TEST REPORT FROM RFI GLOBAL SERVICES LTD

Similar documents
TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Test. Report. Manufacturer. Model No. FCC ID. Technology. and. 1. This. 3. This. pp John Newell. as UL. Date of Issue: 28 May 2013.

TEST REPORT. Test Report No. : UL-RPT-RP JD03A V3.0. Date of Issue: 14 September pp John Newell Quality Manager, UL VS LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

TEST REPORT. Test Report No. : UL-RPT-RP JD02A V3.0. Date of Issue: 06 October 2017

TEST REPORT FROM RADIO FREQUENCY INVESTIGATION LTD.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

Report on the Intermodulation Testing. For. Technology Solutions (UK) Ltd Bluetooth Rugged UHF RFID Reader. Report no.

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Measurement of RF Interference from a Canopy 900MHz Access Point and Subscriber Module Using A Yagi Antenna

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. Bluetooth Remote Control for Video Set Top Box MODEL NUMBER: IPRC1000 FCC ID: 2ABTE-L3YJC9

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 CERTIFICATION TEST REPORT FOR

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

TEST REPORT FROM RFI GLOBAL SERVICES LTD

EMC Test Report. Tested by: Jeremy O. Pickens, Senior EMC Engineer. Reviewed by: David Schramm, EMC/RF/SAR/HAC Manager

Test. Report. : connectblue. Manufacturer. Model No. FCC ID 4.10, This. 3. This. as UL. Date of Issue: 22 May

7. FREQUENCY SEPARATION

TEST REPORT. Issued for: RUIMA INTERNATIONAL(HK)INDUSTRIAL CO.,LIMITED NO.19 Ruixiang Road, Xinhua Industrial Zone, Huadu District, Guangzhou China

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

TRANSMITTER MODEL: KAS-2030M

EMC TEST REPORT - Addendum

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. ION Audio, LLC. Portable Karaoke PA speaker with vocal effects

FCC Report for Parts ,

Test Report. Bluetooth Transceiver in UPCS Base Station. Panasonic Corporation of North America

FCC & IC Certification. Test Report. FCC & Industry Canada Certification. Test Report. for Hetronic USA FCC ID: LW9-CS434TXN IC ID: 2219A-CS434TXN

Spurious Emissions & Emission Mark Report

TEST REPORT. Test Report No. : UL-RPT-RP JD07H V2.0. Test Standard(s) : FCC Parts , , (a) &

FCC 47 CFR PART 15 SUBPART C CERTIFICATION TEST REPORT FOR. RF ID Reader MODEL NUMBER: A-405 FCC ID: WFQITCS-A-405 IC: 10717A-ITCSA405

Tested To The. and. Report. We strive to TESTING

Test Report. FCC Part 15, Subpart C, Section Industry Canada RSS-210, Issue 7

FCC RF Test Report. APPLICANT : TomTom International BV EQUIPMENT : GPS Navigation System BRAND NAME : TomTom MODEL NAME : 4CR51

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

F2 Labs Peters Road Middlefield, Ohio United States of America

1. GENERAL INFORMATION...

OUTDOOR SOUND MODULE/TRANSMITTER MODEL: THE BANDIT

FCC & IC TEST REPORT for Bluetooth Device No SHA-001

Measurement and Test Report

N : B Version : 01. Written by : Approved by :

Measurement of RF Emissions from a Caterpillar Inc. MSS3s RF ID Key Fob

Test Report. LEGO MINDSTROMS Brick with Bluetooth wireless Transceiver

ENGINEERING TEST REPORT

Chapter I - Federal Communications Commission Subchapter A - General Part 15 - Radio Frequency Devices Subpart C - Intentional Radiators

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-247 ISSUE 1 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR

TEST SUMMARY. Prüfbericht - Nr.: Test Report No FIELD STRENGTH OF FUNDAMENTAL RESULT: Passed % BANDWIDTH RESULT: Passed

FCC PART & IC RSS GHz FHSS TEST REPORT

Certification Test Report

SILENT PARTNER Model No.: SCOOP FCC ID: WXMSCOOP. In Accordance With

ENGINEERING TEST REPORT

TEST REPORT FCC ID: 2ADMF-HC06. : bluetooth module keyes HC-06, keyes hc-05, FUNDUINO HC-06, FUNDUINO hc-05

ROKU REMOTE MODEL: RC07

Test Report. Bluetooth Transceiver in UPCS Base Station

APPROVED BY: DATE: 19-Aug-2011 Brian Boyea, EMC Engineer. TESTED BY: DATE: 12-Aug-2011 Arturo Ruvalcaba, EMC Engineer

Report on the Radio Testing. For. Widex A/S. Widex Beyond Fusion2 (Model. B-F2) Report no. TRA B

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

Itron, Inc. TEST REPORT FOR. RF Telemetry Device Model: CCU100. Tested To The Following Standards:

FCC Part 22H & 24E Measurement and Test Report

FCC RF Test Report. SPORTON INTERNATIONAL INC. No. 52, Hwa Ya 1 st Rd., Hwa Ya Technology Park, Kwei-Shan Hsiang, Tao Yuan Hsien, Taiwan, R.O.C.

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

Electromagnetic Compatibility Test Report DIGITAL INDICATOR. MarCator 1086 R

Report On. Application for Grant of Equipment Authorization of the Hunter Douglas Window Fashions PV HUB Bluetooth Window Blind Remote Control

ITL Page 2 of 71 Report No.:

STC Test Report. Date : Page 1 of 13 No. : HM161169

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

TEST REPORT. Report Number: MIN-001 Rev 1.1 Project Number: G Testing performed on the 2102 IPG

F2 Labs Peters Road Middlefield, Ohio United States of America

1/41 IC: 109U-89FT7100

ENGINEERING TEST REPORT NUMBER: EUS1. ON Model No.(s): MB-PRO-MVK, MCU-430F5438A-MVK, AFE-BREAKOUT-MVK, RF-BREAKOUT-MVK, & RF-TCA8418-MVK

Prepared for : LG Electronics Inc. 19-1, Cheongho-ri, Jinwi-myeon, Pyeongtaek-si, Gyeonggi-do, Korea

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

HID GLOBAL CORPORATION

FCC CERTIFICATION TEST REPORT

FCC 47 CFR PART 15 SUBPART C ISED CANADA RSS-247 ISSUE 1 CERTIFICATION TEST REPORT FOR TETRA RADIO HANDSET HVIN: SC2024 PMN: SC2024

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

CERTIFICATION TEST REPORT

TEST REPORT. PolyComp 32X80P7.621YHB Electronic Sign. tested to the. 47 Code of Federal Regulations. Part 15 - Radio Frequency Devices

UL Japan, Inc. Head Office EMC Lab Asama-cho, Ise-shi, Mie-ken JAPAN Telephone : Facsimile :

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

FCC RF Test Report. STANDARD : FCC Part 15 Subpart C CLASSIFICATION : (DSS) Spread Spectrum Transmitter

DIRECTORY. 1. General Information Applicant Manufacturer Description of EUT Facilities and Accreditations...

2310 to 2390 MHz, 3m distance MCS8 (MIMO) to 2500 MHz Restricted band MCS8 (MIMO)

Full TEST REPORT. No. I16D00047-RFB. For. Client : Doro AB. Production : Clamshell phone. Model Name : DFC-0050 FCC ID: WS5DFC0050

COMMUNICATION CERTIFICATION LABORATORY 1940 West Alexander Street Salt Lake City, UT

FCC Test Report. : Wireless Way Richmond, BC, V6V 3A4 Canada : 47 CFR FCC Part 27 Subpart L

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System GTK-XB90 FCC ID: AK8GTKXB90

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Wireless Speaker SRS-XB10 FCC ID: AK8SRSXB10

TRFWL. Autostart Inc Rue Paré Mont-Royal, Québec Canada, H4P 2M2 EZSNAH2503

Page 2 of 20. Table of contents. Page

Operation in the MHz, MHz, and MHz

FCC REPORT. 570 E1 Camino Real #200, Redwood City, CA 94063, United Manufacturer:

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

FCC PART TEST REPORT. invoixa

RSS-247 TEST REPORT FOR CERTIFICATION On Behalf of. Sony Corporation. Home Audio System. Model No.: GTK-XB7 IC: 409B-GTKXB7

Transcription:

FROM RFI GLOBL SERVICES LTD Partial Test of: BTM4 To: FCC Part 5.247: 08 Subpart C, RSS- Issue 7 June 07 & RSS-Gen Issue 2 June 07 Test Report Serial No: RFI/RPT/RP78JD03 This Test Report Is Issued Under The uthority Of Brian Watson, Operations Director: Checked By: Tony Henriques Signature: Date of Issue: 03 November 09 The Bluetooth word mark and logos are owned by the Bluetooth SIG, Inc. and any use of such marks by RFI Global Services Ltd. is under license. Other trademarks and trade names are those of their respective owners. delete if not required This report is issued in dobe crobat portable document format (PDF). It is only a valid copy of the report if it is being viewed in PDF format with the following security options not allowed: Changing the document, Selecting text and graphics, dding or changing notes and form fields. This report may not be reproduced other than in full, except with the prior written approval of RFI Global Services Ltd. The results in this report apply only to the sample(s) tested.

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 This page has been left intentionally blank. Page 2 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Table of Contents. Customer Information...4 2. Summary of Testing...5 3. Equipment Under Test (EUT)...6 4. Operation and Monitoring of the EUT during Testing...8 5. Measurements, Examinations and Derived s...9 6. Measurement Uncertainty...27 ppendix. Test Equipment Used...28 RFI Global Services Ltd Page 3 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09. Customer Information Company Name: ddress: Ezurio Ltd Saturn House, Mercury Park Wycome Lane Woodburn Green Bucks HP0 0HH Page 4 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 2. Summary of Testing 2.. General Information Specification Reference: 47CFR5.247 Specification Title: Code of Federal Regulations Volume 47 (Telecommunications) 08: Part 5 Subpart C (Radio Devices) - Section 5.247 Specification Reference: RSS- Issue 7 June 07 Specification Title: Low-power Licence-exempt Radio communication Devices (ll Bands): Category I Equipment. Specification Reference: RSS-GEN Issue 2 June 07 Specification Title: General Requirements and Information for the Certification of Radio communication Equipment Site Registration: FCC: 9735; Industry Canada: 3245B-2 Location of Testing: RFI Global Services Ltd, Wade Road, Basingstoke, Hampshire, RG24 8H. Test Dates: 28 September 09 to 07 October 09 2.2. Summary of Test s FCC Reference (47CFR) Part 5.09 RSS-Gen 4.0/6 Part 5.247(b)(3) Part 5.247(d) & 5.9(a) Part 5.247(d) & 5.9(a) Key to s IC Reference Measurement Port Type RSS-Gen 4.8 RSS- 8.4(2) RSS-Gen 4.9 RSS- 8.5 RSS-Gen 4.9 RSS- 8.5 Receiver/Idle Mode Radiated Spurious Emissions Transmitter Maximum Peak Output Power Transmitter Radiated Emissions Transmitter Band Edge Radiated Emissions ntenna ntenna ntenna ntenna = Complied = Did not comply 2.3. Methods and Procedures Reference: NSI C63.4 (03) Title: Reference: D00-5 (00) Title: 2.4. Deviations from the Test Specification merican National Standard Methods of Measurement of Electromagnetic Emissions from Low Voltage Electrical and Electronic Equipment in the Range of 9 khz to GHz. Filing and Measurement Guidelines for Hopping Spread Spectrum Systems. Radiated testing only was performed as requested by the customer. RFI Global Services Ltd Page 5 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 3. Equipment Under Test (EUT) 3.. Identification of Equipment Under Test (EUT) Brand Name: Bluetooth Data Module Model Name or Number: BTM4 Serial Number: None stated Hardware Version Number: 02 Software Version Number: 6. FCC ID Number: PI44B Industry Canada Certification Number: 93B-BTM4 3.2. Description of EUT The equipment under test was a Bluetooth data module. 3.3. Modifications Incorporated in the EUT No modifications were applied to the EUT during testing. Page 6 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 3.4. dditional Information Related to Testing Tested Technology: Bluetooth Power Supply Requirement: Nominal 5.0 V Type of : Channel Spacing: Transceiver MHz Mode: Basic Rate Enhanced Data Rate Modulation: GFSK π/4-dqpsk 8DQPSK Packet Type: (Maximum Payload) DH5 2DH5 3DH5 Data Rate (Mbit/s): 2 3 Maximum Transmit EIRP: Transmit Range: Transmit Channels Tested: Receive Range: Receive Channels Tested: 3.5. Support Equipment 0.4 dbm 22 to 24 MHz Channel ID Channel Number Channel Bottom 0 22 Middle 39 244 Top 78 24 22 to 24 MHz Channel ID Channel Number Channel Bottom 0 22 Middle 39 244 Top 78 24 The following support equipment was used to exercise the EUT during testing: Description: Brand Name: Model Name or Number: Laptop Sony Vaio Serial Number: 2898206 RFI Global Services Ltd Page 7 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 4. Operation and Monitoring of the EUT during Testing 4.. Operating Modes The EUT was tested in the following operating mode(s): Transmit mode with Basic rate (DH5 packets) or EDR (2DH5 or 3DH5 packets) as required. Receive Mode: Standalone, with the Bluetooth mode active but not transmitting. 4.2. Configuration and Peripherals The EUT was tested in the following configuration(s): EUT was connected via a radio link to a Bluetooth tester in order to place the EUT into Bluetooth test mode. The laptop PC with the client s bespoke application was used to place the EUT into Bluetooth Test mode. For Transmitter Radiated Spurious Emissions, both EDR/Basic rate modes were compared and tests were performed with the mode that presented a worse case result. Page 8 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5. Measurements, Examinations and Derived s 5.. General Comments Measurement uncertainties are evaluated in accordance with current best practice. Our reported expanded uncertainties are based on standard uncertainties, which are multiplied by an appropriate coverage factor to provide a statistical confidence level of approximately 95%. Please refer to Section 6. Measurement Uncertainty for details. RFI Global Services Ltd Page 9 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5.2. Test s 5.2.. Receiver/Idle Mode Radiated Spurious Emissions Test Summary: FCC Part: 5.09 Test Method Used: Range: s detailed in NSI C63.4 Section 8 and relevant annexes MHz to 000 MHz Environmental Conditions: Temperature ( C): 25 Relative Humidity (%): 33 s: ntenna 36.523 Vertical 8.9.0 2. Complied 04.096 Vertical 2.0 43.5 22.5 Complied 22.87 35.8366333 MHz RBW 00 khz RF tt 0 db VBW 0 khz SWT 0 ms [T] 22.87 35.8366333 MHz 2 [T] 2. 03.86773547 MHz FCC VIEW IN M 2 P 0 0-0 - - Start MHz Date: 7.OCT.09 0:9:54 97 MHz/ Stop GHz Note: This plot is a pre-scan and for indication purposes only. For final measurements, see accompanying table. Page 0 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Receiver/Idle Mode Radiated Spurious Emissions (continued) Test Summary: FCC Part: 5.09 Test Method Used: Range: Environmental Conditions: Temperature ( C): 27 Relative Humidity (%): 25 s: ntenna Peak s detailed in NSI C63.4 Section 8 and relevant annexes GHz to 2.75 GHz verage 6997.996 Horizontal 48.0 54.0 6.0 Complied Note(s):. No spurious emissions were detected above the noise floor of the measuring receiver; therefore, the highest peak noise floor reading of the measuring receiver was recorded as shown in the table above. The peak level was compared to the average limit as opposed to being compared to the peak limit because this is the more onerous limit. 2. ll pre-scans were performed with a peak detector against the average limit apart from measurements made in the range of 8 to 2.75 GHz where pre-scans were performed with peak and average detectors and the applicable limit applied. This was due to the noise floor being very close to the average limit when using a peak detector. RFI Global Services Ltd Page of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Receiver/Idle Mode Radiated Spurious Emissions (continued) RBW MHz RF tt 0 db RBW MHz RF tt 0 db 47.0 48.03 77 3.8978357 GHz SWT 7.5 ms 77 6.99799599 GHz SWT 23 ms 77 77 D 54 D 54 IN IN VIEW M VIEW M 0 0 0 0-0 -0 - - -23-23 Start GHz 0 MHz/ Stop 4 GHz Start 4 GHz 0 MHz/ Stop 8 GHz Date: 2.OCT.09 00::25 Date:.OCT.09 23:43:05 RBW MHz RF tt 0 db RBW MHz RF tt 0 db 42.52 52.77 77 2.59769539 GHz SWT 27 ms 77 2.59769539 GHz SWT 27 ms 77 77 D 74 D 54 MX IN V MX IN M 0 0 0 0-0 -0 - - -23-23 Start 8 GHz 475 MHz/ Stop 2.75 GHz Start 8 GHz 475 MHz/ Stop 2.75 GHz Date:.OCT.09 23:47:52 verage Measurement Date:.OCT.09 23:53:5 Peak Measurement Page 2 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5.2.2. Transmitter Maximum Peak Output Power (EIRP) Test Summary: FCC Part: 5.247(b)(3) Test Method Used: s detailed in Public Notice D 00-5 (March, 00), NSI TI-3-C-04 and FCC CFR Part 2 Environmental Conditions: Temperature ( C): 27 Relative Humidity (%): 32 s: Basic Rate DH5 Channel EIRP (dbm) (dbm) Bottom -2.3.0 32.3 Complied Middle 0.4.0 29.6 Complied Top 0.3.0 29.7 Complied s: EDR 2DH5 Channel EIRP (dbm) (dbm) Bottom -2.8 2.0 23.8 Complied Middle -0.4 2.0 2.4 Complied Top -. 2.0 22. Complied s: EDR 3DH5 Note(s): Channel EIRP (dbm) (dbm) Bottom -2.5 2.0 23.5 Complied Middle -0.2 2.0 2.2 Complied Top -0. 2.0 2. Complied. These tests were performed radiated; therefore the EUT antenna gain is encompassed in the final result and not measurable. RFI Global Services Ltd Page 3 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5.2.3. Transmitter Radiated Emissions Test Summary: FCC Part: Test Method Used: Range 5.247(d) & 5.9(a) s detailed in NSI C63.4 Section 8 and Public Notice D 00-5 (March, 00) MHz to 000MHz Environmental Conditions: Temperature ( C): 27 Relative Humidity (%): 3 s: Top Channel - Emissions Occurring in the Restricted Bands ntenna.922 Vertical 37.9 43.5 5.6 Complied 275.783 Vertical 28.3 46.0 7.7 Complied 666.8 Horizontal 39.4 46.0 6.6 Complied 965.266 Vertical 33.8 54.0.2 Complied Note(s):. The preliminary scans showed similar emission levels below GHz, for each channel of operation. Therefore final radiated emissions measurements were performed with the EUT set to the top channel only. 2. Transmitter Radiated Spurious emissions were performed in Basic Rate, which was found as the worst case on investigation. FCC MX 29.59.64328657 MHz 2 RBW 00 khz RF tt 0 db VBW 0 khz SWT 0 ms [T] 29.59.64328657 MHz 2 [T] 28.63 274.92985972 MHz 3 [T] 37.52 667.59538 MHz 4 [T] 36.27 3 966.953782 MHz 4 IN M P 0 0-0 - - Start MHz Date: 29.SEP.09 00:34:34 97 MHz/ Stop GHz Note: This plot is a pre-scan and for indication purposes only. For final measurements, see accompanying tables. Page 4 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5.2.4. Transmitter Radiated Emissions Test Summary: FCC Part: Test Method Used: Range 5.247(d) & 5.9(a) s detailed in NSI C63.4 Section 8 and Public Notice D 00-5 (March, 00) GHz to 26.5 GHz Environmental Conditions: Temperature ( C): 26 Relative Humidity (%): 3 s: Highest Peak. Bottom Channel (GHz) ntenna ctual 44.045 Vertical 56.8 -.2 58.0 74.0 26.0 Complied s: Highest verage. Bottom Channel (GHz) ntenna ctual 43.983 Vertical 46.9 -.2 48.* 54.0 5.9 Complied s: Highest Peak. Middle Channel (GHz) ntenna ctual 488.76 Vertical 57. -.2 58.3 74.0 5.7 Complied s: Highest verage. Middle Channel (GHz) ntenna ctual 488.685 Vertical 46.5 -.2 47.7* 54.0 6.3 Complied s: Highest Peak. Top Channel (GHz) ntenna ctual 4959.763 Vertical 53.9 -.2 55. 74.0 8.9 Complied RFI Global Services Ltd Page 5 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Radiated Emissions (continued) s: Highest verage. Top Channel (GHz) ntenna ctual 49. Vertical 43.2 -.2 44.4* 54.0 9.6 Complied s: Highest Peak. Hopping Mode (GHz) ntenna ctual 488.76 Vertical 57. -.2 58.3 74.0 5.7 Complied s: Highest verage. Hopping Mode (GHz) ntenna ctual 43.983 Vertical 46.9 -.2 48.* 54.0 5.9 Complied Note(s): *verage values were calculated using the Duty cycle correction factor method as stated in D 00-5. This value was calculated to be -9.757 db. Page 6 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Radiated Emissions (continued) RBW MHz RF tt 0 db RBW MHz RF tt 0 db 87.55 48.22 2.47895792 GHz SWT 7.5 ms [T] 87.55 2.47895792 GHz 77 4.9692385 GHz SWT 23 ms 77 [T] 48.22 4.9692385 GHz D 54 IN D 54 IN MX M MX M 0 0 0 0-0 -0 - - -23 Start GHz 0 MHz/ Stop 4 GHz Start 4 GHz 0 MHz/ Stop 8 GHz Date: 28.SEP.09 2:59:59 Date: 28.SEP.09 22:5: RBW MHz RF tt 0 db 4.65 77 2.59769539 GHz SWT 27 ms 77 [T] 4.65 2.59769539 GHz RBW MHz RF tt 0 db 45.4 77 7.473947 GHz SWT ms 77 [T] 45.4 7.473947 GHz D 54 D 54 MX IN V MX IN V 0 0 0 0-0 -0 - -23 - -23 Start 8 GHz 475 MHz/ Stop 2.75 GHz Start 2.75 GHz 525 MHz/ Stop 8 GHz Date: 28.SEP.09 22:56: Date: 28.SEP.09 23:03:49 RBW MHz RF tt 0 db 42.22 77 25.8356734 GHz SWT 49 ms 77 [T] 42.22 25.8356734 GHz D 54 MX IN V 0 0-0 - -23 Start 8 GHz Date: 28.SEP.09 23:2:22 8 MHz/ Stop 26.5 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. RFI Global Services Ltd Page 7 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 5.2.5. Transmitter Band Edge Radiated Emissions Test Summary: FCC Part: Test Method Used: 5.247(d) & 5.9(a) s detailed in NSI C63.4 Section 8 and Public Notice D 00-5 (March, 00) Environmental Conditions: Temperature ( C): 26 Relative Humidity (%): 3 s: Peak Power Hopping Mode DH5: ntenna ctual 2.00 Vertical.3-0.2.5 *72.9 22.4 Complied 2.4835 Vertical 55.8-0.3 56. 74.0 7.9 Complied * - dbc limit s: verage Power Hopping Mode DH5 ntenna ctual (Db) 2.4835 Vertical 38. -0.3 38.4 54 5.6 Complied s: Peak Power Hopping Mode 2DH5: ntenna ctual 2.00 Vertical 46.7-0.2 46.9 *72.4 25.5 Complied 2.4835 Vertical 57.3-0.3 57.6 74.0 6.4 Complied * - dbc limit s: verage Power Hopping Mode 2DH5 ntenna ctual 2.4835 Vertical 37.4-0.3 37.7 54 6.3 Complied Page 8 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) s: Peak Power Hopping Mode 3DH5: ntenna ctual 2.00 Vertical 43.8-0.2 44.0 *72.7 28.7 Complied 2.4835 Vertical 58.3-0.3 58.6 74.0 5.4 Complied * - dbc limit s: verage Power Hopping Mode 3DH5 ntenna ctual 2.4835 Vertical 36.7-0.3 37.0 54.0 7.0 Complied RFI Global Services Ltd Page 9 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db.49 VBW 0 khz 56.07 3.7 2.000000 GHz SWT 5 ms 2 2.483000 GHz SWT 5 ms 3 0 3.7 db Offset * 2 2 db Offset * 00 00 D 92.89 VIEW IN M VIEW IN M D2 72.89 D 74 F F 3.7 Start 2.396 GHz 0 khz/ Stop 2.5 GHz 2 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 2:02:02 Date: 6.OCT.09 2:5:38 38.43 RBW MHz RF tt db DH5 2 2.483000 GHz SWT s 2 2 db Offset 00 VIEW IN V D 54 2 Start 2.476 GHz Date: 6.OCT.09 2:22:57 F.4 MHz/ Stop 2.49 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. Page of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db 46.87 VBW 0 khz 57.57 2.2 2.000000 GHz SWT 5 ms.3 2.483000 GHz SWT s 2 2.2 db Offset *.3 db Offset * 00 00 D 92.38 VIEW IN M VIEW IN M D2 72.38 D 74 F F 2.2 Start 2.396 GHz 0 khz/ Stop 2.5 GHz.3 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 22:3:7 Date: 6.OCT.09 22:0:44 37.73.3 2.483000 GHz.3 db Offset RBW MHz RF tt db SWT s 2DH5 00 VIEW IN V D 54.3 Start 2.476 GHz Date: 6.OCT.09 22:8: F.4 MHz/ Stop 2.49 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. RFI Global Services Ltd Page 2 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db 44.04 VBW 0 khz 58.58.5 2.000000 GHz SWT 5 ms 2 2.483000 GHz SWT 5 ms.5 db Offset * 2 2 db Offset * 00 00 D 92.67 VIEW IN M VIEW IN M D2 72.67 D 74 F F.5 Start 2.396 GHz 0 khz/ Stop 2.5 GHz 2 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 22:37: Date: 6.OCT.09 22:43: 36.98 RBW MHz RF tt db 3DH5 2 2.483000 GHz SWT s 2 2 db Offset 00 VIEW IN V D 54 2 Start 2.476 GHz Date: 6.OCT.09 22:5:25 F.4 MHz/ Stop 2.49 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. Page 22 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) s: Peak Power Static Mode DH5 ntenna ctual 2.00 Vertical 54.7-0.2 54.9 *73.0 8. Complied 2.4835 Vertical 57.0-0.3 57.3 74.0 6.7 Complied * - dbc limit s: verage Power Static Mode DH5 ntenna ctual 2.4835 Vertical 43.9-0.3 44.2 54.0 9.8 Complied s: Peak Power Static Mode 2DH5 ntenna ctual 2.00 Vertical 48.4-0.2 48.6 *72.4 23.8 Complied 2.4835 Vertical 58.6-0.3 58.9 74.0 5. Complied s: verage Power Static Mode 2DH5 ntenna ctual 2.4835 Vertical 42.4-0.3 42.7 54.0.3 Complied * - dbc limit s: Peak Power Static Mode 3DH5 ntenna ctual 2.00 Vertical 47.2-0.2 47.4 *72.7 25.3 Complied 2.4835 Vertical 58.9-0.3 59.2 74.0 4.8 Complied * - dbc limit s: verage Power Static Mode 3DH5 ntenna ctual 2.4835 Vertical 42.9-0.3 43.2 54.0 0.8 Complied RFI Global Services Ltd Page 23 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db 54.88 VBW 0 khz 57.25 2.3 2.000000 GHz SWT 5 ms.4 2.483000 GHz SWT 5 ms 2 2.3 db Offset *.4 db Offset * 00 00 D 92.97 VIEW IN M VIEW IN M D2 72.97 D 74 F F 2.3 Start 2.396 GHz 0 khz/ Stop 2.5 GHz.4 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 23::0 Date: 6.OCT.09 23:07:4 44.8 RBW MHz RF tt db DH5.4 2.483000 GHz SWT s.4 db Offset 00 VIEW IN V D 54.4 Start 2.476 GHz Date: 6.OCT.09 23:5:23 F.4 MHz/ Stop 2.49 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. Page 24 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db 48.55 VBW 0 khz 58.88.3 2.000000 GHz SWT 5 ms 0.6 2.483000 GHz SWT 5 ms.3 db Offset * 0 0.6 db Offset * 00 00 D 92.37 VIEW D2 72.37 IN M VIEW D 74 IN M F F.3 Start 2.396 GHz 0 khz/ Stop 2.5 GHz 0.6 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 23:3:48 Date: 6.OCT.09 23:35:07 42.7 RBW MHz RF tt db 2DH5 0.6 2.483000 GHz SWT s 0 0.6 db Offset 00 IN VIEW V D 54 0.6 Start 2.476 GHz Date: 6.OCT.09 23:37:3 F.4 MHz/ Stop 2.49 GHz Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. RFI Global Services Ltd Page 25 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 Transmitter Band Edge Radiated Emissions (continued) RBW 00 khz RF tt db RBW MHz RF tt db 47.36 VBW 0 khz 59.23 2.8 2.000000 GHz SWT 5 ms.4 2.483000 GHz SWT 5 ms 2 0 2.8 db Offset *.4 db Offset * 00 00 D 92.67 VIEW IN M VIEW IN M D2 72.67 D 74 F F 2.8.4 Start 2.396 GHz 0 khz/ Stop 2.5 GHz Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 6.OCT.09 23:4:28 Date: 7.OCT.09 00:02:00 43.6 RBW MHz RF tt db 3DH5.4 2.483000 GHz SWT s.4 db Offset 00 VIEW IN V D 54 F.4 Start 2.476 GHz.4 MHz/ Stop 2.49 GHz Date: 7.OCT.09 00:05: Note: These plots are pre-scans and for indication purposes only. For final measurements, see accompanying tables. Page 26 of 28 RFI Global Services Ltd

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 6. Measurement Uncertainty No measurement or test can ever be perfect and the imperfections give rise to error of measurement in the results. Consequently the result of a measurement is only an approximation to the value of the measurand (the specific quantity subject to measurement) and is only complete when accompanied by a statement of the uncertainty of the approximation. The expression of uncertainty of a measurement result allows realistic comparison of results with reference values and limits given in specifications and standards. The uncertainty of the result may need to be taken into account when interpreting the measurement results. The reported expanded uncertainties below are based on a standard uncertainty multiplied by an appropriate coverage factor such that a confidence level of approximately 95% is maintained. For the purposes of this document approximately is interpreted as meaning effectively or for most practical purposes. Measurement Type Range Confidence (%) Calculated Uncertainty Maximum Peak Output Power Not pplicable 95% ±2.94 db Radiated Spurious Emissions MHz to GHz 95% ±2.94 db The methods used to calculate the above uncertainties are in line with those recommended within the various measurement specifications. Where measurement specifications do not include guidelines for the evaluation of measurement uncertainty the published guidance of the appropriate accreditation body is followed. RFI Global Services Ltd Page 27 of 28

SERIL NO: RFI/RPT/RP78JD03 ISSUE DTE: 03 NOVEMBER 09 ppendix. Test Equipment Used RFI No. Instrument Manufacturer Type No. Serial No. Date Last Calibrated 534 Pre mplifier Hewlett Packard 8449B OPT H02 005 Calibrated before use 88 ntenna EMCO 35 00075692 25 Oct 08 2 288 ntenna Chase CBL6 589 3 Mar 09 2 436 ntenna Flann 2-3 24 pr 09 36 K0002 3m RSE Chamber Rainford EMC N/ N/ 0 Sep 09 2 M24 Spectrum nalyser Rohde & Schwarz ESIB26 00046K 09 Mar 09 2 M447 CBT Rohde & Schwarz 53.00.35 00329 9 Jan 09 2 NB In accordance with UKS requirements all the measurement equipment is on a calibration schedule. Cal. Interval (Months) - Page 28 of 28 RFI Global Services Ltd