Miniflex. Rigaku/ Miniflex X-ray Diffractometer System. Rigaku Corporation

Similar documents
AutoMATE II. Micro-area X-ray stress measurement system. Highly accurate micro area residual stress

XRC X-Ray Calibration System

-_.-~ Sample. HIGH SENSITIVITY TYPE TOTAL REFLECTION X-RAY SPECTROMETER SYSTEM Wafer Surface Analysis System --

PRECISION CUTTING MICRACUT 202

PSPC/MDG 2000 X-RAY MICRODIFFRACTOMETER. Product Information

RA-Micro 007 Desktop Rotating Anode X-Ray Generator Specifications Manual

Powder diffractometer operation instructions D8 Advance with a Cu Kα sealed tube and Lynxeye MARCH 30, 2016

Rigaku Cr-Source RU300 Rotating Anode X-Ray Generator 185mm Radius Diffractometer

Fluorescence X-ray Spectrometer System ZSX Series

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

LECTURE 10. Dr. Teresa D. Golden University of North Texas Department of Chemistry

R-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information

Basic P-XRD instructions for Operating the Instrument

Who is GBC Scientific Equipment?

Instructions XRD. 1 Choose your setup , Sami Suihkonen. General issues

Standard Instructions for the Bruker D8 Advance Diffractometer, EPFL Valais Bragg Brentano and GID (Reflection)

General Measurement (BB) Part

Lesson 2 Diffractometers

Experiment #12 X-Ray Diffraction Laboratory

Model LS 250 Loop Scanner Operator s Manual. Version

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

GEMSCRIPTOR DT-150-R

X-RAY OPTICS FOR TWO-DIMENSIONAL DIFFRACTION

Minnesota Rules, Chapter 4732 X-ray Revision

(12) Patent Application Publication (10) Pub. No.: US 2007/ A1

By using patented polycapillary optics this diffractometer obviates the need for monochromators and collimators for linear projection of X-Rays.

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

Powder X-Ray Diffraction Alignment Procedure

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

RIGAKU VariMax Dual Part 0 Startup & Shutdown Manual

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

CSNC CARBIDE CIRCULAR SERIES

directly on each side of the crystal to form a rugged, monolithic oscillator that is end pumped by a CW diode laser.

APPENDIX K UNF RADIATION GENERATING DEVICE SAFETY PROCEDURES

DiaInspect-P. Operating manual. Version Page 1

Rigaku Innovative Technologies Europe (RITE) Presented by: Dr.Peter Oberta

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )

METALLOGRAPHY EQUIPMENT

LUDLUM MODEL MODEL AND MODEL GAMMA SCINTILLATORS. June 2017

Using the Open Eularian Cradle (OEC)

Cartogam Real-Time Portable Gamma-Ray Imaging System

Residual Stress Measurement Part

Title: Amray 1830 SEM#2 Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 03/18/2016

Operating Manual. Model 721N. Visible Spectrophotometer

RADIATION SAFETY REQUIREMENTS FOR ANALYTICAL X-RAY EQUIPMENT

SUPPORTING INFORMATION

SOP for Hitachi S-2150 Scanning Electron Microscope For review purposes only

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

Features. Applications. Optional Features

2. Raise HT to 200kVby following the procedure explained in 1.6.

ABRASIVE CUTTING METACUT 302

Model WHD Weld Hole Detector Operator s Manual. Rev 1.1

XRP Generators. Overview. Industrial X-Ray. Technology with Passion

CHAPTER 3 BASIC OPERATING METHODS OF PHOTOMULTIPLIER TUBES

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

RadView Manual Collimator

Introduction of New Products

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

Keene State College Center for Environmental BioGeoChemistry Radiation Protection Program Revised January

RIGAKU D/MAX-B AND MICRO-PROCESSOR

DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE

GE AMX 4+ Portable X-Ray

SAMPLE PREPARATION SPECTRAL MMAX. metkon.com

ADAE portable X ray machine Operation manual

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

SPECTRAL SCANNER. Recycling

OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

SPECIFICATIONS TO : DUST SENSOR MODULE P/N : DSM501 DSM501 DUST SENSOR MODULE =======================================

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Model OB-ITF Infrared Through-Beam Fiber Optic Optical Barrier Operator s Manual. Version

05/20/14 1. Philips CM200T. Standby Condition

Integrated calibration system for electronic and pneumatic instrumentation model CBS-SC2000

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

SIMULTANEOUS XRD/XRF WITH LOW-POWER X-RAY TUBES

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

7-4-2 (4) Set up mode (Play fee, BGM, Tilt sensor)

TW-400HV Combination Universal Horizontal / Vertical Machining Center

Z500. High-Precision Sensor that Measures and Displays an Object's Profile. Profile Measuring System

INTRODUCTION We believe that every laboratory working in the field of nanotechnology needs an SEM, therefore we would like to introduce to you our IEM

Contents I. APPLICATIONS II. SPECIFICATIONS III. PRINCIPLES IV OPERATION V. MAINTENANCE

MCV-300 VERTICAL MACHINING CENTER LONG CHANG MACHINERY CO., LTD.

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

Brandt Automatic Edgebander Optimat Model KDF 670 2C

PICO MASTER 200. UV direct laser writer for maskless lithography

Rotating Anode X-Ray Tube Housing Assembly. General Data

Supplementary Figure 1

HITEK POWER OL600W SERIES

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

This series of lasers are available with a choice of Nd:YAG, Nd:YLF, and Nd:YVO 4. System Reliability

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Transcription:

Miniflex Rigaku/ Miniflex X-ray Diffractometer System Rigaku Corporation

Rigaku/ Miniflex X-ray Diffractometer System 1. Introduction Rigaku s general purpose X-ray diffractometer systems are broadly classified into two series; the D/MAX series and the Miniflex series. The D/MAX series is a research grade tool which meets a wide range of X-ray analysis needs and can be configured with a variety of diffraction attachments and cameras. According to diversified measurement purposes, attachments allow multiple axis rotation, mapping, stress loading, heating and cooling, and so on. The Miniflex series is designed to be functionally simple while maintaining precision measurement capability comparable to the D/MAX series. It is ideally suited for teaching in the college /university environment and quality control and inspection in production. As examples, the Miniflex is widely used to control composition and mixture ratios as well as for quantitative measurement of environmentally hazardous materials. In these applications, the operational procedures are routine, the sample materials and the measuring conditions remain similar. The Miniflex is the smallest, lightest weight diffractometer in the world. It fits easily on a desktop and simply plugs into the wall. It is rugged enough to load into a vehicle and be transported and used in the field. This capability is ideal for using at geological sites, quarries, or for sorting concrete skeleton materials. 2. Features (1) Radiation Enclosure & Safety When the radiation enclosure door is opened, the X-ray shutter will automatically close. This function completely protects the user from exposure. (2) Display of Instrument Status Instrument status is available on demand to monitor the functions of the

components. (3) Continuously Variable Slit The continuously variable slit (patent pending) is linked to the becomes larger. This will improve the peak-to background ratio at low 2 angles as well as increase the X-ray intensity at high angles. These improvement are important for the measurement of clay minerals, concrete skeleton materials, etc. (4) Automatic Sample Changer with 8 Positions Up to 6 samples can be mounted and measurement with the automatic sample changer. Each sample can be made to spin to enhance data precision for qualitative and quantitative analysis. The changer option is helpful for routine sample analysis of geological samples, asbestos dust, row material consistency, etc. (5) Sample Holders Two(2) types of holders, for powder and bulk samples, are available for use with the Miniflex s vertical goniometer. (6) Standard Measurement Software The software is written in Windows for the PC, has multiple functions, and is easy to use. Measurement condition parameters include the following: Sample Name (ID) Scan rang in degrees 2 Measurement mode (continuous scan, step scan, or skip scan) Sampling width in degrees per step Scanning speed (7) Qualitative Analysis Software Identification of phases is achieved through accessing the ICDD databases. This is accomplished through the primary search/march to ICDD card information, a secondary search/march which compares the d-spacings and intensities with the measured data, and a residual search/march which is performed after excluding the major components. 3. Configuration 3.1 Standard Configuration (1) Goniometer (2) Tube shield (3) Detector (4) X-ray generator (5) Electronic circuit panel (6) X-ray proof console (7) Flow rate detection system (8) X-ray tube (9) Personal computer (10) Standard measurement software

3.2 Options (1) Air cooling system heat exchanger (2) Specimen rotation attachment (3) Auto sample changer (4) Autotransformer (5) Optional software 1) Multiple recording software 2) Qualitative analysis software 3) Simplified qualitative analysis (concrete skeleton material, qualitative analysis, compositive ratio, etc.) 4) ICDD database control 5) Database software for ICDD qualitative analysis 6) Environmental particle dust quantitation (asbestos particle dust) software 4. Specifications 4.1 Goniometer An automatic variable divergence slit (patent pending) is standard on the system. The slit width increases as angles increases, keeping the irradiated area on the sample constant. The goniometer is a high precision design which operates by maintaining a 2 to 1 ratio of the 2 and the axes. (1) Type : Vertical type (2) Goniometer radius : 150mm (3) Scanning axis : /2 coupled (4) 2 angle measurement range : ~ -3 +150 (5) Slew speed : 1000 /min(2 ) (6) Scanning speed : 0.01 ~ 100 /min (keyboard input) (7) Datum angle : 2 /10 (8) Slit DS : Variable slit interlocked with axis, max.2.8 SS : 2.8 fixed RS : 0.3mm fixed Soller slit : 2.5 (9) Setting precision : 2 +0.05 (10) Setting angle reproducibility : 2 +0.01 (11) X-ray take-off angle : 6 fixed 4.2 Tube Shield Contains shutter mechanism, X-ray tube, and high voltage connection. (1) Applicable X-ray tube : Toshiba A-41, Philips PW22XX, etc. (2) Focus position adjuster : +1 plate spring system, continuously variable(patent pending) (3) X-ray shutter : Mechanical rotary shutter interlocked with open/close door of X-ray proof console (4) Filter for K removal : Ni filter (for Cu-target X-ray tube. Other

are optional.) 4.3 Detector SC-M Incident X-ray are diffracted by the sample. The resultant photons are illuminated on a scintillation crystal and are converted to electrical signals by a photomultiplier tube specifically developed for the Miniflex. The SC-M is an exceedingly small-sized scintillation counter. (1) Scintillator : NaI (Ta) (2) Window material : Be (3) Outer dimensions : 24mm dia. x 45mm long 4.4 X-ray Generator The 450W high frequency generator is a highly stable source. (1) Tube voltage output : 30kV (fixed) (2) Tube current output : 15mA (fixed) (3) high voltage generation : High-frequency Cockcroft-Walton system (4) 7-hour continuous stability : Within +0.05% for both tube voltage and tube current as against +10% input power variations (5) Safety circuit 1) Error lights and audio alarms are tripped when there is an overload of voltage or current and/or insufficient water flow. At the time of the failure, the high voltage will shut down. 2) X-ray generation, shutter open/close display lamp 3) Emergency push-button switch 4.5 Electronic Circuit Panel The electronic circuit panel (ECP) controls the 2 / stepping motor, the DC high voltage power supply for the detector, the PHA discriminator, and scaler. The ECP also displays the operating status of each component. (1) / 2 axis minimum step angle : 0.005 /pulse ) (2 (2) H.V. power supply for counter : 0 ~ 1000V + 0.02% (3) Pulse height discrimination circuit : Fixed pulse height system (4) Scaler : 24-bit counter (5) Maintenance display function : 1) SCAN : Stays on while the detector keeps on scanning in order during goniometer motor run. 2) HV : Stays on while high voltage is applied to the detector. 3) PHA : Stays on while counting is made as X-ray are being detected by the detector. 4) HVL : Lights up instantly when the tube voltage exceeds 31.5KV to turn off X-ray along with buzzer alarm. 5) LVL : Lights up instantly when the tube voltage falls below 28.5KV to turn

off X-ray along with buzzer alarm 6) HTC : Lights up instantly when the tube current exceeds 16mA to turn off X-ray along with buzzer alarm 7) LTC : Lights up instantly when the tube voltage falls below 14mA to turn off X-ray along with buzzer alarm 8) HFC : Lights up instantly when the filament current for the X-ray tube flows in excess of 150 percent to turn off X-ray along with buzzer alarm 9) LFC : Lights up instantly when the filament current for the X-ray tube falls below 50 percent to turn off X-ray along with buzzer alarm 10) CW : Lights up when the cooling water flow rate becomes less than 1.8lit/min to turn off X-ray along with buzzer alarm 11) X-RAY : Stays on during X-ray generation. 12) SHUTTER :Stays on while the X-ray shutter is open for irradiation. 13) READY : Lights when all is set for X-ray generation, with power on, a sufficient cooling water flow rate, and fully closed console door. 4.6 Water cooling unit Cooling water to dissipate the heat form the X-ray tube can be provided from an in house supply, or where unavailable, from a dedicated portable air cooled, recirculating heat exchanger. (1) Flow meter : For detection of a 1.8 lit/min or less flow rate on the drain side. (2) Hose : 10mm dia. I.D., 16mm dia. O.D., 5 meters each (TETRON braided), with two hose bands 4.7 X-ray Tube The system requires a vacuum sealed X-ray tube of various target materials. Precision alignment of the optical system is performed at the factory prior to shipment. (1) X-ray tube : Toshiba Cu (standard) 1 set (2)Max. output : 1KW (3) Focus size : 1 x 10mm 4.8 Computer This computer controls the goniometer / 2 axis via the ectronic el circuit panel. It also performs data storage, various corrections, computing analysis, display and output. 4.9 Standard Measurement Software (1) System environment parameters (2) Manual measurement (3) Standard measurement (4) Integrated intensity calculation (5) Peak search

4.10 Options (1) air cooling system recirculation water feed pump (heat exchanger) (2) Specimen rotation attachment (3) Auto sample changer (4) Optional software 1) Multiple recording software 2) Qualitative analysis software 3) Civil engineering material analysis (concrete skeleton material analysis) 4) ICDD database management 5) ICDD database 6) Environmental particles dust quantitative analysis (asbestos quantitative analysis) 5. Installation Requirements 5.1 Dimensions and Weight (1) Basic console unit : 560mmW x 315mmD x 582mmH., 59kg (2) Air cooling system : 333mmW x 540mmD x 425mmH., 21kg Heat exchanger 5.2 Installation Requirements (1) Floor strength : No vibrations sensible to the human body. (2) Temperature : 10 ~ 30 (3) Relative Humidity :40% ~ 70% (no condensation) (4) Magnetic field : Nothing must be nearby which will generate a magnetic filed that affects the computer s CRT image. 5.3 Power Capacity The power supply of the following capacity and rating should be used for the Miniflex. The total capacity may vary depending on combined units. Single phase AC: 115V,15A Earth-grounded receptacle (3P) 3 pieces 5.4 Power Supply Quality (1) Frequency stability : 59Hz+1% (2) Voltage stability : 100V+10% (3) For the single phase, one wire must be ground. (4) No such device as will cause surge and noise must be connected to the same wiring system. 5.5 Grounding (1) Grounding resistance : 100 or less