GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network

Similar documents
SolarEdge Feed-in Limitation Application Note

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

The I-2532 CAN to Fiber Converter

SolarEdge Feed-in Limitation Application Note

ACC-6SMRP2U Data Sheet

Installation Guide Multi Position Servo Controller E1100-MP and E1100-MP-HC

PROFIBUS HUB REPEATER

M-Bus Master MultiPort 250L Installation and User Guide

Modbus communication module for TCX2: AEX-MOD

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MPS PROFIBUS-DP INTERFACE

Wireless Data Gathering Panel MODEL TS0825

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

Disclaimers. Important Notice

Answering frequently asked Questions (Firmware V.107)

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

Disclaimers. Important Notice

PULSE INPUT MODULE PI232/PI272 USER S MANUAL

PHYTER 100 Base-TX Reference Clock Jitter Tolerance

Installation and Operation Manual HS-R. 4-Channel Low Speed Data Module with V.110 Rate Adaptation MEGAPLEX-2100 MODULE

E35C. AD-FG/CG/GG Version 3.2. Technical Data. Communication Module Residential

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

SolarEdge Export Limitation Application Note

10/100Base. 100Base-FX Switching Converter. User s Manual

MD12-2 Metal Loop Detector

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

Wireless Transceiver - Bell & Tone Scheduling Troubleshooting Guide

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MGL Avionics Garrecht VT-0102 mode-s transponder Interface installation manual

Product Manual. HIPERFACE DSL (HDSL) for the ARS 2000 FS series servo drives

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

The modular system for communication, alerting and people search

MAI-4. Technical Documentation Analog Input Submodule. Please keep for further use!

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

AcuMesh Wireless RS485 Network. User's Manual SOLUTION

BATTERY MANAGEMENT SYSTEM 4 15S

Contents. Warranty and Disclaimer 2 Introduction 3

IntelPage 5W (POCSAG) Transmitter

CONNECTING THE PROBE TO THE TEST INSTRUMENT

The i-7531 CAN Repeater

BATTERY MONITOR User Manual

Arc Sensor User Manual

Wall Mounted E-BUS CO 2. Sensor Technical Guide

USB-PWM10. User s Manual

Application Note Series. Solutions for Production Testing of Connectors

SET Installation and Operating Instructions. Level switch for two sensors

DRG-Series. Digital Radio Gateway. Tait P25 CCDI Tier-2 (TM9400 Series Mobile Radio) Digital Radio Supplement

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

PWM 180-Pin Probing Board Manual

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Electronic Load ZSAC

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

PROFINET USER S GUIDE ACSI Servo

Modular Radio Telemetry System

KRONOsync Transmitter System Operations Guide

PHY Layout APPLICATION REPORT: SLLA020. Ron Raybarman Burke S. Henehan 1394 Applications Group

AAA. Figure 1: Test setup for output power measurement

Connecting Mains Electrical Power

SA-320 Installation Guide SA-320. Installation Guide. Date: Mar, 2011 Version: 2.5. All Rights Reserved

Hardware Guide. Control Made Simple. Model 401A Signal Generator

M O D U L E - 7 D Model CS-CAL/DLIU V6.0 Operator s Manual

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

Blue Point Engineering

Modular Radio Telemetry System

User Manual CTP4/8/16

LIN Bus Shunt. Slave Node Position Detection. Revision 1.0. LIN Consortium, LIN is a registered Trademark. All rights reserved.

ST600 TRANSMITTER OPERATING INSTRUCTIONS

KMT - Kraus Messtechnik GmbH

1.0 Introduction. Related Products and Documentation

Z-5652 plus Series. 2D Image Hands-Free Scanner

QuickBuilder PID Reference

Module Type Controller SRX. Communication Instruction Manual IMS01N01-E6 RKC INSTRUMENT INC.

WiNRADiO WR-G35DDCi Multichannel Coherent Application Guide

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER

PHALCON 2000 Installation Guide

Acoustic Emission Preamplifiers Specification

Specification for Lightning Sensor

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD-F18 Hydraulic-Series. Key-Features:

MICROWAVE BRIX SENSOR. onexis automations pvt ltd

CAN Repeater. CRep S4.../S24/RMD. User Manual. Thomas Wünsche

BATTERY MANAGEMENT SYSTEM REC 7-R

ELECTRONICA Modular thyristor firing board. CONTROL OPTIONS External 4k7 Ω potentiometer 0-10 VDC analog signal

Debugging a Boundary-Scan I 2 C Script Test with the BusPro - I and I2C Exerciser Software: A Case Study

B. Equipment. Advanced Lab

2.64 Gbit/s Serial Link Piggyback Board

UNIGYR Building Level Network, PROFIBUS X1 V1 E4

IP1 Datasheet PWM OUTPUT WITH SINGLE CHANNEL ADC MODULE FEATURES DESCRIPTION CONNECTOR DETAILS

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

Hytera DMR Conventional Series

Important safety instructions

Ranges >500 mm: L10 = ±0.10 % f.s. L02 = ±0.02 % f.s. Ranges 500 mm: L10 = ±0.5 mm L02MM = ±0.2 mm Repeatability ±3 µm

Transcription:

GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network GeoSIG Ltd, Ahornweg 5A, 5504 Othmarsingen, Switzerland Phone: + 41 44 810 2150, Fax: + 41 44 810 2350 info@geosig.com, www.geosig.com

Page ii GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Document Revision Author Checked Approved Markus Epp Version V1-10.11.2010 Action First release (MAE) Disclaimer GeoSIG Ltd reserves the right to change the information contained in this document without notice. While the information contained herein is assumed to be accurate, GeoSIG Ltd. assumes no responsibility for any errors or omissions. Copyright Notice No part of this document may be reproduced without the prior written consent of GeoSIG Ltd The software described in this document is furnished under a license and may only be used or copied in accordance with the terms of such a license. Trademark All brand and product names mentioned are trademarks or registered trademarks of their respective holders. All rights reserved. GeoSIG Ltd. Switzerland

GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Page iii Table of Contents 1. Introduction... 4 1.1. Common Timing...4 1.1.1. Time Master Instrument...4 1.1.2. Time Slave Instruments...4 1.2. Common Trigger...4 2. Installation... 5 2.1. Overview...5 2.2. Connection to the Instrument...6 2.3. Connection to the Interconnection BUS...6 2.3.1. Cabling...7 2.3.2. Earthing...7 2.3.3. Termination of the BUS...7 2.3.4. Interconnection Cable...8 3. Configuration... 8 3.1. Common Time...8 3.2. Common Trigger...10 Appendix A. Assembly Instructions for Cable Glands with Shield... 11

Page 4/11 GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 1. Introduction If several instruments with internal or external sensors are placed on site, they can be interconnected with one cable while galvanically isolated from each other. For convenient cabling and advanced over voltage protection external junction boxes are supplied. The interconnection between the stations is carried out in a BUS topology. Distances between the two most fare located stations can be as much as 1.3 km. This is a favourable and cost effective solution for many applications. a This Interconnection Network covers common time and common trigger only. In case data transfer should be handled over the interconnection network as well, please contact GeoSIG Ltd. 1.1. Common Time One of the interconnected instruments normally is connected to GPS or NTP for accurate timing (hereafter called Time Master Instrument). This instrument synchronise its internal clock to the GPS or NTP server and provides an accurate timing signal to all other instruments connected to the network (hereafter called Time Slave Instruments). 1.1.1. Time Master Instrument The Time Master Instrument can be any instrument in the BUS, so it does not have to be the first or last instrument in the chain. The Timing Master Instrument must be connected to a GPS or NTP server for accurate timing. Additionally this instrument must be configured as described in chapter 3.1. 1.1.2. Time Slave Instruments All the Time Slave Instruments synchronise its internal clock to the accurate time signal, distributed by the Time Master Instrument. These instruments within the network permanently check their synchronisation status. In case of not having the network time information available, the Time Slave Instruments base on their internal clock. These instruments must be configured as described in chapter 3.1. 1.2. Common Trigger Generally spoken it can be said that the interconnection network allows activating the event recording on all instruments in the network in case just one instrument triggers. Triggering functionality of each recorder can be controlled using the configuration options Be a source of network triggers and Activate on network triggers. By enabling or disabling these functionalities the behaviour of each instrument can be defined precisely as needed in the particular application. This functionality can be summarised as following, for detail settings see chapter 3.2: Be a source of network triggers: It can be selected if the instrument transmits an active trigger message to the network if an internal trigger condition is fulfilled. Activate on network triggers: It can be selected if the instrument triggers on an active trigger message arriving from the network. Record on network triggers only: It can be selected if the instrument should record on network triggers only and ignore all internal triggers.

GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Page 5/11 2. Installation 2.1. Overview The Interconnection Junction Boxes are supplied in order to facilitate on-site wiring. Since these networks can extend over hundreds of meters involving long cables the Interconnection Junction Box provides additionally advanced protection against over-voltages, such as electrostatic discharges and lightning, and differences in local earth potentials. The protection is realised in the following ways. Advanced Lightning and over-voltage protection is implemented in the Interconnection Junction Box. An interconnection option board which takes care of the galvanic isolation is installed in the instruments. Figure 1 shows the Interconnection Junction Box which is used along with each recorder. Figure 1. Interconnection Junction Box (150 x 150 x 80 mm) The interconnection wiring is site-specific and normally carried out by the customer. The wiring of the interconnection cable is straight through which makes installation easy. In order to achieve a maximum protection and system reliability, a couple of points are important to take care during installation. This is mainly in relation with earth and cable shield connections and described in the following chapters.

Page 6/11 GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 2.2. Connection to the Instrument The instrument is connected to the Interconnection Junction Box over the INTERCON connector on the front of the instrument. The related cable with a length of approximately 2 m is already mounted on the Interconnection Junction Box and can be easily plugged to the instrument. It s important that both the instrument and the junction box are connected to local earth. There is an earth screw on the Interconnection Junction Box and the base plate of the instrument which can be used for this purpose. The earth cable should be connected first to the Interconnection Junction Box and then goes on to the instrument. See Figure 2 for details. GMS-xx OPTION Interconnection INTERCON plug To the previous instrument Junction Box To the next instrument Cable shield Cable shield Local Protection- Earth Figure 2. Wiring, including Interconnection Junction Box 2.3. Connection to the Interconnection BUS Each instrument is connected to the BUS cable via the Interconnection Junction Box as described in chapter 2.2. The setup looks as shown below: Last Instrument N Instruments between First Instrument GPS Termination Termination Figure 3. Interconnection BUS

GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Page 7/11 2.3.1. Cabling The cable coming from the previous Interconnection Junction Box and the cable going to the next one are connected as indicated below. Terminator, see chapter 2.3.3 To the instrument BUS to previous Junction Box 8 7 6 5 4 3 2 1 See Appendix A BUS to next Junction Box 8 7 6 5 4 3 2 1 Cable shields from the BUS Figure 4. Connectors inside Junction Box Pin Function 1 st Box 2 nd Box n Box 1 ----------- 1 ----------- 1 ----- Trigger + (RS-485) 2 ----------- 2 ----------- 2 ----- Trigger - (RS-485) 3 ----------- 3 ----------- 3 ----- Time + (RS-485) 4 ----------- 4 ----------- 4 ----- Time - (RS-485) 7 ----------- 7 ----------- 7 ----- GND (optional) No crossing of the cables is needed at any place. The wire from Pin 1 will always go to the Pin 1 of the next Interconnection Junction Box. Pin 2 to Pin 2 and so on 2.3.2. Earthing All Interconnection Junction Boxes and Instruments must be properly connected to the local earth. The cable shield must be connected to the earth on one location only to avoid a ground loop on the cable. Therefore inside all Interconnection Junction Boxes the cable shield must be connected to the provided cable socket with one exception: In one (1!) Interconnection Junction Box the cable shield must be connected to the housing as described in Appendix A. For all others use the internal cable socket. For details see Figure 5 on the right side. 2.3.3. Termination of the BUS Figure 5. Bus cabling Figure 6. Termination Connector In the first and the last Interconnection Junction Box on the BUS a terminal plug (see Figure 6) must be connected to the free connector. See also blue boxes in Figure 5 on the right side.

Page 8/11 GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 2.3.4. Interconnection Cable The appropriate choice of the interconnection cable is important for the functionality of the network. For all network types the cable has to have twisted-pairs and a shield in order to prevent it from picking up interference. Another important aspect is the diameter required which is a trade off between total length of the bus network and cable diameter. Maximum total cable resistance (both ways) is 2 * 50 Ohm. Table 1 shows the relationship between cable cross-sections and maximum network lengths. Table 1. Cable cross-sections vs. maximum network length Cross-section [mm 2 ] Resistance [Ohm/km] Maximum network length [m] 0.20 89.0 500 0.25 71.2 700 0.35 50.9 900 0.5 36.6 1300 A way to reduce the cable resistance is to connect two pairs in parallel. This effectively reduces the resistance by factor two and doubles the maximum length. a In case if the interconnection network is planned to be longer than 1300 m please contact GeoSIG for assistance. 3. Configuration The instrument must be set up according to the GS_GMS-xx_UserManual_Vxx.doc (Version V06 or higher) so that the communication is established and parameters can be changed. The following chapters just guide through the settings in relation with the interconnection network. For any other adjustments consult the GMS-xx User Manual. 3.1. Common Time Press O to select the Miscellaneous Parameters menu. Main Menu A) Station description... Demo GMS-18 B) Station code... DEMO C) Location description... GSO D) Seismic network code... CH E) Number of Channels... 3 F) Number of Output Streams... 1 G) Number of Trigger Sets... 1 H) Number of Preset Triggers... 1 I) Channel Parameters... -> J) Stream Parameters... -> K) Trigger Parameters... -> L) Parameters of Preset Triggers... -> M) File Storage and Policy... -> N) Communication Parameters... -> O) Miscellaneous Parameters... -> P) Auxiliary Devices... -> Then press I to get to the Time synchronisation menu to adjust the settings of the time synchronisation.

GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Page 9/11 Main Menu Miscellaneous A) Offset detection time, sec... 10 (0x0A) B) Offset correction time, sec... 0 (0x00) C) Offset correction counts... 1 (0x01) D) Active signal simulator... No E) MiniSEED record length... 512 F) State of health... -> G) Test configuration... -> H) Messaging and debugging... -> I) Time synchronization... -> J) Instrument configuration options... -> K) Time for sending daily logfile, hour... 0 (0x00) L) Time for sending daily logfile, minute... 0 (0x00) The following menu appears: Main Menu Miscellaneous Time Synchronization A) Time source... RTC K) RTC watchdog timeout, sec... 600 (0x258) L) Send SOH upon RTC status change... No Adjust the following parameter: Time source RTC Internal clock is not synchronizing itself to any source Instrument acts as Time Master Instrument GPS Internal clock is synchronizing to the connected GPS NTP Internal clock is synchronizing to a NTP server AUTO Internal clock synchronizes to NTP in case GPS is not available NET1PPS Internal clock is synchronizing to the time signal distributed by the Time Master Instrument over the interconnection network. Instrument acts as Time Slave Instrument a Make sure that only one instrument in the interconnection network is configured as Time Master Instrument. All others must be configured as Time Slave Instruments.

Page 10/11 GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 3.2. Common Trigger Press G to select the Number of Trigger Sets and make sure that there is at minimum one trigger set Main Menu A) Station description... Demo GMS-18 B) Station code... DEMO C) Location description... GSO D) Seismic network code... CH E) Number of Channels... 3 F) Number of Output Streams... 1 G) Number of Trigger Sets... 1 H) Number of Preset Triggers... 1 I) Channel Parameters... -> J) Stream Parameters... -> K) Trigger Parameters... -> L) Parameters of Preset Triggers... -> M) File Storage and Policy... -> N) Communication Parameters... -> O) Miscellaneous Parameters... -> P) Auxiliary Devices... -> Press K to get to the Trigger Parameters menu to adjust the settings of the triggers. The following menu appears. In case the number of trigger sets is set to 0 this menu can not be selected. Main Menu Triggerset A) Triggerset name... Trigger1 B) Event recording... No D) Alarm activation... No E) SMS Alarm... No I) Trigger time frame, sec... 3 (0x03) K) Monitored channels... 3 L) Trigger settings... -> O) Be a source of network triggers (received from LAN)... No P) Activate on network triggers (received from LAN)... No Q) Be a source of network triggers (Interconnection)... No R) Activate on network triggers (Interconnection)... No Adjust the following parameters according to your set up: Be a source of network triggers (Interconnection) Activate on network triggers (Interconnection) Yes No Yes No It can be selected, if all the other instruments in the interconnection network should be alerted in case of a local trigger. It can be selected if the instrument should trigger in case it will be alerted over the interconnection network from any other instrument. a Each trigger set can be adjusted according to your wishes. To change the trigger set press + or -.

GS_GMS-xx_UserManual_App_Interconnection_V01.doc / 10.11.2010 Page 11/11 Appendix A. Assembly Instructions for Cable Glands with Shield a The cable shield should be connected to the housing on one (1!) Interconnection Junction Box only. For all others the internal cable socket must be used. For more information please see video at: http://www.agro.ch/global/images/flashes/start_en.swf