Scanning Ion Conductance Microscope ICnano

Similar documents
Ionscope SICM. About Ionscope. Scanning Ion Conductance Microscopy. Ionscope A brand of Openiolabs Limited

Nanosurf easyscan 2 FlexAFM

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Redefining Gel and Blot Imaging

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

Nanoscale live-cell imaging using hopping probe ion conductance microscopy

3. are adherent cells (ie. cells in suspension are too far away from the coverslip)

Comparing FCS and FRAP as methodologies for calculating diffusion

Practical work no. 3: Confocal Live Cell Microscopy

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

LBM-7 Manual Manipulator

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

1 Co Localization and Working flow with the lsm700

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

Microscopic Structures

Differential ph Design Overcomes Common ph Sensor Challenges

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Nikon. King s College London. Imaging Centre. N-SIM guide NIKON IMAGING KING S COLLEGE LONDON

INTERFEROMETER VI-direct

High-speed 1-frame ms scanning confocal microscope with a microlens and Nipkow disks

Confocal Microscopy. Kristin Jensen

Micro-manipulated Cryogenic & Vacuum Probe Systems

ProScan DC Linear Servo Stage Technology

Bringing Answers to the Surface

Bi/BE 227 Winter Assignment #3. Adding the third dimension: 3D Confocal Imaging

Nanonics Systems are the Only SPMs that Allow for On-line Integration with Standard MicroRaman Geometries

LVEM 25. Low Voltage Electron Microscope Fast Compact Powerful.... your way to electron microscopy

Surface Finish Measurement Methods and Instrumentation

High-resolution, low light-dose lightsheet microscope LATTICE LIGHTSHEET

1. Editorial. N 9 June Content

Last updated: May 2014 Y.DeGraaf

Manufacturing Metrology Team

LBM-7 Manual Manipulator

nanovea.com PROFILOMETERS 3D Non Contact Metrology

LSM 780 Confocal Microscope Standard Operation Protocol

Systematic Workflow via Intuitive GUI. Easy operation accomplishes your goals faster than ever.

FemtoFAB. Femtosecond laser micromachining system. tel fax Konstitucijos ave. 23C LT Vilnius, Lithuania

write-nanocircuits Direct-write Jaebum Joo and Joseph M. Jacobson Molecular Machines, Media Lab Massachusetts Institute of Technology, Cambridge, MA

Multifluorescence The Crosstalk Problem and Its Solution

Low Voltage Electron Microscope

Precision-tracking of individual particles By Fluorescence Photo activation Localization Microscopy(FPALM) Presented by Aung K.

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

GEL IMAGING AT A TOUCH

Principles of operation 5

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Working Simultaneously. The Next Level of TIRF Microscopy. cell^tirf Illuminator Motorized Total Internal Reflection Fluorescence

M-041 M-044 Tip/Tilt Stage

Nanovie. Scanning Tunnelling Microscope

NSOM (SNOM) Overview

P-736 PInano Z Microscope Scanner for Microtiter Plates

High Precision Positioning Mechanisms for a Hard X-ray Nanoprobe Instrument. Abstract

Shreyash Tandon M.S. III Year

Live Cell Screening System

Micromanipulator System NT-88-V3 Series

PICO MASTER 200. UV direct laser writer for maskless lithography

Material analysis by infrared mapping: A case study using a multilayer

Leica SP8 Resonant Confocal. Quick-Start Guide

Confocal Laser Scanning Microscopy

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

Multiphoton Detection Unit (MDU)

Ion Beam Lithography next generation nanofabrication

LOW TEMPERATURE STM/AFM

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

Comparison of resolution specifications for micro- and nanometer measurement techniques

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

Leica SP8 TCS Users Manual

MFP-3D-BIO. Asylum Research. The only full-capability AFM on an inverted optical microscope

Low Voltage Electron Microscope

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

Cell-chip coupling for bioelectronic devices. Lab manual

Fast Laser Raman Microscope RAMAN

Near-field Optical Microscopy

PH880 Topics in Physics

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

easypll UHV Preamplifier Reference Manual

Sensors and Metrology - 2 Optical Microscopy and Overlay Measurements

Fast Laser Raman Microscope RAMAN

Gel imaging at a touch S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

Improving the Collection Efficiency of Raman Scattering

1 Set up the confocal light path for imaging a green dye (Alexa488-EGFP). For example, the

Compact Nanopositioning System Family with Long Travel Ranges

PhE102-VASE. PHE102 Variable Angle Spectroscopic Ellipsometer. Angstrom Advanced Inc. Angstrom Advanced. Angstrom Advanced

High Resolution BSI Scientific CMOS

Confocal Microscopy and Related Techniques

LSM 800 Confocal Microscope Standard Operation Protocol

Electronic Design of a Semi-Automated Micromanipulator Cell Injection System

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Experimental protocol PIPE

Effects of spherical aberrations on micro welding of glass using ultra short laser pulses

FLUORESCENCE MICROSCOPY. Matyas Molnar and Dirk Pacholsky

Transcription:

Sperm Cell Epithelial Cells I nner Ear Hair Cells I nner Ear Hair Cell Neurons E- Coli Bac teria Scanning Ion Conductance Microscope ICnano

About ionscope About ionscope The ionscope scanning ion conductance microscope delivers high-resolution topographic imaging and a wide range of additional functionality for life, physical and material sciences. Developed by a team of scientists at Imperial College London and Cambridge University, ionscope s proprietary technology modulated probe ion conductance scanning offers uncompromised performance and stability, thus enabling high resolution continuous scanning over long periods. Innovative Design Incorporating a host of proprietary design features, the ionscope ICnano has established itself as the next generation research tool for a broad range of cutting edge applications. Glass nanopipettes are pulled to the required dimension using a standard pipette puller making setting up simple and inexpensive. SICM differentiates itself from other nanoscale modalities through its ability to produce these images by sensing ion current and not through attraction or repulsion, and thus involves no mechanical interaction with the surface during scanning. The ICnano offers a unique, state of the art, closed loop flexure scan system that ensures accurate measurements with low noise levels. Three independent piezos in x, y and z allow accurate measurements in all three dimensions regardless of size, offset, speed, and rotation. The system offers high resolution imaging with great ease and scans up to 100µm in x and y with an exceptional 100µm range in z. Integration with high resolution optics makes finding features and the pipette tip fast and easy. Versatile Acquisition Software The ionscope software integrates a host of features with intuitive, straightforward access to all scanning and feedback parameters. Fully automated tip approach combined with real-time scan progress monitoring and automated scan parameter selection makes set up fast and easy. The ionscope image analysis and presentation software provides a comprehensive set of image manipulation tools and multichannel rendering designed to aid analysis, exploration and presentation of data. Straightforward Operation The ICnano, with its capacity for high resolution imaging, can be operated as a standalone instrument, presenting a compact and cost effective imaging and probe automation capability. Sample preparation is effortless simply place the sample in a petri dish and immerse in electrolyte solution. The ICnano provides excellent sample access, easy placement of electrodes and straightforward mounting of the nanopipette. The core algorithm driving the system seeks to avoid any physical surface interaction, whether of the sample or of floating debris, helping to protect the scan, the sample and the system from damage and contamination. Once set up, the system can continue to scan unattended for long periods enabling dynamic processes such as live cell interactions to be followed over days.

Unrivalled Integration and Flexibility Integration of the ICnano with a number of advanced optical techniques such as scanning confocal microscopy, FRET, and TIRF provide a powerful approach for correlating spatial information with dynamic cellular processes. When combined with scanning confocal microscopy, the pipette tip and laser focus may be locked together. The optical focus tracks the pipette tip, following the sample contours and presents a fluorescent emission map in a single pass eliminating degradation by photo-bleaching. Replacing micro-manipulators with the ICnano offers radical improvement to patch clamp productivity and effectiveness. Using the patching pipette itself as the scanning probe, a cluster of cells may be imaged and a target cell selected. A single cell may be scanned at higher resolution to identify specific locations of interest. The fine tip aperture can be precisely positioned vertically at the target using computer control. Through this process, the tip is protected from inadvertent contact with the cell surface or with floating debris by the ICnano s feedback control system. Exploiting the hybrid functionality of the nanopipette provides additional powerful research flexibility through delivery of defined chemical, electrical and mechanical stimuli. Combining scanning ion conductance microscopy with a hydraulic pressure system allows quantitative pressure to be applied at precise locations to probe surface mechanical properties using the same pipette as is used for scanning. The nanopipette can also be filled with specific reagents or biomolecules and used for controlled, local, voltage-driven application for deposition or response mapping. Drawing out multi-barrelled pipettes offers further extension of these applications. Configuration Options Sample scan ICnano S Pipette scan ICnano P In the ICnano S scan head the probe is held in a fixed position and the sample is moved. As the sample is scanned in X and Y, the control system adjusts the Z position to maintain a fixed distance from the probe tip. If used with an inverted optical microscope, the ICnano S scan head is simply placed onto the existing stage. In addition to providing easy mounting and removal, this configuration enables the recording of fluorescence at the same time as surface topography the sample surface is always within the confocal volume. In the ICnano P scan head the sample is held in a fixed position and the pipette is scanned across its surface. The sample is placed onto the optical microscope stage, allowing the use of an existing holder, perfusion chamber or incubator. This configuration is also appropriate if additional probes or microelectrodes are required to engage the sample. The ICnano P scan head is bolted onto the fixed frame of the optical microscope and comes with an adaptor plate appropriate to each specific model.

Scanning Near-field Optical Microscopy & SICM Scanning Surface Confocal Microscope Nanowriting Scanning Electrochemical Microscopy & SICM ICnano Scanning Ion Conductance Microscope (SICM) Non-contact Mechanical Stimulation Functional imaging SICM Smart Patch Clamp Multifunctional Nanoprobe Microscopy Scanning Ion Conductance Microscopy : Hybrid Techniques Images top left to bottom right : S-Layer protein from Bacillus sphaericus 40nm; Cardiac Myocyte 8µm; Neurons 65µm; Sperm cell 14x8µm; Two colour printing using DNA 60µm; Greyscale printing using DNA 60µm; Hearing Cell 7µm; Kidney endothelial cells 40µm.

Scanning Ion Conductance Microscopy How Does I t Work? Scanning Ion Conductance Microscopy is used to acquire topographic images of surfaces immersed in electrolyte liquid, often a physiological buffer. The scanning probe is a glass or quartz nanopipette filled with electrolyte, which measures the ion current passing through its tip. That current is limited by the tip aperture; the potential difference that drives it is applied between reversible silver- silver chloride electrodes, one inside the pipette and one in the sample dish. The current decreases as the probe tip approaches the surface. The sample, under the pipette, is raster scanned while the probe-sample distance is maintained by monitoring the ion current, and its feedback control. This means the pipette tip never makes unintended contact with the sample. Simple to use No sample preparation required, just immerse the sample in a dish containing electrolyte solution Nanopipettes are easily prepared using a standard pipette puller. Electrodes are inserted into the pipette and the sample dish Automated tip approach for rapid and easy scan start Superior Performance Using our proprietary distance modulated imaging mode, ionscope offers the highest resolution imaging on living cells Fast, sensitive feedback allows prolonged imaging and follows dynamic processes over long periods, for example 24 hours Easily integrates with optical techniques such as confocal fluorescence, allowing direct functional correlation of data Dynamic Scanning 100µm scan range in x,y and z is advantageous for imaging biological materials Accurate image offset and zoom capabilities are achieved without changing hardware Uses ultra low noise independent closed loop x, y and z piezo flexure stages for accurate planar imaging with low cross talk S canning Ion Conduc tance M icroscopy : How Does I t Work? Powerful and Flexible Research Tool The nanopipette can be used as a smart patch clamp for electrophysiology measurements on defined cell regions selected from the scanned image Precise deposition of molecules to target sites on the sample can be achieved through voltage control of the nanopipette Mechanical stimulation and force measurements can be achieved through positive and negative hydraulic pressure in the pipette

System Scan resolution Scan time Image resolution Image formats 20nm XY; 5nm Z 50s 20min (typical, 5µm x 5µm and 90µm x 90µm respectively) 64x64 1024x1024 pixels IMG (16-bit greyscale) XY scan Range 100µm x 100µm Resolution 20nm overall (1nm for stage) Linearity 1% Max pixel step rate 1ms per pixel Z scan Range 100µm Resolution 5nm overall (1nm for stage) Pipette Tip diameter Typical surface proximity Body diameter Positioning Range Resolution Electrodes Pipette Bulk electrolyte 100nm borosilicate; 10nm quartz 25nm for 50nm ; 100nm for 200nm 1mm 15mm XY; 25mm Z 100nm silver/silver chloride wire silver/silver chloride pellet Scan head assembly Translation stage Physik Instrumente PI Hera P-6xx, 100µm; PI LISA P-753, 25µm Motorised positioning Physik Instrumente M-111/112 DC motor translation stages Overall dimensions Approx. 13cm (W) x 17cm (D) x 15cm (H) clamping, it may be connected instead. Feedback resistor 1GΩ Input bias current 1pA max at 25 C Power supply ±12V tel fax email website ionscope limited A2 Ash House M elbourn Science Park Cambridge Road M elbourn, SG8 6HB, UK +44 (0)17 6326 9070 +44 (0)20 7681 3447 info@ ionscope. com www. ionscope. com