ZCS485 User s Manual. Version ZYPEX, Inc.

Similar documents
CP485-4 User s Manual

Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485

Miniature Synchronous Multipoint Modems

CONV232/422 SERIAL DATA CONVERTER

Integrity Instruments

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

Applications. Operating Modes. Description. Part Number Description Package. Many to one. One to one Broadcast One to many

Serial Communications RS232, RS485, RS422

PRODUCT INFORMATION B&B ELECTRONICS. Port-Powered RS-232 Fiber Optic Modem with Handshake Support. Model 9PFLST. Description. RS-232 Connections

Universal RS232/CMOS to RS422/RS485 Converter

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

The I-2532 CAN to Fiber Converter

Concept of Serial Communication

DSP4xxFP SA USER S MANUAL. A01561 Rev. A. This Manual covers all configurations of the DSP4xxSA Modem with the Serial Number SA and up.

TD_485 Transceiver Modules Application Guide 2017

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

There are many important factors when trying to achieve good, reliable communications between 2 devices.

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Model 4xx. Plug-in Series Of FSK Modems USER GUIDE. (TI) 20 Jan 06 DWG: A GDI COMMUNICATIONS LLC PO Box I-80 Exit 1 Verdi, NV 89439

Fanuc Serial (RS232) Communications Information

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

Lecture #3 RS232 & 485 protocols

APPLICATION BULLETIN. SERIAL BACKGROUNDER (Serial 101) AB23-1. ICS ICS ELECTRONICS division of Systems West Inc. INTRODUCTION CHAPTER 2 - DATA FORMAT

MGE TM Galaxy TM , 60 Hz kva

2070-6A Manual A Manual. Dual 1200 baud Modem For The 2070 Controller GDI A MANUAL

USER'S MANUAL. Model : K

1.0 Introduction. Related Products and Documentation

2070-6B Manual B Manual. Dual 9600 baud Modem For The 2070 Controller. GDI B Manual. Rev B

MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE

TRXQ1 RXQ1 FM NARROW BAND TRANSCEIVERS. RXQ1 Version. Applications. TRXQ1 Version

USING RS-232 to RS-485 CONVERTERS (With RS-232, RS-422 and RS-485 devices)

Contents. Warranty and Disclaimer 2 Introduction 3

SMARTALPHA RF TRANSCEIVER

Mini PROFIBUS Repeater PFB-R User's Manual FOURSTAR Electronic Technology Co., Ltd. Deyang China All Right Reserved

RS-422/485 Application Note

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

9600 bps, Dual Modem 170 Card Private Wire Only

Contents. Warranty and Disclaimer 2 Introduction 3

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

G1SLE Mk2 Repeater Controller Programming.

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Interface: Serial EIA RS-232D/CCITT V.24, DCE; RTS/CTS delay 0,8 or 64 ms (user-selectable).

This FAQ covers Single Direction use of current loop with transmitting devices.

M-Bus Master MultiPort 250L Installation and User Guide

RS-232 / 20mA Interface Converter ELO E00Q. Operation manual

Serial Input/Output. Lecturer: Sri Parameswaran Notes by: Annie Guo

Cross-Connect Interface

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

This FAQ covers the common questions from technicians installing these converters.

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

RS-232 to Current Loop Converters

MODEL 800. GDI Communications, LLC. Dual 1200 BAUD Modem. Verdi, Nevada. rzidnanga-arnnt= Pnnc1 rsf 17

TD_CAN Transceiver Modules Application Guide 2017

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

2W UHF MHz Radio Transceiver

TDM-1 TRANSPARENT OR ADDRESSABLE RADIO DATA MODEM INSTRUCTION MANUAL

MDW-45 Converter RS RS-422/485

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MA-12 AC MA-12 DC. Korthållsmodem Short haul modem Kurzstreckenmodem

Modem RS232/RS422/RS485. to MM optic fibers. RS-232 to Multimode Optic. Fiber Converter. Characteristics DIN rail mounting.

Ocean Controls KT-5221 Modbus IO Module

FOM-5A, 6A Asynchronous Fiber Optic Modems

Analog Module D1-15P User Manual

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Data Acquisition Modules/ Distributed IO Modules

Model RTX-12 Radio Modem

Contents. Warranty and Disclaimer 2

Installation Guide Metretek RS-485 Adaptor Board

RS-422/RS-485 Line Tester Model 485T

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION MD-45 AC MD-45 LV/HV

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

Chapter 12: Digital Modulation and Modems

Appendix C RS-485 Network

4 Channel 4~20mA / 0~10VDC Analog DIN Fiber Link System

Harris IRT Enterprises, Inc. Digital Resistance Tester Model A

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

DigiPoints Volume 1. Student Workbook. Module 2 Modem Overview

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

Dual Protocol Transceivers Ease the Design of Industrial Interfaces

Model FLSC-C1-LIQ. Microprocessor Based Loop Powered Transmitter

Electronics / Water analogy. Resistor. Inductance. Capacitor. Water Electronics Energy - Energy Pressure - Voltage Flow - Current Volume - Charge

1 What s in the shipping package?

NCS-C150 INSTRUCTION MANUAL Rev A. Collcomm Inc. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

ANALOG AND DIGITAL PHYSICAL INTERFACES

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

285E Series DIGITAL FIBER OPTIC AUDIO/DATA TRANSPORT SYSTEM

INSTALLATIONSANVISNING MD-21 AC INSTALLATION MANUAL REV. A MD-21DC INSTALLATIONS ANLEITUNG

Interface converter G kbit/sec

RS-232 Electrical Specifications and a Typical Connection

Non-Powered Interface Converters RS-232 to RS-530 RS-422 to V.35 RS-232 to RS-485 RS-232 to RS-422/RS-449

NCS-C150 INSTRUCTION MANUAL Rev D. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

Meter Bus Application ANALOG-BOARD Revision 5.1

96M0374. Instruction Manual. Analog Sensor Controller. RD Series

Brushless DC Motor Controller Specification Assemblies 025F0248

ICS REPEATER CONTROLLERS

NCS-C151 INSTRUCTION MANUAL Rev B. Collcomm Inc. d.b.a. NCS. Shipping Address 2310 Pendley Road Cumming, Georgia 30041

Absolute encoder HE-65

UNICOM 2500 UNICOM Installation Operation Programming. Universal Communication Converter

Instruction Manual MTX-8485C MRX-8485C Four Channel Video Multiplexer with Bi-directional Data

Transcription:

ZCS485 User s Manual Version 2.2 2004 ZYPEX, Inc.

Table of Contents Product Description 1 ZCS485 Configuration & Setup 2 4-wire Operation 2 2-wire Operation 2 Dual Port Operation 2 Carrier Detect 2 Transmitter Control 3 Baud Rate Selection 3 Keydown Delay 3 CTS Delay 3 J10 Jumper Settings 4 Baud Rate Selection 4 Keydown Selection 4 Data/DCD Jumper 4 Data RTS Jumper 4 J13 Jumper Settings 4 CTS Delay 4 RS-485 RX and TX Jumpers 5 Line Termination 5 Transient Protection and Grounding 6 Transient Protection 6 Shield Connection 6 Static Control 6 Connectors 8 Power 8 RS-232 8 RS-485 8 RJ11 8 Product Specification 9 Trouble Shooting 10 Contact Information 11 Appendix A 12 Half-Duplex Jumper Configuration 13 Full-Duplex Jumper Configuration 14

Product Description The ZCS485 line driver is an RS-232 to RS-485 interface converter. It allows an RS-232 device to reliably transmit data over long distances (up to 4000 feet). The ZCS485 has many features not normally found in typical line drivers, and is intended for operation in harsh industrial environments. The ZCS485 may be used in point-to-point applications as well as multi-drop applications using either 4-wire or 2-wire configurations. Up to 32 devices may be connected together on one communication line. The ZCS485 can also be used as a dual-port half-duplex splitter. As a master, the ZCS485 can talk to two trunks of up to 31 half-duplex devices. This allows the ZCS485 to talk to up to 62 devices. A variety of timing and control options are available on the ZCS485. An RTS to CTS delay provides the ability to turn on the RS-485 transmitter before sending data to allow the communication line to stabilize. RS-485 transmitter control may be implemented using the RS-232 RTS signal or the presence of RS-232 TX data. A unique capability of the ZCS485 is the ability to sense the presence of a received RS-485 carrier (remote RS-485 driver enabled). This is very useful for controlling devices that require a turn-on delay before data can be transmitted like radio modems. The carrier detect signal can also be based on the presence of received RS-485 data. All timing functions are crystal controlled and provide very accurate and stable delays. Temperature and voltage fluctuations will not affect the ZCS485 s operation. The ZCS485 has 1500 volt optical isolation between the RS-232 side and the RS-485 side. The RS-485 lines are protected with 2 stages of surge protection, and jumpers allow complete configuration of terminating and pull up/down functions. 1

ZCS485 Configuration and Setup 4-wire Operation (J8 OUT) 4-wire operation provides full-duplex capability for point-to-point configurations. A 4-wire half-duplex configuration is also useful where the master unit is always transmitting to the slave units, and the slave units respond to the master in halfduplex style. This simplifies the control software for the master, and can provide a speed advantage over 2-wire half-duplex configurations. The slave units can enable their transmitters using either RTS control or data control. 2-wire Dual Port Operation (J8 IN) Multi-drop applications typically use a 2-wire configuration. Installation requires a single twisted pair, and all nodes can talk to each other. Many applications use a single master with multiple slaves. The ZCS485 is capable of dual port 2-wire operation. If J8 is installed, the RX and TX pairs both operate as half-duplex ports. A ZCS485 configured for dualport operation can communicate with 2 trunks of half duplex slaves. This allows the ZCS485 to talk to 2 trunks of 31 slaves or 62 slaves total. Carrier Detect A feature available on the ZCS485 that is not available on most line drivers is the ability to detect when a remote line driver has turned on its transmitter. This is useful for controlling other equipment that may require carrier control like radio modems. This signal is passed to the RS-232 port as the Data Carrier Detect (DCD) signal. Carrier detect works by sensing a voltage level greater than 850mV between the RX+ and RX- wires. Built-in hysteresis prevents the DCD signal from oscillating in noisy environments. The pull-up, pull-down and termination jumpers (J4, J3 and J2) must be installed on each end of the communication line for proper operation. The DCD output will maintain its last state when the RTS signal is asserted and the ZCS485 is used to transmit data. Carrier detect can also be asserted based on the presence of received data. If the DCD jumper on J10 is installed, the RS-232 DCD signal is asserted when incoming RS-485 data is received. The DCD signal is asserted as soon as RS- 485 data is detected. Following the last character, the DCD signal is held active for the delay time set by the Keydown Delay jumpers before being de-asserted. The baud rate jumpers on J10 must be set to the desired baud rate. 2

Transmitter Control The ZCS485 s RS-485 transmitter may be controlled by either the RS-232 RTS control signal or the presence of data on the RS-232 TX data pin. If the RTS signal is used to control the transmit function, any data format or baud rate may be used. If TX data is used to control the transmit function, the desired baud rate must be set using the jumpers on J10 and a data format of 1 start bit, 8 data bits and 1 stop bit is assumed. The length of time that the RS-485 transmitter remains enabled following the end of the last character is determined by the Keydown Delay jumpers. Baud Rate Selection Jumper J10 is used to select the desired baud rate. Baud rates range from 1200 to 115.2K. The ZCS485 expects a data structure of 1 start bit, 8 data bits and 1 stop bit. Keydown Delay Keydown delay refers to how long a control signal remains active following the last bit of the last character being sent. If the RS-485 transmitter is being controlled by RS-232 TX data (J10 RTS jumper installed), then the transmitter will remain enabled for the time duration specified by the Keydown jumpers following the end of the last character. If the RS-232 DCD signal is based on received RS-485 data (J10 DCD jumper installed), then the DCD signal will remain asserted for the time duration specified by the Keydown jumpers following the end of the last received character. Delays can range from 100us to 12.8ms. CTS Delay The CTS delay jumpers provide a delay from the time the RS-232 RTS signal is asserted until the time the RTS-232 CTS signal is asserted back to the controlling device. This is useful for providing a delay before transmit (keyup delay), and relieves the controlling device from generating precise timing functions. Delays range from 0ms to 12.8ms. 3

J10 Jumper Settings BAUD Rate Selection BAUD2 BAUD1 BAUD0 BAUD RATE ο ο ο 1200 ο ο 2400 ο ο 4800 ο 9600 ο ο 19.2K ο 38.4K ο 56.7K 115.2K KEYDOWN Selection KEYDN2 KEYDN1 KEYDN0 KEYDOWN TIME ο ο ο 100us ο ο 200us ο ο 400us ο 800us ο ο 1.6ms ο 3.2ms ο 6.4ms 12.8ms ο Denotes no jumper installed Denotes jumper installed DATA/DCD Jumper IN DCD RS-232 output based on RS-485 received data OUT DCD RS-232 output based on detected RS-485 carrier DATA/RTS Jumper IN RS-485 transmit enable based on RS-232 transmit data OUT RS-485 transmit enable based on RS-232 RTS signal J13 Jumper Settings RTS to CTS Delay CTS DELAY2 CTS DELAY1 CTS DELAY0 RTS to CTS Delay Time ο ο ο 0 ο ο 200us ο ο 400us ο 800us ο ο 1.6ms ο 3.2ms ο 6.4ms 12.8ms 4

RS-485 RX and TX Jumpers J4 Enable pull-up resistor for RX+ line J3 Enable pull-down resistor for RX- line J2 Terminate RX pair with 120 ohm resistor J7 Enable pull-up resistor for the TX+ line J6 Enable pull-down resistor for the TX- line J5 Terminate TX pair with 120 ohm resistor J8 IN Enables 2-wire operation for both RX and TX pairs (Dual port operation) OUT Enables 4-wire operation RX is receive pair TX is transmit pair J15 Connects isolated RS-485 common to bleed resistor and filter cap Line Termination The ZCS485 s termination jumpers should only be installed if the ZCS485 is physically at one end of the trunk. To terminate the RX pair, install jumpers J2, J3 and J4. To terminate the TX pair, install jumpers J5, J6 and J7. 5

Transient Protection and Grounding Transient Protection The ZCS485 has 2-stages of transient protection. The first stage connects each RS-485 data line to a SiDACtor. The common side of the SiDACtor s are connected to the EARTH terminal of J9 (Figure 1). SiDACtor s provide ultra-fast transient response and provide a path to earth ground for high-voltage transients. The second stage of transient protection uses Transorbs which are connected to the isolated common of the RS-485 section. The Transorbs make sure all transient signals are clamped to within the normal operating voltage of the RS- 485 electronics. Under certain conditions, some devices introduce a large ac or dc voltage on the RS-485 communication lines (referred to as common-mode voltage). This does not present a problem unless the common-mode voltage exceeds the SiDACtor s clamping voltage. If common-mode voltages in excess of 25V are expected, leave the connection from J9-3 (Earth) to ground open so that the SiDACtor s will not try to clamp the common-mode voltage to earth ground. The SiDACtor s and Transorbs will still provide transient protection, but not as effectively for very large transients (lightning for example). Leaving the Earth connection open allows the ZCS485 to operate reliably with common-mode voltages in excess of 100V. Shield Connection The isolated ground or common of the ZCS485 is connected to J1-3 (SHLD). The shield wires of the communication cables are normally connected to this point. Care must be taken to avoid ground loops. Only one end of the shield should be connected to earth ground. Under some conditions other devices may induce a large common-mode voltage on the shield wire. Under these circumstances, leave the ZCS485 s connection to earth ground (J9-3) open (see ZCS485 Transient Protection and Grounding, and Figure 1). Static Control When jumper J15 is installed and J9-3 is connected to earth ground, the ZCS485 provides a bleed resistor which prevents static voltage buildup on the isolated section. The bleed resistor ensures that the isolated section is always at a safe voltage potential. The same connection provides a filter cap which shunts any high-frequency noise that may be induced on the RS-485 communication lines to earth ground. 6

7

Connectors Power (J9) Pin Descripton J9-1 +5 Vdc (ZCS485-5) +8Vdc to +35Vdc (ZCS485-24) J9-2 Common for J9-1 J9-3 Earth Ground RS-232 (J14) Pin Description Signal J14-1 TX Data Input J14-2 RX Data Output J14-3 RTS Input J14-4 CTS Output J14-5 DCD Output J14-6 DSR Output J15-7 Common Ground RS-485 (J1) Pin Description J1-1 RX+ J1-2 RX- J1-3 Isolated Common (Shield) J1-4 TX+ J1-5 TX- RJ11 Pin Description Signal Pin 1 CTS Output Pin 2 TX Data Input Pin 3 no connection Pin 4 Common Pin 5 RX Data Output Pin 6 RTS Input 8

Product Specifications Power ZCS485-5V ZCS485-24V 5Vdc 250mA to 350mA 8 to 35Vdc 300mA to 90mA 110mA @ 24 Vdc typ Operating Temperature 0 to 70 C Operating Modes 4-wire full-duplex 4-wire half-duplex 2-wire half-duplex 2-wire half-duplex Single Port Dual Port Transmit Control RS-232 RTS RTS Mode RS-232 TX Data Data Mode Carrier Detect RS-485 received carrier DCD Mode RS-485 received data Data Mode Delay Functions RS-232 RTS to CTS TX enable delay RS-485 TX Keydown TX turnoff delay DCD Data Delay DCD turnoff in data mode Operation Display TX, RX, RTS, DCD & Power LED s Isolation 1500 Volt Isolation Optically isolated Surge Protection 2-stages of protection Sidactor + Transorb 15kV ESD protection on RS-232 port Power Protection Input reversal protection Transorb surge protection Solid-state fuse Mounting 3.25 Snap Track Curtis Industries, TR3 9

Trouble Shooting Erratic DCD and RX LEDs If the DCD and/or RX LEDs appear to flicker erratically when the ZCS485 is connected to an active RS-485 trunk, a large common-mode voltage may be present. Measure the voltage on the RX+ and RX- lines with respect to earth ground. If the voltage exceeds 25 V (ac or dc), disconnect the ground connection from J9 pin 3. 10

Contact Information ZYPEX, Inc. 2795 E Bidwell Street #100-405 Folsom, CA 95630 (916) 983-9450 (916) 983-9448 fax www.zypex.com info@zypex.com 11

Appendix A Typical Jumper Configurations 12

13

14