Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Similar documents
Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter

Rosemount 702 Discrete Input Transmitter

Rosemount 333 HART Tri-Loop

Rosemount 848T Eight Input Temperature Transmitter with FOUNDATION Fieldbus

Rosemount 248 Wireless Temperature Transmitter

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Rosemount 644 Temperature Transmitter

Rosemount 248 Wireless Temperature Transmitter

Rosemount 3101, 3102, and 3105

Rosemount 248 Temperature Transmitter

Rosemount 5400 Series Radar Level Transmitter

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Alphaline Temperature Transmitters

Rosemount 248 Temperature Transmitter

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Rosemount 644 Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter

Rosemount 708 Wireless Acoustic Transmitter

IP26 Series Current to Pneumatic Converter

The Rosemount 848T Wireless Temperature Transmitter

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

SmartPower Solutions. Product Data Sheet February , Rev AD

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Rosemount 248 Temperature Transmitter and Monitoring Assembly

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Rosemount 648 Wireless Temperature Transmitter

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Rosemount 702 Wireless Discrete Transmitter

Rosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol

Head mounted Temperature Transmitter TF02/TF02-Ex

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Mass and Volume Flow Transmitter

Rosemount 2088 Absolute and Gage Pressure Transmitter A TRADITION OF EXCELLENCE IN PERFORMANCE FROM THE INDUSTRY LEADERS

Model 580 Digital Process Indicators Series

Installation guide 971 SmartRadar LTi

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF DP Flowmeters

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

DeltaV SIS Logic Solver

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Process display RIA 261

Rosemount 753R Remote Web Based Monitoring Indicator

Specifications. Range 5. ±0.075% of span. URL % of Span ± ±0.04% of span. Ranges 2-4. ±0.04% of span

Installation guide 877 FDI Field Display & Interface

Resistance Thermometers Model Series TR7X0, Sheathed Design

Rosemount 248 Wireless Temperature Transmitter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Rosemount 705 Wireless Totalizing Transmitter

Best Practices for Power and Transient Protection on Rosemount Radar Transmitters

Rosemount 648 Wireless Temperature Transmitter

General Specifications

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Fisher 4200 Series Electronic Position Transmitters

Sarasota CM200 Sarasota HME900 Density Converter Electronics

SISNet Distance Extenders

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Micro Motion Model 2400S Transmitters with MVD Technology

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Fisher 646 Electro-Pneumatic Transducers

Isolators A3/1. Vibration Transducer Supply Unit Series

1420 Wireless Gateway

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

TIY Programmable, Isolated Thermocouple Transmitter combines

QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Micro Motion LF-Series Low Flow Flowmeter

Level Measurement Continuous level measurement Radar transmitters

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Electrical Temperature Measurement

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Micro Motion LF-Series Low Flow Sensor and Transmitter

Rosemount 644 Temperature Transmitter

Series 1000 and 2000 Transmitters with MVD TM Technology

Magnetostrictive Level Transmitter

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Level Measurement Continuous level measurement Radar transmitters

SALES SERVICE +358 (0)

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Positioner with HART Communication Type 3780

Rosemount 5408 and 5408:SIS Level Transmitters

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

R88000 T (including ATEX)

Emerson (Appleton Group ATX)

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

DeltaV SIS Hardware Carriers

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Mass Flow and Density Transmitter with FOUNDATION fieldbus

ATEX Installation Drawings and Instructions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Transcription:

Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily Configured with the Same DD Based Software Used for other FOUNDATION Fieldbus Devices Higher Availability Through Logic Execution Independent of a Central Controller Handles Demanding Applications with Fast Embedded Logic Execution Contents Specifications..................................................... page Fieldbus-3 Product Certifications............................................... page Fieldbus-5 Dimensional Drawings............................................... page Fieldbus-6 Ordering Information............................................... page Fieldbus-10 www.rosemount.com

Product Data Sheet Provides an Interface Between Discrete Inputs and Outputs and a Foundation Fieldbus H1 Segment. Logic Capability Includes Boolean AND, OR, XOR, and Timer Functions. Cost Effective H1 Discrete Input and Output: The 848L provides a cost effective field mounted interface for discrete inputs and outputs on a Foundation Fieldbus H1 network. The 848L allows you to leverage the fieldbus network to reduce discrete input and output wiring and eliminate the need for a separate discrete I/O bus. The 848L can communicate with other devices on the segment to provide logic interactions independent of any upper level controller. Compact Design Mounts Virtually Anywhere: The rugged design of the 848L allows it to be field mounted close to the process and equipment being monitored or controlled. The 848L is certified for use in Division 2 environments. Fieldbus Function Blocks: The device supports DI and MDI Digital Input Blocks, and DO and MDO Digital Output Blocks. Embedded Logic Capability: The 848L also has logic capability allowing it to independently control outputs based on the status of one or more of its inputs or discrete signals from other devices on the network. A Logic Block allows for up to 20 Boolean equations. 8 Inputs and 4 Outputs: The 848L can accommodate 8 inputs from either dry contact, 9-32VDC, or NAMUR sensors. The 4 9-32VDC outputs can handle loads of 1.0 amps up to a total of 4 amps for the device. Rosemount FOUNDATION Fieldbus Solutions Rosemount 3051S Pressure and Differential Pressure Transmitter Best-in-class performance with 0.04% accuracy available with FOUNDATION Fieldbus protocol. Rosemount 3144P Temperature Transmitter Two compartment housing, dual sensor design available with HART or Foundation Fieldbus protocol. Rosemount 644 Smart Temperature Transmitter Field mount styles available with HART or FOUNDATION Fieldbus protocol. Rail mount style available for HART protocol. Rosemount 848T Eight Input Temperature Transmitter Eight input transmitter available with FOUNDATION Fieldbus protocol. Rosemount 3420 Fieldbus Interface Module Provides an interface between FOUNDATION Fieldbus instruments and systems without fieldbus capability using standard interface protocols. Rosemount 752 Field Indicator Displays up to 8 variables from any device on the fieldbus segment. Rosemount 5600 Radar Gauge Provides a wide selection of antennas and materials for level measurement. Refer to www.fieldbus.org for additional Emerson Process Management FOUNDATION fieldbus products. The Transmitters power PlantWeb providing discrete I/O and logic processing on the fieldbus segment. Fieldbus-2

Specifications FUNCTIONAL SPECIFICATIONS Inputs 8 Discrete Inputs suitable for NAMUR specification sensors, 9-32VDC sourcing sensors or general switch inputs (dry contact) NAMUR Sensors: On state: > 2.1 ma Off state: < 1.2 ma 9-32 VDC Sourcing Sensors: On state: > 50% of I/O voltage Off state: < 20% of I/O voltage General Switch Inputs: On state: < 500 Ohms Off state: > 5k Ohms Minimum Pulse Width: 1ms Maximum Pulse Input Frequency: 500Hz Outputs 4 Discrete Outputs 9-32 VDC loads Maximum load inductance 7.0 H Current Ratings: 1.0 A maximum for single channel on, 4.0 A maximum per device. Output devices must be selected as follows: 1. Designed to use the same DC voltage as supplied to the 848L I/O power terminals. 2. The DC resistance must be large enough that they consume no more than 1 amp of current steady state. The internal impedance of the 848L is negligible, therefore the Output device s current is simply calculated as: I/O power / DC resistance. 3. The inductance of the output device must be less than 7.0H. The maximum total output current for the device will depend on the ambient temperature as shown in Figure 1. Total Output Current (Amps) FIGURE 1. Temperature vs. Output Current 4 3.5 3 2.5 2.0 1.5 1.0 0.5 0 Thermal Shutdown Protection prevents damage to the device if temperature specifications are exceeded. Isolation 45 Ambient Temperature (DegC) Input-Output 1200 VDC; 600 V rms 50/60 Hz for dry and 2-wire NAMUR contact inputs No isolation when using 3-wire sensors Input- Foundation Fieldbus 1200 VDC; 600 V rms 50/60 Hz 50 55 60 65 70 75 Output- Foundation Fieldbus 1200 VDC; 600 V rms 50/60 Hz Input power- Foundation Fieldbus 1200 VDC; 600 V rms 50/60 Hz Fieldbus-3

Input / Output Power Requirements 24 VDC nominal, 9 VDC minimum, 32 VDC maximum Supply Current Rating 0.5 amps at 24 VDC plus output load Fieldbus Segment Power Powered over the H1 Foundation fieldbus with standard fieldbus power supplies. The logic transmitter operates between 9.0 and 32.0 VDC at 22 milliamps. PHYSICAL SPECIFICATIONS Environmental Ratings Electronics (no enclosure) -40 C to +85 C 99% non-condensing humidity IP20 Unit (electronics and enclosure) -40 C to +85 C 100% condensing humidity IP66 Mounting The Rosemount 848T can be mounted directly onto a DIN rail or it can be ordered with an optional junction box. When using the optional junction box, the transmitter can be mounted onto a panel or to a 2-in. pipe stand (with option code B6). Entries for Optional Junction Box No entry Used for custom fittings Cable Gland 9 x M20 nickel-plated brass glands for 7.5 11.9 mm unarmored cable Conduit 5 plugged 0.86-in. diameter holes suitable for installing 1 /2-in. NPT fittings. Materials of Construction for Optional Junction Box Junction Box Type Paint Aluminum Epoxy Resin Plastic NA Stainless Steel NA Weight Assembly Weight oz lb kg Rosemount 848T only 9.60 0.60 0.27 Aluminum (1) 78.2 4.89 2.22 Plastic (1) 58.1 3.68 1.65 Stainless Steel (1) 77.0 4.81 2.18 (1) Add 35.2 oz (2.2 lb, 0.998 kg) for nickel-plated brass glands Environmental Ratings NEMA 4X, CSA Enclosure Type 4X, and IP66 with optional junction box. Product Data Sheet FUNCTION BLOCKS SPECIFICATION H1 Segment Device Back-up LAS Resource Block I/O Transducer Block All inputs can optionally be latched for the duration necessary for each input to be read during a macrocycle Logic Transducer Block (20 Boolean Equations) The processing cycle of the 848L logic equations from sampling the inputs to driving the outputs will vary depending upon the number and type of functions used in the 20 equations. Processing time can vary in the range of 50 to 150ms. Logic Functions AND, OR, XOR, NOT Rising Edge Trigger Falling Edge Trigger Turn On Delay Turn Off Delay Pulse Counter Reset Set Latch Shift Register Right Shift Register Left Function Blocks 8 DI blocks, 4 DO blocks, 1 MDI block, and 1 MDO block are provided. Foundation Fieldbus: Links 25 VCR 20 EXAMPLE FOR THE LOGIC EXECUTION: This diagram shows motor starter logic with start and stop buttons and an auxiliary contact which maintains current after the start button is pressed. Which would translate to a Boolean equation of: STOP = IN(1) START = IN(2) Relay M = IN(3) Closed when motor is running and not overloaded. AND(IN(1),OR(IN(2),IN(3))) which uses about 8% of the available time to maintain a 50ms execution frequency. Fieldbus-4

Product Certifications Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management Asia Pacific Private Limited Singapore Rosemount Temperature GmbH - Karlstein, Germany European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. HAZARDOUS LOCATIONS CERTIFICATES North American Approvals Factory Mutual (FM) Approvals N5 Nonincendive for Class I, Division 2, Groups A, B, C, D when installed per Rosemount drawing 00848-1035. Temperature code: T4 (T amb = 40 C to 60 C) Canadian Standards Association (CSA) Approvals N6 Suitable for Class I, Division 2, Groups A, B, C, D when installed per Rosemount drawing 00848-1036. Temperature code: T4 (T amb = 40 C to 60 C) IECEx Approvals N7 IECEx Type n Certification Certificate: IECEx BAS 05.0007X Ex nc IIC T4 (-40 C = T a = +50 C) Power Input Parameter: U i = 32.0 V Special Conditions for Safe Use: 1. The enclosure, cable gland, and blanking plug must be rated to a minimum of IP54. 2. The enclosure must be capable of withstanding a 7J impact. 3. Cable and conduit entries shall be constructed and mounted so that they do not degrade the specific characteristics of the protection of the apparatus. 4. The ambient temperature range of use shall be the most restrictive of the apparatus, enclosure, cable gland, or blanking plug. 5. The apparatus is not capable of withstanding the 500V insulation test required by Clause 8 of IEC 79-15: 1987. This must be taken into account when installing the apparatus. European Approvals N1 ATEX Type n Certification Number: Baseefa04ATEX0027X ATEX Marking II 3 G EEx nl IIC T4 (T amb = 40 C to 50 C) Power/Bus Input Parameter: U i = 32.0 V Special Conditions for Safe Use (x): 1. The ambient temperature range of use shall be the most restrictive of the apparatus, cable gland or blanking plug. 2. The apparatus is not capable of withstanding the 500V insulation test required by Clause 9.4 of EN 50021:1999 or Clause 8.1 of EN 60079:2003. This must be taken into account when installing the apparatus. 3. Component approved EEx e cable entries must be used so as to maintain the ingress protection of the enclosure to at least IP54. 4. Any unused cable entry holes must be filled with component approved EEx e blanking plugs. NC ATEX Type n Component Certification Number: Baseefa04ATEX0026U ATEX Marking II 3 G EEx na nl IIC T4 (T amb = -40 C to 50 C) Special Conditions for Safe Use (x): 1. The component must be installed in a suitable certified enclosure capable of withstanding an impact of 7.0J. 2. The apparatus is not capable of withstanding the 500V insulation test required by Clause 9.4 of EN 50021:1999 or Clause 8.1 of EN 60079:2003. This must be taken into account when installing the apparatus. ND ATEX Dust Ignition Proof Certification Number: Baseefa04ATEX0028X ATEX Marking II 1 D T90C (T amb = 20 C to 65 C) Special Conditions for Safe Use (x): 1. Component approved EEx e cable entries must be used so as to maintain the ingress protection of the enclosure to at least IP66. 2. Any unused cable entry hole must be filled with component approved EEx e blanking plugs. 3. The ambient temperature range of use shall be the most restrictive of the apparatus, cable gland or blanking plug. Fieldbus-5

Product Data Sheet Dimensional Drawings FIGURE 2. Dimensional Drawings Top View 6.7 (170) 3-D View Ground Screw Input Input Output Power Connector Front View Side View 1.7 (43) Dimensions are in inches (millimeters) 3.7 (93) FIGURE 3. Aluminum/Plastic Junction Box - Cable Gland (option codes JA2 and JP2) Top View 3-D View 10.24 (260) Ground Screw Front View Side View Dimensions are in inches (millimeters) 1.57 (40) 2.44 (62) 1.73 (44) 7.84 (199.2) 6.30 (160) 4.41 (112) 2.28 (58) 1.10 (28) 3.78 (96) Fieldbus-6

FIGURE 4. Stainless Steel Junction Box - Cable Glands (option code JS2) Top View 9.91 (231) 3-D View 7.7 (196) Ground Screw Dimensions are in inches (millimeters) Front View 1.8 (46) 1.1 (28) 1.73 (44) Side View 9.14 (232.2) 7.72 (196) 6.61 (168) 4.0 (102) 2.4 (62) 1.2 (30) 1.8 (47) FIGURE 5. Aluminum/Plastic Junction Box - Conduit Entry (option codes JA3 and JP3) Top View 10.2 (260) 3-D View Front View 157 (40) 2.44 (62) Side View 10.2 (260) Dimensions are in inches (millimeters) 3.5 (89) 1.7 (42) Five Plugged 0.86-in. diameter holes suitable for installing 1 /2-in. NPT fittings Fieldbus-7

Product Data Sheet FIGURE 6. Stainless Steel Junction Box - Conduit Entry (option code JS3) Top View 9.1 (231) 7.7 (196) 3-D View Ground Screw Dimensions are in inches (millimeters) Front View 1.4 (35) 1.1 (27) 2.8 (70) Side View 1.2 (30) 2.4 (62) 1.6 (42) 0.06 (1.5) 4.0 (102) 1.8 (4.7) Five Plugged 0.86-in. diameter holes suitable for installing 1 /2-in. NPT fittings Fieldbus-8

FIGURE 7. Wiring Diagram DISCRETE INPUT WIRING CONFIGURATION 2-Wire NAMUR Sensors 1 of 2 Input Connectors Dry Contact Switches 1 of 2 Input Connectors 3-Wire NAMUR Sensors 1 of 2 Input Connectors 9-32 VDC Sensors 1 of 2 Input Connectors DISCRETE OUTPUT WIRING CONFIGURATION 9-32 VDC Outputs Fieldbus-9

Product Data Sheet Ordering Information Model 848L Code F Code A Product Description (Includes One Fieldbus H1 Segment) Fieldbus Logic Transmitter Communications Protocol FOUNDATION fieldbus digital signal (includes 8 DI, 4 DO, 1 MDI, and 1 MDO function blocks, and Backup Link Active Scheduler) Power Input Bus and I/O Power (4-wire) Code Product Certifications Rosemount Junction Box required? NA No Approval No N1 ATEX Type n (enclosure required) Yes NC ATEX Type n Component No (1)(2) ND ATEX Dust Ignition Proof Yes N5 FM Non-Incendive for Class 1, Division 2, Groups A, B, C, D No N6 CSA Non-Incendive for Class 1, Division 2, Groups A, B, C, D No N7 IECEx Type n Approval (consult factory for availability) (enclosure required) Yes Code S001 S002 S003 S004 Code B6 JP1 JP2 JP3 JA1 JA2 JA3 JS1 JS2 JS3 CT Discrete Inputs and Outputs Types 8 - Dry Contact Inputs / 4-9 to 32 VDC Outputs 8-2-wire NAMUR Sensor Inputs / 4-9 to 32 VDC Outputs 8-3-wire NAMUR Sensor Inputs / 4-9 to 32 VDC Outputs 8-9 to 32 VDC Inputs / 4-9 to 32 VDC Outputs Options Mounting Kit Options Mounting Kit to a 2 in. pipe Non Explosion-Proof Junction Box Options Plastic Junction Box; No Entries Plastic Junction Box; Cable Glands (9 X M20 nickel-plated brass glands for 7.5-11.9 mm unarmored cable) Plastic Junction Box; Conduit Entries (5 Plugged Holes, suitable for installing 1 /2-in. NPT fittings) Aluminum Junction Box; No Entries Aluminum Cable Glands (9 X M20 nickel-plated brass glands for 7.5-11.9 mm unarmored cable) Aluminum Conduit Entries (5 Plugged Holes, suitable for installing 1 /2-in. NPT fittings) Stainless Steel Junction Box; No Entries SST Box; Cable Glands (9 X M20 nickel-plated brass glands for 7.5-11.9 mm unarmored cable) Stainless Steel Box, Conduit Entries (5 Plugged Holes, suitable for installing 1 /2-in. NPT fittings) Software Options Disable Local Logic Function Conduit Electrical Connector GE (3) M12, 4-pin, Male Connector (eurofast ) GM (2) A size Mini, 4-pin, Male Connector (minifast ) Typical Model Number: 848L F A NA S001 JP1 (1) The ordered with option code NC is not approved as a stand-alone unit. Additional system certification is required. (2) The must be installed so it is protected to at least the requirements of IP54; All listed Junction Boxes fulfill this requirement. (3) Available with Intrinsically Safe approvals only. For FM Intrinsically Safe or non-incendive approval (option code I5), install in accordance with Rosemount drawing 03151-1009 to maintain NEMA 4X rating. Fieldbus-10

Fieldbus-11

Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. FOUNDATION is a trademark of the Fieldbus Foundation. DeltaV is a mark of one of the Emerson Process Management companies. Eurofast and Minifast are registered trademarks of Turck Inc. All other marks are the property of their respective owners. Emerson Process Management Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA T (U.S.) 1-800-999-9307 T (International) (952) 906-8888 F (952) 949-7001 www.rosemount.com 00813-0100-4696«Emerson Process Management Heath Place Bognor Regis West Sussex PO22 9SH England Tel 44 (1243) 863 121 Fax 44 (1243) 867 554 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.emersonprocess.com 2008 Rosemount Inc.