F. Hartmann. IEKP - Universität Karlsruhe (TH) IEKP - Universität Karlsruhe (TH)

Similar documents
ATLAS Upgrade SSD. ATLAS Upgrade SSD. Specifications of Electrical Measurements on SSD. Specifications of Electrical Measurements on SSD

Silicon Sensor Developments for the CMS Tracker Upgrade

SSD Development for the ATLAS Upgrade Tracker


CMS Phase II Tracker Upgrade GRK-Workshop in Bad Liebenzell

Why p-type is better than n-type? or Electric field in heavily irradiated silicon detectors

CMS Tracker Upgrade for HL-LHC Sensors R&D. Hadi Behnamian, IPM On behalf of CMS Tracker Collaboration

Radiation hardness and precision timing study of Silicon Detectors for the CMS High Granularity Calorimeter (HGC)

Signal-to. to-noise with SiGe. 7 th RD50 Workshop CERN. Hartmut F.-W. Sadrozinski. SCIPP UC Santa Cruz. Signal-to-Noise, SiGe 1

Evaluation of the Radiation Tolerance of SiGe Heterojunction Bipolar Transistors Under 24GeV Proton Exposure

Leakage Current Prediction for GLAST Silicon Detectors

Status of ITC-irst activities in RD50

irst: process development, characterization and first irradiation studies

Studies of silicon strip sensors for the ATLAS ITK project. Miguel Arratia Cavendish Laboratory, University of Cambridge

Quality Assurance for the ATLAS Pixel Sensor

Monolithic Pixel Sensors in SOI technology R&D activities at LBNL

Monitoring of the Fabrication Process of Silicon Strip Sensors for Large Scale Productions

Measurement of charge collec1on in irradiated miniature sensors for the upgrade of ATLAS Phase-II Strip tracker

Testing Silicon Detectors in the Lab

The LHCb Silicon Tracker

1. Reasons for using p-type SSD

Development of Double-sided Silcon microstrip Detector. D.H. Kah*, H. Park, H.J. Kim (BAERI JikLee (SNU) E. Won (Korea U)

UNIVERSITY of CALIFORNIA SANTA CRUZ

Thin Silicon R&D for LC applications

Silicon Sensor and Detector Developments for the CMS Tracker Upgrade

Pixel sensors with different pitch layouts for ATLAS Phase-II upgrade

Evaluation of the Radiation Tolerance of Several Generations of SiGe Heterojunction Bipolar Transistors Under Radiation Exposure

Update of CMS Process Quality Control

Development of Pixel Detectors for the Inner Tracker Upgrade of the ATLAS Experiment

ATLAS Upgrade SSD Project:

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report

Simulation of new P-type strip detectors with trench to enhance the charge multiplication effect in the n- type electrodes

TCAD simulations of silicon strip and pixel sensor optimization

Measurements With Irradiated 3D Silicon Strip Detectors

Frequency Response Properties of the Silicon Vertex Detector for BaBar

Strip Detectors. Principal: Silicon strip detector. Ingrid--MariaGregor,SemiconductorsasParticleDetectors. metallization (Al) p +--strips

New fabrication and packaging technologies for CMOS pixel sensors: closing gap between hybrid and monolithic

CMS Beam Condition Monitoring Wim de Boer, Hannes Bol, Alexander Furgeri, Steffen Muller

Study of the radiation-hardness of VCSEL and PIN

arxiv: v3 [physics.ins-det] 9 Jan 2017

PoS(EPS-HEP 2009)150. Silicon Detectors for the slhc - an Overview of Recent RD50 Results. Giulio Pellegrini 1. On behalf of CERN RD50 collaboration

Radiation-hard/high-speed data transmission using optical links

AVALANCHE PHOTODIODES FOR THE CMS ELECTROMAGNETIC CALORIMETER

Description and Evaluation of Multi-Geometry Silicon Prototype Sensors for the LHCb Inner Tracker

Dual operational amplifier

The upgrade of the ATLAS silicon strip tracker

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Calorimeter system Detector concept description and first beam test results

Review of Silicon Inner Tracker

The CMS Silicon Strip Tracker and its Electronic Readout

The LHCb VELO Upgrade. Stefano de Capua on behalf of the LHCb VELO group

The BaBar Silicon Vertex Tracker (SVT) Claudio Campagnari University of California Santa Barbara

Geiger-mode APDs (2)

UV/EUV CONTINUOUS POSITION SENSOR

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Detector system

FACTOR: first results on SiPM characterization

OPTICAL LINK OF THE ATLAS PIXEL DETECTOR

Department of Physics & Astronomy

THE SILICON SENSOR FOR THE COMPACT MUON SOLENOID CONTROL OF THE FABRICATION PROCESS

Low Power Sensor Concepts

MICROELECTRONIC CIRCUIT DESIGN Third Edition

Study of irradiated 3D detectors. University of Glasgow, Scotland. University of Glasgow, Scotland

ATLAS strip detector upgrade for the HL-LHC

Sensor production readiness

Development of a large area silicon pad detector for the identification of cosmic ions

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

The HGTD: A SOI Power Diode for Timing Detection Applications

Unless otherwise specified, assume room temperature (T = 300 K).

Status of ATLAS & CMS Experiments

Sensor Concepts for Pixel Detectors in HEP

Experiment 9 Bipolar Junction Transistor Characteristics

Gamma-ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) Silicon Detector Specification

Lecture 2. Part 2 (Semiconductor detectors =sensors + electronics) Segmented detectors with pn-junction. Strip/pixel detectors

The CMS Pixel Detector Upgrade and R&D Developments for the High Luminosity LHC

Simulation of High Resistivity (CMOS) Pixels

Department of Electrical Engineering IIT Madras

Standard InGaAs Photodiodes IG17-Series

CMS Tracker Upgrades. R&D Plans, Present Status and Perspectives. Benedikt Vormwald Hamburg University on behalf of the CMS collaboration

Prototype Performance and Design of the ATLAS Pixel Sensor

Silicon Sensors for High-Luminosity Trackers - RD50 Collaboration status report

STUDY OF THE RADIATION HARDNESS OF VCSEL AND PIN ARRAYS

VELO: the LHCb Vertex Detector

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Tracking Detectors for the LHC Upgrade

First Results with the Prototype Detectors of the Si/W ECAL

IV curves of different pixel cells

Development of Monolithic CMOS Pixel Sensors for the ILC at LBNL

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD

Silicon Avalanche Photodiode SAR-/SARP-Series

Resolution studies on silicon strip sensors with fine pitch

HV BOARD. Claudio Arnaboldi Gianluigi Pessina INFN, Milano. Thierry Gys, Didier Piedigrossi CERN. LHCb, 15/12/2004 1

A GSM Band Low-Power LNA 1. LNA Schematic

Pin photodiode Quality Assurance Procedure

Results of FE65-P2 Pixel Readout Test Chip for High Luminosity LHC Upgrades

CMS Silicon Strip Tracker: Operation and Performance

Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC

First Sensor Evaluation Board Data Sheet Part Description MOD Order #

Preparing for the Future: Upgrades of the CMS Pixel Detector

Paper-1 (Circuit Analysis) UNIT-I

problem grade total

Silicon Sensors for HL LHC Tracking Detectors

Transcription:

Results on proton irradiation tests in Karlsruhe p do Bulk & Surface Damage Strip parameters after irrad. V FD for (300µm) and 500µm sensors after 10 years LHC Expectedpower for500 µm sensors after 10 years LHC Outlook F. Hartmann 1

Irradiation Facility 34 MeV protons 1000 na Beam spot: 2cm O T < -10 C Area: 20x40cm 2 Duration: 100cm 2 in 15min (1 sensor, 5e13p/cm 2 ) Compact Cyclotron at Forschungszentrum Karlsruhe 2

Cold Box Dry N 2 atmosphere at 10 C. Flexible box to hold sensors, teststructures and/or modules! Laser focus Simple power lines Temp. monitor 3

Simulate LHC bias conditions with respect to surface damage! During proton irrad.: Diode acts as a current source due to the p ionising effect SOLVE: 1V potential by applying V bias = 1V, But AC must also be on GND! DC diode Running @ LHC Rpoly CC AC readout (on GND) Current source Vbias Rpoly Here we need potentia like in LHC 1M Ω at 1µ A = 1V Strip current after irrad 4

Simulate LHC bias conditions with respect to surface damage! Bias ring --> GND Rpoly AC DC Short all AC to bias (GND) How to Realize? Backplane to +Vbias= 1V Conductive rubber V bias = 1V during irrad 5

Sensors before/after Irradiation 6

Fluences in the Tracker ~1.5e14 n/cm 2 for 320µm Upper limits: U FD <500V P(-10 C)<400mW ~0.5e14 n/cm 2 for 500µm 7

Irradiation Scheme 2 fluences chosen: Inner Tracker: 1.8e14 p/cm 2 (~3e14 n/cm 2 ): expected for low resisitivity silicon (300µm) * 1.8 18yLHC Outer Tracker: 0.5e14 p/cm 2 (~8e13 n/cm 2 ): expected for high resistivity silicon (500µm) *1.5 15yLHC Material (6, 500µm thick): 1 sensor W6b from Hamamatsu 1 sensor OB2 from ST Microelectronics 6 teststructures from Hamamatsu Biasing: 1V, 12V, 100V, non Notice: Inner Tracker fluence on Outer Tracker (500µm) sensors instead of 300µm, PRO: 1. resistivity almost right 2. No 320µm sensors present, 3. HPK will in future deliver inner 300µm sensors CON: unusual high V FD 8

Fluence Measurement 1.) Measurement by Ni-foil activation behind sensors: Calibration at 26 MeV Scaling with cross section to higher energies Fluence in [p/cm2] Hardness factor κ(e) scales to neutron equivalent 2.) I leak measurement: Temperature scaling to 20 C I(20 C)=I(T)*R(T); R(T)=(293K/T) 2 e (-E/k(1/293K-1/T)) ; E=1.4eV I/V=α*Φ α(t=20 C)=4e-17 A/cm Fluence in [n(1mev)/cm 2 ] 9

Karlsruhe probing equipment stencil/template Bias Measurements take ~1.5-2 hours Changing of sensor ~ 5 min Environment: 10 C, RH~1% 10

IV-Curve before/after Irrad. 2m 2m Sensor HPK Sensor ST Sensor HPK irradiated (1.8e14 p/cm 2 ) Sensor ST irradiated (0.5e14 p/cm 2 ) Current [A] 1m 500µ 10µ 8µ 6µ 4µ 2µ 0 0 200 400 600 800 1000 1200 Voltage [V] 11

Power Consumption 400.0µ 350.0µ I / V [A/cm 3 ] 300.0µ 250.0µ 200.0µ 150.0µ 100.0µ 50.0µ 0.0 Data (500µm sensors, ~5kΩcm) Linear Fit Extrapolated value for 500µm sensor at r=60cm α(t=-10 C) = 1.2 10-18 A/cm P ~ U FD I ~ d 2 d ~d 3 0.0 5.0x10 13 1.0x10 14 1.5x10 14 2.0x10 14 2.5x10 14 3.0x10 14 eq. Fluence [n/cm 2 ] 60µA/cm 3 => I leak (-10 C)=270µA (W6b) => P(500V, -10 C)=135mW/sensor Actual designed cooling power 400mW for each module (at least). 12

CV-Curve Curve before/after Irrad. 3,5x10 17 3,0x10 17 2,5x10 17 Capacitance -2 [F -2 ] 2,0x10 17 1,5x10 17 1,0x10 17 5,0x10 16 0,0 Sensor HPK Sensor ST Sensor HPK irradiated (1.8e14 p/cm 2 ) Sensor ST irradiated (0.5e14 p/cm 2 ) U FD ~ d 2 => U FD (320µm) = 410V 0 200 400 600 800 1000 1200 Voltage [V] ST and HPK sensors are stable up to V bias =1000V after irradiation! Even strip tests were done at V bias = 1000V! 13

Hamburg Model g a τ a (20 C) c g c 2.5x10 12 U FD (N eff )~d 2 g Y τ Y (20 C) 2.0x10 12 N [cm -3 ] 1.5x10 12 1.0x10 12 5.0x10 11 0.0 Beneficial Annealing Stable Damage Reverse Annealing PhD Thesis M. Moll: g a =(1.81±0.14)e-2 cm -1 τ a (20 C) =55h g c =(1.49±0.04)e-2 cm -1 c=(10.9±0.8)e-2 cm -1 /N eff g Y =(5.16±0.09)e-2 cm -1 τ Y (20 C)=475d Beneficial annealing Stable Damage Reverse Annealing 1 5 10 50 100 500 Time at RT [days] 14

Developement of U FD Full Depletion Voltage [V] 1100 1000 900 800 700 600 500 400 300 200 100 0 Data (FS sensors) Hamburg Model ST Hamamatsu 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 eq. Fluence [10 14 n(1mev)/cm 2 ] Data is fully compatible with the Hamburg model fit! Predictions for different annealing scenarios possible! 15

Full depletion as function of annealing time and fluence Fluence given at once, then annealing. 16

Annealing scenario: 14 days at RT each year 600 Full Depletion Voltage [V] 500 400 300 200 100 0 500µm, 4.4kΩ, 5e13n/cm 2 " Fluence at once 320µm, 2.2kΩ, 16e13n/cm 2 0 14 28 42 56 70 84 98 112 126 140 154 Annealing Time at RT [days] Iterative calculation of full depletion voltage 17

Depletion voltages for diode minisensor and full sensor 3,0x10 20 ~600V 2,5x10 20 Capacitance -2 [F -2 ] 2,0x10 20 1,5x10 20 1,0x10 20 5,0x10 19 Diode 2.6e14 n/cm 2 Full sensor 3e14 n/cm 2 Mini sensor 2.6e14 n/cm 2 ~600V 0,0 0 200 400 600 800 1000 ~1000V values shifted in y for comparison to compensate for different sizes Voltage [V] Future: diode measurements as reference! 18

Strip Leakage Current Leakage Current @ 400V [na] 1000 100 10 1 0.1 0.01 Minisensor 41 Before Irradiation After Irradiation and Annealing (Measurement at -10 C) 0 5 10 15 20 25 30 35 40 45 50 Strip number As expected: Increase in leakage current! 19

Bias Resistance Poly Resistance [MΩ] 2,3 2,2 2,1 2,0 1,9 1,8 0 5 10 15 20 25 30 35 40 45 50 55 60 Strip number Minisensor H41 Before Irradiation Raw Data: After Irradiation and Annealing (Measurement at -10 C) Corrected values due to high I leak Measurement: Apply U=2V Measure I Calculate R=U/I Correction: Measure I leak (high after irrad Correct R c =U/(U/R+I leak ) No change in bias resistances! 20

Coupling Capacitance Coupling Capacitance [pf] 120 115 110 105 100 95 90 85 80 75 70 65 60 0 5 10 15 20 25 30 35 40 45 50 Strip number Minisensor H39 Before Irradiation After Irradiation and Annealing (Measurement at -10 C) No change in coupling capacitances! 21

Interstrip capacitance of HPK full sensor (1 neighbour) Wedgeshaped sensor: Longer strips on the sides but less neighbours! structure 100 ff 20 ff <Cint>=3.2 pf 22

Interstrip Capacitance Interstrip Capacitance [pf] 0.90 0.75 0.60 0.45 0.30 0.15 Non irradiated: 1 MHz 100 khz Irradiated: 1 MHz 100 khz 0 200 400 600 800 1000 Bias Voltage [V] Interstrip Capacitance [F] (2 neighbours) 1,7p 1,7p 1,6p 1,6p 1,5p 1,5p Before Irradiation After Irradiation 1,4p 70 72 74 76 78 80 82 84 86 88 90 Strip No. No change in interstrip capacitance before/after irrad.@ 1MH Homogeneous interstrip distribution before/after irrad. 23

Future CMS dedicated teststand at the Cyclotron Scan area: 20 x 50 [cm] Scan speed: 1.25x 2.5 [cm/s] Maximum load: 20kg (New dedicated beamline line) 24

Future: irradiation of a full module TEC outer, TEC inner,tob,tib Longterm with high voltage, current, power Test of S/N, CCE, (pedestal,noise,shape) Test of components: sensor, electronics, mechanics. First IEKP TEC module 25

Conclusion 1. Both: ST and HPK comply with the specification of irradiation hardness 2. Data fits Hamburg model well and shows a decent behavior after 10 years of LHC operation 3. No changes in the strip parameters observed 4. Future dedicated teststand promise easy access to the cyclotron 5. Further plans: 300µm sensors and full modules will be irradiated! 26

NEW: Ingot pre-qualification (june 2001) Hamamatsu proposed to produce a couple of additional sensors out of each new ingot for irradiation pre-qualification Special procedure in addition to the standard task. All measurements on diode and minisensor Save large sensors as spares! INGOT: IV & CV on diode To determine Vdepletion, fluence estimation and α-factor PROCESS: Cint, Rint, leakage current, Rpoly vs. Vbias upto Vdepletion + 50V (for ~10 strips) 27