High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

Similar documents
Calio SI First and only circulator designed and produced in Turkey

TECHNICAL DATA. ErP R eady NewMotorTechnolgy. FERRIER PUMPS LTD Edinburgh Glasgow Aberdeen

UNISELB. Self-priming dirty water pump

Lowara. Centrifugal pumps with open impeller and flanged connections. SHO Series MARKET SECTORS CIVIL, INDUSTRIAL.

EC centrifugal fan. backward curved, single inlet

Yonos PARA RS **/7.0 ipwm1 Datasheet

WATERFLUX 3000 Quick Start

Split case double suction centrifugal pump. Technical data Serie: DPAS C

EC centrifugal fan. backward curved, single inlet

WATERFLUX 3000 Quick Start

UPA 150C. 50 Hz. Applications. Submersible Borehole Pumps for Well Diameters of 150 mm (6 inches) Operating Data. Design. Designation (Example)

APPLICATIONS. Commercial central heating in housing, office buildings, greenhouses, swimming pools, farms, etc. Air conditioning.

GI/EMME SERIES

EC centrifugal fan. backward curved, single inlet

Limit switch set BOA-H DN PN 16/25 Material variant EN-GJS LT

Coriolis Massflowmeter

EC centrifugal fan - RadiCal

RS /M MZ SERIES

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Flush pressure transmitter For viscous and solids-containing media Model S-11

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Submittal Data Sheet Wilo MVI - Vertical Multistage Pumps

OPTIFLUX 5000 Technical Datasheet

SONOMETER TM 1100 Ultrasonic compact energy meter

Coriolis Massflowmeter

Brunata Optuna H. Properties. Counter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

RS /E-EV BLU SERIES

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

OPTIFLUX 5000 Technical Datasheet

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

EC centrifugal fan G1G170-AB backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

SonoMeter 31 Energy Meters

RS /E-EV BLU SERIES

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

EC centrifugal fan. forward curved, dual inlet with housing (flange)

Specification For Approval

LSA R & LSA H 49.1 Low Voltage Alternators - 4 pole

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Technical Data Sheets

SONOMETER TM 1100 Ultrasonic compact energy meter

Submersible pressure sensor For water and wastewater Model LW-1

CONTROL Room. Room product for Swegon s WISE system for demand-controlled ventilation. Quick facts Room control against temperature, CO 2

Side. Channel Blower APEX DARGANG MACHINERY CORPORATION

TPHK Series. Immersible Pump

Resistance thermometer Model TR30, compact design

CI/SfB (57.7) 1st Edition

EC centrifugal fan - RadiCal

Submersible pressure sensor For oils and fuels Model LF-1

RS /E-EV BLU SERIES

Flow Measurement SITRANS F US Inline

ph or ORP Transmitter

Self contained servo drive CLDP Technical data sheet

Control solutions Biofloor

TPHK Series. Immersible Pump

Instruction manual for STA 1 sectional door operator

Online data sheet DFS60B-S4PA00S74 DFS60 INCREMENTAL ENCODERS

EC centrifugal fan - RadiCal

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Online data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS

Miniature resistance thermometer Model TR33, thread-mounted

EC centrifugal fan G3G250-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Heat meter Q heat 5 US

TMU. Coriolis Mass Flow Meter. for liquids and gas

SONO 1500 CT Ultrasonic flow sensor

EC centrifugal fan - RadiCal

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Type overview. Technical data

mass flowmeter for compressed air

Rotary actuators for ball valves

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

EW447-EW452 Series Mechanical Heatmeters FOR HEATING AND COOLING APPLICATIONS

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

EC centrifugal fan G3G200-GN backward curved, single inlet with housing (flange), Gas blower for gas-condensing heating.

Flow Measurement SITRANS F US Inline

Specification For Approval

Field indicator for current loops with HART communication Models DIH50, DIH52

Instruction manual for STA 1 sectional door operator

Specification For Approval

[ ] kvs theor.: Theoretical kvs value for pressure drop calculation Vmax low-n: Vmax for low-noise operation

Digital indicator for panel mounting With multi-function input Model DI25

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

THYRO-P TM THYRO-P TM VSC. Digital thyristor power controller (SCR) NEW

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Pressure transmitter for general industrial applications Model A-10

4/3 proportional directional valve direct operated, with integrated electronics

ECM HIGH EFFICIENCY CIRCULATORS

Electronically controlled proportional pressure regulating valves

Transcription:

High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet

Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a third party without the manufacturer's express written consent. Subject to technical modification without prior notice. KSB Aktiengesellschaft, Frankenthal 14.09.2016

Contents Contents Building Services: Heating...4... 4 Rio-Eco N / Rio-Eco Z N... 4 Main applications... 4 Fluids handled... 4 Operating data... 4 Designation... 4 Design details... 4 Materials... 5 Product benefits... 5 Certifications... 5 FluidFuture energy efficiency concept developed by KSB... 5 Selection information... 6 Programme overview / selection tables... 8 Technical data... 8 Characteristic curves... 9 Dimensions... 10 Flange design... 11 Installation information... 11 Scope of supply... 11 Accessories... 12 3

Building Services: Heating Rio-Eco N / Rio-Eco Z N Characteristic Value Operating p [bar] 10 pressure Sound pressure level [db (A)] Rio-Eco N < 50 Connection Flange: DN 80 Designation Example: Rio-Eco Z N 80-120 Designation key Code Description Rio Type series Eco High-efficiency pump Z Twin pump N Single pump 80 Nominal diameter of pipe connection 80 = DN 80 120 Head in m x 10 (example: 120 = 12 m) Main applications Heating, ventilation, air-conditioning, cooling and circulation systems One-pipe and two-pipe systems Underfloor heating systems Boiler or primary circuits Storage tank circuits Solar power systems Heat pumps Fluids handled Heating water to VDI 2035 Higher-viscosity fluids (e.g. water/glycol mixture up to mixing ratio of 1:1) Pure, thin, non-aggressive and non-explosive fluids not containing any mineral oil, solids or long fibres Fluids with a viscosity of max. 10 mm 2 /s Operating data Operating properties Characteristic Value Flow rate Q [m 3 /h] Rio-Eco N 65 Rio-Eco Z N 55 Q [l/s] Rio-Eco N 18 Rio-Eco Z N 15,3 Head H [m] 12 Fluid T [ C] -10 to +110 temperature Ambient temperature T [ C] 40 Design details Design Highly efficient, maintenance-free wet rotor pump (glandless) Flange connection Continuously variable differential pressure control Operating modes Automatic mode with variable differential pressure Open-loop control mode with external 0-10 V setpoint signal for speed Open-loop control mode with manual setpoint input Automatic functions Continuous output adjustment depending on the operating mode Deblocking function Soft start (slow start) Full motor protection Manual functions Setting the operating mode Setting the differential pressure setpoint Setting the speed level External control functions Control input "start/stop" Control input for remote speed adjustment 0-10 V Signalling and display functions General fault indication (volt-free changeover contact) Fault indication, display of error codes Interfaces Serial digital Modbus RTU interface for connecting higherlevel automation systems via the RS485 system bus Twin pump management Duty/stand-by mode with timer-controlled pump changeover every 24 hours and automatic changeover in the event of a fault 4 Rio-Eco N / Rio-Eco Z N

Building Services: Heating Drive High-efficiency electric motor with continuously variable differential pressure control Integrated motor protection 230 V - 50 Hz IP42 enclosure Thermal class F Temperature class TF 110 Variable speed electric drives to EN 61800-3 EMC requirements Interference emission standard EN 55014-1 or EN 61000-6-3 Interference immunity standard EN 55014-2 or EN 61000-6-2 Bearings Product-lubricated special plain bearing Materials Overview of available materials Component Volute casing Shaft Impeller Bearings Material Grey cast iron (EN-GJL-200) Stainless steel 1.4034 Grey cast iron (EN-GJL-150) Ceramics/carbon (metalimpregnated) Stainless steel 1.4301 Can Product benefits Maximum savings of operating costs by high-efficiency motor combined with speed control "All-in" concept saves costs Design principle ensures long service life and high level of comfort Universal use reduces storage costs High operating availability due to dual pump operation Certifications Overview Label Effective in: Europe Comment EEI 0.23 Germany All sizes FluidFuture energy efficiency concept developed by KSB http://www.ksb.com/fluidfuture Rio-Eco N / Rio-Eco Z N 5

Selection information Minimum pressure The minimum pressure p min at the pump suction nozzle serves to avoid cavitation noises at an ambient temperature of +40 C and the indicated fluid temperature T max. The indicated values are applicable up to 300 m above sea level. For installation at altitudes > 300 m, an allowance of 0.01 bar / 100 m must be added. Minimum pressure p min [bar] specified for the fluid temperature [ C] Size Fluid temperature Minimum pressure [ C] [bar] 80-120 Up to 80 0,8 81 to 95 1,5 Fluid temperature [ C] specified for the ambient temperature [ C] Size Fluid temperature Ambient temperature [ C] [ C] 80-120 90 30 70 40 6 Rio-Eco N / Rio-Eco Z N

Description of the characteristic curve 4,0 H [m] 3,5 3,0 2,5 2,0 1,5 3 4 a) 2 b). A 1,0 0,5 0 c) 1 0 0,5 1 Q [m 3 /h] 1,5 2 2,5 3 30 P 1 [W] 25 20 15 10 a) 4 3 b) c) 2 5 1 0 0 0,5 1 Q [m 3 /h] 1,5 2 2,5 3 Selection example The characteristic curve can be continuously adjusted between a) and c) by turning the control knob. 1 Level 1 = open-loop control n = constant 2 Level 2 = open-loop control n = constant 3 Level 3 = open-loop control n = constant 4 Level 4 = open-loop control n constant A Point of maximum pump power output (Q x H = P max. ) Control range a) Control curve, maximum head b) Characteristic curve for maximum pump power output (factory setting) c) Control curve, minimum head Description of the Modbus interface Description see operating manual of the pump. Rio-Eco N / Rio-Eco Z N 7

Programme overview / selection tables Features and functions Features and functions Functions Operating modes Δp-v for variable differential pressure Fixed speed operation Manual functions Setting the operating mode Setting the differential pressure setpoint Setting the speed level (open-loop control) Vent plug Automatic functions Continuous output adjustment depending on the operating mode (Δp control) Deblocking function Slow start External control functions Integrated control input for remote setting of speed 0-10 V Integrated "start/stop" control input Signalling functions and display functions Display of error codes General fault message (volt-free NC contact) Fault indicator lamp Data exchange Integrated serial digital Modbus RTU interface for connection to a building management system via RS485 bus system Dual-pump management Duty/stand-by mode (automatic changeover in the event of a fault, timer-controlled pump changeover) Features / scope of supply Sealing elements for connection (not fitted) Installation/operating manual Technical data Rio-Eco N selection table Size DN PN P 1 [W] Signalling contacts Nominal current Mat. No. [kg] 1~230 V [A] 80-120 DN 80 6 150-1400 SSM 1,3-9,0 29134172 38.5 80-120 DN 80 10 150-1400 SSM 1,3-9,0 29134173 38.5 Rio-Eco Z N selection table Size DN PN P 1 [W] Signalling contacts Nominal current Mat. No. [kg] 1~230 V [A] 80-120 DN 80 6 160-1350 SSM 1,35-9,40 29134716 87.4 80-120 DN 80 10 160-1350 SSM 1,35-9,40 29134182 70 SSM = General fault message 8 Rio-Eco N / Rio-Eco Z N

Characteristic curves Rio-Eco N 80-120 12 10 H [m] 8 1~230 VAC DN 80 6 4 2 0 0 10 20 30 40 50 60 70 Q [m 3 /h] 1.600 1.400 P 1 [W] 1.200 1.000 800 600 400 200 0 0 10 20 30 40 50 60 70 Q [m 3 /h] Rio-Eco Z N 80-120 12 H [m] 10 1~230 VAC DN 80 8 6 4 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Q [m 3 /h] 1.600 1.400 P 1 [W] 1.200 1.000 800 600 400 200 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Q [m 3 /h] Rio-Eco N / Rio-Eco Z N 9

Dimensions Pump dimensions a b c d e H Flanged pump Rio-Eco N dimensions [mm] Size DN a b c d e H 80-120 80 240 100 105 170 170 360 Twin pump dimensions a b f g e d h c Flanged pumps Rio-Eco Z N dimensions [mm] Size DN a b c d e f g h 80-120 80 513 275 245 360 160 205 240 175 10 Rio-Eco N / Rio-Eco Z N

Flange design Ø D Ø k Ø d DN n x Ø d L Flange Dimensions [mm] Flange ØD Ød PN 6 PN 10 PN 6 PN 10 Øk Øk n d2 n d2 DN 80 200 132 150-4 Ø14 - DN 80 200 132-160 - 8 Ø19 Installation information Permissible installation positions Sizes Rio-Eco N Rio-Eco Z N Scope of supply Pump Installation/operating manual Rio-Eco N / Rio-Eco Z N 11

Accessories Electrical accessories Description Cable length Mat. No. [kg] BACnet IP communication module Suitable for mounting in a control cabinet, with 100 data points for connecting several Rio-Eco N/Rio-Eco Z N pumps [m] 01550857 0.995 Modbus data cable 5 19075536 0.2 Pre-configured plug for Rio-Eco N Data cable 1 19075537 0.1 For connecting two single Rio-Eco N pumps for dual pump operation, pre-configured with plug 1) Communication module 01550860 1 Suitable for wall mounting, for connecting up to 6 Rio-Eco N/Rio- Eco Z N pumps, for signalling an "in operation" or alarm message (general fault message) Cold water insulation Description For size Mat. No. [kg] Diffusion-tight insulation for cooling applications for Rio-Eco N pumps 80-120 PN 6/10 19075545 0.1 Spacers Description Mating PN Length Mat. No. [kg] flange Spacer F8 DN 80 6/10 10 mm 19075574 2 Spacer F9 DN 80 6/10 15 mm 19075575 2 Spacer F10 DN 80 6/10 20 mm 19075576 2 Spacer F11 DN 80 6/10 25 mm 19075577 2 Spacer F12 DN 80 6/10 30 mm 19075578 2 Spacer F13 DN 80 6/10 40 mm 19075579 2 Spacer F14 DN 80 6/10 40 mm 19075580 2 Spacer F15 DN 80 6/10 80 mm 19075581 2 1) Included in the scope of supply of Rio-Eco Z N 12 Rio-Eco N / Rio-Eco Z N

KSB Aktiengesellschaft 67225 Frankenthal Johann-Klein-Str. 9 67227 Frankenthal (Germany) Tel. +49 6233 86-0 Fax +49 6233 86-3401 www.ksb.com 1140.51/03-EN 14.09.2016