Installation instructions: Elements Vulcan+ Newport Hector Cladding

Similar documents
STEEL FRAMING WEATHERBOARD SYSTEM

WO OD LOCK W E AT H ERBOARDS & FASCIA Installa tion info r m at ion and t echnic al draw ings

Secret Fixed Shiplap rev OCT External Cladding. 70x19mm Secret Fixed Shiplap 1

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Eaves Lining Installation Guide

V Joint Shiplap rev OCT External Cladding V JOINT SHIPLAP 1


Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE

INSTALLATION GUIDE. Biowood Outdoor Wall Panel BWWPO20018 Shiplap 8x6 Deep. Green Resources Material Australia Pty Ltd

General Installation Guidelines

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

BBS Rusticated & Splaycut Cavity System

4256HM JAMES HARDIE MONOLITHIC CLADDING

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

Installation Guide. Shingles. Classical. Shingles. Warning. Storage. Cutting Shingles. Touch-Up. Eastern White Cedar

Installation Guide - Evolution Series Wood Siding

The WANZ Guide to Window Installation

Shapes Siding. Perfection Shingles. Chalk Line

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

DURABLE, STABLE AND LOW MAINTENANCE SIDING

KERRAFRONT INSTRUCTION FOR INSTALLATIONS AND USE. Cellular cladding FS-201 / FS-202. kerrafront.com

SHADOWCLAD SPECIFICATION & INSTALLATION GUIDE

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

NEVADA ASSEMBLY INSTRUCTIONS

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

Contents. Installation Guide. Dynex Soffit Installation Guide V03 March The Smart Choice in Soffit

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

technical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit

GREEN WORLD LUMBER GENUINE MAHOGANY DECKING INSTALLATION GUIDE

LVL8 H1.2 GENERAL FRAMING. Eco Friendly Revolutionary H1.2 Treatment Azotek by Zelam

PANELTEK ENGINEERED SIDING/PANELLING INSTRUCTIONS

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Sun Windows General Information New Construction Hinged Door Installation Instructions

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

SIDING INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS MILLENNIUM DECKING Before Installing Millennium Decking, please read these instructions in their entirety.

Technical Data Sheet Pergolas and Carports

External cladding technical instructions

Installation Instructions for Standard Lap and Self-Aligning Lap Siding

Installation Guide Classic Series Wood Siding

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m

Installation Instructions

INTERNAL LININGS INSTALLATION GUIDE

PRIMED STRAND REVERSIBLE SHAKE

multipanel Installation (panels) CONTENTS

installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty

INNOCLAD SHIPLAP FIXING INSTALLATION MANUAL WC13625 WC20025 WC24025

Bevel back. Technical & installation manual. Component details & drawings installation guide maintenance & care warranty

A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.

SPECIFICATION FOR. BRANZ Appraisal Certificate # 621 (2008)

Note. Returns are blocks / mouldings that have finished sides suitable for doors and windows as shown below. Surround return.

Installation Instructions for Old Mill Shingle and Designer Shake Lap Siding

External Cladding Solid Timber Profiles

DURABARRIER RIGID SHEATHING / AIR BARRIER

LOOKS AND FEELS LIKE TIMBER

Product Guide Specification

CERACLAD.

Internal timber. Preservation. Timber preservation, fire retardants and coatings

Installation Instructions for Panel Siding and Soffit

How To Install Windows: Nail-Fin Application

System for 2+ Level Buildings

Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.

Installation Guide Maibec Resistech Panel, Shingle Strips and Trims Solid Colours

NULINE PLUS WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 641 [2015]

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

KuraStone TM Installation Guide

Installation Instructions: Urbanline Euro Selekta Clad

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

WORK METHODS FOR THE RENOVAID WOOD RENOVATION SYSTEM

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

Gluing windows with SABA Glasstack 760

Linda Barker Collection Heritage Collection Classic Collection INSTALLATION GUIDE

Turada Hardwood Shingles and Shakes Installation instructions

TruGrain 6 and 4 Flat Board Siding System Assembly Installation Guidelines

TIMBER CLADDING & DETAIL DESIGN

DECKING INSTALLATION GUIDE

SECTION ROUGH CARPENTRY

Installation Guide (888)

MOULDINGS Q U A L I T Y P R O D U C E D W I T H P R I D E

Curium 19.4H Installation Instructions & Parts List

Panel Installation Instructions

HM OUTDOOR TABLE:HM OUTDOOR TABLE 25/7/08 11:18 AM Page 30

GARDEN SHED BRIGHTOLN

DIVISION 6 WOOD AND PLASTICS

SECTION LAP SIDING. A. Fiber cement lap siding, panels, single, trim, fascia, moulding and accessories.

STRUCTURAL PERFORMANCE OF TIMBER EXTERNAL CLADDING

Dubnium 11 Installation Instructions & Parts List

Dura-Lock Roof System

DYNEX SOFFIT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 908 [2016] Appraisal No. 908 (2016) BRANZ Appraisals

KERRAFRONT INSTRUCTION FOR INSTALLATION AND USE. Cellular cladding. profile.vox.pl

WET AREA PANELLING. Designer Walls. Fast

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Inspire Aledora Slate Application Guidelines

TORLYS LEATHER PLANK INSTALLATION INSTRUCTIONS

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

Ash Brook Golf Course Scotch Plains, New Jersey

Make every component count.

Aluminum Clad Wood Window Field Mulling and Stacking Instructions

Transcription:

Technical Data Wood Species Thermally Modified Softwood (Pinus Radiata) Images Profile Newport Hector - Light Band Sawn face - Secret fix 5.4 6.0 8.5 3.0 25.0 3.0 111.0 3.0 12.0 R 3.0 7.0 7.0 123.0 15.0 145.0 5.2 6.5 8.3 20.0 Product picture Quality Select Grade/face and edges virtually free of any defects (one edge knot and one small face defect allowed per piece in 20% of boards only), back face allows some isolated defects. Vertical Grain orientation on all boards. Moisture Content Kiln Dried, 7% MC (+/-%) Sizes Thickness (x width mm) Colours Standard colour range: Patina Teak Walnut Manuka Graphite Colours presented are indicative only. Dark colours are not recommended for heavy UV-exposed situations. 20 x 145 mm (125 mm effective cover) Length (cm) 360, 390, 420, 450, 480 cm - Set Length Packets (length subject to availability) Newport Hector vertical fix Newport Hector horizontal fix 1

Product Specifications Treatment Thermally modified to TM220 schedule. H3 Treated with Protim preservation system. Durability class H3 (AS1604) Density 430-450 kg/m 3 Hardness Medium-Low (3.5kN Janka) Weight ~12 kg/m 2 ( light weight cladding ) Wind zone Acceptable for wind zones up to and including N4 (non-cyclonic areas) and C2 (cyclonic areas). Alternative fixing details from a registered engineer may be required for cyclonic areas with C3 wind classification. Patent NZ Pat. 601245, AU Patent 2012101047 Forestry Certification FSC -certified mixed, No.: SGS-COC-004944 Handling Weatherboards and accessories must be kept clean dry, under cover and out of the weather prior to installation. Timber must be stored horizontally on bearers at least 100mm off the ground. Extra care must be taken during installation so as not to damage the factory finish of the boards. Wear dust mask, eye protection when cutting timber. Do not burn treated timber. Dispose of off-cuts in lined land fill or an approved furnace. Intended use Intended for use in residential and light commercial buildings. Finishing Fine bandsawn face. Coating Supplied with 1 coat of factory-applied Elements penetrating Protector Oil, or other proprietary wood stain coated all sides. Construction Laminated with vertical grain orientation. Glue Purbond HBS VOC, solvent and formaldehyde free new generation polyurethane adhesive. Type 1 adhesive (AS4364). Expected dimensional change in service Width expansion approx 2%, length expansion approx 0.5%, thickness expansion approx 3% (variation may occur between boards). Expected Service life Minimum 30 years or more when properly maintained. Warranty 25 years against rot, fungal decay and insect attack (subject to terms and conditions). 2

Fixing Timber framing is to be in accordance with AS1684 and local building code. Fix boards either vertically or horizontally at max 450mm centres Horizontal Fixing Studs to be spaced at max 450mm centres Apply water proof, breathable building wrap (sarking) eg: Tyvek Homewrap over studs keeping all overlaps pointing downwards and tape all joints. Boards may be direct-fixed to studs or optionally fixed onto vertical 45x20mm H3 treated timber cavity battens. Cavity battens are to be structurally fixed vertically to studs with 50x2.7mm HDG flathead nails placed at 300mm centres staggered 12mm either side of the batten centre line. 30mm min 50 x 2.7mm annular groove s/s nail or 40mm c/s head stainless steel screw If fixing to masonry, structurally fix 45x45mm H3 treated timber cavity battens vertically with masonry anchors at max 600mm centres staggered 12mm either side of the batten centre line. Horizontal fix Vertical Fixing Nogs to be spaced at max 450mm centres, studs at max 600mm centres Apply water proof, breathable building wrap (sarking) eg: Tyvek Homewrap over studs keeping all overlaps pointing downwards and tape all joints. Cavity batten Use CB-H-45x45 horizontal castellated (notched) and bevelled battens spaced at max 450mm centres Structurally fix CB-H-45x45 castellated (notched) and bevelled battens horizontally to nogs with 90x2.8mm HDG nails at 300mm centres staggered 12mm either side of the batten centre line. 30mm min Packer battens temporarily fixed to wall framing (Weatherboard fixing used to permanently fix the batten) 60 x 3.15mm annular groove flat head nail to achieve 30mm min. penetration If fixing to masonry, structurally fix CB-H-45x45 H3 treated timber cavity battens horizontally with stainless steel masonry anchors at max 600mm centres staggered 12mm either side of the batten centre line. Vertical fix 3

All systems Secret fix boards into positioning groove located on the tongue with a 50 x 2.7mm stainless steel flat head ring shank nail, or an 8gx40mm stainless steel self-countersinking self- drilling screw at max 450mm centres. Ensure fastener head is flush with surface - do not over-drive. Face-fix first board at bottom of wall (horizontal fix) or corner of wall (vertical fix) with a 65x2.7mm stainless steel flat head ring shank nail or 8gx50mm stainless steel countersink head screw positioned minimum 50mm from edge Allow a minimum of 2mm expansion gap between boards. Using a gauging stick, mark the cover increments of each row up the studs off the top of the starter board to keep everything straight and parallel. This is particularly important around windows and doors. Alternatively use a spacer block in the shadow line to assist even spacing Fixings at ends of boards must be at least 12mm from edge, and must be pre-drilled before applying fastener. Cut ends must be sealed with 2 coats of oil or an approved sealer or end grain sealing wax. Butt joins and ends must be sealed with construction sealant eg: Sikaflex 11FC A further coat of Protector oil or proprietary specified wood stain should be applied once boards are fixed in place according to manufacturer s instructions. External Corners Use Elements AW42 external corner moulding backed by aluminium corner angle flashing. Attach corner angle flashing to back of AW42 corner mould prior to installation with 8gx25mm stainless steel screw at 450mm centres. Fix flashing with AW42 corner moulding attached to stud or batten on either edge with 8g x 25mm screws at max 450mm centres along the flashing edge. Butt board ends snugly into the AW42 moulding and seal with construction sealant eg: Sikaflex 11FC Internal Corners Use aluminium W Flashing Fix flashing to stud or battens on either edge with 8g x 25mm screws at max 450mm centres along the flashing edge. Butt boards ends snugly into the flashing and seal with construction sealant eg: Sikaflex 11FC Fixing to clear flashing, 50mm max. from end of weatherboard 50 x 50mm external corner flashing AW42 corner moulding Seal to adjacent weatherboards with sikaflex 8g x 25mm s/s c/s head tek screw to fix flashing to corner moulding @ 450mm crs prior to installation 8g x 25mm s/s c/s head tek screw to fix flashing to studs @ 450mm crs External corner Internal corner 50mm min Weatherboards butted to flashing and sealed with modified silicone or construction sealant Flashing to provide 50mm min. cover behind weatherboards 8g x 25mm s/s c/s head tek screw to fix flashing to studs @ 450mm crs 70 x 70mm Internal corner W flashing with hem Fixings to clear flashing 50mm max. from end of weatherboard 4

Butt Joins Butt joins should be mitred at a 45 degree angle and joined over the stud, nog or batten only. Apply one fixing pre-drilled either side of the join at least 12mm from the edge. Joins in vertical boards should have the mitre sloping down so as to shed water away from the join and down the face of the of the cladding. All butt joints should be sealed with sikaflex or equivalent joint sealant. The easiest way to apply the joint sealant is to apply it to the end of one board and allow it to squeeze out as the two boards are pushed together. The excess sealant will mushroom off the two edges. Let it dry fully, and then scrape it flush with a sharp chisel. Soffit lining Moulding fitted tight up against soffit lining 50 x 2.7mm annular groove s/s nail or 40mm c/s head stainless steel screw All end grain is to be sealed with multiple coats of the timber oil to be used on the face. Top of wall Use exterior finishing moulding to close off wall For cavity systems, ensure roof is sealed off from wall cavity to prevent air movement between the two spaces. Base of wall Boards to extend minimum overlap 50mm from bottom of wall Allow least 75mm gap from bottom edge of board to ground level For cavity systems, use a perforated cavity base closer flashing at base board to allow drainage, air flow and keep out vermin. DPC Concrete foundation 10 6 50 50 x 2.7mm annular groove s/s nail or 40mm c/s head stainless steel screw Maintenance Wash down every 12 months with gentle detergent, warm water and soft brush. Within 6 months of installation apply a third coat of oil 150mm min. to paving 225mm min. to ground 150mm min. to paving 225mm min. to ground Make a maintenance check every 2 summers. Re-coat every 2-3 years or as required to maintain colour and integrity of coating. Re-coat period may be longer or shorter depending on climatic conditions and/ or positioning of cladding to the sun. For heavily soiled or mouldy areas use Elements Rejuvenator or similar oxygenating cleaner, Elements Preventor or similar mouldicide and recoat with penetrating oil. As this is a natural product, come variation in colour, movement and minor surface cracking may occur as a part of the weathering process. The product will eventually weather to grey unless a pigmented coating is reapplied periodically. If a weathered look is preferred, use grey coloured oil, allow to weather and maintain as appropriate. 5

Accessories AW42 External Corner Mould External corner angle flashing 75mm Internal W Flashing Cavity closure Elements Protector Oil 4L, 10L CB-H-45 x 45 Horizontal Cavity Batten CB-V-45 x 45 Vertical Cavity Batten Other accessories and custom profiles are available - please enquire for further information. 6