens Energy

Microgrid Protection

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Novel Directional Protection Scheme for the FREEDM Smart Grid System by Nitish Sharma

OVERCURRENT RELAY COORDINATION IN DISTRIBUTION SYSTEM. (A CASE STUDY ON PHUENTSHOLING LOW VOLTAGE DISTRIBUTION NETWORK)

Overcurrent and Overload Protection of AC Machines and Power Transformers

G. KOEPPL Koeppl Power Experts Switzerland

BED INTERCONNECTION TECHNICAL REQUIREMENTS

Impact of Range of Time Multiplier Setting on Relay Coordination

ADVANCED VECTOR SHIFT ALGORITHM FOR ISLANDING DETECTION

Addendum to Instructions for Installation, Operation and Maintenance of Digitrip 3000 Protective Relays

Company Directive STANDARD TECHNIQUE: SD7F/2. Determination of Short Circuit Duty for Switchgear on the WPD Distribution System

Transcription:

JEMT 6 (2018) 8-15 ISSN 2053-3535 Overcurrent relays coordination using MATLAB model A. Akhikpemelo 1 *, M. J. E. Evbogbai 2 and M. S. Okundamiya 3 1 Department of Electrical and Electronic Engineering, Maritime Academy of Nigeria, Oron, Nigeria. 2 Department of Electrical and Electronic Engineering, Edo University, Iyamho, Edo State, Nigeria. 3 Department of Electrical and Electronic Engineering, Ambrose Alli University, Ekpoma, Edo State, Nigeria. Article History Received 16 February, 2018 Received in revised form 07 March, 2018 Accepted 12 March, 2018 Keywords: Over-current relays, Time multiplier setting (TMS), Plug setting (PS), Relay coordination, MATLAB. Article Type: Full Length Research Article ABSTRACT Proper coordination of protective relays at substation renders a significant part in the safe operation of power system. The principal aim of coordinating protective relays in a power system network is to obtain selectivity without sacrificing sensitivity and fast fault clearance time. In order to minimize outages, proper coordination of protective relays must be ensured. As a result of increased urbanization, a substantial increase in electric power demand has been recorded in recent years. But, owing to ineffective coordination of relay operation, there has been limited expansion in the system. This paper presents the design of a MATLAB Graphical User Interface (GUI) model of overcurrent relay (extremely inverse, standard inverse, and very inverse) using various characteristic equations in order to determine the parameters of the different relay. This paper further presents the relay coordination and setting for a 132/33 kv substation with a 3515.1 A short circuit current. The time multiplier setting (TMS), plug setting (PS) and actual operating time of the different relay was ascertained. 2018 BluePen Journals Ltd. All rights reserved INTRODUCTION According to Zoran and Milenko (2014), overcurrent protection represents one of the basic protections in every power system. Overcurrent and directional overcurrent relays are widely used for the protection of radial and ring sub transmission systems and distribution systems. They are also used as backup protection in transmission systems. The input signal for this protection is the root mean square (RMS) current of the protected element according to which tripping time of the relay is determined. The problem of coordinating protective relays in power system networks consists of selecting their suitable settings such that their fundamental protective function is met under the requirements of sensitivity, selectivity, reliability and speed. In modern power system, abnormal condition such as short circuit can frequently occur, thereby causing interruption in power supply, and may *Corresponding author. E-mail: abmakmur43280@gmail.com. damage the equipment connected to the power system, which allows us to think the importance of designing a reliable protective system (Vijayakumar and Neme, 2008). Relays are essential part of a power system protection and they are essential for isolating only the faulty section of the power system network, while preventing the tripping of healthy circuit and sections of the network (Reza et al., 2010). Proper coordination of protective relay plays an essential role with the power system protection scheme. Akbar and Mohsen (2011) stated that short circuit study has to be carried out at critical points in the system before embarking on relay coordination. Akbar and Mohsen (2011) further suggested a method, named linear programming and particle swarm optimization (LP- LSO) that would help to provide favorable coordination between overcurrent relays and distance relays. According to Javad et al. (2011), application of distance and overcurrent relay as main and backup relays are necessary to achieving optimal system protection in power transmission protection scheme.

J. Eng. Manuf. Technol. 9 Javad et al (2011) proposed the use of hybrid algorithm and linear programming for obtaining the relay settings which are time multiplier setting (TMS) and current setting I set for overcurrent relays and second zone time (T z2 ) for distance relays. This paper presents a study on the design of a MATLAB Graphical User Interface (GUI) model of overcurrent relay to ascertain the pick-up current, plug setting and the time multiplier setting protection coordination of over-current relays (OCRs) that will facilitate the calculation of the TMS. For an effective substation protection scheme, a time delay should be made to exist between the main and back up protection system. METHODOLOGY Overcurrent protection The protection in which the relay picks up when the magnitude of current exceeds the expected pick-up value (setting value) is known as overcurrent protection. The occurrence of a short circuit in the system usually results to a reduction in the circuit impedance and therefore a fault is accompanied by large current. Overcurrent protection is the protection from overloads. Overloading of a power system equipment means that the equipment is taking more current than its rated current and is also associated with temperature rise of the equipment whose permissible limit is based on insulation class and material problems (Akbar and Mohsen, 2011). The basic element in overcurrent protection is the overcurrent relays. The current setting multipliers of overcurrent relays generally range from 50 to 200% in steps of 25% which is referred to as plug setting (PS). Plug setting for each relay is determined by the fault current. Depending upon the time of operations, overcurrent relays may be classified as; standard inverse, very inverse and extremely inverse relay. Each characteristic can be calculated from the equation below: t = x TMS (1) Where: t = Tripping time in (s) I = Fault (actual) secondary CT current (A) I s = Relay pick-up current setting TMS = Time Multiplier Setting Standard inverse relay (SIR) These are relay whose operating time of the standard inverse relay is almost inversely proportional to the fault current near the pick-up value and becomes considerably constant slightly above the relay pick-up value. SIR (t) = x TMS (2) Very inverse relay (VIR) The very inverse types of relay are employed in feeders and long sub transmission lines protection. The relay time current characteristic is inverse over a significant time range and it tends to definite time after saturation. It is remarkably effective with ground faults due to its steep characteristics. VIR (t) = x TMS (3) Extremely inverse relay (EIR) The operating time of these relay is approximately inversely proportional to the square of the current. It is often used when fault current is dependent on fault location. EIR (t) = x TMS (4) Coordination setting The actual understanding of the fault current at each part of the power system is needed for accurate relay setting and application. Essential data needed for accurate setting of power system relay include the following; Maximum short circuit current, transformer impedance in p.u., single line diagram of the power system, and maximum peak load current. The time interval of operation between two adjacent relays depends upon a number of factors; the circuit breaker fault current interruption time, the overshoot time of the relay, variation in measuring devices errors, factors of safety. System fault study Figure 1 shows a simplified model of the system under review. The generator supplies active power P and reactive power Q to the network. A fault between all three

Akhikpemelo et al. 10 Figure 1. PSCAD model of 132/33 kv substation under review. Figure 2. Result of a single phase-to-ground fault (A-G). phases and ground (that is, ABC-G) shall be explored. The multiple-run component is used to activate the fault at different points on the voltage waveform. From Figures 2, 3 and 4, it could be observed that a three phase-to-ground fault is the most severe fault. During a three phase-to-ground fault, the entire system is unbalanced. While this type of fault does not occur frequently, its results are used for protective device selection, because this fault type generally yields the maximum short circuit current values. From Figure 4, a three phase-to-ground fault (ABC-G) of magnitude 3.5151 ka occurs at 0.51 s and last for 0.13 s. The simulation indicates the greatest fault current occurs on the 7 th fault type (Table 1). This window indicates the fault type was 7 (ABC-G), and resulted in a peak fault current of 3.5151 ka. Figure 5 shows the total fault extracted from the PSCAD multiple run output. This comprise of the following fault type; A-G, B-G, C-G, AB-G, AC-G, BC-G, ABC-G, AB, AC, and BC. It will be observed that the highest fault current of 3.515.1 ka occurred at the 7th fault type (ABC-G). Algorithm for relay coordination setting Step 1 Data extraction: line voltage, short circuit current, current transformer primary and secondary current (HV

J. Eng. Manuf. Technol. 11 Figure 3. Result of two phase-to-ground fault (AC-G). Figure 4. Result of three phase-to-ground fault (ABC-G). Figure 5. Total fault current extracted using MATLAB.

Akhikpemelo et al. 12 Table 1. Simulation results. Multiple run output Run Fault current Fault type Maximum fault 1 0.5000000000 1 2.837832029 2 0.5008333000 1 2.614030347 3 0.5016666000 1 2.305496062 4 0.5024999000 1 1.968979813 5 0.5033332000 1 1.570025179 6 0.5000000000 4 3.100306356 7 0.5016666000 4 2.435044486 8 0.5024999000 4 2.565988118 9 0.5033332000 4 2.871236302 10 0.5041665000 4 3.098755873 11 0.5091663000 7 3.471576280 12 0.5099996000 7 3.319696126 13 0.5108329000 7 3.439127165 14 0.5116662000 7 3.515149294 15 0.5124995000 7 3.475403754 and LV; CT), time graded margin and TMS. Step 2 Compute relay current (I R1 ) using Equation 1 I R1 = (1) Step 3 Compute the pickup value of relay 1 (PU 1 ) using Equation 2 PU 1 = (2) Step 4 Compute the plug setting multiplier (PSM 1 ) using Equation 3 PSM 1 = (3) Step 5 Determine relay type and calculate the time of operation using the following Equations 4, 5 and 6 T 1 = t * TMS (7) Step 7 Compute the fault current in relay (I FR2 ) in relay 2 using Equation 8 I FR2 = (8) Step 8 Compute relay current (I R2 ) in relay 2 using Equation 9 I R2 = (9) Step 9 Compute pick up setting multiplier of relay_2 (PU 2 ) using Equation 10 PU 2 = (10) Step 10 Compute Plug Setting Multiplier (PSM) of relay_2 (PSM 2 ) using Equation 11 Standard Inverse Relay = (4) PSM 2 = (11) Very Inverse = (5) Extremely Inverse = (6) Step 6 Compute the actual operation time (T 1 ) of relay 1 using Equation 7 Step 11 Determine time of operation using Step 5 Step 12 Compute the actual operating time of relay_2 (T 2 ) using Equation 12 T 2 = t * TMS + T 1 (12) Step 13 Relay coordination setting data (See Figure 6 for the protection algorithm).

J. Eng. Manuf. Technol. 13 Field Data Relay Current (I R1 ) Using Eq. 2.01 Pick Up Value (P U1 ) Using Eq. 2.02 Plug Setting Multiplier (PSM) Using Eq. 2.03 Standard Inverse No Very Inverse No Extremely Inverse Time of Operation (T) Using Eq. 2.04 Yes Yes Yes Time of Operation (T) Using Eq. 2.05 Time of Operation (T) Using Eq. 2.06 Actual Time of Operation (T α ) Using Eq. 2.07 Relay Setting Data Figure 6. Protection algorithm implemented in the overcurrent relay model. Figure 7. Extremely inverse relay co-ordination setting. RESULTS AND DISCUSSION Relay co-ordination settings are generally based on their characteristic curve, which indicates the speed of operation. The characteristics are: (1) Standard Inverse (2) Very Inverse and (3) Extremely Inverse. From Figure 7, it is observed that the operating time for PSM-1 is 2.40081 sec., operating time for PSM-2 is

Akhikpemelo et al. 14 Figure 8. Very inverse relay co-ordination setting. Figure 9. Standard inverse relay co-ordination setting. 2.40081 sec., and the actual operating time of relay-1 is 0.36012 sec, actual operating time of relay-2 is 0.96012 sec., and the TMS for relay-2 is 0.399915. From Figure 8, it is observed that the operating time for PSM-1 is 2.77864 sec., operating time for PSM-2 is 2.77864 sec., and the actual operating time of relay-1 is 0.41679 sec, actual operating time of relay-2 is 1.01680 sec., and the TMS for relay-2 is 0.36593. From Figure 9, it is observed that the operating time for PSM-1 is 3.88993 sec., operating time for PSM-2 is 3.88993 sec., and the actual operating time of relay-1 is 0.58348 sec, actual operating time of relay-2 is 1.18349 sec., and the TMS for relay-2 is 0.30424. The respective values of actual operating time and time

J. Eng. Manuf. Technol. 15 Table 2. Overcurrent relay characteristics. Characteristics Standard inverse Very inverse Extremely inverse Actual operating time of relay_2 (sec) 1.18349 1.01680 0.96012 PSM (sec) 3.88993 2.77864 2.40081 TMS (sec) 0.30424 0.36593 0.39991 multiplier settings recorded from the simulation of the different overcurrent relay characteristics are shown in Figures 7-9 and Table 2. The time of operation of these relays varies, with the extremely inverse relay the smallest, followed by the very inverse and standard inverse. It would be observed that the three relay characteristics must be considered during the relay setting. The standard inverse characteristic takes care of faults within the utility substation. The very inverse characteristic takes care of fault at the mid-point of the feeder while the extremely inverse characteristic takes care of fault at the far end of the feeder. Conclusion The relays in the power system are to be coordinated properly so as to provide primary as well as back up protection, and at the same time avoid malfunction and hence avoid the unnecessary outage of healthy part of system. In this paper, the operating time of the relays was determined using a MATLAB GUI model. Thus it can be concluded that the results obtained showed the proper coordination of the different overcurrent relay characteristics. REFERENCES Akbar A. M. B. & Mohsen P. (2011). Optimal coordination of overcurrent and distance relays by a new particle swarm optimization method. Int. J. Eng. Adv. Technol. 1(2):93-98. Javad S., Vahid A. & Mohsen B. (2011). Optimal coordination of overcurrent and distance relays with hybrid genetic algorithm. presented at the 10 th International Conference on Environment and Electrical Engineering, Rome, Italy. Reza M., Hossein A. A., Farzad R., Majid A. & Seyed H. H. S. (2010). Optimal relays coordination efficient method in interconnected power systems. J. Elect. Eng. 61(2):75-83. Vijayakumar d. & Nema R. K. (2008). A novel optimal setting for directional over-current relay coordination using particle swarm optimization. Int. J. Elect. Comput. Energ. Elect. Comm. Eng. 2(5):928-933. Zoran N. S. & Milenko B. D. (2014). Table based algorithm for inversetime overcurrent relay. J. Elect. Eng. 65(4):213-220.