EC centrifugal fan - RadiCal

Similar documents
EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

AC centrifugal fan. backward curved

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal

AC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC diagonal compact fan

EC centrifugal fan. forward curved, single inlet with housing (flange)

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

EC centrifugal fan. forward curved, dual inlet with housing (flange)

onlinecomponents.com

AC axial compact fan

AC centrifugal fan. forward curved, single inlet with housing (flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC centrifugal fan - RadiCal

AC axial fan. sickled blades (S series)

EC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data

AC axial compact fan

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC axial compact fan

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (large flange)

EC centrifugal fan - RadiCal

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. forward-curved, dual-intake with housing (flange)

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

EC centrifugal fan. R3G175-AF25-02 backward curved, single inlet. Nominal data

DC axial compact fan

EC/AC axial fans - HyBlade Ø

Tangential Fans - Basic principles. Expertise, performance, innovation

Product Data Sheet 8452/2HHP. The engineer's choice

Product Data Sheet 3252J/2H3PU

Product Data Sheet RG160-28/18N/2TDPU-331

Product Data Sheet RER225-63/18/2TDO- 406

Product Data Sheet 6424/2HP-210

Product Data Sheet 3254 J/2H3P

Soğutmada büyük beden modası

Product Data Sheet 8214 J/2H4P. The engineer's choice

Product Data Sheet RER190-39/14/2TDMO

Product Data Sheet RER220-43/18/2TDMO

Product Data Sheet 8452/2 GHHP

Product Data Sheet 622/2HHP-021

Product Data Sheet 8214 J/2H4P

Product Data Sheet 6314/2TDHP. The engineer's choice

Specification For Approval

Product Data Sheet DV4112/2NP-201

DC Axial Fans. ebm-papst St. Georgen. Noise

Automotive BL-DC Fans for Commercial Vehicles. Edition

Tangential blowers with multiple housings. Optimized air flow steady distribution.

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

C B. Models. Models 2MOPP

Specification For Approval

Safety switches with slotted hole lever

LED Driver Constant voltage

Cross Flow Fans. Additional Information. Cooling Fans. Introduction E-85 MF Series E-88 MFD Series E-92

Solid-state Timer H3DS

Electrical height adjustment. ... easy & reliable. Multilift II telescope Multilift II. Synchron

Electromagnetic flowmeters and switches DWM 1000/2000

Subject to changes 11/2003 Page 1/7

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

92 38 mm. Reversible Flow Fan. 9RF type. Features. Common Specifications. Specifications. Reduces the required number of fans

Installation and Operating Instructions for Phase Demodulator Type _.2

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

LED Driver Constant voltage

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

-1 ] temperature life [V]

Differential pressure sensors

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

J IPC IGBT power converter

MCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description

SALES SERVICE +358 (0)

Split case double suction centrifugal pump. Technical data Serie: DPAS C

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Digital indicator for panel mounting With multi-function input Model DI25

NEW PRODUCT INFORMATION

NEW PRODUCT INFORMATION

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

Transcription:

R3G9-RB- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart HRA 59344 General partner Elektrobau Mulfingen GmbH Headquarters Mulfingen County court Stuttgart HRB 594 Nominal data Type Motor R3G9-RB- M3G55-BD Phase ~ Nominal voltage VAC Nominal voltage range VAC.. 4 Frequency Hz /6 Type of data definition ml Speed min - 7 Power input W 57 Current draw A.43 Min. ambient temperature C -5 Max. ambient temperature C +6 ml = Max. load me = Max. efficiency fa = Running at free air cs = Customer specs cu = Customer unit Subject to alterations Item no. 783-5-998 Revision 7787 Release 3--7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 () 7938 8- Fax +49 () 7938 8- info@de.ebmpapst.com www.ebmpapst.com

R3G9-RB- Technical features Mass Size Surface of rotor Material of electronics housing Material of impeller Number of blades 7 Direction of rotation kg 9 mm Type of protection IP 54 Insulation class Max. permissible ambient motor temp. (transp./ storage) Min. permissible ambient motor temp. (transp./storage) Mounting position Condensate discharge holes Operation mode Motor bearing Thick layer passivated Die-cast aluminium Plastic PA6, fibreglass-reinforced Clockwise, seen on rotor "B" + 8 C - 4 C Any None, open rotor S Ball bearing Technical features - Speed adjustment input ( V) - Motor current limit - Soft start - Over-temperature protected electronics / motor Speed steps EMC interference immunity Acc. to EN 6-6- (industrial environment) EMC harmonics Acc. to EN 6-3-/3 EMC interference emission Touch current acc. IEC 699 (measuring network Fig. 4, TN system) Motor protection Cable exit Protection class Acc. to EN 6-6-3 (household environment) <= 3.5 ma Locked-rotor protection Variable Product conforming to standard EN 6335- Approval I (if protective earth is connected by customer) CCC Item no. 783-5-998 Revision 7787 Release 3--7 Page / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 () 7938 8- Fax +49 () 7938 8- info@de.ebmpapst.com www.ebmpapst.com

R3G9-RB- Product drawing Accessory part: Inlet nozzle 9576--43, not included in the standard scope of delivery Connection line AWG, 4 x brass lead tips crimped 3 Depth of screw max. 6 mm Item no. 783-5-998 Revision 7787 Release 3--7 Page 3 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 () 7938 8- Fax +49 () 7938 8- info@de.ebmpapst.com www.ebmpapst.com

R3G9-RB- Connection screen Line No. Signal Colour Function / assignment CON L black Power supply VAC, - 6 Hz, see type plate for voltage range CON N blue Neutral conductor CON PE green/yellow Protective earth CON 7 SL brown Speed selection: switch open = speed ; switch closed = speed Item no. 783-5-998 Revision 7787 Release 3--7 Page 4 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 () 7938 8- Fax +49 () 7938 8- info@de.ebmpapst.com www.ebmpapst.com

R3G9-RB- Charts: Air flow Hz Druck p f s[pa]für Rho=,kg/m^3 5 qv[cfm] 3 3 4 48 46 44 4 4 38 36 34 3 3 8 6 4 8 4 3,9,8,7,6,5,4,3,,,9 pfs_e[in HO] Measurement: LU-5487 Measurement: LU-5489 Air performance measured as per ISO 58 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 3347 / LpA measured with m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.,8 8 6 4 7,7,6,5 8 6 4 3 3 qv[m^3/h] 4 6 4 5 5 6 6,4,3,, 7 Measured values 3 4 5 6 7 8 U V f Hz n min - 88 85 7 8 435 395 35 385 P ed W 49 5 57 5 3 3 35 3 I A.36.4.43.4.3.5.7.5 LpA in db(a) 6 56 54 6 LwA in db(a) 69 64 6 68 qv m 3 /h 64 5 395 53 455 33 7 p fs Pa 4 34 83 7 4 U = Supply voltage f = Frequency n = Speed P ed = Power input I = Current draw LpA in = Sound pressure level inlet side LwA in = Sound power level inlet side qv = Air flow p fs = Pressure increase Item no. 783-5-998 Revision 7787 Release 3--7 Page 5 / 5 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 () 7938 8- Fax +49 () 7938 8- info@de.ebmpapst.com www.ebmpapst.com