Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Similar documents
Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC 0-10VDC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Status Ouputs. Control Input. 0 to 24VDC 1A AC/DC. 4-20mADC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

Control Input. Status Ouputs. 0 to 24VDC 1A AC/DC. Fig. 1 TYPICAL APPLICATIONS Fig. 2 WIRING DIAGRAM

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

celduc r e l a i s Proud to serve you MOSFET BASED DC SOLID STATE RELAY SCM VDC 600VDC 40ADC Page 1/5 GB

celduc r e l a i s Proud to serve you celduc MOSFET BASED DC SOLID STATE RELAY SCM VDC 200VDC 100ADC Page 1/5 GB

IGBT BASED DC SOLID-STATE RELAY. In & case / Out Insulation. Fig. 2. Please consult us to select the right protective components C1, D1 & D2.

PRELIMINARY DATA MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig.

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

MOSFET BASED DC SOLID-STATE RELAY. In & case / Out Insulation VDC 2.5kV Screw terminals 45 x 58.5 x 30 80g. Fig. 2

MOSFET BASED DC SOLID-STATE RELAY (With built-in transient voltage suppressor) In & case / Out Insulation

celduc r e l a i s Proud to serve you XKLD31006 DOCUMENT PRELIMINAIRE RELAIS STATIQUE A MOSFET POUR COURANT CONTINU 10-30VDC 40V (60V crête) 10ADC

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

celduc SILD r e l a i s celpac PATENTED! AC Semiconductor Contactor pitch 22,5mm with Diagnostic compact size and DIN rail mounting.

NEW Series EMC48S50-04

celduc SIM Phase angle controller Output : VAC 40A(*) Input : Analog 0-10V r e l a i s celpac

celduc SIL Phase angle controller Output : VAC 32A(*) Input : Analog 0-10V celpac r e l a i s Proud to serve you

celduc SILD Output : VAC 32A(*) Input : 3-32VDC - I<10mA Diagnostic : 30VDC - 100mA r e l a i s celpac P roud to serve you

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Type CP-S, CP-C & CP-A Switch mode

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Three-phase monitoring relays

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

CP-T range Product group picture

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Electronic timer CT-SDS.22

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

CP-T range Benefits and advantages

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

RN Thyristor Controllers

CP-E range Benefits and advantages

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDD.22

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFS

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-T 24/40.0 Primary switch mode power supply

SOLID STATE RELAY RATINGS

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Solid State Relays 1-Phase, Zero Cross or Instant On Switching 25 AAC, 230 VAC with LED and Built-in Transil Types RF1A, RF1B

NEW Series STH Output to 75A, 600 Vac High Industrial Performance (HIPpak) Solid-State Relays

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Semiconductor contactors, Solid-state relays

Semiconductor contactors, Solid-state relays

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-E 24/0.75

Power supply CP-T 48/5.0 Primary switch mode power supply

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Power supply CP-D 24/4.2 Primary switch mode power supply

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Energy Management Energy Meter Type EM110

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Electronic timer CT-TGD.22

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Primary switch mode power supplies Product group picture

Solid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.

Rated power VA (50 Hz)/W 0.6/ / / /0.3 Operating range V AC (50/60 Hz)

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Power supply CP-T 24/20.0 Primary switch mode power supply

RP1A, RP1B. 1-phase PCB mount solid state relays. Main features. Description

Power supply CP-E 24/2.5

Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

38 Series - Relay interface modules A

38 Series - Relay interface modules A

QUINT-PS AC/24DC/40

Solid State Relays 1-Phase with Integrated Heatsink Soft Start Switching Types RGC1P..K..

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-T 48/20.0 Primary switch mode power supply

Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..

QUINT-PS/ 3AC/24DC/10

Power supply CP-D 12/2.1

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Industrial, 2-Pole ZS Type RA2A

Three-phase monitoring relays CM-PFE and CM-PFE.2

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

QUINT-PS-24DC/24DC/10

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Power supply CP-D 24/1.3

Transcription:

Page 1/6 GB DIGITAL THREE PHASE ANGLE CTROLLER Allows to set the voltage applied to different sort of loads with 3 wires, 4 wires or inside the delta wiring: Resistive (Bulbs, UV and IR lamps, ovens, ), Inductive (inductors, transformers, ), Motor (motorfan speed control (60 to 100% from the nominal speed), Rectified (power supplies, ). Small housing, easy and ready to use. Large mains frequency and voltage range. Fully optoisolated full cycle three phase phase angle controller (balanced currents, less harmonics, ) Dynamic control voltage range according to the power factor of the load. Softstart and softstop functions (increase lifetime expectancy of the load). Adjustable filter regarding fast input voltage changes (ramps). Motor softstarting functions to control its speed within the stable area. Input-output transfert characteristic linearization function (resistive load). Diagnostic features : Status given on LED and AC/DC switches. SWTA4650 Proportionnal analog voltage control input 0-10V 200->480VAC 50A AC-51 @40 C (heatsink fan voltage = 230VAC) Mains Voltage 200 to 480VAC Mains Frequency 40 to 65Hz Max AC-51 Current 50A (70A) @40 C Max AC-53a Current 30A @40 C Control Input 0-10VDC Status Ouputs 0 to 24VDC 1A AC/DC In / Out Insulation 4kV Wire Size In=2.5mm² Out=10mm² Dimensions (WxHxD) 110x141x180 (mm) Weight 2600g Fig. 1 TYPICAL APPLICATIS Fig. 2 WIRING DIAGRAM Fig. 3 PHASE ANGLE CTROL DESCRIPTI Fig. 4 INTERNAL DIAGRAM Proud to serve you Data given at Tambient=40 C and subject to modification without previous notice

Page 2/6 GB SETTINGS Label Ramp Time (s) Initial Value Soft Stop Comp Load Ntrl Curve Description SETTINGS AND OPTIS Function Setting possibilities White squares = buttons Example : Ramp up time (Softstart and smooth transients) Initial load voltage (footstep) Ts= 0 to 64s Vi=0 to 100 % Ramp down time 0 x ts = 0.5 x ts = ts = Allows to adapt the control signal range whatever the power factor of the load Ask the unit to make a softstart up to the max. before analog control. Tells the unit the load star point is connected to the mains neutral Tells the unit what kind of inout response to use (angle or RMS voltage linearity) On (Up) On (Up) On (Up) On (Up) Inductive load Motor Star wiring with neutral (4 wires) RMS voltage control Off (Down) Off (Down) Off (Down) Off (Down) = all switches down () (factory setting) 2 x ts = Resistive load Other loads than motors Delta or star without neutral Phase angle control INPUT CHARACTERISTICS CHARACTERISTIC LABEL VALUE INFO. Labels 0-10V Urg. Stop Function Analog control input Stop the thyristor controls INPUT CIRCUIT Control type DC control voltage Opening the connection between 5 & 6 Terminals 4 & 6 5 & 6 Control voltage range Uc 0-10VDC - Release and control threshold voltage Ucsmin 0.3VDC - Full power threshold control voltage Ucsmax 9.7VDC - Max. input voltage Ucmax 30VDC 6VDC Max. reverse voltage -Ucmax 30VDC 6VDC Release voltage Ut >1,5V Input impedance Re 100k - See fig. 5 Current to switch Ict - 20mADC Ict=f(Ut) Labels Diag. Pwr Terminals 1 & 2 2 & 3 STATUS OUTPUTS Function Indicates a problem detected in the circuit configuration Nominal operating voltage Usan 24VAC/DC Operating voltage range Usa 0->28VAC/DC Max. peak voltage Usap 60V Overvoltage protection Built-in 25V size7 varistors Minimum load current Ipw/Ipb 0A Indicates the load is supplied Maximum load current Ipw/Ipb 1A AC/DC See fig. 6 Maximum overload current Ipw/Ipb 2.4A AC/DC @100ms 10% of the cycle On and off state switch resistance Ron / Roff 500m / 100M See fig. 6 On and off time delay Ton / Toff 0.5ms / 2ms

Page 3/6 GB OUTPUT CHARACTERISTICS CHARACTERISTIC LABEL VALUE INFO. Mains voltage range Ue 200 -> 480VAC Non-repetitive peak voltage Uep 1200V Overvoltage protection VDR Built-in 510V size 14 varistors Maximum nominal currents Nota : Wire cross section limited to 10mm² (50A) by the terminals Maximum line currents in delta wiring Ie ILine Resistive Ithmax AC51 50A (70A) 87A (121A) Resistive Ith AC51 50A (EN60947-4-3) 87A (EN60947-4-3) Motor Iemax AC53a 30A 52A Motor Ie AC53a 22A (EN60947-4-2) 38A (EN60947-4-2) @40 C See fig. 7 Delta wiring : See installation manual Puissance moteur max. Pe 15kW @400VAC connexion étoile @40 C Non-repetitive peak overload current (1 cycle of 10ms) Melting limit for choosing the protective fuses ITSM 2000A See fig. 8 I²t 20000A²s @10ms Minimum load current Iemin 100mA Maximum leakage current Ielk 7mA @400VAC 50Hz Power factor Pf 0->1 Mains frequency range F 40->65Hz POWER CIRCUIT Max. off-state voltage rise dv/dt 500V/µs Protection against fast voltage transients Buit-in RC network Max. current rise di/dt 50A/µs On-state voltage drop Ud 1.4V @Ith Resistive part of the voltage drop rt 2m @125 C Potential part of the voltage drop Vto 0.9V @125 C Maximum junction temperature Tjmax 125 C Junction/case thermal resistance per power element Case heatsink thermal resistance Rthjc Rthcs 0.25K/W 0.05K/W Total = 3 power elements Built-in heatsink thermal resistance vertically mounted Rthra 0.3K/W @ Tra=60 C Heatsink thermal time constant Tthra 15min @ Tra=60 C Inputs/power ouputs insulation voltage Input/status outputs insulation voltage Uimp Uied 4kV 2.5kV Inputs/case insulation voltage Uimp 4kV Status outputs/case insulation voltage Uimp Isolation resistance Rio 1G Isolation capacitance Cio <8pF Storage ambient temperature Tstg -40->+100 C 4kV Operating ambient temperature Tamb -40->+90 C See fig. 7 Max. heatsink temperature Tc 100 C

Page 4/6 GB INTERNAL POWER SUPPLY INTERNAL POWER SUPPLY CHARACTERISTIC LABEL VALUE INFO. Terminals 3L2 & 5L3 Mains voltage range Ue 200->480VAC Consumption Is 1mA typical Mains frequency range F 40-65Hz Turn-on time tm 100ms GENERAL INFORMATI CNEC- TIS Connections Power Input terminal block Screwdriver advised Posidriv 2 or 0.8 x 5.5mm 0.8 x 2mm Min and max tightening torque Number and cross section of the wires Screwdriver for settings 1.8->3N.m 2 x 1.5->6mm 2 (10mm 2 without ferrule) 0.8 x 2mm 1 x 2.5mm 2 MISC. Housing Mounting Noise level Weight UL94V0 Omega DIN rail (DIN50022) or screwed Low audible vibrations 2600g STANDARDS GENERAL Standards Protection level Protection against direct touch CE marking UL, culus and VDE approvals EN60947-4-2 & EN60947-4-3 IP2L0 Accordin to V.D.E. 160 part 100 : Back hand and finger safety Yes Pending TYPE OF TEST STANDARD LEVEL EFFECT E.M.C. IMMUNITY E.S.D. (Electrostatic discharges) EN61000-4-2 8kV (air) 4kV (touch) No effect Radiated electromagnetic fields EN61000-4-3 10V/m No effect Fast transients bursts Electric chocks EN61000-4-4 EN61000-4-5 2kV direct coupling on the power side 2kV coupling by clamp on the input side 1kV direct coupling differential mode (input and output) 2kV direct coupling common mode (input and output) Voltage drop EN61000-4-11 - No effect No effect E.M.C. EMISSI Radiated and conducted disturbances NFEN55011 The conducted or radiated disturbances generated by solid state relays depend on the wiring and load configuration. The test method recommended by the European standards and concerning electromagnetic compatibility leading to results far from reality, we decided to advise our customer in order to adapt their filtering scheme to their application. Please refer to the SVTA SWTA installation manual.

Page 5/6 GB CHARACTERISTIC CURVES Fig. 5 INPUT CHARACTERISTIC Fig. 6 CURRENT AND RESISTANCE VS TEMPERATURE Fig. 7 POWER DISSIPATED AND LOAD CURRENT LIMIT VS TEMPERATURE Please refere to the installation notice for precautions about mounting the device. Fig. 8 CURRENT OVERLOAD CHARACTERISTIC (ITSM PER POWER ELEMENT)

Page 6/6 GB DIMENSIS AND ACCESSORIES Fig. 9 DIMENSIS CHARACTERISTIC LABEL VALUE INFO. THERMAL PROTECTI Contact type Closing temperature Normally closed 90 C +/-3 C Opening temperature 80 C Nominal voltage Nominal current Contact resistance Insulation between opened contacts Insulation between housing and contacts Isolation resistance Connections 250VAC/DC 6A 10m 10G 4kV 10G 2.8mm flat tabs or welded wires FAN Motor Supply voltage Consumption Supply frequency Speed Noise level Connections Shaded pole induction motor 230VAC 9W 68mA 50->60Hz 2600 RPM 35dbA 2.8mm flat tabs www..com 5 Rue Ampère B.P. 30004 42290 SORBIERS - FRANCE E-Mail : -relais@.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tél. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19

Supply LED DISPLAY Line Up Load Down OUTPUTS Pwr Diag. SVTA-SWTA DIAGNOSTIC LOAD NORMAL OPERATI COMMENTS ANALOG INPUT VOLTAGE BELOW THE MINIMUM CTROL VOLTAGE THRESHOLD DIAGNOSTIC Phase presence = OK ; Phase voltage = OK ; Phase frequency = OK LEDs blinking sequence indicates mains phase rotation is direct Load connected Analog input voltage below the minimum control voltage threshold (0.3V (0-10V) ; 4mA (4-20mA) ; 0.15V (0-5V / potentiometer)) DIAGNOSTIC Phase presence = OK ; Phase voltage = OK ; Phase frequency = OK LEDs blinking sequence indicates mains phase rotation is reverse Load connected Analog input voltage below the minimum control voltage threshold (0.3V (0-10V) ; 4mA (4-20mA) ; 0.15V (0-5V / potentiometer)) ANALOG INPUT VOLTAGE ABOVE THE MINIMUM CTROL VOLTAGE THRESHOLD Indicates the voltage at the analog input or the voltage ramp set by the user (Time ramp (s)) is increasing. Indicates the voltage at the analog input exceeds the maximum full power threshold voltage (9.7V (0-10V);19.7mA (4-20mA);4.9V (0-5V / potentiometer)) Indicates the voltage at the analog input or the voltage ramp set by the user (soft-stop) is decreasing. Stable analog input voltage or voltage ramps finished (if used) NOTA : A fast UP/DOWN LEDs blinking can occur Supply LED DISPLAY Line Up Load Down OUTPUTS Pwr Diag. ABNORMAL OPERATI LOAD POSSIBLE CAUSE SOLUTI WHATEVER IS THE VOLTAGE VALUE AT THE ANALOG INPUT Mains is missing or it is connected on the motor side (2T1, 4T2, 6T3) of the device, instead of the mains side (1L1, 3L2, 5L3) Mains voltage too low 1 or 2 phase(s) missing, Mains frequency out of range, Too many disturbances Microcontroller malfunction or too many problems at the same time Load connection missing, Shorted thyristor (s) A problem on the main occurred (e.g. phase missing) and now it is OK but analog input voltage is present A problem on the load occurred (e.g. temporary disconnection) and now it is OK but analog input voltage is present Check the power side wiring Check phase to phase voltage between 3L2 and 5L3 Check the phases Disconnect the device from the mains for a while and check the wiring Check load connections and measure the power element resistance (should be several 100kOhms) Remove the analog input voltage for a while Remove the analog input voltage for a while Factory diagnostic Consult us ANALOG INPUT VOLTAGE ABOVE THE MINIMUM CTROL VOLTAGE THRESHOLD Power elements can not turn on 1 or 2 phase(s) missing, Mains frequency out of range, Too many disturbances LEGENDE Check connection between 5 and 6 of the control terminal block. Check the load current is above the minimum specified Check the phases GREEN RED BLINKING /GREEN BLINKING /RED

IMPORTANT INFORMATI CCERNING THE DIAGNOSTIC 1- The device makes a complete diagnostic (mains, load and itself) as soon as the mains voltage is sufficient 2- The device checks only the presence of phases when the analog input voltage is above the minimum control threshold, during the ramps (softstart and softstop) and when it is full on (the power elements are tested only when analog control voltage is below the minimum control voltage threshold). 3- The control overrides the diagnostic. - If a problem occurs during the control period, the device will try to go on driving the load according the analog input voltage. If the problem goes on, it will be if possible indicated to the user according the diagnostic table. - If a problem occurs during the softstopping period, the device will stop immediately in order to reach the off state diagnostic period. PRELIMINARY 22/01/04