Status of the PRad Experiment (E )

Similar documents
Status of the PRad Experiment (E )

Monte Carlo Simulation of the PRad Experiment at JLab 1

Status of UVa

Report of the PrimEx Readiness Review

Radiological Safety Analysis Document for the CLAS12 Engineering and the first physics run of Run Group A

Beam Loss Monitoring (BLM) System for ESS

CMS Beam Condition Monitoring Wim de Boer, Hannes Bol, Alexander Furgeri, Steffen Muller

The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

CALICE AHCAL overview

CLAS12 First Experiment Workshop Report

Hall D Report. E.Chudakov 1. PAC43, July Hall D Group Leader. E.Chudakov PAC43, July 2015 Hall D Report 1

DAQ & Electronics for the CW Beam at Jefferson Lab

The CMS Outer HCAL SiPM Upgrade.

MuLan Experiment Progress Report

Triplet polarimeter M. Dugger, March

Electronic Readout System for Belle II Imaging Time of Propagation Detector

Phase 1 upgrade of the CMS pixel detector

Performance and Operation of the CsI(Tl) Crystal Calorimeter of the BaBar Detector

Triplet polarimeter update

Detector Checkout and Optics Commissioning

X-Ray Transport, Diagnostic, & Commissioning Plans. LCLS Diagnostics and Commissioning Workshop

arxiv: v2 [physics.ins-det] 20 Oct 2008

Status of the LHCb Experiment

SIMULATION OF A SIGNAL IN THE BEAM LOSS

HPS Upgrade Proposal

The High-Voltage Monolithic Active Pixel Sensor for the Mu3e Experiment

The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO)

Uva GEM R&D Update. Nilanga Liyanage

Performance of 8-stage Multianode Photomultipliers

GEM beam test for the BESIII experiment

VUV-FEL User workshop, August 23-24, 2004

`First ep events in the Zeus micro vertex detector in 2002`

The NA62 rare kaon decay experiment Photon Veto System

BaBar and PEP II. Physics

Status of Primex Beam Position Monitor July 29 th, 2010

Main Detectors for PREX and CREX

R & D for Aerogel RICH

A tracking detector to study O(1 GeV) ν μ CC interactions

Product Range Electronic Units

The Qweak Experiment at Jefferson Lab

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

Spectrometer cavern background

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

Micromegas calorimetry R&D

Resistive Micromegas for sampling calorimetry

Current Status of ATLAS Endcap Muon Trigger System

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

1 Status of the Hall A Møller Polarimeter

HPS ECal & Trigger Simulation. HPS Collaboration Meeting.

Precision Measurement of the Proton Elastic Cross Section at High Q 2

Commissioning and operation of the CDF Silicon detector

CALICE Software. Data handling, prototype reconstruction, and physics analysis. Niels Meyer, DESY DESY DV Seminar June 29, 2009

The Trigger System of the MEG Experiment

AMS-02 Anticounter. Philip von Doetinchem I. Physics Institute B, RWTH Aachen Bad Honnef, August 2007

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration

Polarimetry Concept Based on Heavy Crystal Hadron Calorimeter

The Status of ATLAS. Xin Wu, University of Geneva On behalf of the ATLAS collaboration. X. Wu, HCP2009, Evian, 17/11/09 ATL-GEN-SLIDE

DHCAL Prototype Construction José Repond Argonne National Laboratory

Calorimeter Monitoring at DØ

Diamond sensors as beam conditions monitors in CMS and LHC

Development of LYSO detector modules for a charge-particle EDM polarimeter

Dosimetry and Position Sensing Ionization Chamber for Ion Beam Tracking

Week IX: INTERFEROMETER EXPERIMENTS

Scintillation Counters

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

1.1 The Muon Veto Detector (MUV)

Plans for RPC DHCAL Prototype. David Underwood Argonne National Laboratory

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

The LHCb Vertex Locator : Marina Artuso, Syracuse University for the VELO Group

CLAS12 FTOF Panel-1a and Panel-2 Refurbishment and Baseline Test Results

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

The trigger system of the muon spectrometer of the ALICE experiment at the LHC

Installation, Commissioning and Performance of the CMS Electromagnetic Calorimeter (ECAL) Electronics

P ILC A. Calcaterra (Resp.), L. Daniello (Tecn.), R. de Sangro, G. Finocchiaro, P. Patteri, M. Piccolo, M. Rama

arxiv: v1 [physics.ins-det] 18 Apr 2013

Triple GEM detector as beam monitor Monitors for Crystal experiment at SPS A compact Time Projection chamber with GEM

SiD Workshop RAL Apr Nigel Watson Birmingham University. Overview Testing Summary

A Prototype Amplifier-Discriminator Chip for the GLAST Silicon-Strip Tracker

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

X-ray Scanners* for ATLAS Barrel TRT Modules

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

GEM Module Design for the ILD TPC. Astrid Münnich

Norbert Meyners, DESY. LCTW 09 Orsay, Nov. 2009

VIBRATING WIRE SENSORS FOR BEAM INSTRUMENTATION Suren Arutunian

Triplet polarimeter M. Dugger, March

Unpolarized Cluster, Jet and Pellet Targets

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators

MCP-PMT status. Samo Korpar. University of Maribor and Jožef Stefan Institute, Ljubljana Super KEKB - 3st Open Meeting, 7-9 July 2009

GEM chambers for SoLID Nilanga Liyanage. University of Virginia

optimal hermeticity to reduce backgrounds in missing energy channels, especially to veto two-photon induced events.

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Pixel hybrid photon detectors

Positron Emission Tomography

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

PREX- 2 Issues. April 11, Kent Paschke

Attilio Andreazza INFN and Università di Milano for the ATLAS Collaboration The ATLAS Pixel Detector Efficiency Resolution Detector properties

Observation of X-rays generated by relativistic electrons in waveguide target mounted inside a betatron

Transcription:

Status of the PRad Experiment (E12-11-106) NC A&T State University Outline Experimental apparatus, current status Installation plan Draft run plan Summary

PRad Experimental Setup Main detectors and elements: Ø windowless H 2 gas flow target Ø PrimEx HyCal calorimeter Ø vacuum box with one thin window at HyCal end Ø X,Y GEM detector on front of HyCal Beam line equipment: Ø standard beam line elements (0.1 10 na) Ø photon tagger for HyCal calibration Ø collimator box (6.4 mm collimator for photon beam, 12.7 mm for e - beam halo clean-up ) Ø Ø Harp 2H00 pipe connecting Vacuum Window through HyCal e - beam Photon Tagger PRad Red. Review, March, 2016 2

Windowless H 2 Gas Flow Target Target chamber is differentially pumped with four high speed turbos. Kapton orifices up- and downstream from the cell reduce the beam line vacuum. A four-axis motion mechanism positions the target cell, with ±10 µm accuracy. Two solid target foils: o 1 µm carbon o 1 µm aluminum Pulse tube refrigerator Mo0on mechanism Goal parameters Length: 4 cm Temperature: 25 K Pressure: 0.6 torr Thickness: 1 x 10 18 H/cm 2 Kapton Film 27.4 µm thk 10mm Orifice Z= -803mm Z= -105mm Electron beam Upstream turbo Kapton Film 7.5 µm thk 22.8mm Orifice Z= +94mm Secondary goal: Reduce H 2 background gas! Target cell Chamber turbo (1 of 2) Kapton Film 7.5 µm thk 2mm Orifice Z= -20mm Z= +20mm Downstream turbo Kapton Film 7.5 µm thk 22.8mm Orifice Glued to a Ring of Kapton Film 27.4 µm thk 228.6 mm ID Glue Joint is concentric with orifice with a radial measurement of 12.7mm Z= +786mm

Target Status Target chamber, pumps, electronics, and all ancillary equipment are installed in Hall B Target cell fiducialized in EEL, solid target foils on hand Work Schedule: March 28 April 7: Install target cell, beam line orifices, perform H 2 tests April 8 10: Beam Commissioning mid May mid June: PRad data taking time ü Target is ready for the experiment (Thanks to Target Group). PRad Red. Review, March, 2016 4

Residual Beam Line Gas Effect (ERR Rec. #5.1) Monte Carlo simulations performed with: ü 2% of target gas distributed in [-30, +30] cm Z-interval; ü ü Events are reconstructed from the target; Each case is run 1000 times. Provided by Chao Peng without residual gas with 2% residual gas 0.911% 0.906% Relative differences between the extracted and input cross sections: σ s considered as the systematic uncertainties ü Effect of residual gas shown to be negligible. PRad Red. Review, March, 2016 5

December Helium Tests Estimate of target background gas Provided by Ch. Keith Consider 6 regions: 1. Target cell (17K) 12 mm orifice Beam 2. Upstream beam line 3. Upstream Chamber 4. Target Chamber 5. Downstream Chamber 6. Downstream beam line Region Length (cm) Pressure (torr) Thickness (cm- 2 ) Percent of total 1 4* 0.47* 1.0 e18 99.8 Dec. 2015 tests with HELIUM 2 300** 1 e-5** 1.0 e14.01 3 71* 6.6 e-5* 1.6 e14.01 Background gas reduced to approx. 0.2% of cell thickness 4 14* 1.5 e-3* 7.0 e14.03 5 71* 3.3e-4* 7.8 e14.04 6 400** 1e-5** 4.4 e14.02 * Measured ** estimated PRad Red. Review, March, 2016 6

Electromagnetic Calorimeter (PrimEx HyCal) Combination of PbWO 4 and Pb-glass detectors (118x118 cm 2 ) 34 x 34 matrix of 2.05 x 2.05 x 18 cm 3 PbWO 4 shower detectors 576 Pb-glass shower detectors (3.82x3.82x45.0 cm 3 ) 2 x 2 PbWO 4 modules removed in middle for beam passage 5.5 m from H 2 target (~0.5 sr acceptance) Moved back to Hall B in June, 2014: (thanks to Technical Group (D. Tilles and All) Ø Ø Ø Ø Ø Ø Ø Cabling system with infrastructure reassembled Trigger, analog and HV electronics are reinstalled Cooling system is operational LMS checked and repaired All individual detectors checked and repaired DAQ is operational (HyCal readout part) Transporter is reinstalled/repaired and operational PRad Red. Review, March, 2016 7

HyCal Current Status HyCal is currently up in Transporter, taking cosmic data Cosmic event in HyCal ü HyCal is ready for the experiment. HyCal in Hall B beam line (Oct, 2015) PRad Red. Review, March, 2016 8

GEM Chambers Tasks for GEM: Ø Ø Ø Ø factor of >10 improvements in coordinate resolutions similar improvements in Q 2 resolution (very important) unbiased coordinate reconstruction (including transition region) increase Q 2 range by including Pb-glass part Designed and built at UVa Both GEMs are in EEL at JLab Cosmic ray tests are in progress Talk by Kondo Gnanvo GEM chambers in EEL at JLab, March 2016 PRad Red. Review, March, 2016 9

GEM Mount on HyCal GEM chambers will be held on light aluminum frames attached to the HyCal frame Preassembled in EEL building Ready for nstallation in March, 2016 Talk by Kondo Gnanvo PRad Red. Review, March, 2016 10

Requirements to GEMs (ERR Rec. #7.2) PRad requirements for the GEM: Ø position resolution: 0.1 mm Ø detection efficiency: ~95 % ± 0.1% will be measured with cosmic rays and during the beam calibration runs Ø Uniformity of detection efficiency: with ± 0.1% will be measured with cosmic rays and accuracy during the beam calibration runs Ø Minimum material in HyCal acceptance the effect is estimated by Monte Carlo simulations PRad Red. Review, March, 2016 11

GEM Monte Carlo Simulations (ERR Rec. #7.2) Provided by Chao Peng GEANT code includes detailed information about frames Side view Front view PRad Red. Review, March, 2016 12

GEM Monte Carlo Simulations (cont d) E e =1.1 GeV Θ e =0.8 0 σ=26 MeV σ=0.0025 0 HyCal + GEM energy reconstruction E/MeV HyCal + GEM angular reconstruction σ σ(with HyCal only) = 25 MeV GEM: critical improvement in angular resolutions, without much change in energy resolutions PRad Red. Review, March, 2016 13

Vacuum Box Engineering design is done by Duke/Jlab Construction is done (March 2015) Tested with window by vendor (March 2015) Delivered to JLab (March 2015) The beam pipe connection adapter Assembled and vacuum tested at Jlab Vacuum window is installed Hydrostatically tested up to 30 psi ü see https://wiki.jlab.org/pcrewiki/index.php/ PRad_Experiment_Readiness_Review Vacuum box with window and stands is Ready for installation in March, 2016 (estimated time 2 days) PRad Red. Review, March, 2016 14

Vacuum Window Thin Al-window on Vacuum Box at the HyCal end Ø thickness: ~2 mm Ø diameter : 1.7 m Ø connected to the beam vacuum pipe in center Design and construction done at JLab e - beam Vacuum tests are done in March, 2016 (hydrostatically tested up to 30 psi) Vacuum Window is already installed on the Vacuum box. Vacuum Window Preparation of the Vacuum Window at JLab PRad Red. Review, March, 2016 15

Beam Line Elements collimator box harp target chamber collimator box is installed harp 2H00 will be installed in March/April all vacuum pipes are at JLab Beam line elements ready for installation: March 2016 Beam line change from HPS to PRad: ~ 10 days PRad Red. Review, March, 2016 16

DAQ Status (including GEM) Recent tests demonstrated < 15% dead-time for random trigger rates of 5 khz (especial thanks to Fast Electronics and DAQ groups) Talk by Kondo Gnanvo. PRad Red. Review, March, 2016 17

Required Beam Parameters Tagged Photon Beam for the setup calibration: Ø No special requirements for the tagged photon beam ü ü E e = 2.2 GeV, I e = 70 pa 1 na σ x, σ y = ~ 100 µm at the Tagger Requirements for Electron Beam: Ø very typical for Hall B with a better beam halo Quality Value Energy 1.1 and 2.2 GeV Beam current 0.1 10 na σ x, σ y ~ 100 µm Position stability ~ 100 µm Beam halo < (1x10-7 ) * Divergence < 1 mrad Luminosity ~ 10 28 cm -2 s -1 * for R > 3 mm from the beam center Photon Tagger PRad Red. Review, March, 2016 18

PRad Commissioning and Data Taking Run Plan 1) Photon Beam Tuning (~1 day): HyCal with GEM on Transporter and off the beam line; Target cell off the beam line; Tagger radiator off, collimator off; Tagger magnet on. a) establish a good electron beam (E e = 2.2 GeV, I e = 5 na) on the tagger dump; b) take electron harp scans 2C21A and 2C24A, check the position, widths and peak to tails ratio; c) study beam halo by setting the harp wire in the tail region and ramping beam current up to 100 na; d) lower beam current to 0.1 na e) insert radiator 10-5 r. l.; f) check tagger counter scalars; g) setup MOR logic for calibration (gain equalizing) trigger T5 only; Photon Tagger PRad Red. Review, March, 2016 19

PRad Run Plan: Formation of Trigger and Checkout 2) HyCal Gain Equalizing and Trigger Checkout (1.5 days): a) establish HyCal temperature to T=16 o and keep it stable; b) collimator in, 6 mm; c) target cell off the beam; d) HyCal is in Bottom Right position; e) establish a good timing with HyCal readout; f) adjust trigger delay if necessary; g) set the gain value: E=2 GeV to ADC=4000 channel; h) start the gain equalizing process: scan to each module s center, show the anode and dynode ADC distributions on computer screen, by changing the HV set anode ADC=4000 channel (with ~ 5% precision), save the HV, ADC and anode/dynode ratio; i) repeat for all HyCal modules (~10 hours). Photon Tagger PRad Red. Review, March, 2016 20

PRad Run Plan: GEM Calibration 3) GEM Beam Calibration (1.5 days, look for possibilities to combine with the item #2): 1 x1 l scintillator counters are installed in the beam line just after the Vacuum box. a) collimator with smallest diameter in (2.7 mm); b) insert thin ~ 1 µm 12 C target in the beam; c) insert radiator 10-5 r. l.; d) ask for photon beam with lowest intensity (I e = 70 pa); e) adjust the timing of the scintillator detectors vs. tagger; f) scan the GEM with HyCal with a predefined step size both on X and Y-axis, store the data from GEM, HyCal and trigger scintillator detectors; g) measure the GEM s detection efficiency vs. position (uniformity). Photon Tagger PRad Red. Review, March, 2016 21

PRad Run Plan: HyCal Gain Calibration 4) HyCal Gain Calibration (1.5 days): a) run HyCal with HV unchanged for ~ 3 hours after the Gain Equalizing ; b) the beam and the beam line are the same as in Gain Equalizing ; c) trigger: all T1-T19 tagger counters, DAQ without the sparsification ; d) start from the Top Left position with a continuous motion (~1 min/module) illuminate all modules, store the data with HyCal s X,Y positions from EPICS; e) stop the HyCal motion by the end of each row, make new DAQ run with pedestals and LMS, store the files; f) run on-line calibration programs for constants, store the data. 5) Configuration change to running configuration with HyCal on the cart, engineering survey (~4 days). Ø Request for Beam Energy Change to E e = 1.1 GeV (0.5 day) Photon Tagger PRad Red. Review, March, 2016 22

PRad Run Plan: Target Commissioning 6) Electron Beam Tuning and Target Commissioning (2 days) a) target cell off the beam line, no gas flow in the cell and chamber; b) collimator off; c) set threshold energy for the HyCal trigger E ~ 0.5xE e ; d) request electron beam (E = 1.1 GeV, I = 1 na); e) take harp scans 2C21A, 2C24A and 2H01, check position and widths, establish a good electron beam and fix the beam line parameters; f) record HyCal trigger rate with no cell and no gas flow take one short file with ADCs; g) electron beam off; insert the target cell in the beamline, still empty, ask for beam; h) target cell is empty (no gas flow into the cell and chamber); i) record HyCal trigger rate, take one short file with ADCs; j) gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); k) record HyCal trigger rate, take one short file with ADCs; l) move the cell on X-axis by +/- 3 mm with 0.2 mm steps and take HyCal rate; m) move the cell on Y-axis by +/-3 mm with 0.2 mm steps and take HyCal rate; n) change the cell angles and record the HyCal rate, get optimal cell direction; o) center the cell in beam based on those measurements; p) no gas flow into the cell and chamber, record HyCal rate; q) gas flow into the cell (P cell = 6 torr, P cham = 5 mtorr); r) record HyCal trigger rate, take one short file with ADCs; Photon Tagger PRad Red. Review, March, 2016 23

PRad Run Plan: Target Commissioning (cont d) 7) Target Commissioning (cont d): a) gas flow into the chamber only (P cell = P cham = 5 mtorr); b) record HyCal trigger rate, take one short file with ADCs (in-beam residual gas effect); c) If there is no sizable effect between cell in/out, skip following steps. d) beam off, 12.7 mm collimator in, target cell in, ask for beam; e) no gas flow in cell, record HyCal rate; f) gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr), record HyCal rate; g) beam off, insert 6.4 (?) mm collimator in, take beam and repeat items (w) and (x); h) make a decision about the size of the collimator. Photon Tagger PRad Red. Review, March, 2016 24

PRad Run Plan: Data Taking with E e = 1.1 GeV 8) Data taking with E e = 1.1 GeV (5 days) a) beam intensity: I e = 10 na; b) collimator in (with the diameter defined in 6 (z); c) HyCal trigger is set, DAQ is ready, all slow control readout is ready; d) target cell in with maximum density (2.x10 17 H/cm 3 ); e) take data for 2 days, record all information on disk and on tape; f) no gas in the cell, take data for 0.5 day (empty target run); g) gas in the cell, run for 2 days (same as in (e)); h) no gas in the cell, take data for 0.5 day (empty target run); 9) Request for Beam Energy Change to E e = 2.2 GeV (0.5 day) Photon Tagger PRad Red. Review, March, 2016 25

PRad Run Plan: Data Taking with E e = 2.2 GeV 10) Data taking with E e = 2.2 GeV (4 days) a) intensity: : I e = 10 na; b) collimator in (with the diameter defined in 5 (r); c) HyCal trigger is set, DAQ is ready, all slow control readout is ready; d) target cell in with maximum density (2.x10 17 H/cm 3 ); e) take data for 2 days, record all information on disk and on tape; f) no gas in the cell, take data for 0.5 day (empty target run); g) gas in the cell, run for 1.0 day (same as in (e); h) no gas in the cell, take data for 0.5 day (empty target run). Photon Tagger PRad Red. Review, March, 2016 26

Summary PRad experimental setup is developed, constructed and tested. It is ready for the experiment. We have addressed all Recommendations from the past ERR (thank you for your helpful comments and recommendations). DAQ is currently ready for the experiment. All systems and detectors are currently ready for installation. PRad will be ready to run from April, 2016. It is highly desirable to have a short test run before the data taking run. ü PRad is supported in part by NSF MRI award #PHY-1229153 ü my research work is supported in part by NSF awards: PHY-1506388 and PHY-0855543 PRad Red. Review, March, 2016 27

Back up slides PRad Red. Review, March, 2016 28

Beam Commissioning Run Plan (April Test Run) Goals: ü Initial test of entire apparatus with an electron beam; ü Test of the H 2 gas flow target initial performances in electron beam; ü Test of the beam halo effect on the trigger rate; ü Check the effect of the beam halo collimator on the trigger rate; ü Check and setup all timings, check the new DAQ (mostly GEM); ü Collect initial data set to test on-line and off-line monitoring codes; ü Find out weaknesses of the setup and software to prepare for May run. Experimental setup: HyCal with GEM off the Transporter on the Run Cart in the beam line and surveyed (check with engineering group); Vacuum box installed with the window; Beam line completely assembled; DAQ is ready, trigger is HyCal total sum (analog sum); Target is ready (installation was done in January, 2016). Beam: Electron beam (E e = 2.2 GeV, I e = 1 20 na, focused on the target cell). Photon Tagger PRad Red. Review, March, 2016 29

Beam Commissioning Run Plan (cont d) 1) Electron Beam Tuning (~0.5 shift): Target cell off the beam line, no gas flow in the chamber; Collimator is in the Beam Block position; Tagger radiator off the beam line; Tagger magnet on. a) establish a good electron beam (E e = 2.2 GeV, I e = 5 na) on the tagger dump; b) take electron harp scans 2C21A and 2C24A, check the position, widths and peak to tails ratio; c) study beam halo by setting the harp wire in the tail region and ramping beam current up to 100 na; d) tagger magnet off, prepare for an electron beam through the setup. Photon Tagger PRad Red. Review, March, 2016 30

Commissioning Run Plan (cont d) 2) Target Commissioning (2 shifts) a) target cell off the beam line, no gas flow in the cell and chamber; b) beam collimator in off position; c) set threshold energy for the HyCal trigger to E ~ 0.5 E e ; d) request electron beam (E = 2.2 GeV, I = 1 na); e) take harp scans 2C21A, 2C24A and 2H01, check position and widths, establish a good electron beam and fix the beam line parameters; f) record HyCal trigger rate with no cell and no gas flow take one short DAQ run (record HyCal and GEM information); g) electron beam off; insert the target cell in the beamline, still empty, ask for beam; h) target cell is empty (no gas flow into the cell and chamber); i) record HyCal trigger rate, take one short DAQ run (record all information); j) gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); k) record HyCal trigger rate, take one short DAQ run (record all information); l) move the cell on X-axis by +/- 3 mm with 0.2 mm steps and take HyCal rate; m) move the cell on Y-axis by +/-3 mm with 0.2 mm steps and take HyCal rate; n) change the cell angles and record the HyCal rate, get optimal cell direction; o) center the cell in the beam based on those measurements; p) no gas flow into the cell and chamber, record HyCal rate; q) gas flow into the cell (P cell = 6 torr, P Photon cham = 5 mtorr); Tagger r) record HyCal trigger rate, take one short DAQ run (record all information); PRad Red. Review, March, 2016 31

Commissioning Run Plan (cont d) 3) Target Commissioning with the Beam Collimators (~0.5 shift) a) electron beam off; b) 12.7 mm beam collimator in; c) target cell is empty (no gas flow into the cell and chamber); d) request electron beam (E = 2.2 GeV, I = 1 na); e) record HyCal trigger rate, take one short DAQ run; f) electron beam off; g) target cell is still off, gas flow in the chamber (P cham = 5 mtorr); h) request for beam; i) record HyCal trigger rate, take one short DAQ run (record all information); j) electron beam off; k) Insert target cell in, gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); l) request for beam; m) record HyCal trigger rate, take one short DAQ run (record all information); n) no gas flow in the cell and in the chamber; o) record HyCal trigger rate, take one short DAQ run (record all information); p) electron beam off; Photon Tagger PRad Red. Review, March, 2016 32

Commissioning Run Plan (cont d) 4) Target Commissioning with the Beam Collimator (~0.5 shift) a) electron beam off; b) 6.8 mm beam collimator in; c) target cell is empty (no gas flow into the cell and chamber); d) request electron beam (E = 2.2 GeV, I = 1 na); e) record HyCal trigger rate, take one short DAQ run; f) electron beam off; g) target cell is still off, gas flow in the chamber (P cham = 5 mtorr); h) request for beam; i) record HyCal trigger rate, take one short DAQ run (record all information); j) electron beam off; k) Insert target cell in, gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); l) request for beam; m) record HyCal trigger rate, take one short DAQ run (record all information); n) no gas flow in the cell and in the chamber; o) record HyCal trigger rate, take one short DAQ run (record all information); p) electron beam off; Photon Tagger PRad Red. Review, March, 2016 33

Commissioning Run Plan (cont d) 5) Target Commissioning with the Beam Collimator (~0.5 shift) a) electron beam off; b) 2.7 mm beam collimator in; c) target cell is empty (no gas flow into the cell and chamber); d) request electron beam (E = 2.2 GeV, I = 1 na); e) record HyCal trigger rate, take one short DAQ run; f) electron beam off; g) target cell is still off, gas flow in the chamber (P cham = 5 mtorr); h) request for beam; i) record HyCal trigger rate, take one short DAQ run (record all information); j) electron beam off; k) Insert target cell in, gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); l) request for beam; m) record HyCal trigger rate, take one short DAQ run (record all information); n) no gas flow in the cell and in the chamber; o) record HyCal trigger rate, take one short DAQ run (record all information); p) electron beam off; Photon Tagger PRad Red. Review, March, 2016 34

Commissioning Run Plan (cont d) 6) Test Runs with Different Beam Intensities and Trigger Thresholds (~2 shifts) (Runs with I e = 5 na) a) electron beam off; b) insert the optimized beam collimator; c) insert target cell in, gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); d) request electron beam (E = 2.2 GeV, I = 5 na); e) set HyCal trigger to lowest level: E ~ 0.1 E e ; f) record HyCal trigger rate, take one full DAQ run; g) no gas flow in the target (empty target run); h) record HyCal trigger rate, take one full DAQ run; i) set HyCal trigger to : E ~ 0.3 E e ; j) record HyCal trigger rate, take one full DAQ run; k) gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); l) record HyCal trigger rate, take one full DAQ run; m) set HyCal trigger to : E ~ 0.5 E e ; n) record HyCal trigger rate, take one full DAQ run; o) no gas flow in the target (empty target run); p) record HyCal trigger rate, take one full DAQ run; q) set HyCal trigger to : E ~ 0.8 E e ; r) record HyCal trigger rate, take one full DAQ run; s) gas flow in the cell (P cell = 6 torr, P cham = 5 mtorr); t) record HyCal trigger rate, take one full Photon DAQ Tagger run; PRad Red. Review, March, 2016 35

Commissioning Run Plan (cont d) 7) Test Runs with Different Beam Intensities and Trigger Thresholds (~1 shift) (Runs with I e =10 na) a) Repeat all steps in part (4) for E = 2.2 GeV, I e = 10 na) Photon Tagger PRad Red. Review, March, 2016 36

PRad Running Configuration in Hall B (suggested) Footprint of PRad setup: ~ 8.2 x 1.7 m 2 Installation in parallel with CLAS12 work/assembly in Hall B Engineering and Physics runs during evenings/nights and over weekends PRad Red. Review, March, 2016 37