The oscilloscope and RC filters

Similar documents
Brock University Physics Department St. Catharines, Ontario, Canada L2S 3A1. Phys 2P31: Electronics I Laboratory Manual. E. Sternin and P.

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Introduction to basic laboratory instruments

Laboratory 3 (drawn from lab text by Alciatore)

PHY152 Experiment 4: Oscillations in the RC-Circuits (Measurements with an oscilloscope)

Laboratory Exercise 6 THE OSCILLOSCOPE

Week 7: Design a Logarithmic Voltmeter. A variation on Experiment 19 Validation by 8pm on October 14

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

2 Oscilloscope Familiarization

LAB I. INTRODUCTION TO LAB EQUIPMENT

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

EXPERIMENT NUMBER 2 BASIC OSCILLOSCOPE OPERATIONS

EENG-201 Experiment # 4: Function Generator, Oscilloscope

EE EXPERIMENT 1 (2 DAYS) BASIC OSCILLOSCOPE OPERATIONS INTRODUCTION DAY 1

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

Lab #1 Lab Introduction

UNIVERSITY OF CALIFORNIA, SANTA BARBARA Department of Electrical and Computer Engineering. ECE 2A & 2B Laboratory Equipment Information

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

EE 368 Electronics Lab. Experiment 10 Operational Amplifier Applications (2)

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Notes on Experiment #1

LAB II. INTRODUCTION TO LAB EQUIPMENT

Lab 6 Instrument Familiarization

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

Agilent 33522A Function Arbitrary Waveform Generator. Tektronix TDS 3012B Oscilloscope

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Name: First-Order Response: RC Networks Objective: To gain experience with first-order response of RC circuits

Oscilloscope and Function Generators

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

Ph 3455 The Franck-Hertz Experiment

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

EC310 Security Exercise 20

LAB I. INTRODUCTION TO LAB EQUIPMENT

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Faculty of Engineering, Thammasat University

Electrical Engineering Laboratory Equipment Instructional Videos

Lab 0: Introduction to basic laboratory instruments. Revised by Dan Hoang & Tai-Chang Chen 03/30/2009

ENGR 210 Lab 6 Use of the Function Generator & Oscilloscope

Equipment and materials to be checked out from stockroom: ECE 2210 kit, optional, if available. Analog BK precision multimeter or similar.

Sonoma State University Department of Engineering Science Spring 2017

EXPERIMENT 2 DIGITAL STORAGE OSCILLOSCOPE

ENGR 1110: Introduction to Engineering Lab 7 Pulse Width Modulation (PWM)

ECE 2274 Lab 1 (Intro)

2 AC and RMS. To pass this lab you must solve tasks 1-2. Tasks 3 and 4 are included in the grading of the course.

Laboratory Equipment Instruction Manual 2011

Analog Discovery Arbitrary Function Generator for Windows 7 by Mr. David Fritz and Ms. Ellen Robertson

ECE 53A: Fundamentals of Electrical Engineering I

Oscilloscope. 1 Introduction

DC and AC Circuits. Objective. Theory. 1. Direct Current (DC) R-C Circuit

University of Utah Electrical & Computer Engineering Department ECE 2210/2200 Lab 4 Oscilloscope

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

LAB 1: Familiarity with Laboratory Equipment (_/10)

Class #8: Experiment Diodes Part I

Experiment 1.A. Working with Lab Equipment. ECEN 2270 Electronics Design Laboratory 1

Time-Varying Signals

Sept 13 Pre-lab due Sept 12; Lab memo due Sept 19 at the START of lab time, 1:10pm

EECS 318 Electronics Lab Laboratory #2 Electronic Test Equipment

Experiment 13: LR Circuit

Physics 120 Lab 1 (2018) - Instruments and DC Circuits

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

Sampling and Reconstruction

ET1210: Module 5 Inductance and Resonance

CHAPTER 6. Motor Driver

EE2210 Laboratory Project 1 Fall 2013 Function Generator and Oscilloscope

EC-3: Capacitors and RC-Decay

Getting started with Mobile Studio.

Waveform Generators and Oscilloscopes. Lab 6

Oscilloscope Operation. Visualizing Signals and Making Measurements

332:223 Principles of Electrical Engineering I Laboratory Experiment #2 Title: Function Generators and Oscilloscopes Suggested Equipment:

Group: Names: (1) In this step you will examine the effects of AC coupling of an oscilloscope.

Introduction to oscilloscope. and time dependent circuits

LAB 7: THE OSCILLOSCOPE

Introduction to basic laboratory instruments

Introduction to Basic Laboratory Instruments

Lab E5: Filters and Complex Impedance

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

EXPERIMENT 1 PRELIMINARY MATERIAL

EE 210: CIRCUITS AND DEVICES

MASSACHUSETTS INSTITUTE OF TECHNOLOGY /6.071 Introduction to Electronics, Signals and Measurement Spring 2006

Physics 323. Experiment # 1 - Oscilloscope and Breadboard

INTRODUCTION TO ENGINEERING AND LABORATORY EXPERIENCE Spring, 2015

Lab #11 Rapid Relaxation Part I... RC and RL Circuits

Experiment 1: Instrument Familiarization (8/28/06)

Virtual Lab 1: Introduction to Instrumentation

ECE 480: SENIOR DESIGN LABORATORY

LABORATORY 3: Transient circuits, RC, RL step responses, 2 nd Order Circuits

CPE 100L DIGITAL LOGIC DESIGN I DESIGN LABORATORY LABORATORY 1 LAB SAFETY QUIZ & LAB EQUIPMENT USE TUTORIAL UNIVERSITY OF NEVADA, LAS VEGAS GOALS:

EE 3302 LAB 1 EQIUPMENT ORIENTATION

Exponential Waveforms

University of Jordan School of Engineering Electrical Engineering Department. EE 204 Electrical Engineering Lab

Experiment 1: Instrument Familiarization

A semester of Experiments for ECE 225

USE OF BASIC ELECTRONIC MEASURING INSTRUMENTS Part II, & ANALYSIS OF MEASUREMENT ERROR 1

CPE 310L EMBEDDED SYSTEM DESIGN LABORATORY

Sound Wave Measurements using an Oscilloscope and Waveform Generator

resistor box inductor 3 BNC to banana + V L

Equipment: You will use the bench power supply, function generator and oscilloscope.

LAB #7: Digital Signal Processing

Transcription:

(ta initials) first name (print) last name (print) brock id (ab17cd) (lab date) Experiment 4 The oscilloscope and C filters The objective of this experiment is to familiarize the student with the workstation equipment to be used throughout the course. Some simple experiments/measurements will be conducted to facilitate the practical use of this equipment. 4.1 Workstation equipment Digital oscilloscope An oscilloscope displays on a two-dimensional grid the variation in voltage (y) with time (x) of one or more input signals. A digital scope includes a lot of features intended to make the measurement and analysis of these signals easy. The basic controls are grouped into the following functional blocks: 1. the VETICAL controls set the voltage gain and input coupling for each channel. Select a channel by pressing the CH1 or CH2 keys, then use the VOLTS/DIV knob to adjust the vertical resolution, or gain, of the waveform. The voltage gain per grid division is shown on the bottom of the display. You can use the grid to make approximate measurements or preferably, use the framing cursors. Press the CUSO button, followed by the X-Y button to display two horizontal cursors in the same colour as the selected channel. Select a cursor Y1 or Y2 and position it with the VAIABLE knob; their values and difference Y1Y2 are shown to the right. By default, the display gain occurs about the ground level (V=0) of the signal. You can zoom in on any part of the waveform by setting the Expand menu selection to center; the zoom then occurs about the vertical center of the display. As you change the gain setting, you will likely need to re-center the region of interest using the vertical position knob. The coupling selection allows the input channel to be grounded (displaying a flat line at V=0), to view the input signal as it is (DC) or view it with the DC component removed (AC). The AC setting can be used to focus on a small varying signal when it is offset by a larger DC voltage. The MATH button provides ways to add, subtract, and multiply together the instantaneous voltages af the two channels. A Fast Fourier Transform (FFT) can also be applied to an input signal. In this mode, the signal x-axis is calibrated in units of frequency (Hz) rather than time (s) and the scope displays the amplitude-frequency relationship, or frequency spectrum, of the signal. 2. the HOIZONTAL controls similarly set and adjust the common time scale for the two input channels. Again, you can use the cursors to take measurements. By selecting the XY mode, CH2 (y) is displayed as a function of CH1 (x). This mode is used to measure phase or voltage-current relationaships between two signals; 19

20 EXPEIMENT 4. THE OSCILLOSCOPE AND C FILTES 3. the TIGGE controls set the starting position (level) and direction (slope) of a signal relative to the centre of the display x-axis. The trigger source can be either CH1, CH2, the 60Hz Line input to the scope, or some External input connected to the EXT TIG connector. The voltage level is set with the LEVEL knob and is monitored by an arrow on the right edge of the display. The trigger slope can be set to (positive) or (negative). The trigger coupling functions as outlined above. The SINGLE capture mode causes the scope to wait for and record a single screen and then stop; this is useful when monitoring non-periodic events. As with all things, familiarity comes with practice. Try out the various settings, some functions you will use all the time, others rarely. If the signal disappears, press the Autoset button. To restore the default settings, turn the scope off and then back on. Digital multimeter Use this instrument to precisely measure the basic electrical quantities such as DC and AC voltage and current, and resistance. In the AC domain, the peak, average, and MS values of a signal can bemeasured. Waveform generator A waveform (or function) generator is used to provide a precise, adjustable signal to an electronic circuit. Typical waveforms include sine, triangle, ramp and square/pulse. These various signals vary in harmonic content, from the pure sinusiod to the others that contain various mixtures of sinusoidal overtones. The rapid transition of the pulse waveform can be used clock digital circuits or to excite analog circuits into a state of self-oscillation. Basic controls allow the adjustment of amplitude, frequency, pulse width, and the application of a DC offset voltage to the signal that appears at the output BNC connector of the FG. The amplitude and frequency of the signal can also be modulated, or varied in some way. A typical modulation used for testing the response of electronic circuits is a frequency sweep. The Sync BNC connector provides a 0-5V square wave at the frequency set by the FG. This signal can be used as a clock in digital circuits or to synchronize (phase lock) external devices to the FG signal. Note that some of the function generators have an output switch that enables the FG output; be sure to turn it on otherwise no signal will appear at the output BNC connector. Precision power supply This device approximates an ideal voltage source. The output is regulated so that the voltage will not vary with changes in output current of up to 1A. The output can also be current limited so that a test circuit will not draw excessive amounts of current if defective or if there is a short circuit. The output voltage and current can be monitored and the maximum current can be set. This device provides three voltage outputs adjustable in steps of 0.1mV and 1mA. This voltage resolution allows the power supply to be used as a precision voltage reference. Connecting instruments Always connect external devices such as meters, scopes, and function generators using the banana Figure 4.1: The proper breadboarding technique

4.1. WOKSTATION EQUIPMENT 21 plug (black and red pairs) and BNC (coaxial) connectors near the top of the breadboard workstation. These contact points are available on the breadboard and can be accessed using jumper wires.! Turn on the instruments. Note that for the best measurement accuracy, electronic measuring devices should be given time to warm up and equilibrate to operating temperature, typically around 30 minutes, hence you should power-up your workstation at the start of the lab session. At the end of the lab, power-down all equipment and disconnect from the AC outlets any devices that you may have plugged in.! With appropriate (BNC-terminated) cables, connect the output of the function generator (FG) and then the Channel 1 (CH1) input on the oscilloscope to the workstation. Insert a breadboard into the workstation, then insert a short jumper wire on the breadboard to complete the signal path between FG and scope. Connecting the scope channels CH1 and CH2 to the corresponding BNC1 and BNC2 on the breadboard will make it easier for you to remember the location of the signal connections.! Set the FG to output a sine wave of 1 KHz frequency and 1 V amplitude. On the scope, turn off CH2 by toggling the CH2 button until the blue trace disappears. Turn on CH1 and set the gain to 500 mv/div, the timebase to 500 us/div and the coupling to DC. Be sure that the Voltage is set to 1X; if not, turn the variable knob to make it so.! The zero voltage level of the signal is given by the position of the symbol 1> on the left side of the screen. You can temporarily ground the signal so it collapses to a horizontal line by setting the coupling to ground. otate the knob above the CH1 button to set the trace vertical position at 0 V; the current position appears on the bottom left corner of the display while the knob is being turned.! Press the Trigger, menu button and check that the trigger source is set to CH1, then with the LEVEL knob adjust the trigger level to 0V.! You can capture the current oscilloscope screen by typing GDS-1102A.tcl in the terminal window; this application makes a USB connection to the scope and displays a virtual scope screen that can be saved for inclusion in your report by pressing the Hardcopy button. You can place a shortcut to this application on your desktop by right-clicking the desktop background, then clicking on Create Launcher. Enter a meaningful name and in the command box enter /usr/local/bin/gds-1102a.tcl. If you wish, double-click on Icon to select an icon from those available. Click Create and you are done! Similarly, you can create a shortcut to the Screenshot application by following the same procedure and entering xfce4-screenshooter.? Use the cursors to measure the amplitude and period of the signal. Tabulate all your data. Estimate the measurement errors by determining the cursor step sizes at the current display settings and apply these uncertainities to the measured values.? Vary the gain and timebase of the displayed signal and repeat the above procedure. Note how the choice of scale affects the measurement error. How should you scale the signal in order to minimize the measurement error?? Press the Autoset button to have the scope set the display parameters. Do the settings selected by the scope yield the best resolution for the input signal? Explain.

22 EXPEIMENT 4. THE OSCILLOSCOPE AND C FILTES? Vary the scope trigger level. How does the waveform change? What happens when the trigger level exceeds the range of the signal? Change the trigger slope. What effect does this have on the waveform? Use screen captures to describe the function of these trigger controls. 4.2 Exponential decay in an C circuit Figure 4.2: Time dependence of V C Consider the battery-driven C circuit on the left. Initially, the capacitor is uncharged, so V C = 0. When the switch is first turned to position A, the current I has the initial value: I 0 = V 0 V C As the current brings charge to the capacitor, the voltage V C increases up to its maximum value V C = V 0, at which point the current reduces to zero: = V 0 (4.1) I = V 0 V C = V 0 V 0 To analyze the circuit at intermediate times, we apply KVL: = 0. (4.2) V 0 I V C = 0, (4.3) which for this circuit translates into a differential equation, since V C = 1 I(t )dt. (4.4) C Substituting equation (4.4) into equation (4.3) and differentiating once gives or The solution to this differential equation (4.6) is 1 C I +di dt = 0, (4.5) di dt + 1 I = 0. (4.6) C I = I 0 e t/τ. (4.7)

4.3. MEASUING TANSIENTS IN AN C CICUIT 23 where τ = C is the characteristic time constant, and I 0 is the constant of integration whose value is determined from the initial conditions, as in Equation (4.1). For the voltage across the capacitor, V C = V 0 I = V 0 V 0 e tτ = V 0 (1 e t/τ ) (4.8) If the switch is now turned to position B, the battery is eliminated from the circuit and the capacitor discharges through the resistor. The direction of I is reversed, but it has the same exponential time dependence I = I 0 e t/τ. (4.9) where I 0 = V 0 / as before. Again, the time dependence of V C is also exponential: Equations (4.8) and (4.10) are summarized in Figure 4.2. 4.3 Measuring transients in an C circuit one 10 kω resistor one 0.01 µf capacitor V C = I = V 0 e t/τ (4.10) Additional components required Often, the time constant, τ = C, of the transient is so short that it is impossible to move a mechanical switch, or to measure the voltage using a voltmeter, fast enough to see the exponential decay. Instead, one can use a square-wave output of a function generator (FG) and an oscilloscope, to monitor both V in and V out, as in Figure 4.3. Note that in the above circuit, all the BNC ground connections are already made by the protoboard; only the capacitor needs to be gounded.! Construct the circuit of Figure 4.3 with = 10kΩ and C = 0.01µF, using the proper breadboarding technique. Drive it with a 1 KHz square wave of 5 Vpp (peak-to-peak). Adjust the DC offset voltage on the FG so that the signal toggles between 0 V and 5 V. Obtain a stable trace and record a graph of the voltage as a function of time on both channels of the scope, for one full period of the square wave. Figure 4.3: Transients measurement setup

24 EXPEIMENT 4. THE OSCILLOSCOPE AND C FILTES! Adjust the function generator and gain and timing controls of the oscilloscope as necessary to best measure the exponential fall of the voltage. Determine the time constant of the circuit by using the cursors to select two points on the decay curve that satisfy the voltage change with time equation used in the previous lab. Include error estimates for all your measurements and results. You can jog the cursors to determine the measurement step size and thus the scale error.! Determine the relationship between signal period and C time constant necessary for the output signal to behave as an integrator. Use a series of frequencies starting at 1-KHz and scope screen captures to show how this integrator behaviour emerges.! Interchange C and and repeat the time constant measurement.! Determine the necessary condition to have the circuit acts as a differentiator. Follow the above steps to show how this behaviour emerges.? Discuss your results and compare with theory.