*Notebook is excluded

Similar documents
* Notebook is excluded. Features KL-720 contains nine modules, including Electrocardiogram Measurement, E lectromyogram Measurement,

i Intelligent Digitize Emulated Achievement Lab

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

BME 3113, Dept. of BME Lecture on Introduction to Biosignal Processing

INVITATION FOR QUOTATION. TEQIP-II/2013/UP1G01/Shopping/43

PE Electrical Machine / Power Electronics. Power Electronics Training System. ufeatures. } List of Experiments

EE 230 Experiment 10 ECG Measurements Spring 2010

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

Rigol DG1022A Function / Arbitrary Waveform Generator

NeuVision 500. Abundant and friendly display interface, multifold ECG display screen:

5 TIPS FOR GETTING THE MOST OUT OF Your Function Generator

Bio-Potential Amplifiers


Laboratory Activities Handbook

R & D Electronics DIGITAL IC TRAINER. Model : DE-150. Feature: Object: Specification:

FUNCTION GENERATOR OPERATION MANUAL

Massachusetts Institute of Technology MIT

EECE Circuits and Signals: Biomedical Applications. Lab ECG I The Instrumentation Amplifier

Piezo Driver MTAD4002

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

Concepts to be Reviewed

Wireless Sensor Networks. EP2980

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

UNIVERSITY OF UTAH ELECTRICAL AND COMPUTER ENGINEERING DEPARTMENT ELECTROMYOGRAM (EMG) DETECTOR WITH AUDIOVISUAL OUTPUT

Robust Wrist-Type Multiple Photo-Interrupter Pulse Sensor

WRIST BAND PULSE OXIMETER

ANALOG COMMUNICATION

LINEAR IC APPLICATIONS

USB-UT350(T) Portable Ultrasonic Pulser/Receiver and Analog to Digital Converter. User s Guide

Biomedical Electrodes, Sensors, and Transducers. Definition of Biomedical Electrodes, Sensors, and Transducers. Electrode: Sensor: Transducer:

DEPARTMENT OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCE MASSACHUSETTS INSTITUTE OF TECHNOLOGY CAMBRIDGE, MASSACHUSETTS 02139

Sound Wave Measurements using an Oscilloscope and Waveform Generator

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

Low-cost photoplethysmograph solutions using the Raspberry Pi

OPVibr Ultrasonic vibration measurement system Ultrasonic vibrometer INSTRUCTION MANUAL


LIC & COMMUNICATION LAB MANUAL

multivibrator; Introduction to silicon-controlled rectifiers (SCRs).

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

On-Line Students Analog Discovery 2: Arbitrary Waveform Generator (AWG). Two channel oscilloscope

Communication System KL-910. Advanced Communication System

FREQUENCY RESPONSE OF COMMON COLLECTOR AMPLIFIER

Special-Purpose Operational Amplifier Circuits

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Notes on Experiment #1

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

Multiple Instrument Station Module

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

PHYSICS 171 UNIVERSITY PHYSICS LAB II. Experiment 4. Alternating Current Measurement

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Chapter 13 Specifications

BENG 186B Winter 2013 Final

Sonoma State University Department of Engineering Science Spring 2017

Introduction to Basic Laboratory Instruments

TAMIL NADU PUBLIC SERVICE COMMISSION. Post of Principal / Assistant Director (Training) Included in the Tamil Nadu Employment and Training Service

Facility of Engineering. Biomedical Engineering Department. Medical Electronic Lab BME (317) Post-lab Forms

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Lecture 4 Biopotential Amplifiers

Multi-function Gain-Phase Analyzer (Frequency Response Analyzer) Model 2505

Electrocardiogram (ECG)

WaveStation Function/Arbitrary Waveform Generators

Exam Booklet. Pulse Circuits

Equivalent Dual-Channel Provides Augmented Value for Customers

Agilent E2695A SMA Probe Head for InfiniiMax 1130 Series Active Oscilloscope Probes. User s Guide

Test No. 1. Introduction to Scope Measurements. Report History. University of Applied Sciences Hamburg. Last chance!! EEL2 No 1

Design of Virtual Sphygmomanometer Based on LABVIEWComparison, Reflection, Biological assets, Accounting standard.

DG4000. Series Function/Arbitrary Waveform Generator RIGOL TECHNOLOGIES, INC.

Guide to OPKUD and OPBOX Ultrasonic testing units Software Revision 3.0 / 2003

EScope Pro (P/N ESO1000) (Patent Pending)

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Introduction to Medical Electronics Industry Test Analysis and Solution

Introduction to basic laboratory instruments

Lab 1: Introduction to Electronics Measurement Equipment

WaveStation Function/Arbitrary Waveform Generators

MINUTES OF PRE BID MEETING

JorVet. Hand-Held Doppler. Operating Manual. Jorgensen Laboratories, Inc. Loveland, Colorado 80538

Laboratory 3 (drawn from lab text by Alciatore)

DG5000 Series Specifications

DG4000 Series Waveform Generators

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

ECE 2274 Lab 2. Your calculator will have a setting that will automatically generate the correct format.

AN2944 Application note

A Design Of Simple And Low Cost Heart Rate Monitor

Biomedical Signal Processing and Applications

AC LAB ECE-D ecestudy.wordpress.com

EMG click PID: MIKROE-2621

RIGOL Data Sheet. DG3000 Series Function/Arbitrary Waveform Generator DG3121A, DG3101A, DG3061A. Product Overview. Easy to Use Design.

ECE 2274 Lab 2 (Network Theorems)

APPENDIX D DISCUSSION OF ELECTRONIC INSTRUMENTS

Arbitrary/Function Generator AFG1000 Series Datasheet

EXPERIMENT 5 Bioelectric Measurements

Facility of Engineering. Biomedical Engineering Department. Medical Electronic Lab BME (317) Pre-Report Forms

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Class #9: Experiment Diodes Part II: LEDs

Transcription:

Biomedical Measurement Training System This equipment is designed for students to learn how to design specific measuring circuits and detect the basic physiological signals with practical operation. Moreover, students can understand electrical characteristics of sensor and transducer explicitly after completing the experiments we provided. *Notebook is excluded Features KL-730 contains twelve modules, including Electrocardiogram Measurement, Electromyogram Measurement, Electrooculogram Measurement, Electroencephalogram Measurement, Blood Pressure Measurement, Photoplethysmogram Measurement, Respiratory Ventilation Detection, Pulse Meter, Body Impedance Detection, Doppler Ultrasound Blood Velocity, TENS and Respiration Flow / Vital Capacity Meter. The sensors and transducers used in this equipment include pressure transducer, infrared photocoupler, strain gauge, temperature sensor, surface electrode, dual element transducer and pneumotach transducer. Each module has many test points for changing the frequency bandwidth and amplifier gain. Thus students can understand the correlation between physiological signal and each circuit stage. Display Methods of the Output Signal 1. The main unit has a 128 x 64 LCD graphic display to show the real-time physiological parameters such as heart rate, respiratory rate...etc. 2. The physiological signal can be displayed on Digital Storage Oscilloscope (DSO). 3. With the embedded 10 bits A/D converters (2.4 Kbits/s) to convert physiological signal into digital form and transmit the real-time digital signal to computer via USB port for display and storage. Graphic User Interface Software 1. Communication port : USB 2. Physiological signal can be analyzed after connection 3. Easy operation 4. X-axis : TIME/DIV ; Y-axis : VOLT/DIV 5. Data can be stored, replayed, or printed 6. Storage formats : *.BMP,*.JPEG,*.XLS 7. Analysis software available for ECG, EMG, EOG, EEG, Blood Pressure and Respiration Flow Measurement 7

Specifications Main Unit (KL-76001) 2 3 4 5 1 6 7 8 KL-76001 1. Function Generator a. Output waveform : Sine, square, triangle. b. Frequency range : 0.01 Hz ~ 1MHz, continuously adjustable c. Amplitude range : 50 mvpp ~ 18 Vpp (open circuit) d. DC offset : - 10V to + 10V 2. Interface Port USB interface : Type B 3. Input Indicators IN1 IN2 IN3 IN4 IN5 LED to lead the student connecting the sensor used for ECG, EMG, EOG, EEG and body impedance. 4. Reset Switch For MCU reset 5. Select Switch Select the module 9 6. LCD Status Display a. Display the frequency of function generator b. Display the measurement modules: Electrocardiogram measurement, Electromyogram measurement, Electrooculogram measurement, Electroencephalogram measurement, Blood pressure measurement, Photoplethysmogram measurement,respiratory ventilation detection, Pulse meter, Body impedance detection, Doppler Ultrasound Blood Velocity, TENS, Respiration Flow / Vital Capacity Meter. c. Heart Rate(KL-75006), Respiration(KL-75007), Pulse Rate (KL-75008) and Doppler Ultrasound Blood(KL-75010). 7. BNC Adaptor Connector For 2mm socket / BNC socket 8. Module Output DB9 connector 9. Output a. Electrocardiogram (ECG) : One output b. Electromyogram (EMG) : Two outputs c. Electrooculogram (EOG) : Two outputs d. Electroencephalogram (EEG) : One output e. Blood pressure measurement : Two outputs f. Photoplethysmogram : Two outputs g. Respiratory ventilation : Two outputs h. Pulse meter : Two outputs i. Impedance : One output j. Doppler Ultrasound Blood Velocity : Two outputs k. TENS : One output l. Respiration Flow/Vital Capacity Meter: Two outputs Module Units (KL-75001~75012) KL-75001 Electrocardiogram ECG Module Understand the phenomenon of the action potential when heart beats. This measurement module uses six limb leads to detect the electrocardiogram. With the explicit experimental procedure, students learn how to design the Wilson network and the isolated circuits easily. 1. Limb lead inputs 2. Limb electrode 3. Six limb leads : Lead I, Lead II, Lead III, av R, av L, av F 4. Isolation circuit 5. Gain : 100~5000 6. Band-pass filter : 0.1~100 Hz 7. One output ECG signal 1. HPF Characteristic 2. Amplifier 3. LPF Characteristic 4. BRF Characteristic 5. ECG Simulator (Optional) 6. ECG 2. KL-75001 Electrocardiogram Module 4. Lead Clamp - 6 6. 5-Conductor Electrode Cable - 18 8. Trimmer 9. Connection Leads - 20 10. 2mm Bridging Plug - 21 11. 2mm Terminal - 22 12. KL-79106ECG Simulator (Option) 8

KL-75002 Electromyogram EMG Module Comprehend the electrical activity of muscle under the isotonic and isometric conditions and simultaneously detect the amount of muscle force. From the measured waveform, students can realize the motion function made by the skeletal muscle specific. 1. Surface electrode 2. Gain : x 1000, x 2000 3. Isolation circuit 4. Band-pass filter : 100 ~1000 Hz a. Electromyogram signal b. Muscle force signal 1. BRF Characteristic 2. LPF Characteristic 3. Gain Amplifier 4. HPF Characteristic 5. Half-Wave Rectifier Characteristic 6. Integrator Characteristic 7. EMG 2. KL-75002 Electromyogram Module 4. Body Surface Electrodes - 8 6. 5-Conductor Electrode Cable - 8. Dumbbell (5kg) - 1 9. Trimmer 10. Connection Leads - 11. 2mm Bridging Plug - 12. 2mm Terminal - 22 20 21 18 KL-75003 Electrooculogram EOG Module Have a through grasp of the electrical activity of the eye muscle under eye movements. Two kinds of electrical signal from horizontal and vertical movements of the eye ball are detected and processed in the module. 1. Surface electrode 2. Gain : 5~3000 3. Isolation circuit 4. Band-pass filter : 0.05~30 Hz a. Horizontal signal b. Vertical signal 1. Horizontal & Vertical Electro Circuit Calibration 2. BRF Characteristic 3. HPF Characteristic 4. Amplifier 5. LPF Characteristic 6. EOG 2. KL-75003 Electrooculogram Module 4. Body Surface Electrodes - 8 6. 5-Conductor Electrode Cable - 18 8. Trimmer 9. Connection Leads - 20 10. 2mm Bridging Plug - 21 11. 2mm Terminal - 22 KL-75004 Electroencephalogram EEG Module Understand the electrical activity of the brain. In the experimental procedure, theα-wave will be evoked when the eyes open and close. Because the EEG signal is very weak, this module implements a high gain amplifier and filters to avoid the noise. Specifications 1. EEG electrode 2. Gain : 50~5000 3. Isolation circuit 4. Band-pass filter : 1~20 Hz 5. One output EEG signal List of s 1. Pre-Amplifier Calibration 2. BRF Characteristic 3. HPF Characteristic 4. Amplifier 5. LPF Characteristic 6. EEG Equipment Required 2. KL-75004 Electroencephalogram Module 4. EEG Electrode - 16 5. 5-Conductor Electrode Cable - 18 6. Alcohol Prep. Pad -11 7. Electrical Conductivity Jelly - 2 8. Medical Tape - 10 9. Elastic Head Bandage - 9 10. Trimmer 11. Connection Leads - 20 12. 2mm Bridging Plug - 21 13. 2mm Terminal - 22 14. EEG Simulator (Option) 9

KL-75005 Blood Pressure Measurement Module Realize how to measure the blood pressure noninvasively and compare its accuracy with the auscultator and oscillometric method. In this experiment, students know the way to calibrate the pressure transducer directly and indirectly. 1. Pressure transducer: a. Differential pressure model b. Pressure range : 0~5 psid c. Accuracy : 0.5 % d. Input impedance : 5KΩ 2. Pressure calibration circuit 3. Gain amplifier: 20~800 4. Band-pass filter : 0.3~3 Hz a. Cuff pressure signal b. Oscillometric pulse signal 1. Pressure Sensor Calibration 2. HPF1 Characteristic 3. LPF Characteristic 4. HPF2 & Amplifier Characteristic 5. Rectifier Characteristic 6. Auscultatory Blood Pressure measurement 7. Oscillometric Blood Pressure Measurement 2. KL-75005 Blood Pressure Measurement Module 4. Mechanical Sphygmomanometer - 4 KL-75006 Photoplethysmogram Module See how to use the noninvasive method and configure the circuit to detect and process the Plethysmogram. The volume change of blood capillary is detectable by an infrared photocoupler. 1. Infrared light-emitting diode a. Rated forward current IF = 60 ma b. Rated reverse voltage VR = 4 V c. Peak wavelength λp = 880 nm d. Δθ = ± 53 deg 2. Phototransistor a. Rated C-E voltage VCEO = 20 V b. Rated collector power Pc = 75 mw c. Peak wavelength λp = 800 nm d. Δθ = ± 50 deg. 3. Gain : x 50~500, x 100~1000 4. Band-pass filter : 0.3~40 Hz a. Plethysmogram signal b. Heart rate pulse 1. Infrared Photocoupler Calibration 2. HPF Characteristic 3. Gain Amplifier 4. 4th-order LPF Characteristic 5. Differentiator 6. Amplifier 7. Comparator 8. Monostable Multivibrator 9. Photoplethysmogram Measurement 2. KL-75006 Photoplethysmogram Module 4. Infrared Photocoupler Sensor - 13 10

KL-75007 Respiratory Ventilation Module To learn the usage of temperature sensor and circuit configuration, users can comprehend how to detect and process the respiratory signal including stop breathing capacity, over-respiration and respiratory rate. 1. Temperature sensor a. Thermister : 5K Ω (at 25 C) b. Tolerance : ± 5% 2. With temperature compensation circuit 3. Gain : 20 4. Two outputs a. Pneumograph signal b. Respiratory rate pulse 1. Differential Amplifier Calibration 2. BRF Characteristic 3. Amplifier 4. Differentiator 5. Hysteresis Comparator 6. Monostable Multivibrator 7. Respiratory Ventilation Detection 2. KL-75007 Respiratory Ventilation Module 4. Temperature Sensor Mask - 7 6. Alcohol Prep. Pad - 11 7. Connection Leads - 20 8. 2mm Bridging Plug - 21 9. 2mm Terminal - 22 KL-75008 Pulse Meter Module Understand how to use the strain gauge and configure the circuit for detecting and processing the radial pulse waveform and learn vascular characteristics under different Transmural pressure conditions. 1. Strain gauge 5 mm grid, 120Ω 2. Gain : x 2500, x 5000 3. Band-pass filter : 0.05 ~ 40 Hz 4. Two outputs a. Pulse wave b. Heart rate pulse 1. Strain Gauge Amplifier Calibration 2. HPF Characteristic 3. BRF Characteristic 4. Gain Amplifier 5. LPF Characteristic 6. Hysteresis Comparator 7. Monostable Multivibrator 8. Pulse Meter 9. Arterial Vessel 2. KL-75008 Pulse Meter Module 4. Strain Gauge Tie - 12 5. Wrist-type Cuff - 5 6. Mechanical Sphygmomanometer - 4 7. Trimmer 8. Connection Leads - 20 9. 2mm Bridging Plug - 21 10. 2mm Terminal - 22 KL-75009 Impedance Module (People with cardiac pacemaker must avoid using this) Realize how to detect the body impedance. Injecting a constant alternating current to the body and passing through the chest, a change of body impedance will be detected when chamber volume of the ventricle and atrium is changed. 1. Band-pass filter : 0.1~10Hz 2. Sine wave generator circuit : 50 KHz 3. Surface electrode 4. Isolation circuit 5. Gain : x 1250, x 2500 6. With overcurrent protection and reset circuits 7. One output Body impedance signal 1. Pre-Amplifier Calibration 2. BRF Characteristic 3. Wien-Bridge Oscillator 4. HPF Characteristic 5. Demodulator 6. Gain Amplifier 7. LPF Characteristic 8. Impedance Detection 2. KL-75009 Impedance Module 4. Body Surface Electrodes - 8 6. 5-Conductor Electrode Cable - 18 8. Trimmer 9. Connection Leads - 20 10. 2mm Bridging Plug - 21 11. 2mm Terminal - 22 11

KL-75010 Doppler Ultrasound Blood Velocity Module Aims to enable students to understand the principle of ultrasonic sensor, and the theory about the ultrasound probe how to measure the blood flow velocity and basic circuit theory. 1. Dual Element Transducer Frequency : 5MHz 2. Gain : 16~100 3. Band-pass filter : 1~40Hz 4. Two Output a. Plethysmogram signal b. Heart rate pulse 1. OSC 2. Pre-Amplifier 3. Demodulation 4. HPF Characteristic 5. Amplifier 6. LPF Characteristic 7. Comparator 8. Monostable Multivibrator 2. KL-75010 Doppler ultrasound blood velocity module 4. Dual Element Transducers Sensor - 23 6. Alcohol Prep. Pad - 11 7. Connection Leads - 20 8. 2mm Bridging Plug - 21 9. 2mm Terminal - 22 10. Electrical conductivity jelly - 2 KL-75011 TENS Module (People with cardiac pacemaker must avoid using this) Aims to enable students to understand the basic circuit theory of transcutaneous electrical nerve stimulation (TENS) and the physiological responses of muscles which are stimulated by the different frequency and amplitude. 1. Electrode lead 2. One Output 555 Timer-Astable signal a. Frequency Adjust : 25~115Hz b. Duty Cycle : 91~98% 1. 555 Timer-Astable 2. Transistor Switch Circuit 3. Transistor Bias Circuit 2. KL-75011 TENS module 4. Body surface electrodes (for KL-75011) - 5. Electrode lead (for KL-75011) - 15 14 KL-75012 Respiration Flow/ Vital Capacity Meter Module Aims to enable students to understand the respiratory parameters, including the physiological principles of respiratory volume and flow, and the measurement of the basic circuit. 1. Pneumotach transducer a. Excitation voltage : 6V b. Flow range: 2-35 L/min c. Resolution : 700P/L d. Maximum operation pressure : 25 Bar 2. Two Output a. Respiration flow signal b. Counting pulse 1. Hall & Differential 2. Frequency to Voltage 3. Comparator 4. AND Gate 5. Decade Counter 6. Decoder 7. 7-Segment 2. KL-75012 Respiration flow/vital capacity meter module 4. Respiration transducer - 19 12

Module Features 1. All terminals on the module accepts 2mm plugs. 2. Circuit symbols, blocks and components are printed on the surface of each module. 3. Modules are secured in plastic housings. 4. Dimension : 255x165x30mm ± 10% 5. With storage cabinet for easy storing 6. Comprehensive experiment and instructor's manuals are provided. Accessories Optional Accessories 1. Digital Storage Oscilloscope (DSO) 2. KL-79106 ECG simulator 3. EEG simulator 4. Electrical conductivity jelly 5. Body surface electrode Standard Accessories (KL-79003) 6. Alcohol prep pad 7. Elastic head bandage 8. Temperature sensor mask 9. Medical tape 10. Body surface electrode(for KL-75011) Digital Storage Oscilloscope NOTE : Since item No. 4 to 10 are consumables, the order quantity depends on user s choice. KL-79106 ECG simulator EEG simulator (Pathological Signals) 4 1 5 2 3 1 Dumbbell 2 Electrical conductivity jelly 3 Accessory box 4 Mechanical sphygmomanometer 5 Wrist-type cuff 7 8 9 6 10 11 6 Lead clamp 7 Temperature sensor mask 8 Body surface electrodes 9 Elastic head bandage 10 Medical tape 11 Alcohol prep pad 12 Strain gauge tie 13 Infrared photocoupler sensor 14 Body surface electrode for KL-75011 12 13 14 15 15 Electrode lead for KL-75011 16 EEG electrode 17 Electrode lead 18 5-conductor electrode cable 19 Respiration transducer 20 Connection leads 21 2mm bridging plug 22 2mm terminal 23 Dual Element transducer 16 20 17 18 19 21 22 23 10301 13