Fitting instructions for all. Sita balcony outlets, extension units and accessoires

Similar documents
Fitting instructions for all. SitaRoof- and renovation outlets, extension elements and accessories

DynaRound Hatch Guard System Installation Instructions

INSTALLATION INSTRUCTIONS

Big Kahuna Assembly Instructions

PhotoVu Digital Picture Frame Service & Repair Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SISTEMA ELEVATÓRIO ETV 460A

SolarEdge Built-in Revenue Grade Meter Troubleshooting

Roof Safe Netting CONTENTS

Pool & Hot Tub Guide

RiverSurveyor S5/M9 & HydroSurveyor Second Generation Power & Communications Module (PCM) Jan 23, 2014

m LUCASEY SLELCD COMPANY Important! Please read all warnings and cautions before installing the mount. SLELCD DETAILED INSTRUCTIONS Page 1 of 6

Installing a Squeak-Free Nascor Floor System

Banner pocket v3 Page 1/7. Banner pocket v3

TC 60 THERMOCOMPUTER TC 60. prog. start stop. Operating Instructions

This app uses callas pdftoolbox server as the imposition engine and consequently you have to have that program installed on your Switch server.

Owner's Manual & Assembly Instructions. Model No.

Owner's Manual & Assembly Instructions

Operating Instructions

MWL-MT10DX Turbo Ace Semi-Automated Tungsten Electrode Grinder

To receive a service letter, please scan the Volunteer Log and it to:

Meet the Science Expert

How to Install a Slate Tile Floor By See Jane Drill TM Copyright 2014, All Rights Reserved

Application for Drive Technology

Danger of electric shock

Acceptance and verification PCI tests according to MIL-STD

ASSEMBLE ALUMINUM TOOLBOX

Foam Rocket. Rocket Activity. Objective Students will learn about rocket stability and trajectory with rubber band-powered foam rockets.

Appendix M Trellis Type Shade Structure Design Guide

Thermoelectric Thermometer sheathed, with a lock nut on a spring, Typ TTP-313, TTP-314, TTP-315

VIP-200. Point to Point Extension Configuration Quick Start Guide. Video over IP Extender and Matrix System

Operating Instructions

RIG SOLAR FILM. High quality clear 48 gauge Polymer material \V;th excellent transmission qualities.

The MUELLER method of making a main to service connection using the MUELLER B-101 Drilling and Tapping Machine.

LAUREL SPRINGS APPLICATION FOR PROPERTY MODIFICATION

marksolid How to use marksolid for metal marking Spray 114 and Paste 015 V1.0

Coaxial Needles for electrospinning

Zintra Acoustic Textures Cutting and Installation Instructions for ½ panels

Samples from

Note: If using fusible web adhesive to secure stars, prewash all fabric but do NOT use fabric softener.

I SEWING I MACH_N! E CABINET I CA "

GENERAL TECHNICAL DATA Specifications, Directives and Standards

Airfield Lighting Product Description SAGA. System of Azimuthal Guidance for Approach (SAGA)

21 st Century Shooting

Potting Bench BUILD TIME

Supplementary Appendix to ARTC Track & Civil Code of Practice. Trackside Monuments ETD-11-01

Last update: December 26, English Translation DRAFTS of Asian Rules by Eric Wu. Contents

BigMouth

NATF CIP Requirement R1 Guideline

CURRENT AND VOLTAGE SENSORS. General Information. Overhead Current and Voltage Monitoring Insulators (CVMI)

Ten-Tec Model RX-366 Subreceiver 565/566 Subreceiver Installation and Operation Manual-74467

Drawing Canvas Word 2007

Process Gain and Loop Gain

MUELLER CO. MAGIC BOX IN-SERVICE POLYETHYLENE INSERTION MACHINE

Pre-Installation Preparation Job Aid

OPERATING MANUAL SERIES SMTBM BRUSHLESS SINGLE AXIS MODULE

INSTRUCTION BOOKLET (PUZZLES BY NIKOLA ZIVANOVIC)

2015 Chevrolet Corvette Corvette Service Manual Body Systems Vehicle Access Repair Instructions Document ID:

COMMERCIAL BUILDING PLAN REVIEW CHECKLIST CITY OF NOVI Community Development Department (248)

I I I I. Assembly Instructions:

Build a Gopher Tortoise Burrow. Instructions

MSU Extension Publication Archive. Scroll down to view the publication.

Colourful Stitches. Quick Summer Medallion. 45 x 45 Gyleen X. Fitzgerald Quick Summer Medallion.

E-Jobsheet Tablet Application Functionality

VM1AT-R1 INDUSTRIAL MICROCONTROLLER

INFINITY ALUMINUM INSTALLATION GUIDE

BASIC SAFETY AND FABRICATION GUIDE. Safety Guidelines

SINGER FUTURA TM Holiday Banner

FG-03: Hand Burn Profile

Non-binding recommended retail-price 2,30. autumn / winter 2011

REP Design LLC. Southington, CT (860)

Models 7008, 7034, 7035, 7035R & 7041 Planar Blind-Mate Connectors, dc to 40.0 GHz

Dry Contact Sensor. Communications cable - RJ-45 jack to sensor using UTP Cat 5 wire. Power source: powered by the unit. No additional power needed.

Electrical devices may only be mounted and connected by electrically skilled persons.

SK BRW Part number:

IWorknow: I Initial and Date each section below as it is completed:

Figure 1: View, connection compartment closed

OPERATING INSTRUCTIONS AND PARTS LIST

Beechcraft Bonanza HID Landing Light Assembly Kit

Improv Piecing and Matchstick Quilting By Kelly Nagel, Sulky of America

Design and fabricate a lamp using the given electrical component.

AF4000 MOD-1 OEM Production Line Troubleshooting Guide

Tube Change for PANalytical X-Pert Pro

Frequency Response of a BJT CE Amplifier

Township of Derry. Dauphin County, Pennsylvania. Residential Deck Addition Submittal Guide and Construction Fact Sheet

How are humans responsible for the environment?

SolarEdge. StorEdge Interface Installation Guide. For the S1/S2 StorEdge Interface with LG Chem Batteries and Single Phase non-hd-wave Inverters

6 th and 7 th Grade Advisory Plans (Week 16)

Transmission Substation Field Instructions

Set up and use your Beats X earphones

WiFi Lab C. Equipment Needs:

KELOX room thermostats - KM690D Digital-Standard/ KM690U Digital-Control

CB-030S Circuit Board

Security Exercise 12

Technical Documentation

CONTENTS. Product Type Output No of Output Input Approvals Page! and Series Power Outputs Voltage Voltage Number. Open Frame.

Dry Contact Sensor DCS15 User Manual

GENERAL RULES FOR ALL MALIFAUX TOURNAMENTS MALIFAUX TEAM TOURNAMENT (50 STONES)

OPERATING FEATURES & FUNCTIONS

Transcription:

Fitting instructins fr all Sita balcny utlets, extensin units and accessires

Fitting instructin Cntents General infrmatin...3 1. Sita balcny utlet with cnnectin sleeve... 4 2. Sita balcny utlet with screw-n-flange... 6 3. Sita balcny utlet with balcny utlet grating... 8 General instructins When installing flat rf drainage elements, the fllwing regulatins, amngst thers, must be bserved: DIN EN 12056-3, DIN 1986-100, DIN 1986-3, DIN 18531, DIN 18195, DIN 18234, flat rf guidelines Sme imprtant pints f these systems f rules are listed belw: Rf utlets are t be fitted at the lwest pint f a rf. In the case f steel trapeze prfile substructures, penetratins are t be reinfrced by a strengthening sheet. The basic bdy is t be jined with the substructure. A skewing f the extensin unit thrugh relative mvements f the rf cnstructin must be prevented (e.g. thrugh mechanical fixing f the unit). The flanges f the rf utlets and extensin units are t be installed Rf utlets must be freely accessible fr maintenance purpses. Rf utlets and the cnnected pipelines have t be prtected against "sweating", where apprpriate, with e.g. aluminium-cated rck wl. In the case f waterprfing seals f nly ne layer and/r lsely laid, then screw-n-flange jints must be installed with permanently cmpatible material f the same type as the waterprfing (r a suitable elastmer) fitted n bth sides. The blts f screw-n-flange jints must be checked and tightened at least three times during the curse f the fitting wrk, using a trque wrench. Rf utlets have t be serviced at least twice per year. 3

Fitting instructin 1. Sita balcny utlet with cnnectin sleeve 1.1 Munt the rf utlet t the prpsed rf sectin f the rf area. 1.2 The balcny utlet needs t be fixed mechanically in the substructure. Fr prtectin against cndensatin are the rf and balcny utlets and the cnnected pipe, if necessary, t be prtected. 1.3 Glue r weld the vapur barrier with the flange cnnectin r the cnnectin sleeve f the balcny utlet tgether. 1.4 Insert the angled sealing ring fr back flw resistance in the rf utlet bdy. 4

Fitting instructin 1.5 Apply the thermal insulatin and cut ut the shape f the extensin unit. 1.6 Trim the extensin unit if necessary, s that the flw-crss sectin with angled rf and balcny utlets will be preserved. Reap the angled sealing ring inside and the extensin element in the lwer area with the enclsed lubricant. Slide the extensin unit thrugh the angled sealing ring and fasten it mechanically t the substructure. 1.7 Glue r weld the rf waterprfing with the flange cnnectin r the cnnectin sleeve f the extensin unit tgether. 1.8 Put the dme grate frm abve int the extensin unit and engage it in the fixing ring. 5

Fitting instructin 2. Sita balcny utlet with screw-n-flange 2.1 Put the SitaCmpact screw-n-flange balcny utlet r the extensin unit in the existing rf cnstructin and screw it thrugh the plyurethane flange, utside f the flange, t the grund. 2.2 Screw the enclsed threaded pins int the, in the drain bdy fam embedded, threaded insert ring. 2.3 Lay the large cnnectin sleeve n the threaded studs n the drain bdy. In case f a bituminus sealing the bituminus membranes are welded directly t the drain bdy. 2.4 Set the psitin f the rf sheet abve the drain bdy. Use the small sealing sleeve as a template fr the hle pattern and the inlet funnel. Punch The hle pattern with a punch (ø6 mm) and cut ut the hle fr the inlet pt and place it ver the threaded pins n the sealing sleeve. By flanging several rfing membranes these always have t be lead up t the inlet pt. A seam verlap f the rf cvering in the flange area is nt allwed. 6

Fitting instructin 2.5 Lay the small sealing sleeve ver the threaded studs nt the seal. With a bituminus seal a sealing sleeve is nt prvided. The rf track have t be preheated befre flanging. 2.6 Lay the flange ver the threaded pins nt the sealing sleeve. Put the spring washers and hex nuts n the threaded pins and tighten diagnally with a maximum trque f 8 Nm. Accrding t DIN a lse- /thrust-flange cnstructin must be cntrlled and retrqued at least three times in a time curse f > 24 hurs. 2.7 The dme grate can nw be inserted int the flange. 7

Fitting instructin 3. Sita balcny utlet with balcny utlet grating 3.1 Plug the inlet filter grill f the SitaCmpact balcny utlet grating int the SitaCmpact balcny utlet r the SitaCmpact extensin unit. 3.2 Determine The height f the terrace flring. At heights lwer than 105 mm the balcny utlet grating needs t be shrtened. 3.3 At heights abve 105 mm the SitaHeight adjustment unit can be putted between the inlet filter grill and the balcny utlet grating. 3.4 Plug the balcny utlet grating int the intake f the inlet filter grill. 3.5 The terrace decking can be applied t the rf surface. 8

Fitting instructin Ntes: 9

Sita Bauelemente GmbH Ferdinand-Braun-Straße 1 D-33378 Rheda-Wiedenbrück Phne +49 (0) 2522-8340-0 Fax +49 (0) 2522-8340-100 E-Mail: inf@sita-bauelemente.de www.sita-bauelemente.cm Valid: 06.2011 Subject t technical changes, even withut ntice.