WHOLE BODY L-BAND RESONATOR WITH A WIDE RANGE FREQUENCY TUNING USING PIEZO ACTUATOR

Similar documents
PL112 PL140 PICMA Bender

Coil Overlook Coil in MRI system TEM Coil Coil Overlook

5. Transducers Definition and General Concept of Transducer Classification of Transducers

OPTICS IN MOTION. Introduction: Competing Technologies: 1 of 6 3/18/2012 6:27 PM.

PERFORMANCE OF THE TUNER MECHANISM FOR SSR1 RESONATORS DURING FULLY INTEGRETED TESTS AT FERMILAB

Trimmer Capacitors. PTFE Air Tubular Sapphire Air Plate 3mm SMT Microwave Tuning Elements Machining & Turnmill Services

Electronic Measurements & Instrumentation. 1. Draw the Maxwell s Bridge Circuit and derives the expression for the unknown element at balance?

A trimodal resonator for three mutually perpendicular magnetic fields

Chapter 16 PCB Layout and Stackup

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

SELF-QUENCHED SUPER-REGENERATIVE DETECTOR FOR NUCLEAR MAGNETIC RESONANCE BY a SURYAN SUMMARY 1. INTRODUCTION

A Tutorial on Acoustical Transducers: Microphones and Loudspeakers

What are we looking at?

Homework Assignment 03

Improved Ionospheric Propagation With Polarization Diversity, Using A Dual Feedpoint Cubical Quad Loop

COOPERATIVE PATENT CLASSIFICATION

HTC Technical Manual

EPR spectrometer & components

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

LBI-30398N. MAINTENANCE MANUAL MHz PHASE LOCK LOOP EXCITER 19D423249G1 & G2 DESCRIPTION TABLE OF CONTENTS. Page. DESCRIPTION...

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Oscillators III. by Werner Wiesbeck and Manfred Thumm. Forschungszentrum Karlsruhe in der Helmholtz - Gemeinschaft

Technology. Construction of magnetic buzzer. Construction of magnetic buzzer. Operation principles and construction

ERICSSONZ LBI-30398P. MAINTENANCE MANUAL MHz PHASE LOCKED LOOP EXCITER 19D423249G1 & G2 DESCRIPTION TABLE OF CONTENTS

Lab 4. Crystal Oscillator

PVA Sensor Specifications

Wireless Power Transfer. CST COMPUTER SIMULATION TECHNOLOGY

Proceedings of Meetings on Acoustics

Low-Level RF. S. Simrock, DESY. MAC mtg, May 05 Stefan Simrock DESY

VARIABLE INDUCTANCE TRANSDUCER

Application Note 5525

Resonator System for the BEST 70MeV Cyclotron

Simple Quartz Crystal Models: A Review

UNIT II MEASUREMENT OF POWER & ENERGY

Design and RF Measurements of an X-band Accelerating Structure for the Sparc Project

Figure Cutaway view of the Phasitron tube, which is used as the modulator and upon which the operation of the GE f-m transmitter is based.

AN5258. Extending output performance of ST ultrasound pulsers. Application note. Introduction

A Superheterodyne Spectrometer for EPR and ENDOR"

A short, off-center fed dipole for 40 m and 20 m by Daniel Marks, KW4TI

Moveable Probe Thick Silver Plated

Fabry Perot Resonator (CA-1140)


Types MCM and MIN SMT Clad RF Capacitors

Actively Stabilized Scanning Single-Frequency. Ti:Sa /Dye Ring Laser External Doubling Ring Ti:Sa /Dye Standing Wave Laser

CONSTRUCTION OF A DUAL TUNED COIL

When asked this riddle, 80% of kindergarten kids got the answer compared to 17% of Stanford University seniors.

Miniaturising Motion Energy Harvesters: Limits and Ways Around Them

Chapter 6. FM Circuits

Workshop on Rapid Scan EPR. University of Denver EPR Center and Bruker BioSpin July 28, 2013

Introduction Introduction to radio frequencies p. 3 What are the 'radio frequencies'? p. 3 Why are radio frequencies different? p.

EE301 ELECTRONIC CIRCUITS CHAPTER 2 : OSCILLATORS. Lecturer : Engr. Muhammad Muizz Bin Mohd Nawawi

Operation Manual. Model SG Elenco Precision Wide Band Signal Generator

Types MC and MCN Multilayer RF Capacitors

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

Tuning systems for superconducting cavities at Saclay

Microwave cavity tuned with liquid metal and its application to Electron Paramagnetic Resonance arxiv: v1 [physics.ins-det] 10 Apr 2018

CST MWS simulation of the SARAF RFQ 1.5 MeV/nucleon proton/deuteron accelerator

A Novel Electromechanical Interrogation Scheme for Implantable Passive Transponders

Introduction of Receivers

(i) Determine the admittance parameters of the network of Fig 1 (f) and draw its - equivalent circuit.

A Pulse NMR experiment for an undergraduate physics laboratory

A Narrow-Band Tunable Diode Laser System with Grating Feedback

Applications Note RF Transmitter and Antenna Design Hints

LC31L-BAT Link Coupler

Table of Contents Lesson One Lesson Two Lesson Three Lesson Four Lesson Five PREVIEW COPY

CAVITY TUNING. July written by Gary Moore Telewave, Inc. 660 Giguere Court, San Jose, CA Phone:

CONSTRUCTING A SCANNING TUNNELING MICROSCOPE FOR THE STUDY OF SUPERCONDUCTIVITY

The University of Texas at Austin Electron Paramagnetic Resonance Facility. Bruker EMX+ CW EPR Spectrometer

- Datasheet - Features: Version 1.1. Cryogenic Low Pass Filter Unit Type KA-Fil 2a

SUBELEMENT T6 Electrical components: semiconductors; circuit diagrams; component functions 4 Exam Questions - 4 Groups

Actively Stabilized Scanning Single Frequency. Ti:Sa /Dye Ring Laser

Feedback Amplifier & Oscillators

Passive external radio frequency filter for Langmuir probes

PRINCIPLES OF RADAR. By Members of the Staff of the Radar School Massachusetts Institute of Technology. Third Edition by J.

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

Improving CDM Measurements With Frequency Domain Specifications

AC bridge circuits. A balanced bridge shows a null, or minimum reading, on the indicator.

FIELD TUNING INSTRUCTIONS

3d System Integration Simulation

RX Directional Antennas. Detuning of TX Antennas.

Recording EPR Spectra using ER 4102ST Resonator

1. Each group will get one aluminum BUD chassis (also called BUD box ).

INC. MICROWAVE. A Spectrum Control Business

A Low-Loss VHF/UHF Diplexer

LM1866 Low Voltage AM FM Receiver

GATE: Electronics MCQs (Practice Test 1 of 13)

Telemetrie-Messtechnik Schnorrenberg

High Q Tunable Filters

Magnetic and Electromagnetic Microsystems. 4. Example: magnetic read/write head

The Facts about the Input Impedance of Power and Ground Planes

HIGH POWER PULSED TESTS OF A BETA=0.5 5-CELL 704 MHZ SUPERCONDUCTING CAVITY

UNIT 2. Q.1) Describe the functioning of standard signal generator. Ans. Electronic Measurements & Instrumentation

1. Farad is a unit of (a) Resistance (b) Inductance (c) Capacitance. (d) Frequency.

INSTRUCTION MANUAL. In vivo Test Apparatus for 305B Muscle Lever Systems

Design of an 80kV, 40A Resonant SMPS for Pulsed Power Applications

High Voltage Engineering

RF MEMS for Low-Power Communications

RF Engineering: Live Construction of A Coil Let s build an RF human coil. Hiroyuki Fujita, Ph.D. 1,2,3,4,5 with Tsinghua Zheng, MSEE 1,2

GATES WITH BUT 3 PERCENT FREQUENCY SEPARATION DIPLEXING AM TRANSMITTERS GATES ENGINEERING REPORT HARRIS I NTE RTYPE A DIVISION OF HARRIS-INTERTYPE

Transcription:

Current Topics in Biophysics 2002, 26(1), 15-19 WHOLE BODY L-BAND RESONATOR WITH A WIDE RANGE FREQUENCY TUNING USING PIEZO ACTUATOR PAVEL CEVC 1, TADEUSZ WALCZAK 2, HAROLD M. SWARTZ 2 1 Jozef Stefan Institute, 1000 Ljubljana, Jamova 39, Slovenia; 2 Dartmouth Medical Shool, Hanover, NH 03755-3868, USA. Measurements by present in vivo L-band EPR often are enhanced by using whole body resonators, but use of such resonators are connected with several challenging problems. One is the relatively large change in the resonator frequency caused by voluntary and involuntary movements of the animal. To overcome this, we designed a loop gap resonator (600 and/or 1200 MHz) with a metal plate that is a part of the resonators capacitor that can be displaced by a piezo bender. We have used a recently developed multilayer, low voltage non-magnetic piezo bender, that bends up to 0.5 mm, which is sufficient to change the resonant frequency by about 15 MHz. With the use of an automatic frequency control (AFC) system, this tuning range is sufficient to keep the resonant frequency constant and to compensate for the effects caused by the movements of the investigated object. A step motor is used as the base of the mechanical part of the matching adjustment INTRODUCTION The development of in vivo ESR Low- Frequency spectroscopy as a powerful and versatile method depends on solving several practical problems. One of the most critical challenges for this technique is animal motion, which can cause mismatching and detuning of the resonator, resulting in distortions or complete loss of the signal. To keep the resonant frequency and matching constant, automatic frequency control (AFC) and matching control (AMC), can be used. Automatic tuning and matching circuits that use varactor diodes, piezoelectric transducers, or electromchanical transducers have been utilized. Each approach has benefits and deficiencies. The advantage of the varactors based system is fast response of AFC circuitry. On the other hand, varactors are sensitive to the magnetic field modulation and special shielding is needed. Also, use of varactor diodes when AFC and AMC is used can generate second harmonics when the power is greater than 100 mw. The resonant frequency also can be changed by mechanical movement of a capacitor plate that is a part of the resonant structure. Hyde at al. (Hyde, Rilling, Jesmanowicz & Kneeland, 1989) have used a piezoelectric bimorph disk to adjust the tuning capacitor of the nuclear magnetic resonance (NMR) surface coil. A similar system has been used by McCallum et al. (McCallum & Resmer, 1999) where the piezoelectric disk actuator was used to change the capacity of the coupling capacitor of a low frequency EPR spectrometer. Recently a new multilayer bender actuators became commercially available (Physik Instrumente GmBH&Co., Waldbron, Germany). The positioning range of these multilayer benders are an order of magnitude larger than the previous design. Since these benders are made of nonmagnetic materials and also employ low operating voltage (60 Vmax.), they are very convenient to construct voltage controlled variable capacitors. The larger displacement available enable the design of a control system that is smaller and therefore less sensitive to audio noise. As a result the spectrometer s sensitivity can be improved. TECHNICAL DESCRIPTION Resonator design We used a bridge loop gap resonator (BLGR) whose structure was supported by a quartz tube of 30mm diameter. The schematic diagram of the resonator is on Fig. 1. The resonant frequency can be adjusted either by changing the dimensions of capacitors plates or by varying the distance between the capacitor plate and the loop. We have used teflon tape to fix the loop and the capacitor copper plates (20 mm wide stripes). We adjusted the resonator frequency by changing the distance between the plates and the loop.

16 Pavel Cevc et al. Fig. 1. Schematic of a piezo-controlled whole body resonator One of the bridge capacitor plates was split into two parts. One half was fixed by teflon tape while the second part was left free and mechanically coupled with a piezoelectric bender. By splitting the electrode plate we could change the distance of one half of the plate sufficiently to change the resonant frequency (up to 15 MHz) for the operation of the AFC system. Since the second half of the capacitor is fixed, the whole cavity structure is less sensitive to microphonics, improving the spectrometer s signal to noise ratio. Piezoelectric control and measurements The new generation of multilayer piezoelectric benders have a range of movement up to 2 mm and can be operated with low voltages (60 V max). We have used the smallest model (PL-122.251), which has a displacement up to 0.5 mm. The 25 mm long bender is clamped at one side and fixed to the aluminum housing of the whole body cavity, while the second side is mechanically coupled to the mobile part of the resonant capacitor by a 14 mm long quartz tube. This electrode was made from 0.1 mm thick phosbronze plate with a round shape to fit the curvature of the quartz cavity body. All of the plates of the resonator structure were silver plated. Changes to the resonant frequency by moving the electrode can be done in two ways: by mechanical repositioning of the piezobender and electrode position to provide a coarse adjustment, and electromechanically by changing the voltage applied to the piezobender. Fig. 2 shows the dependence of the resonant frequency on control voltage with the empty resonator (graph 2A) and loaded with mouse (2B). We can see, that there is some hysteresis, which has been observed previously (McCallum & Resmer, 1999).

Whole body L-band resonator 17 A B Fig. 2. Resonant frequency dependence on control voltage: A: empty resonator; B: loaded (with mouse) MATCHING CONTROL The bridge loop whole body resonator we have designed is equipped with magnetic type of coupling. To reduce the influence of coupling adjustment on the resonator frequency, a flexible impedance transformer was used connecting the coupling loop to the transmission line (Hirata, Walczak & Swartz, 1997). By changing the distance between the resonant structure and the single turn loop, we can vary the coupling and match the cavity to a RF source. Very often a simple screw is used to change the distance. This can be inconvenient, however, so we have used a step motor controlled movement of the coupling coil. Fig. 3 shows the schematic of the whole system. Since a standard step motor can rotate in 0.9 degree steps and using a 6.3 mm diameter motor shaft, we achieved translational shifts of 50 microns. Changing the coupling loop position and measuring the reflected power from the cavity with a detector diode, we obtained the

18 Pavel Cevc et al. Fig 3.: Schematic of coupling loop control using step motor. a frequency of several Hertz could be achieved. We believe that this is fast enough to use ACC control electronics, with which most of the animal movements could be compensated. This is the subject of our ongoing investigation. Fig. 4. Resonator coupling vs number of motor steps. At zero position coupling is critical, by rotating in one or another direction we can under or over couple the cavity to the RF source. dependence on resonator coupling shown on Fig. 4. The change in coupling from under coupled to over coupled was achieved with 90 steps, that correspond to 4.5 mm of total coil movement. It should be noted that the small step motor used (Type 4H4018L0502, Nanotec, Munchen, Ge) could change the direction of rotation quite fast, so CONCLUSIONS The availability of a new generation of piezo benders offers the possibility for construction of improved automatic frequency and coupling controls of resonators. We have used a piezo bender with up to 0.5 mm displacement range to control the resonant frequency of a 600-650 MHz whole body resonator. The resonator resonance frequency change of 15 MHz that was obtained is sufficient for AFC electronic control. In addition to the resonator frequency change that is caused by movements of animals, the coupling also is effected. We have introduced a step motor control that moves a single turn coupling loop to match the resonator and RF source. We believe that this proposed step motor controlled matching adjustment will be fast enough to use ACC electronics.

Whole body L-band resonator 19 REFERENCES Hirata H., Walczak T. & Swartz H. M. (1997). An improved inductive coupler for suppresing a shift in the resonance frequency of electron paramagnetic resonance resonators. Rev. Sci. Instr. 68, 3187-9. Hyde J. S., Rilling R. J., Jesmanowicz A. & Kneeland J. B. (1989). Piezoelectric-controlled tuning capacitor for surface coils. Magn. Reson. Med., 12, 50-55. McCallum S. & Resmer F. (1999). Automatic coupling control system for radio frequency in vivo electron paramagnetic resonance based on a piezoelectric controlled capacitor. Rev. Sci. Instr., 70, 4706.