Existing and Emerging Opportunities in Printed Electronics For Printers

Similar documents
EXPERIMENT 8 Bio-Electric Measurements

Henkel solutions enabling printed electronics. Dr. Crystal Yang

V Technical Textiles Interconnect PRESENTED BY V TECHNICAL TEXTILES, INC.

instead we hook it up to a potential difference of 60 V? instead we hook it up to a potential difference of 240 V?

Issue 2 March Electroluminescent Materials

EXPERIMENT 5 Bioelectric Measurements

SCREEN PRINTING ELECTRONICS

UV TECHNOLOGY. Relatively new, but rapidly emerging technology. AZON Q UV PRODUCT CATALOG

Lab: Using filters to build an electrocardiograph (ECG or EKG)

Lab E5: Filters and Complex Impedance

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD

Processes for Flexible Electronic Systems

Name Kyla Jackson, Todd Germeroth, Jake Spooler Date May 5, 2010 Lab 3E Group 3 Experiment Title Project Deliverable 3

PRINTED ELECTRONICS 3

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Sample Specification Electrical Heat Tracing Cables Metric Units

SPECIFICATION FOR APPROVAL. 1/32W, Low Resistance Chip Resistor (Lead / Halogen free)

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Wireless Sensor Networks. EP2980

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

(FL) Current Shunts Resistors

Designing with Glass. Privacy & Translucency

PRINTED ELECTRONICS TECHNOLOGIES

Figure 1 - IMSE (courtesy of TaktoTek)

Avery Dennison Instructional Bulletin 4.14 Printing and Finishing of Digitally Produced Graphics

Electrocardiogram (ECG)

Application Note. Customized Glucometer using GreenPAK AN-CM-222

Auto Diagnosis Test #2 Review

Used to overcome ventricular fibrillation may be due to coronary occlusion, shock, or abnormalities in blood chemistry

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

Kingbright. L-7679C1SYC-H Super Flux LED Lamp DESCRIPTIONS PACKAGE DIMENSIONS

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

Senior Science. Total marks 100

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

How an ink jet printer works

1.5SMCxxAT3G. TVS Diodes. Surface Mount > 1500W > 1.5SMCxxAT3G. Cathode. Anode. Uni-directional. Description

Biomedical Electrodes, Sensors, and Transducers. Definition of Biomedical Electrodes, Sensors, and Transducers. Electrode: Sensor: Transducer:

SPECIFICATION FOR APPROVAL. 1/8W, 0402, Low Resistance Chip Resistor (Lead / Halogen Free)

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

SPECIFICATION FOR APPROVAL. 1/2W, 0603, Low Resistance Chip Resistor (Lead / Halogen free)

Bio-Potential Amplifiers

EDL Group #3 Final Report - Surface Electromyograph System

Sensor Array. Multi-Electrode Mapping Vest. Technical Manual

Scotchlok UR2 Connector

Resistor Glossary. Token Electronics Industry Co., Ltd. Version: January 12, Web:

Specification for UV LED

BIO-ELECTRIC MEASUREMENTS

COMPANY PRESENTATION

Context Development Details Anticipated Effects

Colors and design will come to life

1111C/P (.110 x.110 )

Thin Film Precision Chip Resistor (AR Series)

1.5SMC6.8AT3G. TVS Diodes. Surface Mount > 1500W > 1.5SMC6.8AT3G. Bi-directional. Cathode. Anode. Uni-directional. Description

IMPROVEMENTS IN ELECTROCARDIOGRAPHY SMOOTHENING AND AMPLIFICATION

Physiological Signal Processing Primer

Printing on Corrugated Board

OPERATING INSTRUCTION

Application Bulletin 240

ACRYLITE and EUROPLEX Films Always On Top

ecg accessories Additional Papers IMCO Ecg Papers Mounting Forms < Table Of Contents > For Use With Schiller

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Accelerating Scale Up of Large Area Electronics

Detection of Abnormalities in the Functioning of Heart Using DSP Techniques

Printed Electronics Product Types & Markets. Vince Cahill, VCE Solutions

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

EE 230 Experiment 10 ECG Measurements Spring 2010

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Controltac Plus Graphic Film with Comply Performance Series 250C

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

Global Acrylic Resin Market

(HI83) Thick Film Planar Dividers, High Voltage Resistors

Type CPF Series. Thin Film Precision Resistors. Key Features

FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2 SUMMARY OF CONTENTS 1. SCOPE OUTLINE REFERENCED DOCUMENTS EQUIPMENT...

IMPULSE 6000D/7000DP DEFIBRILLATOR/TRANSCUTANEOUS PACER ANALYZER. 25 reasons to differentiate Impulse 6000D/7000DP from all others

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AEC-Q200 Compliant with AEC-Q200 standard. Miniature and light weight. Suit for reflow and wave flow solder

TOUCHING EVERYDAY LIFE

SELECTING EXTERIOR TOPCOATS BASED ON AESTHETIC PERFORMANCE

(LRP) Metal Strip Chip High Power Low Ohmic Resistor. Token Electronics Industry Co., Ltd. Version: January 12, Web:

OVERVIEW OF PLASTIC SUBSTRATES FOR PRINTED ELECTRONICS

COLOUR SHADES - OVERVIEW

Marabu. Mara Star SR. Field of Application. Characteristics

Marabu. Tampacure TPC. Field of application. UV-curable, high gloss, good opacity, 1- or 2-component ink system, resistant to chemicals

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

Precision Thin Film Precision Resistors

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

MS2109A AC/DC Clamp Meter. User Manual. Contents

Digital Clamp Meter (TRMS) Model : 2727

Pressure Sensors, Accelerometers, and Custom Microstructures

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

The Heart Rate Exercise sensor can be connected to the all einstein Tablets, einstein LabMate, and einstein LabMate+.

Making Thermal Ink Jet Graphics 3M Scotchcal Opaque Imaging Media 8522CP 3M Scotchcal Instant Dry Translucent Imaging Media 8544CP

Printed Electronics: success stories and future commercial applications

3M Scotchgard Protector Graphic Film 8050

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

VC835 DIGTAL MULTIMETER Operation Manual

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

3/24/11. Introduction! Electrogenic cell

User Manual Digital Multimeter. model no.: MSR-U1000

Transcription:

Existing and Emerging Opportunities in Printed Electronics For Printers Don Banfield Conductive Compounds, Inc. Hudson, New Hampshire, USA www.conductivecompounds.com

Presentation Outline Summary of some new and existing technologies for printed electronics outside of traditional membrane switch manufacturing Discussion of requirements for understanding the technology of these applications in order to capitalize on them

Opportunities in Printed Electronics Outside of Membrane Switch Manufacturing Printed Disposable Medical Sensors made with Silver and Silver Chloride Inks (EEG, EKG, Defibrillator and Blood Glucose) Printed Flexible Heaters with Self Regulating Temperature Capabilities made using PTC Carbon Ink Printed Potentiometers and Rheostats using Carbon Ink Printing Radio Opaque Inks for Medical Devices Unique Display Panels

Printed Disposable Medical Sensors

Four Common Types of Disposable Medical Sensors Electrocardiograph (ECG or EKG) Electroencephalography (EEG) Defibrillation Blood Glucose

Printing a Disposable Medical Sensor is Similar to Printing a Membrane Switch ECG and EEG sensors incorporate printed silver chloride and/or silver ink layers that interface with a liquid or semisolid gel to detect electrical impulses on the skin, as well as the time intervals between the impulses around the area of the heart or brain, and transmit these impulses along the silver ink trace back to the device for decoding. Defibrillation pads use these traces to carry an electrical charge from a device to the skin. Blood glucose sensors use silver ink traces to transmit electrical impulses generated by a complex chemical reaction to detect glucose (sugar) levels in blood. Usually, there is graphic printing on the opposite side of the substrate where the functional inks are printed.

ECG/EKG Sensors Electrocardiograph (ECG or EKG) is a machine designed to read and record the small electrical impulses given off by muscles of the heart as they expand and contract. This is achieved using sensors attached to the skin surface to detect the electrical signals. Each heartbeat cycle produces 3 main electrical impulses. These electrical impulses or waves are known as P, QRS, and T. The P wave is typically a small wave, QRS is a complex pulse and T is a wave similar to the P wave. The P wave is generated as blood flows through the atria (two upper chambers of the heart), the QRS pulse shows what happens to the heart as the blood travels across the ventricles (lower heart chambers) and the T wave shows how the ventricular muscle recovers once it is seen that electrical impulse and gets ready for the next contraction.

EEG Sensors Electroencephalography (EEG) is similar to ECG in that it uses sensors to pick up electrical impulses on the skin surface, but it monitors activity in the brain. As brain neurons fire electrical impulses, these impulses travel along a chain of other neurons. The sensors of an EEG cannot pick up impulses from individual neurons, but the sensor can measures these large waves of impulses as they travel through millions of neurons.

Defibrillator Pads These are reverse driven sensors in the respect that they are used to pass an electrical charge from a device into a patient s body, through the skin in the heart area, in order to try to shock the heart into contracting and starting to pump.

Blood Glucose Sensors These sensors are used to quickly and accurately measure amount of blood sugar by placing a drop of blood onto the disposable sensor and inserting it into the device. The glucose level in the blood is detected through a complex chemical reaction with material on the sensor. Within the test strip, the blood is mixed with glucose oxidase, which reacts with the glucose in the blood sample, to create gluconic acid. Another chemical within the test strip, called ferricyanide, then reacts with the gluconic acid to create ferrocyanide. The electrode, within the test strip, then runs a current through the blood sample and the ferrocyanide influences this current in such a way that the concentration of blood glucose within the sample can be accurately measured within a fair margin of error. The silver or carbon ink trace printed on the sensor carries an electrical signal to the device which then displays the level of blood sugar on an LCD screen.

Specification for Medical Sensors AAMI Association for the Advancement of Medical Instrumentation Disposable ECG electrodes ANSI/AAMI EC12:2000/(R)2010

Requirements for Medical Sensor Printing and Assembly Electrical test requirements greater than required for membrane switches --DC Offset Voltage (DCO): After a 1-minute (min) stabilization period, a pair of electrodes connected gel-to-gel shall not exhibit an offset voltage greater than 100 millivolts. --Impedance (ACZ): The average value of 10-hertz impedance for at least 12 electrode pairs connected gel-to-gel, at a level of impressed current not exceeding 100 microamperes peakto-peak, shall not exceed 2 kilohms. None of the individual pair impedances shall exceed 3 kilohms. --Defibrillation recovery rate: Pair connected gel-to-gel, 5 seconds after each of four discharges of 200 volts. mv/s is tested by: During 30-sec interval following polarization potential measurement. --ACZ Impedance: At end of cycle post defibrillator overload In some applications, sensor testing adopts methods from specifications for other types of sensors because of a lack of specific procedures to use. Actual printing of medical sensors is similar to a membrane switch: silver ink traces followed by silver/silver chloride and then UV dielectric. Graphics are often printed on the back side of circuit substrate.

Requirements for Medical Sensor Printing and Assembly (continued) New requirements for long term testing include accelerated heat aging to simulate 24 months packaged storing without loss of electrical performance when electrode is powered. Speculation is that there may even be a push for 36 months. As these shelf life requirements are extended, the discrepancy between how well accelerated aging testing can mimic actual ambient packaged shelf life of a sensor appears to be more significant. Typical sensor development cycle involves adjusting the silver to silver chloride ratio to get the proper electrical response from the sensor and device, and then making sure that the ink polymer binder is compatible with the materials contained in the gel used with the electrode. Actual skin impedance varies from a hundred to hundreds of thousands of ohms based on skin color, tanning or lotions used. While it is possible to make a low impedance electrode, it is pointless to limit the impedance to less than that of skin. The problem is that high impedance electrodes may not work on some patients.

Printed Self Regulating PTC Heaters

How PTC (Positive Thermal Coefficient) Inks Work

Requirements for Printed PTC Heaters Automotive is driving current development, with heaters used in interior and exterior mirrors for many years, and GM has just launched PTC printed technology for seat heaters on one current car platform. Properties of inks (baseline resistance, PTC ratio) along with circuit design pattern of heater dictate heater performance. Key requirements are heater surface and seat surface maximum temperature, response time for seat surface temperature, and impact of surface temperature by a jacket placed on seat. Seat design, lamination and assembly of heater and location of placement in molded seat bun also contribute to overall performance. Actual printing of PTC heaters is a two step process involving printing of silver ink bus bars followed by printing of PTC carbon heater elements. Overprinting with insulating material may be used in place of film lamination to protect circuit. Emerging area of development is using large printed heaters as radiant heat sources for residential and commercial construction.

PTC Heater Example

Printed Potentiometers and Rheostats

Requirements for Printed Potentiometers and Rheostats Requires use of specialty carbon inks with high abrasion resistance and electrical stability over time with exposure to heat and humidity (examples are Acheson Minico inks and Conductive Compounds, Inc. VRI inks) Expectation is 1 million plus cycles of mechanical abrasion with minimal electrical noise output and Contact Resistance Variation (CRV), and smoothness of electrical output. Printed substrates are almost universally FR-4 circuit material, although some work is being done with flexible polyimide films. Print requirements are two layers silver first and carbon next, but curing temperatures are higher than traditional membrane switch printing, often as high as 200 o C.

Printed Potentiometers and Rheostats

Radio Opaque Inks for Medical Devices RO Inks are simply inks that can be detected by either x-ray or MRI scans Used as disposable tags, and can be pad printed or dispensed onto medical devices Single layer pad or screen printing, and drying similar to silver inks for membrane switches. Can be coated or dipped onto devices as well

Radio Opaque Ink Stent Dipping

Specialty Display Panels Traditional printed electroluminescent display technology has been established for many years. Most of the new and emerging printed display applications using printable OLED type inks are protected by IP or the critical OLED inks are used for captive manufacturing. One new technology allows membrane switch printers to print functional, printable, flexible interactive monochromic displays that operate on low voltage and can be incorporated into a wide variety of advanced functional printing applications.

Functional Interactive Monochromic Graphics Roll Printable Flexible Displays Printed Thin Flexible 7 Segment Displays